Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Effective ZDC cross section measurement during a dedicated STAR elastic scattering physics store in Run15

At RHIC the collision rate per IP is monitored by the Zero Degree Calorimeters (ZDC) during most runs. Neutral particles produced in the collisions in the forward direction are detected in the ZDC and the collision rate corresponds to the rate of mutual neutrons above a variable threshold and within a certain coincidence window. Due to potential changes in the detector setup, con guration and electronics the ZDCs are calibrated every year by the use of vernier scans. At the end of the RHIC pp run in 2015 a dedicated run for the STAR elastic scattering physics program (PP2PP) was scheduled during which a total of 3 vernier scans was performed within the same store. This note presents the data and summarizes the results, i.e. effective ZDC cross section and the associated systematic errors from those scans.

43 PARTICLE ACCELERATORS↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Effect of coherent excitation in coherent electron cooler

We consider the possibility of coherent excitation (CE) of cooled particles in the coherent electron coolers (CeC). We consider the current CeC scheme for the Electron Ion Collider (EIC) and derive the tolerances to a systematic error in longitudinal alignment of the electron and the proton bunches in the EIC cooler set by the CE effect.

43 PARTICLE ACCELERATORS↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Dark Energy Survey Six-Year Calibration Star Catalog

This Technical Note presents a catalog of calibrated reference stars that was generated by the Forward Calibration Method (FGCM) pipeline (arXiv:1706.01542) as part of the FGCM photometric calibration of the full Dark Energy Survey (DES) 6-Year data set (Y6). This catalog provides DES grizY magnitudes for 17 million stars with i-band magnitudes mostly in the range 16 < i < 21 spread over the full DES footprint covering 5000 square degrees over the Southern Galactic Cap at galactic latitudes b < -20 degrees (plus a few outlying fields disconnected from the main survey footprint). These stars are calibrated to a uniformity of better than 1.8 milli-mag (0.18%) RMS over the survey area. The absolute calibration of the catalog is computed with reference to the STISNIC.007 spectrum of the Hubble Space Telescope CalSpec standard star C26202; including systematic errors, the absolute flux system is known at the approximately 1% level. As such, these stars provide a useful reference catalog for calibrating grizY-band or grizY-like band photometry in the Southern Hemisphere, particularly for observations within the DES footprint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Radial Component of the Magnetic Field in the Muon g-2 Experiment

A leading systematic error in the muon electric dipole moment (EDM) analysis at Muon g-2 is the presence of radial magnetic fields because they cause indistinguishable effects to the muon spin precession plane from a true EDM measurement. Measuring a non-zero EDM would place a constraint in CP-violation, indicating new physics beyond the Standard Model. The radial field is composed of an applied radial field by the surface correction coils (SCC) and a background radial field due to imperfections in the materials and alignment of magnetic elements. We determine an optimal SCC setting that best minimizes the background radial field by performing a scan at different electro-static quadrupole settings and studying its relation with the vertical beam position and applied radial field. In this talk I will present our results and describe our efforts to design an apparatus outfitted with Hall probes and tilt sensors to directly measure the radial magnetic field as a function of az imuth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncovering New Physics in the Cosmic Microwave Background: Developing Novel Theoretical Models and Machine-Learning-Powered Constraints

The search for evidence of new physics via its signatures in the cosmos is a cornerstone goal of the Office of High Energy Physics in the DOE Office of Science. Indeed, the current concordance cosmological model provides intriguing hints for beyond-the-standard-model (BSM) physics, such as dark matter and dark energy. Recently, a potential breakdown has appeared in this model, which could be initial evidence toward a further important revision in our fundamental theoretical understanding of cosmology. This breakdown is reflected in disagreements between inferences of the current expansion rate of the universe, H 0 (the Hubble constant), based on indirect, cosmological data (e.g., from the early universe) and based on direct, local measurements. Despite significant effort, a compelling new concordance cosmological model has yet to be found; achieving significant progress on this front was the first major focus of the project. Theoretical considerations indicate that if the observational discrepancies are not due to systematic errors, they strongly suggest new physics operating in the redshift range just prior to recombination, when cosmic microwave background (CMB) photons last scattered. Crucially, almost all such models produce unique signatures in the CMB temperature and polarization power spectra, which will be measured with unprecedented precision by ongoing and upcoming experiments, including the DOE-supported CMB-S4 project. However, these subtle hints of new physics must be uncovered from beneath a swath of Galactic and extragalactic foreground contamination. Current CMB analysis methods, although powerful, do not optimally infer the CMB power spectrum in the presence of non-Gaussian foregrounds. There is thus scope for theoretical improvement in this foundational challenge of cosmological inference, which formed the second major focus of the project. The primary objectives of the project were two-fold: (1) to develop new theoretical models in cosmology that can restore concordance amongst the full suite of cosmological data sets, thereby potentially providing evidence of novel BSM physics; (2) to develop new theoretical machinery to enable significant sensitivity improvements in searches for new physics in cosmology, particularly via the CMB power spectrum. The two objectives are intertwined, as the analysis methodology improvements in (2) will enable the tightest possible constraints on the signatures of new physics predicted by the novel scenarios in (1). The theoretical approaches to restore concordance focused on models involving novel scalar field dynamics in the pre-recombination universe (the “early dark energy” scenario and modifications thereof), as well as couplings between this field and other components in the standard cosmological model, such as dark matter. We also studied a model featuring a generalization of the decaying dark matter scenario, in which a sub-component of dark matter converts into dark radiation at late times in cosmic history. While these ideas are mostly driven by phenomenological considerations, this tactic has proven extremely successful in cosmology throughout the past few decades, including in the early history of evidence for dark matter and dark energy. The new theoretical machinery envisioned in (2) is undergirded by developments in signal processing and machine learning, which will enable improvements in CMB power spectrum estimation in the presence of non-Gaussian foreground contaminants. In turn, this will yield optimal sensitivity in searches for new physics in the CMB, by maximizing the cosmological information that is extracted from this observable. The most ambitious outcome of this work would be the construction of a new cosmological model that restores concordance amongst data sets. Although the individual models studied here did not fully achieve that goal, significant progress in narrowing down the model space was made, as described below. Moreover, the outcome of the methodological improvements in (2) will significantly impact a wide range of theoretical cosmology, by enabling the tightest possible constraints on any model that leaves novel signatures in the CMB temperature and polarization power spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Time Slicing of Neutrino Fluxes in Oscillation Experiments at Fermilab

Long and short baseline neutrino oscillation experiments, such as DUNE, SBND, demand high precision in reducing systematic errors, particularly those related to neutrino-nucleus interaction cross-sections. The stroboscopic approach offers a method to capture distinct neutrino energy spectra, aiding in the separation of flux and cross-section uncertainties. This report outlines the creation of short proton bunch lengths and the transport of a narrow beam down the Booster Neutrino Beamline, essential steps for the successful implementation of the stroboscopic approach.

43 PARTICLE ACCELERATORS↗

2x2 Demonstrator High-Coverage Light Readout System in a Novel LArTPC

DUNE is a long-baseline Liquid Argon Time Projection Chamber (LArTPC) neutrino oscillation experiment. Its near detectors, located at Fermi National Laboratory, will constrain systematic errors on far detector measurements. The 2x2 Demonstrator, a novel proof of concept prototype for the ND LArTPC, has a modular TPC design that mitigates event pileup in a high-occupancy nearline beam environment, further aided by a native 3D pixelated charge readout and a 30% coverage, low profile light readout. This will be the first large-scale LArTPC to utilize pixels in place of wire planes

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FRAM Version 7.1’s Bias

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. For FRAM versions 4 and earlier, the reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. For FRAM versions 5 and 6, we examined the FRAM analytical results of both the archival plutonium data and the data specifically acquired for the isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We worked out the equations representing the biases of the measured isotopes from each measurement using internal spectral parameters, such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium). The resulting biases were included in the reported uncertainties of FRAM v.5 and v.6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Proton Assembly Building at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced photo multiplier. With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D.↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

Measurement of Local Impedance Characteristics of In-Plane PEM Electrolyzer Component Features via Segmented Cell

Segmented cells are a class of advanced diagnostic devices that enable the measurement of current distribution within the active area of an electrochemical cell, allowing for the evaluation of localized impacts from operating conditions, flow fields and component inhomogeneities. Segmented cell devices have been applied to support R&D efforts for the advancement of polymer electrolyte membrane fuel cell technologies and more recently proton exchange membrane water electrolysis (PEMWE). Beyond current density distributions, segmented cells have been successfully deployed to collect the distribution of other relevant parameters such as high frequency resistance and electrode potentials. Very recently, a promising impedance method has been reported for water electrolysis where a one-dimensional segmented cell is coupled to a multichannel potentiostat, to enable the measurement of local cell impedances, further expanding the diagnostic capabilities of the segmented cell. In this study, we will present recent efforts to accurately measure local impedance characteristics for a PEMWE cell using a two-dimensional segmented cell device coupled with a multichannel potentiostat. The distribution of local resistances, i.e. high frequency, charge transfer, mass transport and catalyst layer, and iR-free overpotentials were successfully measured after eliminating sources of random and systematic error. We will discuss the application of this diagnostic on a cell containing a 1 cm feature simulating an ionomer skin. The results from these tests give insights if such an irregularity needs to be classified as a defect, and highlight the usefulness of coupling impedance spectroscopy with segmented cells for holistic spatial diagnostics of electrochemical devices.

08 HYDROGEN↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]↗

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmological Constraints from Combining Photometric Galaxy Surveys and Gravitational Wave Observatories

Spatial variations in survey properties due to selection effects generate substantial systematic errors in large-scale structure measurements in optical galaxy surveys on very large scales. On such scales, the statistical sensitivity of optical surveys is also limited by their finite sky coverage. By contrast, gravitational wave (GW) sources appear to be relatively free of these issues, provided the angular sensitivity of GW experiments can be accurately characterized. We quantify the expected cosmological information gain from combining the forecast LSST 3$\times$2pt analysis (combination of three 2-point correlations of galaxy density and weak lensing shear fields) with the large-scale auto-correlation of GW sources from proposed next-generation GW experiments. We find that in $\Lambda$CDM and $w$CDM models, there is no significant improvement in cosmological constraints from combining GW with LSST 3$\times$2pt over LSST alone, due to the large shot noise for the former; however, this combination does enable a $\sim6\%$ constraint on the linear galaxy bias of GW sources. More interestingly, the optical-GW data combination provides tight constraints on models with primordial non-Gaussianity (PNG), due to the predicted scale-dependent bias in PNG models on large scales. Assuming that the largest angular scales that LSST will probe are comparable to those in Stage III surveys ($\ell_{\rm min}\sim50$), the inclusion of next-generation GW measurements could improve constraints on the PNG parameter $f_{\rm NL}$ by up to a factor of $\simeq6.6$ compared to LSST alone, yielding $\sigma(f_{\rm NL})=8.5$. These results assume the expected capability of a network of Einstein Telescope-like GW observatories, with a detection rate of $10^6$ events/year. We investigate the sensitivity of our results to different assumptions about future GW detectors as well as different LSST analysis choices.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗