Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

BN-350 unattended safeguards system current status and initial fuel movement data

The Unattended and Remote Monitoring (UNARM) system at the BN-350 fast breeder reactor facility in Aktau, Kazakhstan continues to provide safeguards monitoring data as the spent fuel disposition project transitions from wet fuel storage to dry storage casks. Qualitative data from the initial cask loading procedures has been released by the International Atomic Energy Agency (IAEA) and is presented here for the first time. The BN-350 fast breeder reactor in Aktau, Kazakhstan, operated as a plutonium-producing facility from 1973 W1til 1999. Kazakhstan signed the Nonproliferation Treaty (NPT) in February 1994, and shortly afterwards the IAEA began safeguarding the reactor facility and its nuclear material. Slnce the cessation of reactor operations ten years ago, the chief proliferation concern has been the spent fuel assemblies stored in the pond on-site. By 2002, all fuel assemblies in wet storage had been repackaged into proliferation-resistant canisters. From the beginning, the IAEA's safeguards campaign at the BN-350 included a constant unattended sensor presence in the form of UNARM which monitors nuclear material activities at the facility in the absence of inspector presence. The UNARM equipment at the BN-350 was designed to be modular and extensible, allowing the system to adapt as the safeguards requirements change. This has been particularly important at the BN-350 due to the prolonged wet storage phase of the project. The primary function of the BN-350 UNARM system is to provide the IAEA with an independent, radiation-centric Containment and Surveillance (C&S) layer in addition to the standard seals and video systems. The UNARM system has provided continuous Continuity of Knowledge (COK) data for the BN-350's nuclear material storage areas in order to ensure the validity of the attended measurements during the lifetime of the project. The first of these attended measurements was characterization of the spent fuel assemblies. This characterization utilized the Spent Fuel Coincidence Counter (SFCC) instrument [ref] to measure neutron multiplicity and calculate Pu mass. These calculated masses were then compared to modeling simulation of the assemblies as well as declarations from the facility in order to baseline the amount of material under IAEA safeguards [ref]. Once the baseline was established, bundles of four or six assemblies were repackaged into proliferati n-resistant canisters. This provided an additional physical barrier to material diversion and provided further protection by choosing assemblies for each canister so that the overall dose rate met self-protection requirements. Each of the canisters were then characterized using a similar technique to the SFCC, but with the Spent Fuel Attribute Monitor (SPAM) instnunent (ref). The data from these measurements were then used to calculate an attribute proportional to the total Pu mass in each canister. This attribute was then compared to the know Pu mass of each assembly in order to verify the accuracy of SPAM. In the event that COK is lost, the SPAM detector remains positioned to reverify Pu content of individual canisters without requiring the canister to be opened.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gas and liquid measurements in air-water bubbly flows

Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Fidelity Dataset Generation for Sensor Anomalies in Power Grids using Hardware-in-the-Loop Testbed

Sensor anomalies in power grids can have significant impacts on the operation of the grid due to the increased reliance of the grid operation on data-driven applications. However, there is a lack of datasets that accurately capture these anomalies as many of the anomalies go undetected using the current bad data detectors. High-fidelity labeled datasets are essential for developing robust applications that can detect and mitigate the impacts of anomalies. In this paper, we propose a hardware-in-the-loop testbed model that can emulate the grid behavior with high-fidelity. This testbed is used to inject anomalies at various levels in the grid architecture and generate labeled datasets. These high-fidelity datasets can be used for development and validation of data-driven applications for detection and mitigation of anomalies in grids and other cyber-physical systems.

Hyder, Burhan↗

Peak2Patch: High-Fidelity Functional Group Identification through Attention-Based Fusion of Infrared and Mass Spectra

Identifying molecular structure based on spectroscopic readings is a key task in a variety of chemical and biological applications. Common spectroscopy techniques, such as Infrared (IR) Spectroscopy and Mass Spectrometry (MS), provide detailed information on the structure of molecular compounds but nonetheless require expert-level knowledge to decode. Machine learning has emerged as a potential solution for automating structure prediction from chemical spectra; however, current approaches generally focus on single sensor modalities, neglecting to leverage the complementary information contained within differing spectra. In this paper, we introduce Peak2Patch, a novel approach to fusion-enhanced prediction of functional groups from IR and mass spectra. First, we perform a detailed comparison of backbone networks for encoding both sparse mass spectra and dense IR spectra and demonstrate the superior performance of transformer neural networks over current state-of-the-art convolutional neural networks. Second, we evaluate three broad categories of fusion: early (raw feature), middle (deep feature), and late (decision) fusion, demonstrating the potential of a deep feature fusion-based approach. Lastly, we present Peak2Patch, our attention-based fusion scheme, which leverages cross-attention to mix features between encoded tokens of the two modalities. We validate our approach on a publicly available multimodal spectroscopic data set of 790k simulated molecules, demonstrating a large improvement in functional group prediction over both the previous state-of-the-art and our own strong single-modal baselines.

Jacobson, Philip [Sandia National Laboratories (SN↗

Evaluation of a Wave Powered Water Pump Performance by Ocean Field Testing and WEC-Sim Modeling

This submission from AMEC (the Atlantic Marine Energy Center) includes data from an ocean field deployment of a wave powered water pump in March 2023. The wave pump is an upweller device, designed to enhance macroalgal aquaculture. The wave pump device was deployed off the coast of Isles of Shoals Appledore Island in Maine, USA. The data were collected using a custom-built DAQ module comprised of Arduino Unos. GPS time stamp accompanies the data. The data are volumetric flow rate from the wave pump, and relative motion of the device between float and spar buoys. Flow rate is measured by flow meter, and relative motion is measured by lidar. Calibration data for the lidar and flow meter sensors are included. This data set also includes synchronous Sofar Spotter buoy data from a mooring approximately 300 feet away from the wave pump mooring. Video data from the deployment are included from both on-board the device sporadically throughout the deployment, and from a webcam for a short duration of the deployment. Hydrophone data were also taken co-currently, and are available by contacting Martin Wosnik at the University of New Hampshire. The Matlab code used to process the field data is incorporated. A biological assessment is included which aided the NEPA consultation process, prior to conducting the field deployment. A WEC-Sim numerical model of the wave pump, and a re-design effort are part of this work. Code used to validate the WEC-Sim model from the field data are also included.

16 TIDAL AND WAVE POWER↗

Intelligent Electrochemical Sensors for Precise Identification of Volatile Organic Compounds Enabled by Neural Network Analysis

The volatile organic compounds (VOCs) in a wide spectrum of categories were identified as biomarkers in aquatic environments, playing an important role in marine and freshwater ecology and global atmospheric chemistry. VOCs released from biofuel have also attracted increasing attention. Although the importance has been recognized, the portable detection and analysis methods of VOC in aquatic systems have not yet been well developed and understood. Here, in this work, we innovatively proposed an intelligent electrochemical sensing approach to classify and quantify VOCs in solution. Utilizing the cyclic voltammetry (CV) method with an ionic liquid (IL)-based electrolyte, we analyzed 50 μL samples of various VOC analytes, including acetic acid (AC), acetone, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), ethanol, formaldehyde, formic acid, methanol, methyl formate (MF), toluene, and a formaldehyde-methanol mixture, along with deionized water (DI water). The generated voltammograms were subsequently analyzed using our uniquely designed and optimized 1-D convolutional neural network (1D-CNN). This deep-learning algorithm achieved a 99.09% accuracy in VOC classification validated through fivefold cross-validation and demonstrated an impressive 94.4% test accuracy for methanol detection within a 10 μL error range. For quantification, the system accurately categorized methanol volumes ranging from 0 to 50 μL in 10 μL increments, achieving a 98.18% accuracy. A notable linear correlation (R2 = 95.56%) was found between max current density at the oxidation peak and methanol volume, with the limit of detection (LOD) at 9.3 μL. Such a sensing method exhibits potential for portability, high accuracy, and generalization in the classification and quantification, ultimately reshaping the realm of VOC analysis in solution.

42 ENGINEERING↗

Building thermal model development of typical house in U.S. for virtual storage control of aggregated building loads based on limited available information

A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.

Cui, Borui↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

An array of convergent acoustic Doppler velocimeters has been developed and tested for the high resolution measurement of three-dimensional tidal flow velocities in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use diverging acoustic beams emanating from a single instrument. This is achieved using converging acoustic beams with a sample volume at the focal point of 0.03 m 3 . The array is also able to simultaneously measure three-dimensional velocity components in a profile throughout the water column, and as such is referred to herein as a converging-beam acoustic Doppler profiler (CADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational Alstom 1MW DeepGen-IV Tidal Turbine. This proof-of-concept paper outlines system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of CADP to standard ADP velocity measurements reveals a mean difference of 8 mm/s, standard deviation of 18 mm/s, and order-of-magnitude reduction in realizable length-scale. CADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the CADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved turbulence, resource and structural loading quantification and validation of numerical simulations. Alternative modes of operation have been implemented including noise-reducing bi-static sampling. Since waves are simultaneously measured it is expected that derivatives of this system will be a powerful tool in wave-current interaction studies.

47 OTHER INSTRUMENTATION↗

A Multi-Harmonic System Identification Method for Internal Circuit Element Monitoring

Many critical infrastructures depend on the reliability of electronic circuits, whose health depends on the values of internal circuit elements that degrade over time. It is therefore important to estimate the values of internal circuit elements from external measurements and monitor them for changes. The challenge to doing so is that, typically, the internal voltages and currents are not accessible for measurement. Prior work on internal circuit element monitoring uses data obtained from sensors placed inside the circuit or requires additional circuitry to be added to the given system, both of which are undesirable. We propose a new multi-harmonic frequency-domain based system identification method that is non-intrusive. It exploits the latent non-idealities already present in the system, specifically harmonics in the measured input and output signals. We show how sensitivity analysis can be used to both assess the accuracy of the method as well as to optimize the choice of harmonics to use. We use as a motivation and illustrative example the problem of determining the equivalent series resistance and capacitance in a class of dc-link capacitance circuits in Adjustable Speed Drives. We assess the performance of this method using simulations, and establish its validity by experimental results.

Deshpande, Ankit Vivek↗

SU-D-213-03: Towards An Optimized 3D Scintillation Dosimetry Tool for Quality Assurance of Dynamic Radiotherapy Techniques

Purpose: The purpose of this work is to simulate a multi-focus plenoptic camera used as the measuring device in a real-time three-dimensional scintillation dosimeter. Simulating and optimizing this realistic optical system will bridge the technological gap between concept validation and a clinically viable tool that can provide highly efficient, accurate and precise measurements for dynamic radiotherapy techniques. Methods: The experimental prototype, previously developed for proof of concept purposes, uses an off-the-shelf multi-focus plenoptic camera. With an array of interleaved microlenses of different focal lengths, this camera records spatial and angular information of light emitted by a plastic scintillator volume. The three distinct microlens focal lengths were determined experimentally for use as baseline parameters by measuring image-to-object magnification for different distances in object space. A simulated plenoptic system was implemented using the non-sequential ray tracing software Zemax: this tool allows complete simulation of multiple optical paths by modeling interactions at interfaces such as scatter, diffraction, reflection and refraction. The active sensor was modeled based on the camera manufacturer specifications by a 2048×2048, 5 µm-pixel pitch sensor. Planar light sources, simulating the plastic scintillator volume, were employed for ray tracing simulations. Results: The microlens focal lengths were determined to be 384, 327 and 290 µm. A realistic multi-focus plenoptic system, with independently defined and optimizable specifications, was fully simulated. A f/2.9 and 54 mm-focal length Double Gauss objective was modeled as the system’s main lens. A three-focal length hexagonal microlens array of 250-µm thickness was designed, acting as an image-relay system between the main lens and sensor. Conclusion: Simulation of a fully modeled multi-focus plenoptic camera enables the decoupled optimization of the main lens and microlens specifications. This work leads the way to improving the 3D dosimeter’s achievable resolution, efficiency and build for providing a quality assurance tool fully meeting clinical needs. M.R. is financially supported by a Master’s Canada Graduate Scholarship from the NSERC. This research is also supported by the NSERC Industrial Research Chair in Optical Design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of Components for the Remote, Canister-Monitoring System

This report documents the selection of components as part of the efforts initiated to develop a remote, canister-monitoring system (RCMS) for determining and monitoring environmental conditions within dry fuel storage canisters containing aluminum clad spent nuclear fuel (ASNF) at the Idaho National Laboratory (INL). These efforts are in support of Department of Energy Office of Environmental Management (DOE-EM) investigations into technical issues associated with extended dry storage (50+ years) of ASNF. The capability to establish and monitor the performance of ASNF in situ provides the opportunity to (1) evaluate the appropriate technologies for monitoring, (2) collect canister environment conditions as soon as possible, (3) verify and validate current laboratory-based study results and analytic modeling approaches, and (4) potentially identify additional dry storage options for ASNF at the INL site. The improved understanding of ASNF behavior gained by performing this work would also contribute to the safety basis for extended dry storage in current and future configurations as well as to provide information for future transportation, conditioning, and disposal of ASNF. The parameters to be monitored by the RCMS include temperature, relative humidity, hydrogen gas concentration and radiation environment (dose). Components are selected based on the expected environmental conditions within the canister and fuel storage area, and the desired performance of the RCMS. Several of these components have been purchased and received. Future activities include component testing and calibration, software development for operation of the integrated sensor module and fabrication of a representative test volume. The results of these tests and changes to desired performance characteristics will inform subsequent activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cells determine cell density using a small protein bound to a unique tissue-specific phospholipid

Cell density is the critical parameter controlling tendon morphogenesis. Knowing its neighbors allows a cell to regulate correctly its proliferation and collagen production. A missing link to understanding this process is a molecular description of the sensing mechanism. Previously, this mechanism was shown in cell culture to rely on a diffusible factor (SNZR [sensor]) with an affinity for the cell layer. This led to purifying conditioned medium over 4 columns and analyzing the final column fractions for band intensity on SDS gels versus biological activity – a 16 kD band strongly correlated between assays. N-terminal sequencing – EPLAVVDL – identified a large gene (424 AA), extremely conserved between chicken and human. In this paper we probe whether this is the correct gene. Can the predicted large protein be cleaved to a smaller protein? EPLAVVDL occurs towards the C-terminus and cleavage would create a small 94 AA protein. This protein would run at ~10 kD, so what modifications or cofactor binding accounts for its running at 16 kD on SDS gels? This protein has no prominent hydrophobic regions, so can it be secreted? To validate its role, the chicken cDNA for this gene was tagged with myc and his and transfected into a human osteosarcoma cell line (U2OS). U2OS cells expressed the gene but not passively: differentiating into structures resembling spongy bone and expressing alkaline phosphatase, an early bone marker. Intracellularly, two bands were observed by Western blotting: the full length protein and a smaller form (26 kD). Outside the cell, a small band (28 kD) was detected, although it was 40% larger than expected, as well as multiple larger bands. These larger forms could be converted to the predicted smaller protein (94 AA + tags) by changing salt concentrations and ultrafiltering – releasing a cofactor to the filtrate while leaving a protein factor in the retentate. Using specific degradative enzymes and mass spectrometry, the bone cofactor was identified as a lipid containing a ceramide phosphate, a single chained glycerol lipid and a linker. Tendon uses a different cofactor made up of two fatty acid chains linked directly to the phosphate yielding a molecule about half the size. Moreover, adding the tendon factor/cofactor to osteosarcoma cells causes them to stop growing, which is opposite to its role with tendon cells. Thus, the cofactor is cell type specific both in composition and in the triggered response. Further support of its proposed role came from frozen sections from 5 week old mice where an antibody to the factor stained strongly at the growing ends of the tendon as predicted. In conclusion, the molecule needed for cell density signaling is a small protein bound to a unique, tissue-specific phospholipid yielding a membrane associated but diffusible molecule. Signal transduction is postulated to occur by an increased ordering of the plasma membrane as the concentration of this protein/lipid increases with cell density.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Compact Ceilometer (Final Scientific-Technical Report)

Fibertek is developing a novel ceilometer system that provides a new measurement capability not currently available to weather stations such as those in the Department of Energy's AmeriFlux network. Commercially available instruments do not have the sensitivity to see atmospheric aerosols. If the atmospheric aerosols can be measured, then the altitude of the boundary layer can be determined from a discontinuity in the aerosol concentration. The altitude of the boundary layer is a critical parameter in climate and weather models, and adding this piece of information will greatly improve the accuracy of these models. Fibertek's design provides this capability in an inexpensive robust fieldable instrument by applying a new sensor technology: the Silicon Photomultiplier (SiPM). SiPMs are called "photomultipliers" in that they provide very similar performance as a traditional photomultiplier including single photon sensitivity and linear response. However, they are a completely different technology which offers several advantages. They are small, inexpensive, solid-state, and extremely robust. They do not require cooling. They operate at much lower voltages. They cannot be damaged by inadvertent reflections, and when saturated they recover in less than a microsecond, so they don't need to be shielded from the outgoing laser pulse. In short, they make single photon sensitivity accessible for an inexpensive, simple, rugged, fieldable system. In this Phase 1 effort Fibertek developed a breadboard version of the ceilometer to demonstrate the feasibility of our approach. Our partner, Penn State, conducted atmospheric measurements to validate the lidar’s performance and determine algorithms for automatically identifying the height of the boundary layer. The lidar shows sufficient sensitivity to fully characterize the boundary layer in clear air daytime and nighttime conditions.

47 OTHER INSTRUMENTATION↗

Multimodal Data Fusion via Entropy Minimization

The use of gradient-based data-driven models to solve a range of real-world remote sensing problems can in practice be limited by the uniformity of available data. Use of data from disparate sensor types, resolutions, and qualities typically requires compromises based on assumptions that are made prior to model training and may not necessarily be optimal given over-arching objectives. For example, while deep neural networks (NNs) are state-of-the-art in a variety of target detection problems, training them typically requires either limiting the training data to a subset over which uniformity can be enforced or training independent models which subsequently require additional score fusion. The method we introduce here seeks to leverage the benefits of both approaches by allowing correlated inputs from different data sources to co-influence preferred model solutions, while maintaining flexibility over missing and mismatching data. In this work we propose a new data fusion technique for gradient updated models based on entropy minimization and experimentally validate it on a hyperspectral target detection dataset. We demonstrate superior performance compared to currently available techniques using a range of realistic data scenarios, where available data has limited spacial overlap and resolution.

97 MATHEMATICS AND COMPUTING↗