Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

MCR Container Tools

MathWorks' MATLAB is widely used in academia and industry for prototyping, data analysis, data processing, etc. Many users compile their programs using the MATLAB Compiler to run on workstations/computing clusters via the free MATLAB Compiler Runtime (MCR). The MCR facilitates the execution of code calling Application Programming Interfaces (API) functions from both base MATLAB and MATLAB toolboxes. In a Linux environment, a sizable number of third-party runtime dependencies (i.e. shared libraries) are necessary. Unfortunately, to the MTLAB community's knowledge, these dependencies are not documented, leaving system administrators and/or end-users to find/install the necessary libraries either as runtime errors resulting from them missing or by inspecting the header information of Executable and Linkable Format (ELF) libraries of the MCR to determine which ones are missing from the system. To address various shortcomings, Docker Images based on Community Enterprise Operating System (CentOS) 7, a derivative of Redhat Enterprise Linux (RHEL) 7, containing recent (2015-2017) MCR releases and their dependencies were created. These images, along with a provided sample Docker Compose YAML Script, can be used to create a simulated computing cluster where MATLAB Compiler created binaries can be executed using a sample Slurm Workload Manager script.

Haas, NicholasQ↗

Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

14 SOLAR ENERGY↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting Axion Dark Matter with Superconducting Qubits

Axion dark matter haloscopes aim to detect dark matter axions converting to single photons in resonant cavities bathed in a uniform magnetic field. A qubit (two level system) operating as a single microwave photon detector is a viable readout system for such detectors and may offer advantages over the quantum limited amplifiers currently used. When weakly coupled to the detection cavity, the qubit transition frequency is shifted by an amount proportional to the cavity photon number. Through spectroscopy of the qubit, the frequency shift is measured and the cavity occupation number is extracted. At low enough temperatures, this would allow sensitivities exceeding that of the standard quantum limit.

Dixit, Akash↗

Adaptive Model Reduction for Parareal in Time Method for Transient Stability Simulations

Real time or faster than real time simulation can enable system operators to foresee the effect of crucial contingencies on the power system dynamics and take timely actions to prevent system instability. Parareal in time method uses concurrent computations on different segments of the time domain of interest to speed up the dynamic simulations. This paper describes the application of an adaptive nonlinear model reduction method in improving computational speed of the Parareal solver. The proposed method adaptively switches between a hybrid system with selective linearization and a completely linear system based on the size of a disturbance. The functions in the hybrid system are linearized based on the electrical distance between specific generators and the area where disturbances originated. The proposed method is tested on the 327-machine 2383-bus Polish system.

Osipov, Denis↗

Machine Learning-Based Prediction of Distribution Network Voltage and Sensors Allocation: Preprint

Increasing penetration of fast-varying energy resources may negatively affect power systems' operation. At the same time, sensor deployment throughout distribution networks improves system awareness and enables the development of new and advanced voltage control solutions. Such control techniques rely on accurate prediction in anticipation to voltage violation scenarios. This paper analyzes various approaches for voltage prediction in a distribution system; it is shown that combining multiple techniques into a single regressor improves its predictive power. Moreover, a two-step regressor is proposed, where initial predictions based on a global regressor are refined by local regressors; in this case, prediction errors decrease significantly. Additionally, a clustering approach is employed for performing sensor allocation, so that only the most influential buses are selected for monitoring without diminishing prediction accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Based Prediction of Distribution Network Voltage and Sensor Allocation

Increasing penetration of fast-varying energy resources may negatively affect power systems' operation. At the same time, sensor deployment throughout distribution networks improves system awareness and enables the development of new and advanced voltage control solutions. Such control techniques rely on accurate prediction in anticipation to voltage violation scenarios. This paper analyzes various approaches for voltage prediction in a distribution system; it is shown that combining multiple techniques into a single regressor improves its predictive power. Moreover, a two-step regressor is proposed, where initial predictions based on a global regressor are refined by local regressors; in this case, prediction errors decrease significantly. Additionally, a clustering approach is employed for performing sensor allocation, so that only the most influential buses are selected for monitoring without diminishing prediction accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Understanding Cognitive and Collaborative Work: Observations in an Electric Transmission Operations Control Center

This paper describes research that is part of an ongoing project to design tools to assist in the integration of renewable energy into the electric grid. These tools will support control room dispatchers in real-time system operations of the electric power transmission system which serves much of the Western United States. Field observations comprise the first phase of this research in which 15 operators have been observed over various shifts and times of day for approximately 90 hours. Findings describing some of the cognitive and environmental challenges of managing the dynamically changing electric grid are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Correlation Between Wind and Solar Power Forecast Errors in the Western Interconnection: Preprint

Wind and solar power generations differ from conventional energy generation because of the variable and uncertain nature of their power output. This variability and uncertainty can have significant impacts on grid operations. Thus, short-term forecasting of wind and solar generation is uniquely helpful for power system operations to balance supply and demand in an electricity system. This paper investigates the correlation between wind and solar power forecasting errors.

14 SOLAR ENERGY↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

The Effect of Degraded Digital Instrumentation and Control systems on Human-system Interfaces and Operator Performance

Integrated digital instrumentation and control (I&C) systems in new and advanced nuclear power plants (NPPs) will support operators in monitoring and controlling the plants. Even though digital systems typically are expected to be reliable, their potential for degradation or failure significantly could affect the operators performance and, consequently, jeopardize plant safety. This U.S. Nuclear Regulatory Commission (NRC) research investigated the effects of degraded I&C systems on human performance and on plant operations. The objective was to develop technical basis and guidance for human factors engineering (HFE) reviews addressing the operator's ability to detect and manage degraded digital I&C conditions. We reviewed pertinent standards and guidelines, empirical studies, and plant operating experience. In addition, we evaluated the potential effects of selected failure modes of the digital feedwater control system of a currently operating pressurized water reactor (PWR) on human-system interfaces (HSIs) and the operators performance. Our findings indicated that I&C degradations are prevalent in plants employing digital systems, and the overall effects on the plant's behavior can be significant, such as causing a reactor trip or equipment to operate unexpectedly. I&C degradations may affect the HSIs used by operators to monitor and control the plant. For example, deterioration of the sensors can complicate the operators interpretation of displays, and sometimes may mislead them by making it appear that a process disturbance has occurred. We used the findings as the technical basis upon which to develop HFE review guidance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving Performance of Power Systems with Large-scale Variable Generation Additions

A power system with large-scale renewable resources, like wind and solar generation, creates significant challenges to system control performance and reliability characteristics because of intermittency and uncertainties associated with variable generation. It is important to quantify these uncertainties, and then incorporate this information into decision-making processes and power system operations. This paper presents three approaches to evaluate the flexibility needed from conventional generators and other resources in the presence of variable generation as well as provide this flexibility from a non-traditional resource – wide area energy storage system. These approaches provide operators with much-needed information on the likelihood and magnitude of ramping and capacity problems, and the ability to dispatch available resources in response to such problems.

Makarov, Yuri V.↗

Renewable Generation, Integration of

The integration of renewable generation consists of all of the changes in power system operations that are required in order to allow renewable generation sources to play a significant role in the electricity system. The impacts are mostly due to variable generation (VG), like wind and solar power. Historically these technologies have been labeled as intermittent generation, but recent trendsprefer the label variable generation. Variable generators have a maximum available generation limit that changes with time (variability) and this limit is not known with perfect accuracy (uncertainty). This uncertainty and variability is in addition to that of the existing system and can therefore create additional challenges for grid operators to maintain their current levels of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ecobee Donate Your Data 1,000 homes in 2017

This dataset is a subset of the Ecobee Donate Your Data (DYD) dataset. The Ecobee DYD data comprises user-reported metadata (of home and occupant characteristics), and data collected by Ecobee thermostats (reported in 5-minute intervals). Participant data are pulled from the Ecobee servers, and then anonymized to remove any personally identifiable information. This subset selects 1,000 single family homes in four states - California, Texas, New York, and Illinois, and span the entire year of 2017. In addition to the measurements, a metadata JSON file is included to illustrate the high-level contextual information of the dataset. The dataset can be analyzed to understand how a single-family heating, ventilation, and air-conditioning (HVAC) system operates, occupant behavior, and building thermal dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable Generation, Integration of

The integration of renewable generation consists of all of the changes in power system operations that are required in order to allow renewable generation sources to play a significant role in the electricity system. The impacts are mostly due to variable generation (VG), like wind and solar power. Historically these technologies have been labeled as intermittent generation, but recent trends prefer the label variable generation. Variable generators have a maximum available generation limit that changes with time (variability) and this limit is not known with perfect accuracy (uncertainty). This uncertainty and variability is in addition to that of the existing system and can therefore create additional challenges for grid operators to maintain their current levels of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diesel Fueled SOFC for Class 7/Class 8 On-Highway Truck Auxiliary Power

The following report documents the progress of the Cummins Power Generation (CPG) Diesel Fueled SOFC for Class 7/Class 8 On-Highway Truck Auxiliary Power (SOFC APU) development and final testing under the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy (EERE) contract DE-FC36-04GO14318. This report overviews and summarizes CPG and partner development leading to successful demonstration of the SOFC APU objectives and significant progress towards SOFC commercialization. Significant SOFC APU Milestones: Demonstrated: Operation meeting SOFC APU requirements on commercial Ultra Low Sulfur Diesel (ULSD) fuel. SOFC systems operating on dry CPOX reformate. Successful start-up and shut-down of SOFC APU system without inert gas purge. Developed: Low cost balance of plant concepts and compatible systems designs. Identified low cost, high volume components for balance of plant systems. Demonstrated efficient SOFC output power conditioning. Demonstrated SOFC control strategies and tuning methods.

08 HYDROGEN↗

Integrating Waste Heat from CO 2 Removal and Coal-Fired Flue Gas to Increase Plant Efficiency

In project DE-FE0007525, Southern Company Services demonstrated heat integration methods for the capture and sequestration of carbon dioxide produced from pulverized coal combustion. A waste heat recovery technology (termed High Efficiency System) from Mitsubishi Heavy Industries America was integrated into an existing 25-MW amine-based CO 2 capture process (Kansai Mitsubishi Carbon Dioxide Recovery Process®1) at Southern Company’s Plant Barry to evaluate improvements in the energy performance of the pulverized coal plant and CO 2 capture process. The heat integration system consists of two primary pieces of equipment: (1) the CO 2 Cooler which uses product CO 2 gas from the capture process to heat boiler condensate, and (2) the Flue Gas Cooler which uses air heater outlet flue gas to further heat boiler condensate. Both pieces of equipment were included in the pilot system. The pilot CO 2 Cooler used waste heat from the 25-MW CO 2 capture plant (but not always from product CO 2 gas, as intended). The pilot Flue Gas Cooler used heat from a slipstream of flue gas taken from downstream of Plant Barry’s air heater. The pilot also included a 0.25-MW electrostatic precipitator. The 25-MW High Efficiency System operated for approximately six weeks over a four month time period in conjunction with the 25-MW CO 2 capture facility at Plant Barry. Results from the program were used to evaluate the technical and economic feasibility of full-scale implementation of this technology. The test program quantified energy efficiency improvements to a host power plant that could be realized due to the High Efficiency System. Through the execution of this project, the team verified the integrated operation of the High Efficiency System and Kansai Mitsubishi Carbon Dioxide Recovery Process®. The ancillary benefits of the High Efficiency System were also quantified, including reduced water consumption, a decrease in toxic air emissions, and better overall air quality control systems performance.

20 FOSSIL-FUELED POWER PLANTS↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗