Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Crystalline, liquid crystalline, and isotropic phases of sodium deoxycholate in water

Sodium deoxycholate (NaDC) is an important example of bile salts, representing systems with complex phase behavior involving both crystalline and mesophase structures. In this study, properties of NaDC-water mixtures were evaluated as a function of composition and temperature via X-ray diffraction with synchrotron (sXRD) and laboratory radiation sources, water sorption, polarized light, hot-stage microscopy, and freezing-point osmometry. Several phases were detected depending on the composition and temperature, including isotropic solution phase, liquid crystalline (LC) phase, crystalline hydrate, and ice. The LC phase was identified as hexagonal structure by sXRD, with up to 14 high-order reflections detected. The crystalline phase was found to be nonstoichiometric hydrate, based on XRD and water sorption data. The phase diagram of NaDC-water system has been refined based on both results of this study and other reports in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SHORT GAMMA-RAY BURSTS: THE MASS OF THE ACCRETION DISK AND THE INITIAL RADIUS OF THE OUTFLOW

In this work, we estimate the accretion-disk mass in the specific scenario of binary-neutron-star merger with current observational data. Assuming that the outflows of short gamma-ray bursts (GRBs) are driven via neutrino-antineutrino annihilation we estimate the disk mass of about half of short bursts in the sample to be {approx}0.01-0.1 M{sub sun}, in agreement with that obtained in the numerical simulations. Massive disks ({approx}several 0.1 M{sub sun}) found in some other short GRBs may point to the more efficient magnetic process of extracting energy or the neutron star and black hole binary progenitor. Our results suggest that some short bursts may be really due to the coalescence of double neutron stars and are promising gravitational wave radiation sources. For future short GRBs with simultaneous gravitational-wave detections, the disk mass may be reliably inferred and the validity of our approach will be tested. We also propose a method to constrain the initial radius of a baryonic outflow where it is launched (R{sub 0}) without the need of identifying an ideal thermal spectrum component. We then apply it to GRB 090510 and get R{sub 0} {approx}< 6.5 x 10{sup 6}({Gamma}{sub ph}/2000){sup -4} cm, suggesting that the central engine is a black hole with a mass <22 M{sub sun}({Gamma}{sub ph}/2000){sup -4}, where {Gamma}{sub ph} is the bulk Lorentz factor of the outflow at the photospheric radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes, and experimental area and infrastructure.

43 PARTICLE ACCELERATORS↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Unattended Sensor System With CLYC Detectors

We have developed a next-generation unattended sensor for detecting anomalous radiation sources. The system combines several technologies to reduce size and weight, increase battery lifetime, and improve decision-making capabilities. Sixteen Cs2LiYCl6:Ce (CLYC) scintillators allow for gamma-ray spectroscopy and neutron detection in the same volume. Low-power electronics for readout, high voltage bias, and digital processing reduce the total operating power to 1.3 W. Computationally efficient analysis algorithms perform spectral anomaly detection and isotope identification. When an alarm occurs, the system transmits alarm information over a cellular modem. In this paper, we describe the overall design of the unattended sensor, present characterization results, and compare the performance to stock NaI:Tl and 3He detectors.

CLYC↗

Studies of beam injection with a compensated bump and uncompensated bump in a synchrotron

Synchrotron radiation sources Indus-1 and Indus-2 have a synchrotron as the common injector. A three kicker compensated bump injection scheme was employed for beam injection into this synchrotron. The stored beam current in the synchrotron is higher, when all the three kickers are operated at the same current than when kickers are operated at currents required to generate compensated bump. Beam dynamics studies have been done to understand why this happens. Theoretical studies indicate that higher stored current in the later case is attributed to smaller residual oscillations of injected beam. These studies also reveal that if the angle of the injected beam during beam injection is kept varying, the performance could be further improved. This is experimentally confirmed by injecting the beam on rising part of the injection septum magnet current pulse.

43 PARTICLE ACCELERATORS↗

Particle-in-cell simulations of multi-MeV pulsed X-ray induced air plasmas at low pressures

A full kinetic modelling of the charge particles dynamics generated upon the irradiation of an air-filled cavity by a multi-MeV pulsed x-ray is performed. From the calculated radiative source generated by the ASTERIX generator, we calculated the electromagnetic fields generated by x-ray induced air plasmas in a metallic cavity at different pressures. Simulations are carried out based on a Particle-In-Cell interpolation method which uses 3D Maxwell-Vlasov calculations of the constitutive charged species densities of air plasmas at different pressures at equilibrium. The resulting electromagnetic fields within the cavity are calculated for different electron densities up to 4 × 10{sup 10 }cm{sup −3}. For each air pressure, we show electronic plasma waves formation followed by Landau damping. As electron density increases, the calculations exhibit space-charged neutralization and return current formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Age on the Relative Biological Effectiveness of Carbon Ion Radiation for Induction of Rat Mammary Carcinoma

Purpose: The risk of developing secondary cancer after radiotherapy, especially after treatment of childhood cancers, remains a matter of concern. The high biological effects of carbon-ion radiation have enabled powerful radiotherapy, yet the approach is commonly restricted to the treatment of adults. Susceptibility of the fetus to particle radiation–induced cancer is also unclear. The present study is aimed to investigate the effect of carbon-ion irradiation in childhood on breast carcinogenesis. Methods and Materials: We irradiated female Sprague-Dawley rats of various ages (embryonic days 3, 13, and 17 and 1, 3, 7, and 15 weeks after birth) with {sup 137}Cs γ rays or a 290-MeV/u monoenergetic carbonion beam (linear energy transfer, 13 keV/μm). All animals were screened weekly for mammary carcinoma by palpation until they were 90 weeks old. Results: Irradiation of fetal and mature (15-week-old) rats with either radiation source at a dose of 0.2 or 1 Gy did not substantially increase the hazard ratio compared with the nonirradiated group. Dose responses (0.2-2.0 Gy) to γ rays were similar among the groups of rats irradiated 1, 3, and 7 weeks after birth. The effect of carbon ions increased along with the age at the time of irradiation, indicating relative biological effectiveness values of 0.2 (−0.3, 0.7), 1.3 (1.0, 1.6), and 2.8 (1.8, 3.9) (mean and 95% confidence interval) for animals that were 1, 3, and 7 weeks of age, respectively. Conclusions: Our findings imply that carbonion therapy may be associated with a risk of secondary breast cancer in humans, the extent of which may depend on the age of the patient at the time of irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose estimates and their uncertainties for use in epidemiological studies of radiation-exposed populations in the Russian Southern Urals

Many residents of the Russian Southern Urals were exposed to radioactive environmental pollution created by the operations of the Mayak Production Association in the mid- 20 th century. There were two major releases: the discharge of about 1x10 17 Bq of liquid waste into the Techa River between 1949 and 1959; and the atmospheric release of 7.4 * 10 16 Bq as a result an explosion in the radioactive waste-storage facility in 1957. The releases into the Techa River resulted in the exposure of more than 30,000 people who lived in riverside villages between 1950 and 1961. The 1957 accident contaminated a larger area with the highest exposure levels in an area that is called the East Urals Radioactive Trace (EURT). Current epidemiologic studies of the exposed populations are based on dose estimates obtained using a Monte-Carlo dosimetry system (TRDS-2016MC) that provides multiple realizations of the annual doses for each cohort member. These dose realizations provide a central estimate of the individual dose and information on the uncertainty of these dose estimates. In addition, the correlation of individual annual doses over realizations provides important information on shared uncertainties that can be used to assess the impact of shared dose uncertainties on risk estimate uncertainty.This paper considers dose uncertainties in the TRDS-2016MC. Individual doses from external and internal radiation sources were reconstructed for 48,036 people based on environmental contamination patterns, residential histories, individual 90 Sr body-burden measurements and dietary intakes. Dietary intake of 90 Sr resulted in doses accumulated in active bone marrow (or simply, marrow) that were an order of magnitude greater than those in soft tissues. About 84% of the marrow dose and 50% of the stomach dose was associated with internal exposures. The lognormal distribution is well-fitted to the individual dose realizations, which, therefore, could be expressed and easily operated in terms of geometric mean (GM) and geometric standard deviation (GSD). Cohort average GM for marrow and stomach cumulative doses are 0.21 and 0.03 Gy, respectively. Cohort average dose uncertainties in terms of GSD are as follows: for marrow it is 2.93 (90%CI: 2.02–4.34); for stomach and the other non-calcified tissues it is 2.32 (90% CI: 1.78–2.9).

61 RADIATION PROTECTION AND DOSIMETRY↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Radiation Proofing Polyethylene: Use of Oxygen Scavenging Additives

The degradation of polyethylene (PE) from radiation sources with both thermal and nuclear interactions show sensitivities towards oxygen and air. Characterization of the sensitivities in both inert and oxygenated atmospheres can be characterized by thermogravimetric analysis (TGA). Under argon, the thermal degradation of PE follows a random scission pathway that has activation energy of ~229 kJ mol -1 . The activation energy of PE is reduced by ~30% when 1% air is added to the inert argon atmosphere, illustrating the impact of oxygen on the degradation of PE. This effort seeks to diminish degradation of PE waste containment bags and extend their lifetime, thereby, reducing the cost and worker exposure risk. The project evaluated the use of oxygen scavenger nanoparticles to mitigate the deteriorating effects of oxygen on polymer physical properties and reduce polymer degradation. The thermal degradation of PE composites with various additives were tested and two additives showed promising results approaching the activation energy of pristine PE in an inert atmosphere. This activity was sponsored by the EM Office of Technology Development through SRNL’s Technical Task Plan SR091701.

36 MATERIALS SCIENCE↗

Potential improvements in brain dose estimates for internal emitters

Background: Element-specific biokinetic models are used to reconstruct doses to systemic tissues from internal emitters. Typically, a systemic model for a radionuclide explicitly depicts only its dominant repositories. Remaining tissues and fluids are aggregated into a pool called Other tissue in which the radionuclide is assumed to be uniformly distributed. In the systemic biokinetic models used in radiation protection, the brain usually is addressed as an implicit mass fraction of Other tissue rather than an explicitly depicted repository. Additionally, due to increasing interest in radiation effects on the brain, efforts are underway to improve brain dosimetry for internal radiation sources. Methods: We assessed potential improvements in brain dosimetry for internal emitters by explicitly modelling brain kinetics rather than treating the brain as a mass fraction of Other tissue. We selected ten elements for which brain kinetics can be modeled using published biokinetic data. Injection dose coefficients were calculated for a relatively long-lived radioisotope of each element using each of two versions of the ICRP’s latest systemic biokinetic model for each element, the original version and a modified version differing only in the treatment of brain. If the ICRP model contained an explicit brain pool, the modified version depicted brain instead as a mass fraction of Other tissue. If the ICRP model included brain in Other tissue, the modified version included an explicit brain pool with kinetics based on best available brain-specific data.Results: The result for a given radionuclide is expressed as a ratio A:B, where A and B are the dose coefficients based on the versions of the model with and without an explicit brain pool, respectively. The following ratios A:B were obtained for the 10 radionuclides addressed here: 241 Am, 0.13; 207 Bi, 0.57; 234 U, 0.81; 239 Pu, 0.96; 203 Hg (vapor), 1.4; 134 Cs, 1.5; 54 Mn, 1.7; 210 Po, 1.7; 226 Ra, 1.9; 210 Pb, 3.3. These ratios indicate that a dose estimate for brain based on a biokinetic model with brain implicitly contained in Other tissue may substantially underestimate or substantially overestimate a dose estimate that reflects best available brain-specific biokinetic data. Of course, the reliability of the latter estimate depends on the quality of the underlying biokinetic data.Conclusions: Finally, where feasible, the brain should be depicted explicitly in biokinetic models used in epidemiological studies addressing adverse effects of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Curium(iii) radiation-induced reaction kinetics in aqueous media

Insight into the effects of radiolytic processes on the actinides is critical for advancing our understanding of their solution chemistry because the behaviour of these elements cannot be easily separated from the influence of their inherent radiation field. However, minimal information exists on the radiation-induced redox behaviour of curium (Cm), a key trivalent transuranic element present in used nuclear fuel and frequently used as an alpha radiation source. Here we present a kinetic study on the aqueous redox reactions of Cm(III) with radicals generated through the radiolysis of aqueous media. In particular, we probe reaction kinetics in nitric acid solutions that are used as the aqueous phase component of used nuclear fuel reprocessing solvent systems. Second-order rate coefficients (k) were measured for the reaction of Cm(III) with the hydrated electron (e aq - , k = (1.25 ± 0.03) × 10 10 M -1 s -1 ), hydrogen atom (H˙, k = (5.16 ± 0.37) × 10 8 M -1 s -1 ), hydroxyl radical (˙OH, k = (1.69 ± 0.24) × 10 9 M -1 s -1 ), and nitrate radical (NO 3 ˙, k = (4.83 ± 0.09) × 10 7 M -1 s -1 ). Furthermore, the first-ever Cm(II) absorption spectrum (300–700 nm) is also reported. These kinetic data dispel the status quo notion of Cm(III) possessing little to no redox chemistry in aqueous solution, and suggest that the resulting Cm(II) and Cm(IV) transients could exist in irradiated aqueous solutions and be available to undergo subsequent redox chemistry with other solutes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of CLYC Detectors for a Next-Generation Unattended Sensor

We are developing a next-generation unattended sensor for detecting anomalous radiation sources. The system uses a scintillator material with dual sensitivity to gamma rays and neutrons, Cs 2 LiYCl 6 :Ce (CLYC), to reduce the size and complexity of the design. CLYC also offers a best-case energy resolution under 4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The unattended sensor features sixteen one-inch CLYC detectors, each read out by a photomultiplier tube and custom readout electronics. A field-programmable gate array implements a suite of efficient processing algorithms for anomaly detection and isotope identification, and transmits alarm information to a base station via a wireless link. The system is designed to operate on battery power for several weeks. In this paper, we report the energy resolution, linearity, detection efficiency, and temperature stability of the first CLYC detectors acquired for the project. Rather than characterizing the scintillator material under ideal conditions, we evaluate the detectors with the components selected for the unattended sensor, acknowledging the tradeoffs imposed by small size, limited power budget, and uncontrolled environmental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

An Optically Stimulated Luminescence Uranium Enrichment Monitor

The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both the low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10{sup 16}-10{sup 18} W/cm{sup 2} with CO{sub 2} clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t {approx} 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of {approx}100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposed Muon Radiography Method for Spent Fuel Cask Interrogation

Multiple scattering muon radiography is a technique that was developed at Los Alamos National Laboratory (LANL) to detect high Z material using cosmic ray muons as a radiation source. As a result,there has been considerable interest in using the technique to radiograph nuclear waste inside of storage casks. Recently,the technique has been used to interrogate the inside of a MC-10 dry fuel cask at Idaho National Laboratory (INL).This is the only technique that has been successful in imaging the interior of a spent fuel cask.The measurement was performed with the LANL Mini Muon Tracker (MMT), composed of two super-modules of drift tubes and readout electronics placed on each side of the fuel cask. The final result was a one dimensional histogram (projection) that showed areal scattering density within the cask binned according to horizontal position within the cask. While successful, the MMT is not designed for an optimal measurement of a fuel cask. The MMT only covers a limited solid angle around the cask and needs to be orientated so as to be aligned with the grid of stored fuel bundles. Even when properly aligned, the resulting areal scattering density projection indicates that a fuel bundle within a column is missing, but is ambiguous as to which row is lacking the fuel bundle. This paper discusses a potential new detector and analytical technique that may be used to better radiograph the nuclear material inside of a storage cask. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗