Standard deviation of scatterometer measurements from space.

The standard deviation of scatterometer measurements has been derived under assumptions applicable to spaceborne scatterometers. Numerical results are presented which show that, with sufficiently long integration times, input signal-to-noise ratios below unity do not cause excessive degradation of measurement accuracy. The effects on measurement accuracy due to varying integration times and changing the ratio of signal bandwidth to IF filter-noise bandwidth are also plotted. The results of the analysis may resolve a controversy by showing that in fact statistically useful scatterometer measurements can be made from space using a 20-W transmitter, such as will be used on the S-193 experiment for Skylab-A.

Fischer, R. E.↗

Video Guidance Sensor System with Laser Rangefinder

A video guidance sensor system for use in automated docking of a chase vehicle with a target vehicle wherein the chase. vehicle includes a laser rangefinder that uses pulse or phase time of flight measurement to measure distance. The laser rangefinder includes a diode laser pulse or phase driver that produces an output signal to a timing element and simultaneously operates a laser diode. The laser diode produces an intense light beam of a predetermined wavelength which is directed to retroreflectors that are positioned on a passive target. The laser rangefinder includes an avalanche photodetector that produces a corresponding output signal when detecting light reflected from the retroreflectors. The timing element measures a time interval between the output of the laser diode and the detection of light and supplies a corresponding output signal to a computer in order to determine the range of the target vehicle relative to the chase vehicle.

Richard T Howard↗

A fast time domain digital simulation technique for power converters - Application to a buck converter with feedforward compensation

Small signal analysis was performed earlier to demonstrate the marked improvement of dynamic properties and stability margins of a switching regulator employing a novel feedforward input filter compensation scheme. A large signal nonlinear recurrent time domain model is presented for the converter to analyse the transient response due to a step input change with and without the presence of the proposed feedforward loop. The results are verified with experimental data.

Kelkar, S. S.↗

Helical core reconstruction of a DIII-D hybrid scenario tokamak discharge

Our paper presents the first fully 3-dimensional (3D) equilibrium reconstruction of a helical core in a tokamak device. Using a new parallel implementation of the Variational Moments Equilibrium Code (PARVMEC) coupled to V3FIT, 3D reconstructions can be performed at resolutions necessary to produce helical states in nominally axisymmetric tokamak equilibria. In a flux pumping experiment performed on DIII-D, an external n=1 field was applied while a 3/2 neoclassical tearing mode was suppressed using ECCD. The externally applied field was rotated past a set of fixed diagnostics at a 20 Hz frequency. Furthermore, the modulation, were found to be strongest in the core SXR and MSE channels, indicates a localized rotating 3D structure locked in phase with the applied field. Signals from multiple time slices are converted to a virtual rotation of modeled diagnostics adding 3D signal information. In starting from an axisymmetric equilibrium reconstruction solution, the reconstructed broader current profile flattens the q-profile, resulting in an m=1, n=1 perturbation of the magnetic axis that is $\sim 50\times $ larger than the applied n=1 deformation of the edge. Error propagation confirms that the displacement of the axis is much larger than the uncertainty in the axis position validating the helical equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time-gating scintillation detector for the measurement of laser-induced fast neutrons

A time-gating scintillation detector, in which a fast high voltage switch is used for gating a channel photomultiplier, was developed for a measurement of laser-induced fast neutrons. The x rays generated from the intense femtosecond laser and the solid target interactions were suppressed selectively and a time-of-flight signal of a laser-generated fast neutron was measured effectively. The detector was used successfully to measure the neutron yield of a femtosecond, deuterated, polystyrene plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiscale wavelet decomposition of time-resolved X-ray diffraction signals in cyclohexadiene

We demonstrate how the wavelet transform, which is a powerful tool for compression, filtering, and scaling analysis of signals, may be used to separate large- and short-scale electron density features in X-ray diffraction patterns. Wavelets can isolate the electron density associated with delocalized bonds from the much stronger background of highly localized core electrons. The wavelet-processed signals clearly reveal the bond formation and breaking in the early steps of the photoinduced pericyclic ring opening reaction of 1,3-cyclohexadiene, which are not resolved in the bare signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VARIABILITY OF GAMMA-RAY EMISSION FROM BLAZARS ON BLACK HOLE TIMESCALES

We investigate the variability properties of blazars in the GeV band using data from the Fermi/Large Area Telescope (LAT) telescope. We find that blazars exhibit variability down to the minimum timescale resolvable by Fermi; this variability is a function of the peak photon count rate in the LAT. This implies that the real minimum variability timescales for the majority of blazars are typically shorter than those resolvable by the LAT. We find that for several blazars these minimum variability timescales reach those associated with the blazar central engine, the supermassive black hole. At the same time, none of the blazars exhibits variability on a timescale shorter than the black hole horizon light-crossing time and/or the period of rotation around the last stable circular orbit. Based on this fact, we argue that the timing properties of the {gamma}-ray signal could be determined by the processes in the direct vicinity of the supermassive black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TomoTherapy MLC verification using exit detector data

Purpose: Treatment delivery verification (DV) is important in the field of intensity modulated radiation therapy (IMRT). While IMRT and image guided radiation therapy (IGRT), allow us to create more conformal plans and enables the use of tighter margins, an erroneously executed plan can have detrimental effects on the treatment outcome. The purpose of this study is to develop a DV technique to verify TomoTherapy's multileaf collimator (MLC) using the onboard mega-voltage CT detectors. Methods: The proposed DV method uses temporal changes in the MVCT detector signal to predict actual leaf open times delivered on the treatment machine. Penumbra and scattered radiation effects may produce confounding results when determining leaf open times from the raw detector data. To reduce the impact of the effects, an iterative, Richardson-Lucy (R-L) deconvolution algorithm is applied. Optical sensors installed on each MLC leaf are used to verify the accuracy of the DV technique. The robustness of the DV technique is examined by introducing different attenuation materials in the beam. Additionally, the DV technique has been used to investigate several clinical plans which failed to pass delivery quality assurance (DQA) and was successful in identifying MLC timing discrepancies as the root cause. Results: The leaf open time extracted from the exit detector showed good agreement with the optical sensors under a variety of conditions. Detector-measured leaf open times agreed with optical sensor data to within 0.2 ms, and 99% of the results agreed within 8.5 ms. These results changed little when attenuation was added in the beam. For the clinical plans failing DQA, the dose calculated from reconstructed leaf open times played an instrumental role in discovering the root-cause of the problem. Throughout the retrospective study, it is found that the reconstructed dose always agrees with measured doses to within 1%. Conclusions: The exit detectors in the TomoTherapy treatment systems can provide valuable information about MLC behavior during delivery. A technique to estimate the TomoTherapy binary MLC leaf open time from exit detector signals is described. This technique is shown to be both robust and accurate for delivery verification.

60 APPLIED LIFE SCIENCES↗

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗

Emergent discrete space-time crystal of Majorana-like quasiparticles in chiral liquid crystals

Time crystals spontaneously break the time translation symmetry, as recently has been frequently reported in quantum systems. Here we describe the observation of classical analogues of both 1+1-dimensional and 2+1-dimensional discrete space-time crystals in a liquid crystal system driven by a Floquet electrical signal. These classical time crystals comprise particle-like structural features and exists over a wide range of temperatures and electrical driving conditions. The phenomenon-enabling period-doubling effect comes from their topological Majorana-like quasiparticle features, where periodic inter-transformations of co-existing topological solitons and disclinations emerge in response to external stimuli and play pivotal roles. Our discrete space-time crystals exhibit robustness against temporal perturbations and spatial defects, behaving like a time-crystalline analogues of a smectic phase. Our findings show that the simultaneous symmetry breaking in time and space can be a widespread occurrence in numerous open systems, not only in quantum but also in a classical soft matter context.

FOS: Physical sciences↗

Field-sequential stereo television

System includes viewing devices that provide low interference to normal vision. It provides stereo display observable from broader area. Left and right video cameras are focused on object. Output signals from cameras are time provided by each camera. Multiplexed signal, fed to standard television monitor, displays left and right images of object.

Perry, W. E.↗

Market study: Tactile paging system

A market survey was conducted regarding the commercialization potential and key market factors relevant to a tactile paging system for deaf-blind people. The purpose of the tactile paging system is to communicate to the deaf-blind people in an institutional environment. The system consists of a main console and individual satellite wrist units. The console emits three signals by telemetry to the wrist com (receiving unit) which will measure approximately 2 x 4 x 3/4 inches and will be fastened to the wrist by a strap. The three vibration signals are fire alarm, time period indication, and a third signal which will alert the wearer of the wrist com to the fact that the pin on the top of the wrist is emitting a morse coded message. The Morse code message can be felt and recognized with the finger.

Source record↗

A digital goniometer for VOR

A new VOR (VHF omni-range) goniometer design which promises to improve the reliability and maintainability of the VOR ground station is described. The heart of the new concept is the use of two digital phase shifters to produce the rotating figure-of-eight pattern of conventional VOR. Using digital circuits, the goniometer adjustments and calibration reduce to timing adjustments of binary signals. A common clock used for timing the digital phase shifters also synchronizes the 30 Hz modulation of the 9.96 kHz reference.

Meer, S. A.↗

Dynamics and control of coherent structures in the turbulent wall layer: An overview

We expand the velocity field in the vicinity of the wall in empirical eigenfunctions obtained from experiment. Truncating our system and using Galerkin projection, we obtain a closed set of non-linear ordinary differential equations with ten degrees of freedom. We find a rich dynamical behavior, including in particular a heteroclinic attracting orbit giving rise to intermittency. The intermittent jump from one attracting point to the other resembles in many respects the bursts observed in experiments. Specifically, the time between jumps and the duration of the jumps, is approximately that observed in a burst; the jump begins with the formation of a narrowed and intensified updraft, like the ejection phase of a burst, and is followed by a gentle, diffuse downdraft like the sweep phase of a burst. The magnitude of the Reynolds stress spike produced during a burst is limited by our truncation. The behavior is quite robust, much of it being due to the symmetries present (Aubry's group has examined dimensions up to 128 with persistence of the global behavior). We have examined eigenvalues and coefficients obtained from experiment, and from exact simulation, which differ in magnitude. Similar behavior is obtained in both cases; in the latter case, the heteroclinic orbits connect limit cycles instead of fixed points, corresponding to cross-stream waving of the streamwise rolls. The bifurcation diagram remains structurally similar, but somewhat distorted. The role of the pressure term is made clear - it triggers the intermittent jumps, which otherwise would occur at longer and longer intervals, as the system trajectory is attracted closer and closer to the heteroclinic cycle. The pressure term results in the jumps occurring at essentially random times, and the magnitude of the signal determines the average timing. Stretching of the wall region shows that the model is consistent with observations of polymer drag reduction. Change of the third order coefficients, corresponding to acceleration or deceleration of the mean flow, changes the heteroclinic cycles from attracting to repelling, increasing or decreasing the stability, in agreement with observations. The existence of fixed points is an artifact introduced by the projection; however, a decoupled model still displays the rich dynamics. Numerous assumptions made in Aubry et al. (1988) can now be proved exactly. Feeding back eigenfuncitons with the proper phase can delay the bursting, (the heteroclinic jump to the other fixed point), decreasing the drag. It is also possible to speed up the bursting, increasing mixing to control separation. Our approach is optimal for short time tracking in control.

Berkooz, Gal↗