Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Molecular Spectroscopy and Remote-Sensing of the Earth's Atmosphere: Progress from Laboratory Studies

In this paper we present some recent developments in the field of molecular spectroscopy applied to the measurement of trace gases in the Earth's atmosphere, in particular concerning the spectroscopy of unstable species or radicals and of isotopic species, but also in the field of quantitative spectroscopy, in the context of more and more challenging requirements arising from modern remote-sensing experiments.

58 GEOSCIENCES↗

A master equation approach to the dynamics of zero electron kinetic energy (ZEKE) states and ZEKE spectroscopy

We have theoretically studied important dynamic processes involved in zero electron kinetic energy (ZEKE) spectroscopy using the density matrix method with the inverse Born-Oppenheimer approximation basis sets. In ZEKE spectroscopy, the ZEKE Rydberg states are populated by laser excitation (either a one- or two-photon process), which is followed by autoionizations and l-mixing due to a stray field. The discrimination field is then applied to ionize loosely bound electrons in the ZEKE states. This is followed by using the extraction field to extract electrons from the ZEKE levels which have a strength comparable to that of the extraction field. These extracted electrons are measured for the relative intensities of the ion states under investigation. The spectral positions are determined by the applied laser wavelength and modified by the extraction electric field. In this paper, all of these processes are conducted within the context of the density matrix method. The density matrix method can provide not only the dynamics of system's population and coherence (or phase) but also the rate constants of the processes involved in the ZEKE spectroscopy. Numerical examples are given to demonstrate the theoretical treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control of resonance enhanced multi-photon ionization photoelectron spectroscopy by phase-shaped femtosecond laser pulse

In this paper, we theoretically demonstrate that the (2+1+1) resonance enhanced multi-photon ionization photoelectron spectroscopy in sodium atom can be effectively controlled by shaping femtosecond laser pulse with a {pi} phase step modulation in weak laser field, involving its total photoelectron energy, maximal photoelectron intensity, and spectroscopic bandwidth. Our results show that the total photoelectron energy can be suppressed but not enhanced, the maximal photoelectron intensity can be enhanced and also suppressed, and the photoelectron spectroscopy can be tremendously narrowed. These theoretical results can provide a feasible scheme to achieve the high-resolution photoelectron spectroscopy and study the excited state structure in atomic and molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton induced quasi-monochromatic x-ray beams for soft x-ray spectroscopy studies and selective x-ray fluorescence analysis

We present the analytical features and performance of an x-ray spectroscopy end station of moderate energy resolution operating with proton-induced quasi-monochromatic x-ray beams. The apparatus was designed, installed and operated at the 5.5 MV Tandem VdG Accelerator Laboratory of the Institute of Nuclear Physics, N.C.S.R. 'Demokritos,' Athens. The setup includes a two-level ultrahigh vacuum chamber that hosts in the lower level up to six primary targets in a rotatable holder; there, the irradiation of pure element materials-used as primary targets-with few-MeV high current ({approx}{mu}A) proton beams produces intense quasi-monochromatic x-ray beams of selectable energy. In the chamber's upper level, a six-position rotatable sample holder hosts the targets considered for x-ray spectroscopy studies. The proton-induced x-ray beam, after proper collimation, is guided to the sample position whereas various filters can be also inserted along the beam's path to eliminate the backscattered protons or/and to absorb selectively components of the x-ray beam. The apparatus incorporates an ultrathin window Si(Li) spectrometer (FWHM 136 eV at 5.89 keV) coupled with low-noise electronics capable of efficiently detecting photons down to carbon K{alpha}. Exemplary soft x-ray spectroscopy studies and results of selective x-ray fluorescence analysis are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct-reaction studies by particle-{gamma} coincidence spectroscopy using Csi-Hpge and Si-Hpge arrays

Particle-{gamma} and particle-{gamma}-{gamma} coincidence spectroscopy has several advantages in the study of direct reactions (particularly in inverse kinematics) since it can generally allow determination of: decay paths; high-precision level energies; multipolarities of transitions; and cross sections. Techniques for studying direct reactions by particle-{gamma} coincidence spectroscopy are presented for two cases: (1) heavy-ion reactions with CsI-HPGe, and (2) light-ion reactions with Si-HPGe. Future direct-reaction studies with radioactive ion beams (RIBs) will mostly involve low beam intensities and inverse kinematics (i.e., A{sub beam}>A{sub target}), which eliminates the traditional use of magnetic spectrometers. Particle-{gamma} coincidence spectroscopy currently provides the most viable method to study direct reactions with nuclei of any level density. In the present study, the capabilities and limitations of the technique are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new, low temperature long-pass cell for mid-infrared to terahertz spectroscopy and synchrotron radiation use

A new cell has been designed for accurate spectroscopic measurements in the 80–400 K temperature range with variable path lengths from 3 to more than 141 m. The spectral coverage at these temperatures ranges from the visible to less than 10 cm{sup −1}, thanks to the use of diamond windows. The design of the cryostat and vacuum setups allows vibration-free operation. The equipment provides temperature homogeneity and pressure control to better than 2% over the 100–400 K and the 0.1–1000 mbar ranges. Remote-controlled opto-mechanical systems enable in situ adjustments as well as changes of the optical path length within half an hour, in order to optimize measurement time in an open user facility. It allows then to meet the specific requirements of high resolution measurements on the Far-Infrared AILES beamline at SOLEIL as well at the LISA facility, in Créteil, in the mid-IR. This new instrument opens up the way for many experiments in the field of high-resolution gas-phase IR spectroscopy, in particular, in quantitative spectroscopy for atmospheric applications: measurements of absorption line parameters (absolute intensities, cross sections, and pressure-induced widths) using Fourier transform spectroscopy. The design and performance of the equipment are briefly presented and illustrated on spectroscopic examples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supercontinuum spatial modulation spectroscopy: Detection and noise limitations

Supercontinuum spatial modulation spectroscopy is a facile tool for conducting single molecule/particle extinction spectroscopy throughout the visible and near infrared (420–1100 nm). The technique's capabilities are benchmarked using individual Au nanoparticles (NPs) as a standard since they are well studied and display a prominent plasmon resonance in the visible. Extinction spectra of individual Au NPs with diameters (d) ranging from d ∼ 8 to 40 nm are resolved with extinction cross sections (σ{sub ext}) of σ{sub ext} ∼1 × 10{sup −13}–1 ×10{sup −11} cm{sup 2}. Corresponding signal-to-noise ratios range from ∼30 to ∼1400. The technique's limit of detection is determined to be 4.3 × 10{sup −14} cm{sup 2} (4.3 nm{sup 2}). To showcase supercontinuum spatial modulation spectroscopy's broader applicability, extinction spectra are acquired for other model systems, such as individual single-walled carbon nanotubes (SWCNTs) and CdSe nanowires. We show for the first time extinction spectra of individual (8,3) and (6,5) SWCNTs. For both chiralities, their E{sub 11} [(8,3) 1.30 eV (952 nm); (6,5) 1.26 eV (986 nm)] and E{sub 22} [(8,3) 1.86 eV (667 nm); (6,5) 2.19 eV (567 nm)] excitonic resonances are seen with corresponding cross sections of σ{sub ext} ∼ 10{sup −13} cm{sup 2} μm{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of asymmetric binary glass formers. I. A dielectric and nuclear magnetic resonance spectroscopy study

Dielectric spectroscopy as well as {sup 2}H and {sup 31}P nuclear magnetic resonance spectroscopy (NMR) are applied to probe the component dynamics of the binary glass former tripropyl phosphate (TPP)/polystyrene (PS/PS-d{sub 3}) in the full concentration (c{sub TPP}) range. In addition, depolarized light scattering and differential scanning calorimetry experiments are performed. Two glass transition temperatures are found: T{sub g1}(c{sub TPP}) reflects PS dynamics and shows a monotonic plasticizer effect, while the lower T{sub g2}(c{sub TPP}) exhibits a maximum and is attributed to (faster) TPP dynamics, occurring in a slowly moving or immobilized PS matrix. Dielectric spectroscopy probing solely TPP identifies two different time scales, which are attributed to two sub-ensembles. One of them, again, shows fast TPP dynamics (α{sub 2}-process), the other (α{sub 1}-process) displays time constants identical with those of the slow PS matrix. Upon heating the α{sub 1}-fraction of TPP decreases until above some temperature T{sub c} only a single α{sub 2}-population exists. Inversely, below T{sub c} a fraction of the TPP molecules is trapped by the PS matrix. At low c{sub TPP} the α{sub 2}-relaxation does not follow frequency-temperature superposition (FTS), instead it is governed by a temperature independent distribution of activation energies leading to correlation times which follow Arrhenius laws, i.e., the α{sub 2}-relaxation resembles a secondary process. Yet, {sup 31}P NMR demonstrates that it involves isotropic reorientations of TPP molecules within a slowly moving or rigid matrix of PS. At high c{sub TPP} the super-Arrhenius temperature dependence of τ{sub 2}(T), as well as FTS are recovered, known as typical of the glass transition in neat systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous probing of bulk liquid phase and catalytic gas-liquid-solid interface under working conditions using attenuated total reflection infrared spectroscopy

Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the use of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced visible and near-infrared capabilities of the JET mirror-linked divertor spectroscopy system

The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dβ, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical re-injection in cavity-enhanced absorption spectroscopy

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high pressure x-ray photoelectron spectroscopy experimental method for characterization of solid-liquid interfaces demonstrated with a Li-ion battery system

We report a methodology for a direct investigation of the solid/liquid interface using high pressure x-ray photoelectron spectroscopy (HPXPS). The technique was demonstrated with an electrochemical system represented by a Li-ion battery using a silicon electrode and a liquid electrolyte of LiClO{sub 4} in propylene carbonate (PC) cycled versus metallic lithium. For the first time the presence of a liquid electrolyte was realized using a transfer procedure where the sample was introduced into a 2 mbar N{sub 2} environment in the analysis chamber without an intermediate ultrahigh vacuum (UHV) step in the load lock. The procedure was characterized in detail concerning lateral drop gradients as well as stability of measurement conditions over time. The X-ray photoelectron spectroscopy (XPS) measurements demonstrate that the solid substrate and the liquid electrolyte can be observed simultaneously. The results show that the solid electrolyte interphase (SEI) composition for the wet electrode is stable within the probing time and generally agrees well with traditional UHV studies. Since the methodology can easily be adjusted to various high pressure photoelectron spectroscopy systems, extending the approach towards operando solid/liquid interface studies using liquid electrolytes seems now feasible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear and third- and fifth-order nonlinear spectroscopies of a charge transfer system coupled to an underdamped vibration

We study hole, electron, and exciton transports in a charge transfer system in the presence of underdamped vibrational motion. We analyze the signature of these processes in the linear and third-, and fifth-order nonlinear electronic spectra. Calculations are performed with a numerically exact hierarchical equations of motion method for an underdamped Brownian oscillator spectral density. We find that combining electron, hole, and exciton transfers can lead to non-trivial spectra with more structure than with excitonic coupling alone. Traces taken during the waiting time of a two-dimensional (2D) spectrum are dominated by vibrational motion and do not reflect the electron, hole, and exciton dynamics directly. We find that the fifth-order nonlinear response is particularly sensitive to the charge transfer process. While third-order 2D spectroscopy detects the correlation between two coherences, fifth-order 2D spectroscopy (2D population spectroscopy) is here designed to detect correlations between the excited states during two different time periods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunneling spectroscopy of Al/AlO{sub x}/Pb subjected to hydrostatic pressure

We develop an experimental tool to investigate high-pressure electronic density of state by combining electron tunneling spectroscopy measurements with high-pressure technique. It is demonstrated that tunneling spectroscopy measurement on Al/AlO{sub x}/Pb junction is systematically subjected to hydrostatic pressure up to 2.2 GPa. Under such high pressure, the normal state junction resistance is sensitive to the applied pressure, reflecting the variation of band structure of the barrier material upon pressures. In superconducting state, the pressure dependence of the energy gap Δ{sub 0}, the gap ratio 2Δ{sub 0}/k{sub B}T{sub c}, and the phonon spectral energy is extracted and compared with those obtained in the limited pressure range. Our experimental results show the accessibility and validity of high pressure tunneling spectroscopy, offering wealthy information about high pressure superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time sensing of epithelial cell-cell and cell-substrate interactions by impedance spectroscopy on porous substrates

Oxidized porous silicon (PS) is a common topographical biocompatible substrate that potentially provides a distinct in vitro environment for better understanding of in vivo behavior. But in the reported studies on oxidized PS, cell-cell and cell-substrate interactions have been detected only by fluorescent labeling. This paper is the first attempt to investigate real-time sensing of these interactions on HaCaT cells by label-free impedance spectroscopy on oxidized PS of two pore diameters (50 and 500 nm). One of the major requirements for successful impedance spectroscopy measurement is to restrict the channeling of electric field lines through the pores. To satisfy this criterion, we have designed the pore depths after analyzing the penetration of the medium by using computational fluid dynamics simulation. A distributed electrical model was also developed for estimating the various cellular attributes by considering a pseudorandom distribution of pores. It is observed from the impedance measurements and from the model that the proliferation rate increases for 50 nm pores but decreases for 500 nm pores compared to that for planar substrates. The rate of decrease in cell substrate separation (h) in the initial stage is more than the rate of increase in cell-cell junction resistance (R{sub b}) corresponding to the initial adhesion phase of cells. It is observed that R{sub b} and h are higher for 50 nm pores than those for planar substrates, corresponding to the fact that substrates more conducive toward cell adhesion encourage cell-cell interactions than direct cell-substrate interactions. Thus, the impedance spectroscopy coupled with the proposed theoretical framework for PS substrates can sense and quantify the cellular interactions.

60 APPLIED LIFE SCIENCES↗

The spectroscopy and photochemistry of quinioline structural isomers: (E)- and (Z)-phenylvinylnitrile

In Titan’s atmosphere, photochemical pathways that lead to nitrogen heteroaromatics may incorporate photoisomerization of their structural isomers as a final step. (E)- and (Z)-phenylvinylnitrile ((E)- and (Z)-PVN, C{sub 6}H{sub 5} —CH=CHCN) are structural isomers of quinoline that themselves possess extensive absorptions in the ultraviolet, and thus may engage in such photoisomerization pathways. The present study explores the vibronic spectroscopy and photo-induced isomerization of gas-phase (E)- and (Z)-PVN in the 33,600-35,850 cm{sup −1} region under jet-cooled conditions. The S{sub 0}-S{sub 1} origins for (E)- and (Z)-PVN have been identified at 33 827 cm{sup −1} and 33 707 cm{sup −1}, respectively. Isomer-specific UV-UV hole-burning and UV depletion spectra reveal sharp vibronic structure that extends over almost 2000 cm{sup −1}, with thresholds for fast non-radiative decay identified by a comparison between hole-burning and UV depletion spectra. Dispersed fluorescence spectra of the two isomers enable the assignment of many low frequency transitions in both molecules, aided by harmonic frequency calculations (B3LYP/6-311++G(d,p)) and a comparison with the established spectroscopy of phenylvinylacetylene, the ethynyl counterpart to PVN. Both isomers are proven to be planar in both the S{sub 0} ground and S{sub 1} electronic excited states. (E)-PVN exhibits extensive Duschinsky mixing involving out-of-plane modes whose frequencies and character change significantly in the ππ{sup ∗} transition, which modulates the degree of single- and double-bond character along the vinylnitrile substituent. This same mixing is much less evident in (Z)-PVN. The spectroscopic characterization of (E)- and (Z)-PVN served as the basis for photoisomerization experiments using ultraviolet hole-filling spectroscopy carried out in a reaction tube affixed to the pulsed valve. Successful interconversion between (E) and (Z)-PVN was demonstrated via ultraviolet hole-filling experiments. Photoexcitation of (E)- and (Z)-PVN at their respective S{sub 0}-S{sub 1} origins failed to produce quinoline, a simple polycyclic aromatic nitrogen heterocylcle, within the detection sensitivity of our experiments. Stationary points along the potential energy surface associated with (Z)-PVN → quinoline isomerization showed a barrier of 93 kcal/mol associated with the first step in the isomerization process, slowing the interconversion process at the excitation energies used (96 kcal/mol) to timescales beyond those probed in the present experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Communication: Coherences observed in vivo in photosynthetic bacteria using two-dimensional electronic spectroscopy

Energy transfer through large disordered antenna networks in photosynthetic organisms can occur with a quantum efficiency of nearly 100%. This energy transfer is facilitated by the electronic structure of the photosynthetic antennae as well as interactions between electronic states and the surrounding environment. Coherences in time-domain spectroscopy provide a fine probe of how a system interacts with its surroundings. In two-dimensional electronic spectroscopy, coherences can appear on both the ground and excited state surfaces revealing detailed information regarding electronic structure, system-bath coupling, energy transfer, and energetic coupling in complex chemical systems. Numerous studies have revealed coherences in isolated photosynthetic pigment-protein complexes, but these coherences have not been observed in vivo due to the small amplitude of these signals and the intense scatter from whole cells. Here, we present data acquired using ultrafast video-acquisition gradient-assisted photon echo spectroscopy to observe quantum beating signals from coherences in vivo. Experiments were conducted on isolated light harvesting complex II (LH2) from Rhodobacter sphaeroides, whole cells of R. sphaeroides, and whole cells of R. sphaeroides grown in 30% deuterated media. A vibronic coherence was observed following laser excitation at ambient temperature between the B850 and the B850{sup ∗} states of LH2 in each of the 3 samples with a lifetime of ∼40-60 fs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗