Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Measurement of a cosmographic distance ratio with galaxy and cosmic microwave background lensing

We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z~1 (background galaxies) and at the surface of last scattering at z~1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r = 0.390 +0.070 –0.062 , at an effective redshift of z = 0.53. As a result, this is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r = 0.419.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Matter Search in a Proton Beam Dump with MiniBooNE

The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86 × 10 20 protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the dark matter cross section parameter, Y = ε 2 α D (m χ /m V ) 4 ≲10 –8 , for α D = 0.5 and for dark matter masses of 0.01 < m χ < 0.3 GeV in a vector portal model of dark matter. This is the best limit from a dedicated proton beam dump search in this mass and coupling range and extends below the mass range of direct dark matter searches. Here, these results demonstrate a novel and powerful approach to dark matter searches with beam dump experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High spin flip efficiency at 255GeV for polarized protons in a ring with two full Siberian Snakes

In polarized proton collision experiments, it is highly advantageous to flip the spin of each bunch of protons during the stores to reduce the systematic errors . Experiments done at energies less than 2GeV have demonstrated a spin flip efficiency over 99%. At high energy colliders with Siberian Snakes, a single magnet spin flipper does not work because of t he large spin tune spread and the generation of multiple, overlapping resonances. A more sophisticated spin flipper, constructed of 9-dipole magnets was used to flip the spin in Relativistic Heavy Ion Collider(RHIC). Special optics choice was also used to make the spin tune spread very small. A 97% spin flip efficiency was measured both at 24GeV and 255GeV. Lastly, these results show that efficient spin flipping can be achieved at high energies using a 9-magnet spin flipper.

43 PARTICLE ACCELERATORS↗

Proton Isovector Helicity Distribution on the Lattice at Physical Pion Mass

We present a state-of-the-art calculation of the isovector quark helicity Bjorken-x distribution in the proton using lattice-QCD ensembles at the physical pion mass. We compute quasi-distributions at proton momenta P z ϵ {2.2; 2.6; 3.0} GeV on the lattice, and match them systematically to the physical parton distribution using large-momentum effective theory (LaMET).We reach an unprecedented precision through high statistics in simulations, large-momentum proton matrix elements, and control of excited-state contamination. The resulting distribution with combined statistical and systematic errors is in agreement with the latest phenomenological analysis of the spin-dependent experimental data; in particular, Δ$\bar{u}$(x) > Δ$\bar{d}$(x).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contact in the Unitary Fermi Gas across the Superfluid Phase Transition

A quantity known as the contact is a fundamental thermodynamic property of quantum many-body systems with short-range interactions. Determination of the temperature dependence of the contact for the unitary Fermi gas of infinite scattering length has been a major challenge, with different calculations yielding qualitatively different results. Here we use finite-temperature auxiliary-field quantum Monte Carlo (AFMC) methods on the lattice within the canonical ensemble to calculate the temperature dependence of the contact for the homogeneous spin-balanced unitary Fermi gas. We extrapolate to the continuum limit for 40, 66, and 114 particles, eliminating systematic errors due to finite-range effects. We observe a dramatic decrease in the contact as the superfluid critical temperature is approached from below, followed by a gradual weak decrease as the temperature increases in the normal phase. Our theoretical results are in excellent agreement with the most recent precision ultracold atomic gas experiments. Here, we also present results for the energy as a function of temperature in the continuum limit.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spurious Point Source Signals in the Galactic Center Excess

We reexamine evidence that the Galactic Center Excess (GCE) originates primarily from point sources (PSs). Here, we show that in our region of interest, non-Poissonian template fitting evidence for GCE PSs is an artifact of unmodeled north-south asymmetry of the GCE. This asymmetry is strongly favored by the fit (although it is unclear if this is physical), and when it is allowed, the preference for PSs becomes insignificant. We reproduce this behavior in simulations, including detailed properties of the spurious PS population. We conclude that the non-Poissonian template fitting evidence for GCE PSs is highly susceptible to certain systematic errors and should not at present be taken to robustly disfavor a dominantly smooth GCE.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, a μ ≡ ( g μ - 2 ) / 2 , from the Fermilab Muon g - 2 Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, ω ˜ p ′ , and of the anomalous precession frequency corrected for beam dynamics effects, ω a . From the ratio ω a / ω ˜ p ′ , together with precisely determined external parameters, we determine a μ = 116 592 057 ( 25 ) × 10 - 11 (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain a μ ( FNAL ) = 116 592 055 ( 24 ) × 10 - 11 (0.20 ppm). The new experimental world average is a μ ( exp ) = 116 592 059 ( 22 ) × 10 - 11 (0.19 ppm), which represents a factor of 2 improvement in precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reanalysis of the 𝛽− $\overline{v}$ 𝑒 Angular Correlation Measurement from the aSPECT Experiment with New Constraints on Fierz Interference

On the basis of revisions of some of the systematic errors, we reanalyzed the electron-antineutrino angular correlation (𝑎 coefficient) in free neutron decay inferred from the recoil energy spectrum of the protons which are detected in 4⁢𝜋 by the aSPECT spectrometer. With 𝑎=−0.104 02⁢(82), the new value differs only marginally from the one published in 2020. Here, the experiment also has sensitivity to 𝑏, the Fierz interference term. From a correlated (𝑏,𝑎) fit to the proton recoil spectrum, we derive a limit of 𝑏 =−0.0098⁢(193) which translates into a somewhat improved 90% confidence interval region of −0.041 ≤ 𝑏 ≤ 0.022 on this hypothetical term. Tighter constraints on 𝑏 can be set from a combined analysis of the PERKEO III (𝛽 asymmetry) and aSPECT measurement which suggests a finite value of 𝑏 with 𝑏 (𝑐) =−0.0181 ± 0.0065 deviating by 2.82⁢𝜎 from the standard model.

Beta decay↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Denoising of imaginary time response functions with Hankel projections

Imaginary-time response functions of finite-temperature quantum systems are often obtained with methods that exhibit stochastic or systematic errors. Reducing these errors comes at a large computational cost—in quantum Monte Carlo simulations, the reduction of noise by a factor of two incurs a simulation cost of a factor of four. In this paper, we relate certain imaginary-time response functions to an inner product on the space of linear operators on Fock space. We then show that data with noise typically does not respect the positive definiteness of its associated Gramian. The Gramian has the structure of a Hankel matrix. As a method for denoising noisy data, we introduce an alternating projection algorithm that finds the closest positive definite Hankel matrix consistent with noisy data. We test our methodology at the example of fermion Green's functions for continuous-time quantum Monte Carlo data and show remarkable improvements of the error, reducing noise by a factor of up to 20 in practical examples. We argue that Hankel projections should be used whenever finite-temperature imaginary-time data of response functions with errors is analyzed, be it in the context of quantum Monte Carlo, quantum computing, or in approximate semianalytic methodologies. Published by the American Physical Society 2024

Yu, Yang (ORCID:0000000186178878)↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

Solutions of the two-dimensional Hubbard model: Benchmarks and results from a wide range of numerical algorithms

Numerical results for ground-state and excited-state properties (energies, double occupancies, and Matsubara-axis self-energies) of the single-orbital Hubbard model on a two-dimensional square lattice are presented, in order to provide an assessment of our ability to compute accurate results in the thermodynamic limit. Many methods are employed, including auxiliary-field quantum Monte Carlo, bare and bold-line diagrammatic Monte Carlo, method of dual fermions, density matrix embedding theory, density matrix renormalization group, dynamical cluster approximation, diffusion Monte Carlo within a fixed-node approximation, unrestricted coupled cluster theory, and multireference projected Hartree-Fock methods. Comparison of results obtained by different methods allows for the identification of uncertainties and systematic errors. The importance of extrapolation to converged thermodynamic-limit values is emphasized. Furthermore, cases where agreement between different methods is obtained establish benchmark results that may be useful in the validation of new approaches and the improvement of existing methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS↗

DESI DR2 results. II. Measurements of baryon acoustic oscillations and cosmological constraints

We present baryon acoustic oscillation (BAO) measurements from more than 14 million galaxies and quasars drawn from the Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2), based on three years of operation. For cosmology inference, these galaxy measurements are combined with DESI Lyman-𝛼 forest BAO results presented in a companion paper (M. Abdul-Karim et al., companion paper, Phys. Rev. D 112, 083514 2025.). The DR2 BAO results are consistent with DESI DR1 and the Sloan Digital Sky Survey, and their distance-redshift relationship matches those from recent compilations of supernovae (SNe) over the same redshift range. The results are well described by a flat Λ cold dark matter (Λ⁢CDM) model, but the parameters preferred by BAO are in mild, 2.3⁢𝜎 tension with those determined from the cosmic microwave background (CMB), although the DESI results are consistent with the acoustic angular scale 𝜃 * that is well measured by Planck. This tension is alleviated by dark energy with a time-evolving equation of state parametrized by 𝑤0 and 𝑤𝑎, which provides a better fit to the data, with a favored solution in the quadrant with 𝑤 0 >−1 and 𝑤 𝑎 <0. This solution is preferred over Λ ⁢CDM at 3.1⁢𝜎 for the combination of DESI BAO and CMB data. When also including SNe, the preference for a dynamical dark energy model over Λ⁢ CDM ranges from 2.8 − 4.2⁢𝜎 depending on which SNe sample is used. We present evidence from other data combinations which also favor the same behavior at high significance. From the combination of DESI and CMB we derive 95% upper limits on the sum of neutrino masses, finding ∑𝑚 𝜈 < 0.064 eV assuming Λ ⁢CDM and ∑𝑚 𝜈 < 0.16 eV in the 𝑤0⁢𝑤𝑎 model. Unless there is an unknown systematic error associated with one or more datasets, it is clear that Λ⁢ CDM is being challenged by the combination of DESI BAO with other measurements and that dynamical dark energy offers a possible solution.

Baryon acoustic oscillations↗

Better models by discarding data?

Making the most of hard-won data in protein crystallography: to keep or not to keep, that is the question. In macromolecular X-ray crystallography, typical data sets have substantial multiplicity. This can be used to calculate the consistency of repeated measurements and thereby assess data quality. Recently, the properties of a correlation coefficient, CC{sub 1/2}, that can be used for this purpose were characterized and it was shown that CC{sub 1/2} has superior properties compared with ‘merging’ R values. A derived quantity, CC*, links data and model quality. Using experimental data sets, the behaviour of CC{sub 1/2} and the more conventional indicators were compared in two situations of practical importance: merging data sets from different crystals and selectively rejecting weak observations or (merged) unique reflections from a data set. In these situations controlled ‘paired-refinement’ tests show that even though discarding the weaker data leads to improvements in the merging R values, the refined models based on these data are of lower quality. These results show the folly of such data-filtering practices aimed at improving the merging R values. Interestingly, in all of these tests CC{sub 1/2} is the one data-quality indicator for which the behaviour accurately reflects which of the alternative data-handling strategies results in the best-quality refined model. Its properties in the presence of systematic error are documented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PtychoShelves , a versatile high-level framework for high-performance analysis of ptychographic data

Over the past decade, ptychography has been proven to be a robust tool for non-destructive high-resolution quantitative electron, X-ray and optical microscopy. It allows for quantitative reconstruction of the specimen's transmissivity, as well as recovery of the illuminating wavefront. Additionally, various algorithms have been developed to account for systematic errors and improved convergence. With fast ptychographic microscopes and more advanced algorithms, both the complexity of the reconstruction task and the data volume increase significantly. PtychoShelves is a software package which combines high-level modularity for easy and fast changes to the data-processing pipeline, and high-performance computing on CPUs and GPUs.

97 MATHEMATICS AND COMPUTING↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗