Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Preliminary separation of galactic and cosmic microwave emission for the COBE Differential Microwave Radiometer

Preliminary models of microwave emission from the Milky Way Galaxy based on COBE and other data are constructed for the purpose of distinguishing cosmic and Galactic signals. Differential Microwave Radiometer (DMR) maps, with the modeled Galactic emission removed, are fitted for a quadrupole distribution. Autocorrelation functions for individual Galactic components are presented. When Galactic emission is removed from the DMR data, the residual fluctuations are virtually unaffected, and therefore they are not dominated by any known Galactic emission component.

Bennet, C. L.↗

Interpretation of the cosmic microwave background radiation anisotropy detected by the COBE Differential Microwave Radiometer

The large-scale cosmic background anisotropy detected by the COBE Differential Microwave Radiometer (DMR) instrument is compared to the sensitive previous measurements on various angular scales, and to the predictions of a wide variety of models of structure formation driven by gravitational instability. The observed anisotropy is consistent with all previously measured upper limits and with a number of dynamical models of structure formation. For example, the data agree with an unbiased cold dark matter (CDM) model with H0 = 50 km/s Mpc and Delta-M/M = 1 in a 16 Mpc radius sphere. Other models, such as CDM plus massive neutrinos (hot dark matter (HDM)), or CDM with a nonzero cosmological constant are also consistent with the COBE detection and can provide the extra power seen on 5-10,000 km/s scales.

Wright, E. L.↗

Far-Infrared Imaging Radiometer

Inexpensive far-infrared imaging radiometer contains 128 X 128-picture-element array of AlxGa1-xAs quantum-well detectors. Potentially useful in remote sensing from airborne platforms. Industrial applications include rapid thermal imaging of heat-sensitive components. Astronomical applications include imaging of planets and Sun.

Forrest, Kathrine↗

Microwave radiometer studies of atmospheric water over the oceans, volume 2

Since the Seasat carried the Scanning Multichannel Microwave Radiometer (SMMR) into space in July of 1978, shortly followed by the SMMR on Nimbus 7, which operated for almost a decade, a new type of data source on atmospheric water vapor and other meteorological parameters has been available for analysis of weather systems over the ocean. Since 1987, we have had the Scanning Multichannel Microwave/Imager (SSM/I) instrument on Defense Meteorological Satellites providing similar data. We present a collection of our work performed over the last years of the study.

Katsaros, Kristina B.↗

Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) PARM tape user's guide

The Scanning Multichannel Microwave Radiometer (SMMR) instrument, onboard the Nimbus-7 spacecraft, collected data from Oct. 1978 until Jun. 1986. The data were processed to physical parameter level products. Geophysical parameters retrieved include the following: sea-surface temperatures, sea-surface windspeed, total column water vapor, and sea-ice parameters. These products are stored on PARM-LO, PARM-SS, and PARM-30 tapes. The geophysical parameter retrieval algorithms and the quality of these products are described for the period between Nov. 1978 and Oct 1985. Additionally, data formats and data availability are included.

Han, D.↗

Phased array feed design technology for Large Aperture Microwave Radiometer (LAMR) Earth observations

An assessment of the potential and limitations of phased array antennas in space-based geophysical precision radiometry is described. Mathematical models exhibiting the dependence of system and scene temperatures and system sensitivity on phased array antenna parameters and components such as phase shifters and low noise amplifiers (LNA) are developed. Emphasis is given to minimum noise temperature designs wherein the LNA's are located at the array level, one per element or subarray. Two types of combiners are considered: array lenses (space feeds) and corporate networks. The result of a survey of suitable components and devices is described. The data obtained from that survey are used in conjunction with the mathematical models to yield an assessment of effective array antenna noise temperature for representative geostationary and low Earth orbit systems. Practical methods of calibrating a space-based, phased array radiometer are briefly addressed as well.

Schuman, H. K.↗

Output data formatter for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Output Data Formatter (ODF) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. It employs programmable logic devices to format and tag correlator data for transmission to Earth. After accepting 170 bits or correlator and error data in parallel, it appends an identification word and then serially passes the data to the Small Explorer Data System (SEDS) for transmission at a maximum rate of greater than 15 Mb/sec. Implemented with two reprogrammable field programmable gate arrays (FPGA's), each contained in a 132-pin plastic pin grid array (PGA) package, the design is cascadeable, fully testable, and low-power.

Chren, William A., Jr.↗

COBE Differential Microwave Radiometer (DMR) data processing techniques

The purpose of the Differential Microwave Radiometer (DMR) experiment on the Cosmic Background Explorer (COBE) satellite is to make whole-sky maps, at frequencies of 31.5, 53, and 90 GHz, of any departures of the Cosmic Microwave Background (CMB) from its mean value of 2.735 K. An elaborate software system is necessary to calibrate and invert the differential measurements, so as to make sky maps free from large scale systematic errors to levels less than a millionth of the CMB.

Jackson, P. D.↗

Daily quality assurance software for a satellite radiometer system

Six Differential Microwave Radiometers (DMR) on COBE (Cosmic Background Explorer) measure the large-angular-scale isotropy of the cosmic microwave background (CMB) at 31.5, 53, and 90 GHz. Quality assurance software analyzes the daily telemetry from the spacecraft to ensure that the instrument is operating correctly and that the data are not corrupted. Quality assurance for DMR poses challenging requirements. The data are differential, so a single bad point can affect a large region of the sky, yet the CMB isotropy requires lengthy integration times (greater than 1 year) to limit potential CMB anisotropies. Celestial sources (with the exception of the moon) are not, in general, visible in the raw differential data. A 'quicklook' software system was developed that, in addition to basic plotting and limit-checking, implements a collection of data tests as well as long-term trending. Some of the key capabilities include the following: (1) stability analysis showing how well the data RMS averages down with increased data; (2) a Fourier analysis and autocorrelation routine to plot the power spectrum and confirm the presence of the 3 mK 'cosmic' dipole signal; (3) binning of the data against basic spacecraft quantities such as orbit angle; (4) long-term trending; and (5) dipole fits to confirm the spacecraft attitude azimuth angle.

Keegstra, P. B.↗

Walsh function generator for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Walsh Function Generator (WFG) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. Implemented in a single Xilinx XC3020PC68-50 Field Programmable Gate Array (FPGA), it generates a user-programmable set of 32 consecutive Walsh Functions for noise cancellation in the analog circuitry of the Front-End Modules (FEM's). It is implemented in a 68-pin plastic leaded chip carrier (PLCC) package, is fully testable, and can be used for noise cancellation periods as small as 2 msec.

Chren, William A., Jr.↗

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

Measurement of oceanic wind vector using satellite microwave radiometers

A feasibility study of deriving both a wind speed and direction from microwave radiometer measurements of the ocean is presented. The study was based on the Special Sensor Microwave/Imager (SSM/I) measurements in conjunction with buoy reports from the National Data Buoy Center. It was found that the SSM/I minus the buoy wind speed difference is correlated with wind direction due to a wind direction signal in the brightness temperatures. When this wind direction signal is removed the rms difference between the SSM/I and buoy winds reduces to 1.3 m/s. The wind direction signal was used to make global, low-resolution maps of the monthly mean oceanic wind vector.

Wentz, Frank J.↗

COBE Differential Microwave Radiometers - Preliminary systematic error analysis

The techniques available for the identification and subtraction of sources of dynamic uncertainty from data of the Differential Microwave Radiometer (DMR) instrument aboard COBE are discussed. Preliminary limits on the magnitude in the DMR 1 yr maps are presented. Residual uncertainties in the best DMR sky maps, after correcting the raw data for systematic effects, are less than 6 micro-K for the pixel rms variation, less than 3 micro-K for the rms quadruple amplitude of a spherical harmonic expansion, and less than 30 micro-(K-squared) for the correlation function.

Kogut, A.↗

Cryogenic radiometers and intensity-stabilized lasers for Eos radiometric calibrations

Liquid helium-cooled electrical substitution radiometers (ESRs) provide irradiance standards with demonstrated absolute accuracy at the 0.01 percent level, spectrally flat response between the UV and IR, and sensitivity down to 0.1 nW/sq cm. We describe an automated system developed for NASA - Goddard Space Flight Center, consisting of a cryogenic ESR illuminated by servocontrolled laser beams. This system is designed to provide calibration of single-element and array detectors over the spectral range between 257nm in the UV to 10.6 microns in the IR. We also describe a cryogenic ESR optimized for black body calibrations that has been installed at NIST, and another that is under construction for calibrations of the CERES scanners planned for Eos.

Foukal, P.↗

Solar-diffuser panel and ratioing radiometer approach to satellite sensor on-board calibration

The use of a solar-diffuser panel is a desirable approach to the on-board absolute radiometric calibration of satellite multispectral sensors used for earth observation in the solar reflective spectral range. It provides a full aperture, full field, end-to-end calibration near the top of the sensor's dynamic range and across its entire spectral response range. A serious drawback is that the panel's reflectance, and the response of any simple detector used to monitor its reflectance may change with time. This paper briefly reviews some preflight and on-board methods for absolute calibration and introduces the ratioing-radiometer concept in which the radiance of the panel is ratioed with respect to the solar irradiance at the time the multispectral sensor is viewing the panel in its calibration mode.

Slater, Philip N.↗

Differential correction technique for removing common errors in gas filter radiometer measurements

The Measurement of Air Pollution from Satellites (MAPS) gas filter radiometer experiment was designed to measure CO mixing ratios in the earth's atmosphere. MAPS also measures N2O to provide a reference channel for the atmospheric emitting temperature and to detect the presence of clouds. In this paper we formulate equations to correct the radiometric signals based on the spatial and temporal uniformity of the N2O mixing ratio in the atmosphere. Results of an error study demonstrate that these equations reduce the error in inferred CO mixing ratios. Subsequent application of the technique to the MAPS 1984 data set decreases the error in the frequency distribution of mixing ratios and increases the number of usable data points.

Wallio, H. A.↗

Measurement of tropospheric carbon monoxide using gas filter radiometers

The measurement of tropospheric carbon monoxide with gas filter radiometers is examined on the basis of the MAPS experiment. The performance characteristics of an instrument that uses the MAPS detectors, broadband filters, and gas cells in a system similar to the GASCOFIL system described by Morrow and Nicholls (1985) is determined. The signal function for two carbon monoxide channels of the MAPS instrument as it was flown in 1981 is shown. The measurements of the lower pressure channel are weighted to a higher altitude. The signal function, when integrated over altitude and multiplied by the normalization constant, yields the value of the signal. Both signal functions approach zero at the top because the gas concentration approaches zero. The present data reduction technique assumes that there are no clouds in the field of view. If clouds are present, the inferred carbon monoxide mixing ratio is too high, and those points must be rejected from the data set.

Reichle, Henry G., Jr.↗

Transfer function considerations for the CERES scanning radiometer

The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer will determine the radiation budget of the Earth on a regional basis over a number of years. The error in the reconstructed field is used as a design criterion for selecting design parameters for the instrument. The reconstruction error is comprised of errors due to aliasing, blurring and radiance equivalent noise of the instrument, and can be evaluated in terms of the transfer function of the system.

Manalo, N.↗