Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESPIRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Intrafraction and Interfraction Tumor Motion Amplitude and Prediction Error for Different Liver Tumor Trajectories in Cyberknife Synchrony Tracking

To research the fiducial-based, real-time tracking intrafraction (during the fraction [intra-]) and interfraction (between fractions [inter-]) tumor respiration amplitude, motion trajectory, and prediction error and quantify their relationships for different types of motion trajectories during Cyberknife-based stereotactic ablation radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Lung Tumour Motion and Volume Size Dependencies Using Various Evaluation Measures

The purpose of the study was to assess internal target volume changes through the breathing cycle and associated tumour motion for lung patients and to establish possible correlations between different parameters. Respiration-induced volume changes with breathing cycle and the associated tumour motion were analyzed for 11 patients. Selected phases were the maximum and average intensity projections and the 10 phases of equal duration and separation obtained through the respiratory cycle. Tumour centre of mass (COM) motion planes were generated using least square fitting, and their angles and orientations were then compared between the cases studied. Trajectories that are composed by the points of COM location in different phases were identified, and their interrelation was assessed through different similarity measures. The results were used to determine if there is any correlation between parameters chosen and if the margins conventionally used for the planning target volume creation successfully encompassed lung tumour motion and volume change. The results show that the extent of tumour motion was related to its volume and location. The tumour displacement was predominantly left and inferior. Planar fitting to COM motion data through respiratory phases demonstrated some correlation in best fit motion plane positions between different data sets. In the plane fit comparison, for each patient, the lower root mean square error values showed that a good planar fit can be achieved for the COM motion path. The evaluation of the inhale and exhale trajectories may allow, for certain tumour locations and size, contouring on only inhalation or exhalation phases, knowing that tumour motion will be adequately covered on the other phases. Taking all the data into account and knowing the tumour size and location, a good estimate can be made of the motion plane position in the three-dimensional space and the required dosimetric margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided Radiotherapy

The ExacTrac X-Ray 6D image-guided radiotherapy (IGRT) system will be described and its performance evaluated. The system is mainly an integration of 2 subsystems: (1) an infrared (IR)-based optical positioning system (ExacTrac) and (2) a radiographic kV x-ray imaging system (X-Ray 6D). The infrared system consists of 2 IR cameras, which are used to monitor reflective body markers placed on the patient's skin to assist in patient initial setup, and an IR reflective reference star, which is attached to the treatment couch and can assist in couch movement with spatial resolution to better than 0.3 mm. The radiographic kV devices consist of 2 oblique x-ray imagers to obtain high-quality radiographs for patient position verification and adjustment. The position verification is made by fusing the radiographs with the simulation CT images using either 3 degree-of-freedom (3D) or 6 degree-of-freedom (6D) fusion algorithms. The position adjustment is performed using the infrared system according to the verification results. The reliability of the fusion algorithm will be described based on phantom and patient studies. The results indicated that the 6D fusion method is better compared to the 3D method if there are rotational deviations between the simulation and setup positions. Recently, the system has been augmented with the capabilities for image-guided positioning of targets in motion due to respiration and for gated treatment of those targets. The infrared markers provide a respiratory signal for tracking and gating of the treatment beam, with the x-ray system providing periodic confirmation of patient position relative to the gating window throughout the duration of the gated delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monitor Unit Checking in Heterogeneous Stereotactic Body Radiotherapy Treatment Planning

Treatment of lung cancer using very-high-dose fractionation in small fields requires well-tested dose modeling, a method for density-averaging compound targets constructed from different parts of the breathing cycle, and monitor unit verification of the heterogeneity-corrected treatment plans. The quality and safety of each procedure are dependent on these factors. We have evaluated the dosimetry of our first 26 stereotactic body radiotherapy (SBRT) patients, including 260 treatment fields, planned with the Pinnacle treatment planning system. All targets were combined from full expiration and inspiration computed tomography scans and planned on the normal respiration scan with 6-MV photons. Combined GTVs (cGTVs) have been density-averaged in different ways for comparison of the effect on total monitor units. In addition, we have compared planned monitor units against hand calculations using 2 classic 1D correction methods: (1) effective attenuation and (2) ratio of Tissue-Maximum Ratios (TMRs) to determine the range of efficacy of simple verification methods over difficult-to-perform measurements. Different methods of density averaging for combined targets have been found to have minimal impact on total dose as evidenced by the range of total monitor units generated for each method. Nondensity-corrected treatment plans for the same fields were found to require about 8% more monitor units on average. Hand calculations, using the effective attenuation method were found to agree with Pinnacle calculations for nonproblematic fields to within {+-}10% for >95% of the fields tested. The ratio of TMRs method was found to be unacceptable. Reasonable choices for density-averaging of cGTVs using full inspiration/expiration scans should not strongly affect the planning dose. Verification of planned monitor units, as a check for problematic fields, can be done for 6-MV fields with simple 1D effective attenuation-corrected hand calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p < 0.05). Mean intrafractional setup errors with use of the Body Pro-Lok system were as follows: X, 0.41 ± 0.46 mm; Y, 0.86 ± 0.80 mm; Z, 0.33 ± 0.44 mm; and roll, 0.12 ± 0.19°. Mean liver-induced respiratory motion determinations were as follows: (1) abdominal compression: X, 2.33 ± 1.22 mm; Y, 5.11 ± 2.05 mm; Z, 2.13 ± 1.05 mm; and 3D vector, 6.22 ± 1.94 mm; and (2) free breathing: X, 3.48 ± 1.14 mm; Y, 9.83 ± 3.00 mm; Z, 3.38 ± 1.59 mm; and 3D vector, 11.07 ± 3.16 mm. Between-group differences were statistically different in 4 directions (p < 0.05). Conclusions: The Body Pro-Lok system is capable of improving interfractional and intrafractional setup accuracy and minimizing tumor movement owing to respirations in patients with intrahepatic HCC during hypofractionated helical tomotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing FPAR Source and Parameter Optimization Scheme in Application of a Diagnostic Carbon Flux Model

The combination of satellite remote sensing and carbon cycle models provides an opportunity for regional to global scale monitoring of terrestrial gross primary production, ecosystem respiration, and net ecosystem production. FPAR (the fraction of photosynthetically active radiation absorbed by the plant canopy) is a critical input to diagnostic models, however little is known about the relative effectiveness of FPAR products from different satellite sensors nor about the sensitivity of flux estimates to different parameterization approaches. In this study, we used multiyear observations of carbon flux at four eddy covariance flux tower sites within the conifer biome to evaluate these factors. FPAR products from the MODIS and SeaWiFS sensors, and the effects of single site vs. cross-site parameter optimization were tested with the CFLUX model. The SeaWiFs FPAR product showed greater dynamic range across sites and resulted in slightly reduced flux estimation errors relative to the MODIS product when using cross-site optimization. With site-specific parameter optimization, the flux model was effective in capturing seasonal and interannual variation in the carbon fluxes at these sites. The cross-site prediction errors were lower when using parameters from a cross-site optimization compared to parameter sets from optimization at single sites. These results support the practice of multisite optimization within a biome for parameterization of diagnostic carbon flux models.

54 ENVIRONMENTAL SCIENCES↗

Recent (<4 year old) Leaf Litter is Not a Major Source of Microbial Carbon in a Temperate Forest Mineral Soil

Microbial communities in soil A horizons derive their carbon from several potential sources: organic carbon (C) transported down from overlying litter and organic horizons, root-derived C, or soil organic matter. We took advantage of a multi-year experiment that manipulated the {sup 14}C isotope signature of surface leaf litter inputs in a temperate forest at the Oak Ridge Reservation, Tennessee, USA, to quantify the contribution of recent leaf litter C to microbial respiration and biomarkers in the underlying mineral soil. We observed no measurable difference (< {approx}40{per_thousand} given our current analytical methods) in the radiocarbon signatures of microbial phospholipid fatty acids (PLFA) isolated from the top 10 cm of mineral soil in plots that experienced 3 years of litterfall that differed in each year by {approx}750{per_thousand} between high-{sup 14}C and low-{sup 14}C treatments. Assuming any difference in {sup 14}C between the high- and low-{sup 14}C plots would reflect C derived from these manipulated litter additions, we estimate that <6% of the microbial C after 4 years was derived from the added 1-4-year-old surface litter. Large contributions of C from litter < 1 year (or >4 years) old (which fell after (or prior to) the manipulation and therefore did not differ between plots) are not supported because the {sup 14}C signatures of the PLFA compounds (averaging 200-220{per_thousand}) is much higher that of the 2004-5 leaf litter (115{per_thousand}) or pre-2000 litter. A mesocosm experiment further demonstrated that C leached from {sup 14}C-enriched surface litter or the O horizon was not a detectable C source in underlying mineral soil microbes during the first eight months after litter addition. Instead a decline in the {sup 14}C of PLFA over the mesocosm experiment likely reflected the loss of a pre-existing substrate not associated with added leaf litter. Measured PLFA {Delta}{sup 14}C signatures were higher than those measured in bulk mineral soil organic matter in our experiments, but fell within the range of {sup 14}C values measured in mineral soil roots. Together, our experiments suggest that root-derived C is the major (>60%) source of C for microbes in these temperate deciduous forest soils.

54 ENVIRONMENTAL SCIENCES↗

Soil moisture drives microbial controls on carbon decomposition in two subtropical forests

Knowledge of microbial mechanisms is critical to understand Earth's biogeochemical cycle under climate and environmental changes. However, large uncertainties remain in model simulations and predictions due to the lack of explicit parameterization of microbial data and few applications beyond the laboratory. In addition, most experimental and modeling studies of warming-induced changes in soil carbon (C) focus on temperature sensitivity, neglecting concomitant effects of changes in soil moisture. Soil microbes are sensitive to moisture, and their responses can dramatically impact soil biogeochemical cycles. Here we represent microbial and enzymatic functions in response to changes in moisture in the Microbial-ENzyme Decomposition (MEND) model. Through modeling with long-term field observations from subtropical forests, we demonstrate that parameterization with microbial data in addition to respiration fluxes greatly increases confidence in model simulations. We further employ the calibrated model to simulate the responses of soil organic C (SOC) under multiple environmental change scenarios. The model shows significant increases in SOC in response to decreasing soil moisture and only minor changes in SOC in response to increasing soil temperature. Increasing litter inputs also cause a significant increase in SOC in the pine forest, whereas an insignificant negative effect is simulated in the broadleaf forest. We also demonstrate the co-metabolism mechanism for the priming effects, i.e., more labile inputs to soil could stimulate microbial and enzymatic growth and activity. Furthermore our study provides strong evidence of microbial control over soil C decomposition and suggests the future trajectory of soil C may be more responsive to changes in soil moisture than temperature, particularly in tropical and subtropical environments.

54 ENVIRONMENTAL SCIENCES↗

Revising the dynamic energy budget theory with a new reserve mobilization rule and three example applications to bacterial growth

Dynamic energy budget (DEB) theory has been applied to model a wide range of organisms, including microbes. In the standard DEB model, biomass is partitioned into reserve and structural compartments, where reserve biomass is mobilized in a pseudolinear manner (while the reserve biomass density, defined as the ratio between reserve and structural biomass, decays linearly) to drive maintenance and the growth of structural biomass (and extracellular enzyme production if it is considered). However, the linear dynamics of the reserve biomass density makes the standard DEB model incapable of explaining the slowdown of microbial growth at high reserve density that is caused by macromolecular crowding effect which reduces biochemical reaction rates (a typical situation occurs when microbes are experiencing severe moisture stress) and is inconsistent with the observation that intracellular enzymatic reactions generally follow non-linear kinetics. By partitioning biomass into reserve, kinetic, and structural compartments, we show here that the Equilibrium Chemistry Approximation (ECA) kinetics can be used to represent enzymatically catalyzed reserve biomass mobilization that can then drive the kinetic and structural biomass synthesis. This revised DEB model better represents the tradeoff in ribosome allocation for structural growth and internal enzyme production, is structurally compatible with metabolic models of cell individuals, and includes the standard DEB model and the popular compromise model as special cases for representing population growth. We then applied the revised DEB model to interpret components of bacterial respiration, their dependence on substrate availability, and emergent microbial carbon use efficiency dynamics for an exponentially growing population. We found that the revised DEB model enables a better understanding of bacterial substrates use (carbon in our examples) than that can be derived from a few other models in the literature. In particular, the revised DEB model explains why carbon use efficiency may first increase, then plateau, and finally decrease with growth rate (and substrate uptake rate), as a function of proteomics. Additionally, the revised DEB model explains why the kinetic biomass compartment needs to be divided to reasonably incorporate proteomic control of microbial growth.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Analysis of Ligand Stimulation of the Histidine Kinase NarX

Histidine kinase receptors are a large family of membrane-spanning proteins found in many prokaryotes and some eukaryotes. They are a part of two-component signal transduction systems, which each comprise a sensor kinase and a response regulator and are involved with the regulation of many cellular processes. NarX is a histidine kinase receptor that responds to nitrate and nitrite to effect regulation of anaerobic respiration in various bacteria. We present high-resolution X-ray crystal structures of the periplasmic sensor domain from Escherichia coli NarX in a complex with nitrate and in the apo state. Our analysis reveals that nitrate-binding induces conformation changes that result in a piston-type displacement between the N- and C-terminal helices of the periplasmic domain. Such conformational changes might represent a conserved mechanism of signaling in histidine kinases by which ligand binding is communicated across the lipid bilayer.

36 MATERIALS SCIENCE↗

Structural Analysis of Sensor Domains from the TMAO-Responsive Histidine Kinase Receptor TorS.

Histidine kinase receptors respond to diverse signals and mediate signal transduction across the plasma membrane in all prokaryotes and certain eukaryotes. Each receptor is part of a two-component system that regulates a particular cellular process. Organisms that use trimethylamine-N-oxide (TMAO) as a terminal electron acceptor typically control their anaerobic respiration through the TMAO reductase (Tor) pathway, which the TorS histidine kinase activates when sensing TMAO in the environment. We have determined crystal structures for the periplasmic sensor domains of TorS receptors from Escherichia coli and Vibrio parahaemolyticus. TorS sensor domains have a novel fold consisting of a membrane-proximal right-handed four-helical bundle and a membrane-distal left-handed four-helical bundle, but conformational dispositions differ significantly in the two structures. Isolated TorS sensor domains dimerize in solution; and from comparisons with dimeric NarX and Tar sensors, we postulate that signaling through TorS dimers involves a piston-type displacement between helices.

36 MATERIALS SCIENCE↗

An Asymmetry-to-Symmetry Switch in Signal Transmission by the Histidine Kinase Receptor for TMAO

The osmoregulator trimethylamine-N-oxide (TMAO), commonplace in aquatic organisms, is used as the terminal electron acceptor for respiration in many bacterial species. The TMAO reductase (Tor) pathway for respiratory catalysis is controlled by a receptor system that comprises the TMAO-binding protein TorT, the sensor histidine kinase TorS, and the response regulator TorR. Here we study the TorS/TorT sensor system to gain mechanistic insight into signaling by histidine kinase receptors. We determined crystal structures for complexes of TorS sensor domains with apo TorT and with TorT (TMAO); we characterized TorS sensor associations with TorT in solution; we analyzed the thermodynamics of TMAO binding to TorT-TorS complexes; and we analyzed in vivo responses to TMAO through the TorT/TorS/TorR system to test structure-inspired hypotheses. TorS-TorT(apo) is an asymmetric 2:2 complex that binds TMAO with negative cooperativity to form a symmetric active kinase.

59 BASIC BIOLOGICAL SCIENCES↗

The Crystal Structure of the Extracellular 11-heme Cytochrome UndA Reveals a Conserved 10-heme Motif and Defined Binding Site for Soluble Iron Chelates.

Members of the genus Shewanella translocate deca- or undeca-heme cytochromes to the external cell surface thus enabling respiration using extracellular minerals and polynuclear Fe(III) chelates. The high resolution structure of the first undeca-heme outer membrane cytochrome, UndA, reveals a crossed heme chain with four potential electron ingress/egress sites arranged within four domains. Sequence and structural alignment of UndA and the deca-heme MtrF reveals the extra heme of UndA is inserted between MtrF hemes 6 and 7. The remaining UndA hemes can be superposed over the heme chain of the decaheme MtrF, suggesting that a ten heme core is conserved between outer membrane cytochromes. The UndA structure is the first outer membrane cytochrome to be crystallographically resolved in complex with substrates, an Fe(III)-nitrilotriacetate dimer or an Fe(III)-citrate trimer. The structural resolution of these UndA-Fe(III)-chelate complexes provides a rationale for previous kinetic measurements on UndA and other outer membrane cytochromes.

59 BASIC BIOLOGICAL SCIENCES↗

Adenosine 3',5'-cyclic monophosphate (cAMP)-dependent phosphoregulation of mitochondrial complex I is inhibited by nucleoside reverse transcriptase inhibitors

Nucleoside analog reverse transcriptase inhibitors (NRTIs) are known to directly inhibit mitochondrial complex I activity as well as various mitochondrial kinases. Recent observations that complex I activity and superoxide production are modulated through cAMP-dependent phosphorylation suggests a mechanism through which NRTIs may affect mitochondrial respiration via kinase-dependent protein phosphorylation. In the current study, we examine the potential for NRTIs to inhibit the cAMP-dependent phosphorylation of complex I and the associated NADH:CoQ oxidoreductase activities and rates of superoxide production using HepG2 cells. Phosphoprotein staining of immunocaptured complex I revealed that 3'-azido-3'-deoxythymidine (AZT; 10 and 50 {mu}M), AZT monophosphate (150 {mu}M), and 2',3'-dideoxycytidine (ddC; 1 {mu}M) prevented the phosphorylation of the NDUFB11 subunit of complex I. This was associated with a decrease in complex I activity with AZT and AZT monophosphate only. In the presence of succinate, superoxide production was increased with 2',3'-dideoxyinosine (ddI; 10 {mu}M) and ddC (1 {mu}M). In the presence of succinate + cAMP, AZT showed an inverse dose-dependent effect on superoxide production. None of the NRTIs examined inhibit PKA activity suggesting that the observed effects are due to a direct interaction with complex I. These data demonstrate a direct effect of NRTIs on cAMP-dependent regulation of mitochondrial bioenergetics independent of DNA polymerase-{gamma} activity; in the case of AZT, these observations may provide a mechanism for the observed long-term toxicity with this drug.

60 APPLIED LIFE SCIENCES↗