Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Field Evaluation of the Restorative Capacity of the Aquifer Downgradient of a Uranium In-Situ Recovery Mining Site (Rev. 1)

A two-part field study was conducted in Smith Ranch-Highland in-situ recovery (ISR) near Douglas, Wyoming, to evaluate the restorative capacity of the aquifer downgradient (i.e., hydrologically downstream) of a Uranium ISR mining site with respect to the transport of uranium and other potential contaminants in groundwater after mining has ceased. The study was partially conducted by checking the Uranium content and the alkalinity of separate wells, some wells had been restored and others had not. A map and in-depth procedures of the study are included.

54 ENVIRONMENTAL SCIENCES↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm 2 , where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

59 BASIC BIOLOGICAL SCIENCES↗

Bioelectrochemical Integration of Waste Heat Recovery, Waste-to- Energy Conversion, and Waste-to-Chemical Conversion with Industrial Gas and Chemical Manufacturing Processes

Many U.S. manufacturing facilities generate unrecovered, low-grade waste heat, and also generate or are located near organic-content waste effluents. Bioelectrochemical systems, such as microbial fuel cells and microbial electrolysis cells, provide a means to convert organic-content effluents into electric power and useful chemical products. A novel biochemical electrical system for industrial manufacturing processes uniquely integrates both waste heat recovery and waste effluent conversion, thereby significantly reducing manufacturing energy requirements. This project will enable the further development of this technology so that it can be applied across a wide variety of US manufacturing segments, including the chemical, food, pharmaceutical, refinery, and pulp and paper industries. It is conservatively estimated that adoption of this technology could provide nearly 40 TBtu/yr of energy, or more than 1% of the U.S. total industrial electricity use, while reducing CO 2 emissions by more than 6 million tons per year. Commercialization of this technology will make a significant contribution to DOE’s Industrial Technology Program goals for doubling energy efficiency and providing a more robust and competitive domestic manufacturing base.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Post-Closure Report for Closed Resource Conservation and Recovery Act Corrective Action Units, Nevada National Security Site, Nevada: For Fiscal Year 2015 (October 2014–September 2015), Revision 0

This report serves as the combined annual report for post-closure activities for the following closed corrective action units (CAUs); CAU 90, Area 2 Bitcutter Containment; CAU 91, Area 3 U-3fi Injection Well; CAU 92, Area 6 Decon Pond Facility; CAU 110, Area 3 WMD U-3ax/bl Crater; CAU 111, Area 5 WMD Retired Mixed Waste Pits; and CAU 112, Area 23 Hazardous Waste Trenches. This report covers fiscal year 2015 (October 2014 through September 2015). The post-closure requirements for these sites are described in Resource Conservation and Recovery Act Permit Number NEV HW0101 and are summarized in each CAU-specific section in Section 1.0 of this report. The results of the inspections, a summary of maintenance activities, and an evaluation of monitoring data are presented in this report.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Mark-18A (Mk-18A) Target Material Recovery Program Product Acceptance Criteria

The Mk-18A Target Material Recovery Program (MTMRP) was established in 2015 to preserve the unique materials, e.g. 244 Pu, in 65 previously irradiated Mk-18A targets for future use. This program utilizes existing capabilities at SRS and Savannah River National Laboratory (SRNL) to process targets, recover materials from them, and to package the recovered materials for shipping to ORNL. It also utilizes existing capabilities at ORNL to receive and store the recovered materials, and to provide any additional processing of the recovered materials or residuals required to prepare them for future beneficial use. The MTMRP is presently preparing for the processing of these valuable targets which is expected to begin in ~2019. As part of the preparations for operations, this report documents the preliminary acceptance criteria for the plutonium and heavy curium materials to be recovered from the Mk-18A targets at SRNL for transport and storage at ORNL. These acceptance criteria were developed based on preliminary concepts developed for processing, transporting, and storing the recovered Mk-18A materials. They will need to be refined as these concepts are developed in more detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ER@CEBAF: A test of 5-pass energy recovery at CEBAF

Jefferson Lab personnel have broad expertise in the design, commissioning, and operation of multiple energy recovery linacs (ERLs): the CEBAF Front-End Test (early 1990s), CEBAF-ER (2003), the IR Free Electron Laser (FEL) Demo, the IR FEL Upgrade, and the UV FEL Driver (1997-2014). Continued development of this core competency has led to this collaborative proposal to explore the forefronts of ERL technology at high energy in a unique expansion of CEBAF capability to a 5-pass ERL with negligible switchover time and programmatic impact to the CEBAF physics program. Such a capability would enable world-class studies of open issues in high-energy ERL beam dynamics that are relevant to future facilities such as electron-ion colliders (EICs). This proposal requests support from the CEBAF Program Advisory Committee to seek funding for hardware installation, and a prospective 12 days of beam time circa Fall 2018 for commissioning this high-energy multi-pass ERL experiment in CEBAF.

43 PARTICLE ACCELERATORS↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

59 BASIC BIOLOGICAL SCIENCES↗

Surface and Airborne Monitoring Technology for Detecting Geologic Leakage in a CO 2 -Enhanced Oil Recovery Pilot, Anadarko Basin, Texas

Surface and airborne gas monitoring programs are becoming an important part of environmental protection in areas favorable for subsurface storage of carbon dioxide. Understanding structural architecture and its effects on the flux of fluids, specifically CO 2 and CH 4 , in the shallow subsurface and atmosphere is helping design and implement next generation monitoring technologies, including unmanned aerial vehicles (UAVs). An important aspect of this research is using subsurface fracture data to inform the design of flight pathways for UAVs in the Farnsworth Oil Unit of the Anadarko Basin. The target zone for CO 2 storage and enhanced oil recovery in the Farnsworth Oil Unit is in the upper Morrow sandstone at subsurface depths greater than 2,000 m. Field study reveals that sandstone and chert in the High Plains Aquifer contain numerous joints that provide crucial insight into aquifer architecture and subsurface flow pathways. Properties of more than 1,700 joints were measured in the field and in high-resolution satellite images. Two distinctive joint systems interpreted as a conjugate pair were identified in the study area. Joint spacing follows a log-normal statistical scaling rule. These fractures appear to be the product of an E-NE regional compressive stress and may have a significant effect on flow in the High Plains Aquifer system. Based on the results of this research, design of UAV flight paths should be oblique to fractures in a way that maximizes the likelihood of CO 2 and CH 4 flux from of systematic joints and cross joints. Detection of leaks either from subsurface seal failures or surface equipment problems is important to insure that stored CO 2 is not being lost to the atmosphere. In the case of surface leaks, costs go up and injection efficiency goes down. Surface leaks are often short term caused by seal leaks, pop off valves, or other equipment failure modes. In either case, CO 2 is released to the atmosphere. This projects primary goal was to explore the use of low cost sensors coupled with the appropriate hardware and software to produce a low cost system capable of detecting both long and short term leaks. In addition, an aerial system was designed to measure the CO 2 and CH 4 distributions above the surface. Both the ground and UAV based systems were designed, tested and deployed in the Farnsworth field.

02 PETROLEUM↗

Resource Conservation and Recovery Act General Contingency Plan for Hazardous Waste Treatment, Storage, and Disposal Units at the Y-12 National Security Complex. Revision 12

This document, Y/TS-1015/R12, Resource Conservation and Recovery Act General Contingency Plan for Hazardous Waste Treatment, Storage, and Disposal Units at the Y-12 National Security Complex, is for reference purposes. It is a consolidation of the August 10, 2018, versions of Attachment 6, “Contingency Plan,” from Tennessee Hazardous Waste Management Permits TNHW-122 and TNHW-127. It is not intended to supersede any requirements in these permits and any differences are unintentional. The decision to implement this contingency plan, as part of the Emergency Plan, depends upon whether an imminent or actual incident involving a RCRA treatment, storage, or disposal unit could threaten human health or the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Residential Heat Recovery Ventilation

Heat recovery ventilators (HRVs) save energy by recovering heat that would otherwise be exhausted as part of energy code-mandated mechanical ventilation systems. Residential HRVs can be life cycle cost effective depending on equipment/installation costs and the severity of the climate. This brief evaluates HRV cost effectiveness in the context of building energy codes to identify the climate zones in which a code might reasonably require residential HRVs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Near-Term Projections of CO 2 Utilization for Enhanced Oil Recovery

In 2013 a total of 113 CO 2 -EOR projects inject 3.1 billion cubic feet per day (Bcfd) (60 million metric tons (MMmt) per year) of CO 2 for enhanced oil recovery in the United States. The associated crude oil production in 2012 was 282,000 barrels per day. Based on the increased volumes of CO 2 supplies, the completion of major CO 2 pipelines, and the announced new, large-scale CO 2 -EOR floods, production of crude oil from CO 2 -EOR floods is forecast to grow significantly, reaching 615,000 barrels per day from at least 124 active CO 2 floods by year 2020. While the Permian Basin remains the largest CO 2 -EOR oil producer, much of the growth occurs in the Gulf Coast, the Rockies, and the Mid-Continent.

03 NATURAL GAS↗

Improving Domestic Energy Security and Lowering CO 2 Emissions with 'Next Generation' CO 2 -Enhanced Oil Recovery (CO 2 -EOR)

NETL has revised its national resource assessment for carbon dioxide enhanced oil recovery (CO 2 EOR). Under a current technology scenario, 1,200 reservoirs in the lower 48 states are amenable to CO 2 EOR. At an assumed crude oil market price of $85 per barrel, these reservoirs represent 24 billion barrels of economic reserves. Under a next generation scenario the economic supply from CO 2 EOR increases to 60 billion barrels. The resource assessment unveils a strong dependence on CO 2 capture technology, as the equivalent of 60 - 90 GW of coal-fired plants with 90% capture will be needed to supply EOR floods.

03 NATURAL GAS↗

Report on the recovery of legacy 1997-1998 Depth-of-Burial / Tunnel-and-Hole-Closure explosion data from the Kazakhstan former Soviet nuclear test site, Semipalatinsk.

In 1996, negotiations between the National Nuclear Center of the Republic of Kazakhstan (NNC), the U.S. Defense Special Weapons Administration (DSWA) and the U.S. Department of Energy led to an agreement for a joint series of experiments at the former Soviet nuclear test site Semipalatinsk (STS). These experiments had a dual purpose: to close holes and tunnels originally created for the purpose of testing nuclear weapons, and to characterize explosive sources at a former nuclear test site. This report covers the recovery of legacy data from the experiments conduct in 1997 and 1998. Two teams collected data. Los Alamos National Laboratory (LANL), in collaboration with the NNC, collected the near-source (local) data out to approximately 20 km. Lamont-Doherty Earth Observatory (LDEO), with funding from Lawrence Livermore Laboratory (LLNL), also in collaboration with NNC, collected regional data, 200 – 1000 km distant, leveraging the KZ regional seismic network that LDEO had recently installed in collaboration with NNC. The two teams also worked together to some extent, regarding instrumentation and planning. This report primarily addresses the near-source data collected by the LANL/NNC team.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Monitoring Volume: A Summary of Monitoring Studies Conducted in Niagaran Carbonate Pinnacle Reefs During Enhanced Oil Recovery with CO 2

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. During the MRCSP Phase III monitoring period, over 1 million metric tons of CO 2 was injected into ten Silurian-age (Niagaran) pinnacle reef reservoirs in Otsego County, Michigan that are operated by Core Energy, LLC. There are over 800 pinnacle reefs in northern Michigan, and collectively, these geologic features have sufficient capacity to store several hundred million metric tons of CO 2 . Moreover, most of the reefs are oil-bearing and went through primary production in the 1970s and 1980s; therefore, by injecting CO 2 into the reefs, there is a real opportunity to realize additional (enhanced) oil recovery (EOR) and to permanently store CO 2 after EOR. A key objective of the MRCSP Phase III project is to evaluate the effectiveness of various technologies for monitoring CO 2 that has been injected into deep geologic formations. Monitoring may be required at CO 2 storage sites for a variety of reasons, including to meet UIC Class II (EOR sites) or Class VI (storage only sites) permit requirements or EPA greenhouse gas reporting rule requirements or to qualify for tax credits under the 45Q tax credit rule. The results of this monitoring study should prove useful to operators considering using carbonate pinnacle reefs of Northern Michigan for CO 2 storage.

01 COAL, LIGNITE, AND PEAT↗

IRAD-MPE Radiation Source Recovery (Day 4) [Slides]

The objective of this module is to review emergency response radiation detection equipment, operational and safety procedures, and best practices for planning that are required to conduct a successful radiological source recovery operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Blowdown Recovery System for Cooling Tower Water Treatment

From 2014-2017, the U.S. General Services Administration's (GSA's) average nationwide water rates increased 41%. Rapidly escalating costs, mandated water-reduction targets, and the fact that an average of 28% of commercial office building water use is associated with heating and cooling led the GSA Green Proving Ground program to select alternative water treatment technologies for in-field validation. This report summarizes the latest alternative water treatment evaluation completed in 2022 - a Blowdown Recovery System for Cooling Tower Water Treatment. This Green Proving Ground program project assessed the performance of an alternative water treatment system provided by Aqualogix for treating cooling tower blowdown at the Lloyd D. George U.S. Courthouse in Las Vegas, Nevada.

13 HYDRO ENERGY↗