Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Up-regulation of CHAF1A, a poor prognostic factor, facilitates cell proliferation of colon cancer

Highlights: • We identified that CHAF1A was up-regulated in colon tumor mucosa in TMA. • The expression pattern of CHAF1A was validated with qPCR and western-blot. • CHAF1A overexpression is an independent indicator for poor colon cancer survival. • CHAF1A facilitates cell proliferation of colon cancer both in vitro and in vivo. - Abstract: Deregulation of chromatin assembly factor 1, p150 subunit A (CHAF1A) has recently been reported to be involved in the development of some cancer types. In this study, we identified that the frequency of positive CHAF1A staining in primary tumor mucosa (45.8%, 93 of 203 samples) was significantly elevated compared to that in paired normal mucosa (18.7%, 38 of 203 samples). The increased expression was strongly associated with cancer stage, tumor invasion, and histological grade. The five-year survival rate of patients with CHAF1A-positive tumors was remarkably lower than that of patients with CHAF1A-negative tumors. Colon cancer cells with CHAF1A knockdown exhibited decreased cell growth index, reduction in colony formation ability, elevated cell apoptosis rate as well as impaired colon tumorigenicity in nude mice. Hence, CHAF1A upregulation functions as a poor prognostic indicator of colon cancer, potentially contributing to its progression by mediating cancer cell proliferation.

60 APPLIED LIFE SCIENCES↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volatiles in High-K Lunar Basalts

Chlorine is an unusual isotopic system, being essentially unfractionated ((delta)Cl-37 approximately 0 per mille ) between bulk terrestrial samples and chondritic meteorites and yet showing large variations in lunar (approximately -4 to +81 per mille), martian, and vestan (HED) samples. Among lunar samples, the volatile-bearing mineral apatite (Ca5(PO4)3[F,Cl,OH]) has been studied for volatiles in K-, REE-, and P (KREEP), very high potassium (VHK), low-Ti and high-Ti basalts, as well as samples from the lunar highlands. These studies revealed a positive correlation between in-situ (delta)Cl-37 measurements and bulk incompatible trace elements (ITEs) and ratios. Such trends were interpreted to originate from Cl isotopic fractionation during the degassing of metal chlorides during or shortly after the differentiation of the Moon via a magma ocean. In this study, we investigate the volatile inventories of a group of samples for which new-era volatile data have yet to be reported - the high-K (greater than 2000 ppm bulk K2O), high-Ti, trace element-rich mare basalts. We used isotope imaging on the Cameca NanoSIMS 50L at JSC to obtain the Cl isotopic composition [((Cl-37/(35)Clsample/C-37l/(35)Clstandard)-1)×1000, to get a value in per thousand (per mille)] which ranges from approximately -2.7 +/- 2 per mille to +16.1 +/- 2 per mille (2sigma), as well as volatile abundances (F & Cl) of apatite in samples 10017, 10024 & 10049. Simply following prior models, as lunar rocks with high bulk-rock abundances of ITEs we might expect the high-K, high-Ti basalts to contain apatite characterized by heavily fractionated (delta)Cl-37 values, i.e., Cl obtained from mixing between unfractionated mantle Cl (approximately 0 per mille) and the urKREEP reservoir (possibly fractionated to greater than +25 per mille.). However, the data obtained for the studied samples do not conform to either the early degassing or mixing models. Existing petrogentic models for the origin of the high-K, high-Ti basalts do not include urKREEP assimilation into their LMO cumulate sources. Therefore, Cl in these basalts either originated from source region heterogeneity or through assimilation or metasomatism by volatile and incompatible trace element rich materials. The new data presented here could provide evidence for the existence of region(s) in the lunar interior that are ITE-enriched and contain Cl that does not share isotopic affinities with lunar urKREEP, possibly representing the composition of the purported 'neuKREEP'.

Barnes, Jessica J.↗

Correlations of Apparent Cellulose Crystallinity Determined by XRD, NMR, IR, Raman, and SFG Methods

Although the cellulose crystallinity index (CI) is used widely, its limitations have not been adequately described. In this study, the CI values of a set of reference samples were determined from X-ray diffraction (XRD), nuclear magnetic resonance (NMR), and infrared (IR), Raman, and vibrational sum frequency generation (SFG) spectroscopies. The intensities of certain crystalline peaks in IR, Raman, and SFG spectra positively correlated with the amount of crystalline cellulose in the sample, but the correlation with XRD was nonlinear as a result of fundamental differences in detection sensitivity to crystalline cellulose and improper baseline corrections for amorphous contributions. It is demonstrated that the intensity and shape of the XRD signal is affected by both the amount of crystalline cellulose and crystal size, which makes XRD analysis complicated. It is clear that the methods investigated show the same qualitative trends for samples, but the absolute CI values differ depending on the determination method. This clearly indicates that the CI, as estimated by different methods, is not an absolute value and that for a given set of samples the CI values can be compared only as a qualitative measure.

09 BIOMASS FUELS↗

Structural and Magnetic Studies of Nano-crystalline Ferrites MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) Synthesized Via Citrate Gel Autocombustion Method

Nano-crystalline ferrites with the chemical formula MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) were synthesized via autocombustion route with citric acid as fuel. The ratio of citric acid to metal nitrate was taken as 1:1. The synthesized samples were characterized by powder X-ray diffraction and far-IR spectroscopy. The measured lattice constants and observed characteristic IR absorption bands of all samples were in good agreement with the reported values and showed the formation of a cubic spinel structure. The crystallite sizes of all samples were determined using high-intensity peaks and a W-H plot. The crystallite sizes of all samples were observed to be in the range of 16–26 nm with the least crystallite size of 16.8 nm for copper ferrite. All structural parameters were calculated using an experimental lattice constant and an oxygen positional parameter and correlated with far-IR results. Zinc and copper owing to their large cation radii showed the expansion of the lattice in view of the oxygen positional parameter. Magnetic measurements were carried out using a vibrating sample magnetometer at room temperature, and parameters such as saturation magnetization, coercivity, remanence, squareness ratio, and Bohr magnetons were calculated. Among all synthesized nano-ferrites, cobalt nano-ferrite showed the highest saturation magnetization of 41 emu/g, whereas zinc ferrite displayed a low saturation magnetization value of 12.87 emu/g.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolution Performance of HERA-B Lead-Glass Calorimeters

In preparation of upcoming 12GeV experiments at Thomas Jefferson National Accelerator Facility it is necessary to upgrade existing systems or install new detectors. As part of this effort, an array of lead-glass sampling calorimeters is need for use in the GEP-5 experiment. A sampling calorimeter can be used to determine the energy and spatial position of a high energy particle that enters it while simultaneously stopping the particle. To determine the appropriate construction to meet the needs of upcoming experiments, it was necessary to take an existing model and confirm its energy and position resolution. This model could then be confirmed as an option for the final construction, or used as a starting point to design a better detector. For our test we obtained ten lead-glass calorimeters used in HERA-B and tested them in End Station A at SLAC. I will report on our findings for the HERA-B lead-glass sampling calorimeters. I will cover the results of both the energy and position resolutions as well as the methods used to determine these quantities.

Losada, Anthony↗

Precision lattice parameter determination from transmission diffraction of thick specimens with irregular cross sections

Accurate determination of lattice parameters from X-ray diffraction requires that the diffraction angles be measured very precisely, and significant errors result if the sample–detector separation differs from that assumed. Transmission diffraction from bones, which have a complex cross section and must be left intact, is a situation where this separation is difficult to measure and it may differ from position to position across the specimen. Here, this article describes a method for eliminating the effect of variable sample cross section. Diffraction patterns for each position on the specimen are collected before and after 180° rotation about an axis normal to the cross section of interest. This places the centroid of the diffracting mass at the center of rotation and provides the absolute lattice parameters from the average apparent lattice parameters at the two rotation angles. Diffraction patterns were collected across the cross section of three specimens: a 3D-printed elliptical cylinder of Hyperelastic Bone (HB), which is composed primarily of synthetic hydroxyapatite (hAp), a 3D-printed HB model of the second metacarpal bone (Mc2), and a modern human Mc2 containing nanocrystalline carbonated apatite (cAp). Rietveld refinement was used to determine precise unit-cell parameters a apparent and c apparent for each pattern of each scan, and these values determined the actual average < a > and < c > for each sample. In conclusion, the results indicate that the 0°/180° rotation method works well enough to uncover variations approaching 1 × 10 -3 Å in cAp unit-cell parameters in intact bones with irregular cross sections.

36 MATERIALS SCIENCE↗

Low vibration high numerical aperture automated variable temperature Raman microscope

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2 Se 3 and V 2 O 3 , which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Load partitioning between ferrite/martensite and dispersed nanoparticles of a 9Cr ferritic/martensitic (F/M) ODS steel at high temperatures

In this study, a high-energy synchrotron radiation X-ray technique was used to investigate the tensile deformation processes of a 9Cr-ODS ferritic/martensitic (F/M) steel at different temperatures. Two minor phases within the 9Cr-ODS F/M steel matrix were identified as Y2Ti2O7 and TiN by the high-energy X-ray diffraction, and confirmed by the analysis using energy dispersive X-ray spectroscopy (EDS) of scanning transmission electron microscope (STEM). The lattice strains of the matrix and particles were measured through the entire tensile deformation process. During the tensile tests, the lattice strains of the ferrite/martensite and the particles (TiN and Y2Ti2O7) showed a strong temperature dependence, decreasing with increasing temperature. Analysis of the internal stress at three temperatures showed that the load partitioning between the ferrite/martensite and the particles (TiN and Y2Ti2O7) was initiated during sample yielding and reached to a peak during sample necking. At three studied temperatures, the internal stress of minor phases (Y2Ti2O7 and TiN) was about 2 times that of F/M matrix at yielding position, while the internal stress of Y2Ti2O7 and TiN reached about 4.5-6 times and 3-3.5 times that of the F/M matrix at necking position, respectively. It indicates that the strengthening of the matrix is due to minor phases (Y2Ti2O7 and TiN), especially Y2Ti2O7 particles. Although the internal stresses of all phases decreased with increasing temperature from RT to 600 degrees C, the ratio of internal stresses of each phase at necking position stayed in a stable range (internal stresses of Y2Ti2O7 and TiN were about 4.5-6 times and 3-3.5 times of that of F/M matrix, respectively). The difference between internal stress of the F/M matrix and the applied stress at 600 degrees C is slightly lower than those at RI and 300 degrees C, indicating that the nanoparticles still have good strengthening effect at 600 degrees C. (C) 2015 Elsevier B.V. All rights reserved.

Microstructure↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗

Responses to Nonconformances, AIHA Onsite Assessment August 29-31, 2022

A nonconformance report (NCR) was not generated to document the original Beryllium (Be) positive result being changed to negative due to an oversight by the lab. The sample was re-analyzed on the Agilent ICP-OES which includes software to deal with interferences and resulted in a negative for Be. In order to determine the cause of the false positive, which was originally thought to be due to the Titanium interference in the sample, the laboratory analyzed a blank and a reporting limit standard with 5 ppm and 10 ppm of Titanium added in. These were analyzed on the Perkin Elmer ICP 5 instrument to see if the positive Be was reproducible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury biomagnification and the trophic structure of the ichthyofauna from a remote lake in the Brazilian Amazon

The present study assesses mercury biomagnification and the trophic structure of the ichthyofauna from the Puruzinho Lake, Brazilian Amazon. In addition to mercury determination, the investigation comprised the calculation of Trophic Magnification Factor (TMF) and Trophic Magnification Slope (TMS), through the measurements of stable isotopes of carbon (δ{sup 13}C) and nitrogen (δ{sup 15}N) in fish samples. These assessments were executed in two different scenarios, i.e., considering (1) all fish species or (2) only the resident fish (excluding the migratory species). Bottom litter, superficial sediment and seston were the sources used for generating the trophic position (TP) data used in the calculation of the TMF. Samples from 84 fish were analysed, comprising 13 species, which were categorized into four trophic guilds: iliophagous, planktivorous, omnivorous and piscivorous fish. The δ{sup 13}C values pointed to the separation of the ichthyofauna into two groups. One group comprised iliophagous and planktivorous species, which are linked to the food chains of phytoplankton and detritus. The other group was composed by omnivorous and piscivorous fish, which are associated to the trophic webs of phytoplankton, bottom litter, detritus, periphyton, as well as to food chains of igapó (blackwater-flooded Amazonian forests). The TP values suggest that the ichthyofauna from the Puruzinho Lake is part of a short food web, with three well-characterized trophic levels. Mercury concentrations and δ{sup 13}C values point to multiple sources for Hg input and transfer. The similarity in Hg levels and TP values between piscivorous and planktivorous fish suggests a comparable efficiency for the transfer of this metal through pelagic and littoral food chains. Regarding the two abovementioned scenarios, i.e., considering (1) the entire ichthyofauna and (2) only the resident species, the TMF values were 5.25 and 4.49, as well as the TMS values were 0.21 and 0.19, respectively. These findings confirm that Hg biomagnifies through the food web of Puruzinho Lake ichthyofauna. The migratory species did not significantly change mercury biomagnification rate in Puruzinho Lake; however, they may play a relevant role in Hg transport. The biomagnification rate (TMS value) in Puruzinho Lake was higher than the average values for its latitude, being comparable to TMS values of temperate and polar systems (marine and freshwater environments). - Highlights: • Mercury biomagnified in food web of a remote Amazonian lake. • δ{sup 13}C and δ{sup 15}N values suggest multiple Hg sources in food web with 3 trophic levels. • We found similar Hg transfer efficiencies in pelagic and littoral food chains. • Migration may influence the trophic structure assessment performed with δ{sup 15}N. • The migrating species did not significantly alter the biomagnification calculation.

54 ENVIRONMENTAL SCIENCES↗

Chromatin structure predicts survival in glioma patients

The pathological changes in epigenetics and gene regulation that accompany the progression of low-grade to high-grade gliomas are under-studied. The authors use a large set of paired atac-seq and RNA-seq data from surgically resected glioma specimens to infer gene regulatory relationships in glioma. Thirty-eight glioma patient samples underwent atac-seq sequencing and 16 samples underwent additional RNA-seq analysis. Using an atac-seq/RNA-seq correlation matrix, atac-seq peaks were paired with genes based on high correlation values (|r 2 | > 0.6). Samples clustered by IDH1 status but not by grade. Surprisingly there was a trend for IDH1 mutant samples to have more peaks. The majority of peaks are positively correlated with survival and positively correlated with gene expression. Constructing a model of the top six atac-seq peaks created a highly accurate survival prediction model (r 2 = 0.68). Four of these peaks were still significant after controlling for age, grade, pathology, IDH1 status and gender. Grade II, III, and IV (primary) samples have similar transcription factors and gene modules. However, grade IV (recurrent) samples have strikingly few peaks. Patient-derived glioma cultures showed decreased peak counts following radiation indicating that this may be radiation-induced. This study supports the notion that IDH1 mutant and IDH1 wildtype gliomas have different epigenetic landscapes and that accessible chromatin sites mapped by atac-seq peaks tend to be positively correlated with expression. The data in this study leads to a new model of treatment response wherein glioma cells respond to radiation therapy by closing open regions of DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Urinary levels of triclosan and triclocarban in several Asian countries, Greece and the USA: Association with oxidative stress

Highlights: • Triclosan and triclocarban were analyzed in 430 urine samples collected from 9 countries. • Triclosan concentrations as high as 1600 ng/mL were found in urine. • Age and gender related differences in triclosan levels were minimal. • TCC levels were marginally correlated with the oxidative stress marker, 8OHdG. Triclosan (TCS) and Triclocarban (TCC) are widely used as antimicrobial preservatives in personal care products (PCPs). Because of their potential for endocrine disrupting effects, human exposure to these chemicals is a concern. Biomonitoring studies of human exposure to TCS and TCC have shown widespread exposure of populations in western European countries and the USA. However, exposure to TCC and TCS by populations in Asian countries is less well known. In this study, concentrations of TCS and TCC were determined in human urine collected from seven Asian countries (China, India, Korea, Kuwait, Japan, Saudi Arabia, and Vietnam), and Greece and the USA. A total of 430 urine samples were analyzed for TCS and TCC, of which 355 (83%) and 82 (19%), respectively, contained measurable levels of these chemicals. The overall geometric mean [GM] concentrations of TCS and TCC, were 1.36 and 0.03 ng/mL, respectively. The highest mean concentration of TCS was found in urine from China (100 ng/mL) and the lowest concentration was found in urine from Vietnam (2.34 ng/mL). We also analyzed urinary 8-OHdG, a marker of oxidative stress, to elucidate the association with TCS and TCC levels for samples from Saudi Arabia (n=130) and a positive correlation between Ln-transformed TCC levels and 8-OHdG was found, although this was not statistically significant. This is the first study to report urinary levels of TCS and TCC in several Asian countries, especially for Vietnam, Kuwait, and Japan.

54 ENVIRONMENTAL SCIENCES↗

Crystal structures and microwave dielectric properties of Zn,W co-substituted BaTiO{sub 3} perovskite ceramics

Zn,W co-substituted BaTiO{sub 3} perovskite ceramics with compositions of Ba[Ti{sub 1-x}(Zn{sub 1/2}W{sub 1/2}){sub x}]O{sub 3} (x=0.40-1.00) were synthesized by the conventional solid-state reaction method and studied by X-ray diffraction and dielectric measurements. Their structures transferred from cubic (x=0.40) with space group Pm3{sup Macron }m to hexagonal (x=0.55-0.60) with P6{sub 3}/mmc, and then to cubic double pervoskite (x=1.00) with Fm3{sup Macron }m. The refinement results of sample (x=0.60) revealed that the negative and positive charge centers are not consistent with each other in the face-sharing oxygen octahedra. Compared with the cubic perovskites, the hexagonal ones had the increased quality factor (Q Multiplication-Sign f), the decreased dielectric constant ({epsilon}{sub r}), and especially the near-zero temperature coefficient of resonant frequency ({tau}{sub f}), whose absolute values were less than 5 ppm/ Degree-Sign C. The relationships between structures and properties were discussed. - Graphical abstract: The departure of the negative and positive charge centers in the face-sharing oxygen octahedra of hexagonal unit cell. Highlights: Black-Right-Pointing-Pointer A phase transition from simple cubic to hexagonal and then to cubic double pervoskite occurred. Black-Right-Pointing-Pointer Refinement results prove that spontaneous dipoles present in face-sharing oxygen octahedra. Black-Right-Pointing-Pointer Hexagonal perovskites had higher Q Multiplication-Sign f, nearer-zero {tau}{sub f}, and lower {epsilon}{sub r} than the cubic ones. Black-Right-Pointing-Pointer On the presence of the hexagonal perovskite, |{tau}{sub f}| was less than 5 ppm/ Degree-Sign C.

36 MATERIALS SCIENCE↗