1,2-Addition and cycloaddition reactions of niobium bis(imido) and oxo imido complexes
Another slice of pi: the addition of a second π-donor ligand engenders 1,2-addition and [2 + 2] cycloaddition reactivity across Nb-imido and Nb-oxo bonds.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Another slice of pi: the addition of a second π-donor ligand engenders 1,2-addition and [2 + 2] cycloaddition reactivity across Nb-imido and Nb-oxo bonds.
The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.
© ASCE. Levee stability is highly influenced by seepage. Specifically, hydraulic conductivity distribution within a levee influences pore pressure distribution and controls the drained strength of the soil. In this study the influence of hydraulic conductivity and blanket layer thickness on failure probability is evaluated within the context of reliability analyses that also include soil strength and unit weight as random variables. First-Order Reliability Method (FORM) is used to evaluate reliability, rank random variables by importance and to obtain sensitivity of the solution to each random variable and its distribution parameters. Stability is computed using Spencer's method of slices coupled to a finite element seepage code to directly evaluate pore pressure. In addition, response surface method solutions are compared to the direct reliability solution to assess response surface accuracy. The results show that blanket layer thickness is more important than most strength parameters and that the uncertainty in hydraulic conductivity is less important to the variance in safety factor for the case of a low-permeability blanket layer. Numerical challenges caused by implementing a finite element limit-state function are discussed. Response surface methods are found to give a reasonable approximation to the direct reliability solution when the design point is between response surface fitting points.
X-ray microtomography and ImageJ 1.39 u is used as a tool to quantify volume percentage of B{sub 4}C as fillers in thermoplastic-natural rubber blend composites. The use of percentage of area occupied by fillers as obtain from ImageJ from the microtomography sliced images enables the proposed technique to easily obtain the amount volume percentage of B{sub 4}C in the composite non-destructively. Comparison with other technique such as density measurement and chemical analysis proves the proposed technique as one of the promising approach.
The photodissociation dynamics of formic acid have been studied using the velocity map ion imaging at the UV region. The measurements were made with resonance enhancement multiphoton ionization (REMPI) spectroscopy and dc slicing ion imaging. The OH REMPI spectrum from the photodissociation of formic acid at 244 nm has been recorded. The spectrum shows low rotational excitation (N{<=}4). By fixing the probe laser at the specific rotational transitions, the resulting OH images from various dissociation wavelengths have been accumulated. The translational energy distributions derived from the OH images imply that about half of the available energies go to the photofragments internal excitation. The dissociation dynamics of formic acid were also discussed in view of the recent theoretical calculations.
We present tomographic slices of fast X-ray computed microtomography, focusing on one hand on the comparison of scans with identical scan time but varying experimental settings, on the other hand on comparing scans with total scan times that are two orders of magnitude apart. We show that streaks in the Fourier-space of the transformed images appear when the number of projections is reduced. These streaks exhibit spacing by the same angle as the one that is covered by the sample during the exposure time of one projection. Further a method for the estimation of information loss in fast scans is presented.
Zinc is known to play a relevant role in growth and development; it has stimulatory effects on in vitro and in vivo bone formation and an inhibitory effect on in vitro osteoclastic bone resorption. The inorganic component of the bone tissue is nonstoichiometric apatite; changes in the composition of hidroxyapatite are subject of studies in order to improve the tissue response after implantation. The objective of this study was to investigate the effect of 0.5% zinc-containing hydroxyapatite in comparison to hydroxyapatite on osseous repair of rabbit's tibia. Cylinders (2x6 mm) of both materials were produced according to the specification of the International Organization for Standardization. Ethics Commission on Teaching and Research in Animals approved this project (HUAP-195/06). Fifteen White New Zealand rabbits were submitted to general anesthesia and two perforations (2 mm) were made in each tibia for implantation of zinc-containing hydroxyapatite cylinders (left tibia) and hydroxyapatite cylinders (right tibia). After 1, 2 and 4 weeks, the animals were killed and one fragment of each tibia with the cylinder was collected and embedded in a methacrylate-based resin and cut into slices (approx200 {mu}m thickness), parallel to the implant's long axis with a precision diamond saw for Synchrotron Radiation X-ray Microfluorescence investigation. The accomplishment of the standard procedures helped the planning, execution and the comparative analysis of the results. The chemical and physical properties of the biomaterials were modified after its implantation and the incorporation of zinc. Both materials are biocompatible and promote osteoconduction and favored bone repair.
A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.
The SOLEIL storage ring presents a very high fraction of its circumference dedicated to accommodate Insertion Devices (ID). Over the 25 presently planned insertion devices presenting a large variety of systems, 16 have been already installed and commissioned in September 2009. The UV-VUV region is covered with electromagnetic devices, offering tuneable polarisations. An electromagnet/permanent magnet undulator using copper sheets coils for fast switching of the helicity is under construction. 13 APPLE-II type undulators, with period ranging from 80 down to 36 mm, provide photons in the 0.1-10 keV region, some of them featuring tapering or quasi-periodicity. Five U20 in vacuum undulators cover typically the 3-30 keV range whereas an in vacuum wiggler, with compensation of the magnetic forces via adequate springs will cover the 10-50 keV spectral domain. R and D on cryogenic in-vacuum undulator is also under progress. A magnetic chicane using permanent magnet dipoles has also been designed in order to accommodate two canted undulators on the same straight section. A wiggler dedicated to slicing (production of femto second long pulses) is also being designed, its radiation will also serve for an X-ray beamline.
At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress.Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.
Aim: To visualize and validate iron deposition in two cases of multiple sclerosis using rapid scanning X-Ray Fluorescence (RS-XRF) and Susceptibility Weighted Imaging (SWI). Material and Methods: Two (2) coronal cadaver brain slices from patients clinically diagnosed with multiple sclerosis underwent magnetic resonance imaging (MRI), specifically SWI to image iron content. To confirm the presence of iron deposits and the absence of zinc-rich myelin in lesions, iron and zinc were mapped using RS-XRF. Results: MS lesions were visualized using FLAIR and correlated with the absence of zinc by XRF. XRF and SWI showed that in the first MS case, there were large iron deposits proximal to the draining vein of the caudate nucleus as well as iron deposits associated with blood vessels throughout the globus pallidus. Less iron was seen in association with lesions than in the basal ganglia. The presence of larger amounts of iron correlated reasonably well between RS-XRF and SWI. In the second case, the basal ganglia appeared normal and acute perivascular iron deposition was absent. Conclusion: Perivascular iron deposition is seen in some but not all MS cases, giving credence to the use of SWI to assess iron involvement in MS pathology in vivo.
The experimental PWFA facility currently under construction at the Budker INP is described. The objective is to use electron and positron beams extracted from the VEPP-5 damping ring in PWFA experiments. Due to longitudinal beam compression many PWFA schemes including the efficient blowout regime as well as multibunch regime can be studied. The simulations of beam dynamics in the facility are presented. Also we propose a simple technique for longitudinal beam slicing using dipole kickers and collimator in the damping ring.
Samples in the form of transverse slices of rods and optical fiber preforms made from the high-hydroxyl KU-1 and low-hydroxyl KS-4V silica by the plasma outside deposition (POD) method are {gamma}-irradiated to a dose of {approx}1 MGy (SiO{sub 2}). Next, the radial dependences of the radiation-induced nonbridging oxygen hole center (NBOHC) and E'-center (three-coordinated silicon) in the samples are constructed by measuring the amplitudes of their 4.8 and 5.8 eV absorption bands, respectively. Based on the analysis of these radial dependences and considering the temperature and duration of the preirradiation heat treatment of the rods and preforms at the POD-installation, we determine the ratio of the oscillator strengths of the above bands and the microscopic thermoinduced processes occurring during preform fabrication and producing precursors of the radiation-induced NBOHC and E'-center. These processes are found to be associated with the escape of either H{sub 2} or H{sub 2}O from neighboring hydroxyl groups, and, therefore, can occur in high-hydroxyl silica only. It is concluded that enhancement of the radiation resistance of high-hydroxyl silica optical fibers requires decreasing the temperature and duration of the preform fabrication process, in particular, changing from the POD-technology to the low-temperature plasmachemical vapor deposition (PCVD) or surface PCVD (SPCVD)-technology.
Noise in medical images is recognized as an important factor that determines the image quality. Image noise is characterized by noise power spectrum (NPS). We compared two methods of NPS determination namely the methods of Wagner and Dobbins on Lanex Regular TMG screen-film system and Hologic Lorad Selenia full field digital mammography system, with the aim of choosing the better method to use. The methods differ in terms of various parametric choices and algorithm implementations. These parameters include the low pass filtering, low frequency filtering, windowing, smoothing, aperture correction, overlapping of region of interest (ROI), length of fast Fourier transform, ROI size, method of ROI normalization, and slice selection of the NPS. Overall, the two methods agreed to the practical value of noise power spectrum between 10{sup -3}-10{sup -6} mm{sup 2} over spatial frequency range 0-10 mm{sup -1}.
GYRO is used to examine the perturbed magnetic field structure generated by electromagnetic gyrokinetic simulations of the CYCLONE base case as {beta}{sub e} is varied from 0.1% to 0.7%, as investigated by J. Candy [Phys. Plasmas 12, 072307 (2005)]. Poincare surface of section plots obtained from integrating the self-consistent magnetic field demonstrates widespread stochasticity for all nonzero values of {beta}{sub e}. Despite widespread stochasticity of the perturbed magnetic fields, no significant increase in electron transport is observed. The magnetic diffusion, d{sub m}[A. B. Rechester and M. N. Rosenbluth, Phys. Rev. Lett 40, 38 (1978)], is used to quantify the degree of stochasticity and related to the electron heat transport for hundreds of time slices in each simulation.
We present a direct current slice imaging study of tetrachloroethylene (C{sub 2}Cl{sub 4}) photodissociation, probing the resulting ground state Cl ({sup 2}P{sub 3/2}) and spin-orbit excited state Cl* ({sup 2}P{sub 1/2}) products. We report photofragment images, total translational energy distributions and the product branching ratio of Cl*/Cl following dissociation at 235 and 202 nm, obtained using a two-color reduced-Doppler dissociation/probe. Near 235 nm, the Cl translational energy distribution shows a peak at the limit of the available energy, indicating a direct dissociation through a {sigma}*(C-Cl) (leftarrow){pi} (C=C) transition, which is superimposed on a broader underlying distribution. The ground state Cl image and associated translational energy distribution at 202 nm is broad and peaked at lower energy, suggesting either internal conversion to the ground state or a lower excited state prior to dissociation. The Cl* images are similarly broad at both wavelengths. The branching ratio is presented as a function of recoil energy, but after integration shows a near-statistical average of Cl:Cl* as 70:30 at both wavelengths. All the images are largely isotropic, with anisotropy parameters ({beta}) of 0.05 {+-} 0.03.
ICl photolysis in the ultraviolet region of the spectrum (235-265 nm) is studied using the Slice Imaging technique. The Cl*({sup 2}P{sub 1/2})/Cl({sup 2}P{sub 3/2}) and the I*({sup 2}P{sub 1/2})/I({sup 2}P{sub 3/2}) branching ratio between the I({sup 2}P{sub 3/2}) + Cl({sup 2}P{sub 3/2})/Cl*({sup 2}P{sub 1/2}) and I*({sup 2}P{sub 1/2}) + Cl({sup 2}P{sub 3/2})/Cl*({sup 2}P{sub 1/2}) channels is extracted from the respective iodine and chlorine photofragment images. We find that ground state chlorine atoms (Cl({sup 2}P{sub 3/2})) are formed nearly exclusively with excited state iodine atoms (I*({sup 2}P{sub 1/2})), while excited spin-orbit chlorine atoms (Cl*({sup 2}P{sub 1/2})) are concurrently produced only with ground state iodine atoms (I({sup 2}P{sub 3/2})). We conclude that photolysis of ICl in this UV region is a relatively ''clean'' source of spin-orbit excited chlorine atoms that can be used in crossed molecular beam experiments.
In order to meet the different requirements of applications in synchrotron radiation and plasma diagnosis in China, focusing and imaging optics based on Kirkpatrick-Baez (KB) mirrors, compound refractive lenses (CRLs), and multilayer Laue lenses (MLLs) were studied in our lab. A one-dimensional KB microscope using mirrors with a dual-periodic multilayer coating was developed. The multilayer mirror can reflect both 4.75 keV (Ti K-line) and 8.05 keV (Cu K-line) simultaneously, which makes alignment easier. For hard x-ray microscopy, CRL was studied. Using a SU-8 resist planar parabolic CRL, a focal line of 28.8-{mu}m width was obtained. To focus hard x-rays to nanometer levels efficiently, an MLL was fabricated using a WSi{sub 2}/Si multilayer. The MLL consists of 324 alternating WSi{sub 2} and Si layers with a total thickness of 7.9 {mu}m. (Recently, a much thicker multilayer has been deposited with a layer number of n = 1582 and a total thickness of 27 {mu}m.) After deposition, the sample was sliced and polished into an approximate ideal aspect ratio (depth of the zone plate to outmost layer thickness); the measured results show an intact structure remains, and the surface roughness of the cross section is about 0.4 nm after grinding and polishing processes.