Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The radiation hydrodynamics of relativistic shear flows

We present a method for analyzing the interaction between radiation and matter in regions of intense, relativistic shear that can arise in many astrophysical situations. We show that there is a simple velocity profile that should be manifested in regions of large shear that have “lost memory” of their boundary conditions, and we use this self-similar velocity profile to construct the surface of last scattering, or the τ≃1 surface, as viewed from any comoving point within the flow. We demonstrate that a simple treatment of scattering from this τ≃1 surface exactly conserves photon number, and we derive the rate at which the radiation field is heated due to the shear present in the flow. The components of the comoving radiation energy–momentum tensor are calculated, and we show that they have relatively simple, approximate forms that interpolate between the viscous (small shear) and streaming (large shear) limits. We put our expression for the energy–momentum tensor in a covariant form that does not depend on the explicit velocity profile within the fluid and, therefore, represents a natural means for analyzing general, radiation-dominated, relativistic shear flows.

79 ASTRONOMY AND ASTROPHYSICS↗

A free-electron laser in a uniform magnetic field

The study shows that a free-electron laser can operate in a uniform, longitudinal magnetic field. The fully relativistic Lorentz force equations are examined and solved order by order in a radiation field strength to obtain analytic expressions for the electron trajectory and energy as functions of initial electron position within a wavelength of light. Analytic expressions for the longitudinal and transverse bunching and for laser gain are found. The bunching of this laser process is compared to the bunching processes involved in (1) a Stanford free-electron laser and (2) a cyclotron maser. The results received can be useful in exploring light amplification in astrophysical magnetic fields, the magnetosphere, and in laboratory devices.

Ride, S. K.↗

The universe in a box - Thermal effects in the standard cold dark matter scenario

An attempt is made to compute the evolution of a representative piece of the universe at a minimal resolution of a flux-based mesh code coupled with a standard particle-mesh dark matter code. It is found that, on scales greater than 1/h Mpc, dark matter is more clumped than gas. Bremsstrahlung and Compton cooling are unimportant on scales of 1 Mpc or greater. Shocks gradually heat the gas, leaving most of it in voids at T = 10 exp 3.5 K or less, but with a small fraction reaching T = 10 million K or more. Ultraviolet and soft X-ray emission from the heated gas is significant, providing an important part of the background radiation field and significant ionizing of the intergalactic medium. The mean induced Delta T/T for microwave background radiation in the Rayleigh-Jeans part of the spectrum is 1.1 x 10 to the -6th with fluctuation of 5.6 x 10 to the -7th on arcmin scales and a mean y parameter of 5.5 x 10 to the -7th, which is potentially detectable by the COBE satellite.

Cen, R. Y.↗

Radiation measurements in low Earth orbit: U.S. and Russian results

The radiation environment in low-Earth orbital flights is complex. It is strongly influenced by altitude, orbital inclination, time within a given solar cycle, flight duration, and shielding configuration. At any specified shielded location, both primary and secondary particles generated by nuclear interactions of primary particles with spacecraft structure are present. In addition, there are atmospheric secondary albedo protons and neutrons. No single detector can adequately measure this complex radiation field, and measurements of very high linear energy transfer target fragmentation products are particularly difficult. Crew radiation exposure have exclusively been measured using passive thermoluminescent detectors (TLDs). The cosmonaut exposures on the Mir station, uncorrected for the TLD inefficiency and neutron contribution, have varied from a low of 2.43 cGy to a high of 8.70 cGy. These correspond to dose rates of 144 microGy d(-1) to 468 microGy d(-1). These are consistent with rates observed by the D2 ion-chamber. Using the rates measured by the D1 chamber, dose rates under 4 cm of water vary from about 60 microGy d-1 to about 350 microGy d(-1). There is variation of about a factor of two between the dose rates at various locations in the same module. There is also a variation of dose rates of about a factor two between various modules. The highest astronaut dose for a Shuttle flight (STS-82) was 3.205 cGy with a dose rate of 3,221 microGy d(-1). Neutron contribution could be 36 +/- 15% of the astronaut charged particle dose equivalent. East-West asymmetry of dose rate is significant for spacecrafts that fly in an fixed altitude, such as the International Space Station.

NASA Center JSC↗

An Assessment of Remote Visual Methods to Detect Cracking in Reactor Components

Recently, the U.S. nuclear industry has proposed replacing current volumetric and/or surface examinations of certain components in commercial nuclear power plants, as required by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI, “Inservice Inspection of Nuclear Power Plant Components,” with a simpler visual testing (VT) method. The advantages of VT are that these tests generally involve much less radiation exposure and time to perform the examination than do volumetric examinations such as ultrasonic testing. The issues relative to the reliability of VT in determining the structural integrity of reactor components were examined. Some piping and pressure vessel components in a nuclear power station are examined using VT as they are either in high radiation fields or component geometry precludes the use of ultrasonic testing (UT) methodology. Remote VT with radiation-hardened video systems has been used by nuclear utilities to find cracks in pressure vessel cladding in pressurized water reactors, core shrouds in boiling water reactors, and to investigate leaks in piping and reactor components. These visual tests are performed using a wide variety of procedures and equipment. The techniques for remote VT use submersible closed-circuit video cameras to examine reactor components and welds. PNNL conducted a parametric study that examined the important variables influencing the effectiveness of a remote visual test. Tested variables included lighting techniques, camera resolution, camera movement, and magnification. PNNL also conducted a limited laboratory test using a commercial visual testing camera system to experimentally determine the ability of the camera system to detect cracks of various widths under ideal conditions. The results of these studies and their implications are presented in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

Goals: 1) Qualify the CAAS-3S system to a mixed-field radiation dose and dose rate, and 2) Extend the Y-12 Shielding MCNP Validation to rad-si. This paper represents the efforts of Y-12 and UPF personnel, and their interpretation of the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors

Purpose: As the practice of using high-energy photon beams to create therapeutic radiation fields of subcentimeter dimensions (as in intensity-modulated radiotherapy or stereotactic radiosurgery) grows, so too does the need for accurate verification of beam output at these small fields in which standard practices of dose verification break down. This study investigates small-field output factors measured using a small plastic scintillation detector (PSD), as well as a 0.01 cm{sup 3} ionization chamber. Specifically, output factors were measured with both detectors using small fields that were defined by either the X-Y collimator jaws or the multileaf collimator (MLC). Methods: A PSD of 0.5 mm diameter and 2 mm length was irradiated with 6 and 18 MV linac beams. The PSD was positioned vertically at a source-to-axis distance of 100 cm, at 10 cm depth in a water phantom, and irradiated with fields ranging in size from 0.5x0.5 to 10x10 cm{sup 2}. The field sizes were defined either by the collimator jaws alone or by a MLC alone. The MLC fields were constructed in two ways: with the closed leaves (i.e., those leaves that were not opened to define the square field) meeting at either the field center line or at a 4 cm offset from the center line. Scintillation light was recorded using a CCD camera and an estimation of error in the median-filtered signals was made using the bootstrapping technique. Measurements were made using a CC01 ionization chamber under conditions identical to those used for the PSD. Results: Output factors measured by the PSD showed close agreement with those measured using the ionization chamber for field sizes of 2.0x2.0 cm{sup 2} and above. At smaller field sizes, the PSD obtained output factors as much as 15% higher than those found using the ionization chamber by 0.6x0.6 cm{sup 2} jaw-defined fields. Output factors measured with no offset of the closed MLC leaves were as much as 20% higher than those measured using a 4 cm leaf offset. Conclusions: The authors' results suggest that PSDs provide a useful and possibly superior alternative to existing dosimetry systems for small fields, as they are inherently less susceptible to volume-averaging and perturbation effects than larger, air-filled ionization chambers. Therefore, PSDs may provide more accurate small-field output factor determination, regardless of the collimation mechanism.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving the radiation hardness of graphene field effect transistors

Ionizing radiation poses a significant challenge to the operation and reliability of conventional silicon-based devices. In this paper, we report the effects of gamma radiation on graphene field-effect transistors (GFETs), along with a method to mitigate those effects by developing a radiation-hardened version of our back-gated GFETs. We demonstrate that activated atmospheric oxygen from the gamma ray interaction with air damages the semiconductor device, and damage to the substrate contributes additional threshold voltage instability. Our radiation-hardened devices, which have protection against these two effects, exhibit minimal performance degradation, improved stability, and significantly reduced hysteresis after prolonged gamma radiation exposure. Finally, we believe this work provides an insight into graphene's interactions with ionizing radiation that could enable future graphene-based electronic devices to be used for space, military, and other radiation-sensitive applications.

36 MATERIALS SCIENCE↗

SU-C-304-03: Experimental Investigation On the Accuracy of Plastic Scintillation Dosimeters in Small Fields

Purpose: To investigate the accuracy of the Exradin W1 (SI) and of an “in-house” plastic scintillation dosimeter (CHUQ PSD) in small radiation fields. Methods: Output factor (OF) measurements with the W1 and CHUQ PSD were performed for field sizes of 0.5 x 0.5, 1 x 1 and 2 x 2 cm{sup 2}. Both detectors were placed parallel to the central axis (CAX) in water. The spectrum discrimination calibration method was performed in each set-up to account for the Cerenkov (CRV) signal created in the fiber. The OFs were compared to the expected field factors in water derived using i) Monte Carlo (MC) simulations of an accurate accelerator model and ii) microLion (PTW) and D1V diode (SI) OFs. MC-derived correction factors were applied to both the microLion and D1V OFs. For the CHUQ PSD the calibration was repeated in water (// CAX), solid water (perpendicular to CAX) and under a shielded configuration. The signal was collected using a spectrometer (wavelength range = 185–1100 nm). Spectral analysis was performed to evaluate potential changes of the spectral distributions under the various calibration set-up configurations. Results: The W1 OFs presented an over-response for the 0.5 x 0.5 cm{sup 2} in the range of 3 – 4.1% relative to the expected field factor. The CHUQ PSD presented an under-response in the range of 1.5 – 2.7%, without accounting for volume averaging. The CRV spectra under the various calibration procedures appeared similar to each other and only minor changes were observed to the respective OFs. Conclusion: The W1 and CHUQ PSD can be used in small fields down to a 1 x 1 cm{sup 2} field size. Discrepancies were encountered between the two detectors for the smallest field size of 0.5 x 0.5 cm{sup 2} with the CHUQ PSD exhibiting a closer agreement to the expected field factor. Funding sources: 1) Alexander S. Onassis Public Benefit Foundation in Greece and 2) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council, Grant number: 432290, RGPIN-2014-06475.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIFFUSE HARD X-RAY EMISSION IN STARBURST GALAXIES AS SYNCHROTRON FROM VERY HIGH ENERGY ELECTRONS

The origin of the diffuse hard X-ray (2-10 keV) emission from starburst galaxies is a long-standing problem. We suggest that synchrotron emission of 10-100 TeV electrons and positrons (e {sup {+-}}) can contribute to this emission, because starbursts have strong magnetic fields. We consider three sources of e {sup {+-}} at these energies: (1) primary electrons directly accelerated by supernova remnants, (2) pionic secondary e {sup {+-}} created by inelastic collisions between cosmic ray (CR) protons and gas nuclei in the dense interstellar medium of starbursts, and (3) pair e {sup {+-}} produced between the interactions between 10 and 100 TeV {gamma}-rays and the intense far-infrared (FIR) radiation fields of starbursts. We create one-zone steady-state models of the CR population in the Galactic center (R {<=} 112 pc), NGC 253, M82, and Arp 220's nuclei, assuming a power-law injection spectrum for electrons and protons. We consider different injection spectral slopes, magnetic field strengths, CR acceleration efficiencies, and diffusive escape times, and include advective escape, radiative cooling processes, and secondary and pair e {sup {+-}}. We compare these models to extant radio and GeV and TeV {gamma}-ray data for these starbursts, and calculate the diffuse synchrotron X-ray and inverse Compton (IC) luminosities of these starbursts in the models which satisfy multiwavelength constraints. If the primary electron spectrum extends to {approx}PeV energies and has a proton/electron injection ratio similar to the Galactic value, we find that synchrotron emission contributes 2%-20% of their unresolved, diffuse hard X-ray emission. However, there is great uncertainty in this conclusion because of the limited information on the CR electron spectrum at these high energies. IC emission is likewise a minority of the unresolved X-ray emission in these starbursts, from 0.1% in the Galactic center to 10% in Arp 220's nuclei, with the main uncertainty being the starbursts' magnetic field. We also model generic starbursts, including submillimeter galaxies, in the context of the FIR-X-ray relation, finding that anywhere between 0% and 16% of the total hard X-ray emission is synchrotron for different parameters, and up to 2% in the densest starbursts assuming an E {sup -2.2} injection spectrum and a diffusive escape time of 10 Myr (E/3 GeV){sup -1/2} (h/100 pc). Neutrino observations by IceCube and TeV {gamma}-ray data from HESS, VERITAS, and CTA can further constrain the synchrotron X-ray emission of starbursts. Our models do not constrain the possibility of hard, second components of primary e {sup {+-}} from sources like pulsars in starbursts, which could enhance the synchrotron X-ray emission further.

79 ASTRONOMY AND ASTROPHYSICS↗

Physical subspace in a model of the quantized electromagnetic field coupled to an external field with an indefinite metric

We study a model of the quantized electromagnetic field interacting with an external static source {rho} in the Feynman (Lorentz) gauge and construct the quantized radiation field A{sub {mu}} ({mu}=0,1,2,3) as an operator-valued distribution acting on the Fock space F with an indefinite metric. By using the Gupta subsidiary condition {partial_derivative}{sup {mu}}A{sub {mu}}(x){sup (+)}{psi}=0, one can select the physical subspace V{sub phys}. According to the Gupta-Bleuler formalism, V{sub phys} is a non-negative subspace so that elements of V{sub phys}, called physical states, can be probabilistically interpretable. Indeed, assuming that the external source {rho} is infrared regular, i.e., {rho}/|k|{sup 3/2}(set-membership sign)L{sup 2}(R{sup 3}), we can characterize the physical subspace V{sub phys} and show that V{sub phys} is non-negative. In addition, we find that the Hamiltonian of the model is reduced to the Hamiltonian of the transverse photons with the Coulomb interaction. We, however, prove that the physical subspace is trivial, i.e., V{sub phys}=(0), if and only if the external source {rho} is infrared singular, i.e., {rho}/|k|{sup 3/2}(negated-set-membership sign)L{sup 2}(R{sup 3}). We also discuss a representation different from the above representation such that the physical subspace is not trivial under the infrared singular condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CIRCUMVENTING THE RADIATION PRESSURE BARRIER IN THE FORMATION OF MASSIVE STARS VIA DISK ACCRETION

We present radiation hydrodynamic simulations of the collapse of massive pre-stellar cores. We treat frequency-dependent radiative feedback from stellar evolution and accretion luminosity at a numerical resolution down to 1.27 AU. In the 2D approximation of axially symmetric simulations, for the first time it is possible to simulate the whole accretion phase (up to the end of the accretion disk epoch) for a forming massive star and to perform a broad scan of the parameter space. Our simulation series evidently shows the necessity to incorporate the dust sublimation front to preserve the high shielding property of massive accretion disks. While confirming the upper mass limit of spherically symmetric accretion, our disk accretion models show a persistent high anisotropy of the corresponding thermal radiation field. This yields the growth of the highest-mass stars ever formed in multi-dimensional radiation hydrodynamic simulations, far beyond the upper mass limit of spherical accretion. Non-axially symmetric effects are not necessary to sustain accretion. The radiation pressure launches a stable bipolar outflow, which grows in angle with time, as presumed from observations. For an initial mass of the pre-stellar host core of 60, 120, 240, and 480 M{sub sun} the masses of the final stars formed in our simulations add up to 28.2, 56.5, 92.6, and at least 137.2 M{sub sun}, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared and millimeter wave techniques for the Cosmic Background Explorer Satellite

The Cosmic Background Explorer Satellite will employ infrared and microwave techniques to gain information about the very early universe. Three instruments will cover the spectral range from 8 microns to 13 mm, determining both the spectrum and angular distribution of the large scale background radiation fields. A cryogenic polarizing Michelson interferometric spectrometer will measure the spectrum of the 3 deg K relic radiation from the big bang with precision. Four differential microwave radiometers will map the sky from 23 to 90 GHz in a search for anisotropy of the universe. A broadband cryogenic IR photometer will map zodiacal dust emission, galactic dust, and an extragalactic residual component.

Mather, J. C.↗

Solar and thermal radiation in the Venus atmosphere

Attention is given to the solar and thermal radiation fields of Venus. Direct measurements and the results of numerical models based on direct measurements are presented. Radiation outside the atmosphere is considered with emphasis placed on global energy budget parameters, spectral and angular dependences, spatial distribution, and temporal variations of solar and thermal radiation. Radiation fluxes inside the atmosphere below 90 km are also considered with attention given to the solar flux at the surface, solar and thermal radiation fluxes from 100 km to the surface, and radiative heating and cooling below 100 km.

Moroz, V. I.↗

Galaxies with spectral energy distributions peaking near 60 micrometers. 1: Optical spectroscopy, infrared photometry, and radio continuum data

We present and discuss broadband infrared photometry in the 1-100 micrometer wavelength range, optical spectroscopy, and radio continuum observations of a sample of IRAS galaxies with unusual spectral energy distributions that peak near 60 micrometers. For inclusion in this sample of '60 PKs', the galaxies must have satisfied the following criteria: IRAS flux ratios f(sub 60)/f(sub 100) greater than 1 and 1 less than f(sub 60)/f(sub 25) less than 4, and galactic latitude absolute value of b greater than 10 deg. In this paper, which is the first of a series, we show that the 60PKs are relatively scarce objects that represent about 2% of the spatial density of 60 micrometer-selected galaxies in the range L(60 micrometers) = 10(exp 9) to 10(exp 12) solar luminosity, but have a far-infrared luminosity function of nearly identical shape. They are detected up to redshifts of 0.2. Besides having the usual high percentage of active galaxies (approximately 30% H II-region like, 50% Seyfert 2, 10% Seyfert 1, 10% unknown) associated with a flat 25 to 60 micrometer spectral index, the sample also includes most of the galaxies that have been found to have a dust-obscured broadline region. We show that the additional f(sub 60)/f(sub 100) greater than 1 constraint selects galaxies with dust that is more centrally concentrated and exposed to a more intense radiation field than in most other IRAS galaxies. In particular, the cirrus component of the far-infrared radiation, which is typically the dominant contributor to the 100 micrometer emission from spiral galaxies, is negligible or missing. This is consistent with the fact that the most distinctive optical signature of 60PKs is the absence of spiral structure: they tend to be peculiar and/or amorphous objects.

Vader, J Patricia↗

Digitally Controlled Slot Coupled Patch Array

A four-element array conformed to a singly curved conducting surface has been demonstrated to provide 2 dB axial ratio of 14 percent, while maintaining VSWR (voltage standing wave ratio) of 2:1 and gain of 13 dBiC. The array is digitally controlled and can be scanned with the LMS Adaptive Algorithm using the power spectrum as the objective, as well as the Direction of Arrival (DoA) of the beam to set the amplitude of the power spectrum. The total height of the array above the conducting surface is 1.5 inches (3.8 cm). A uniquely configured microstrip-coupled aperture over a conducting surface produced supergain characteristics, achieving 12.5 dBiC across the 2-to-2.13- GHz and 2.2-to-2.3-GHz frequency bands. This design is optimized to retain VSWR and axial ratio across the band as well. The four elements are uniquely configured with respect to one another for performance enhancement, and the appropriate phase excitation to each element for scan can be found either by analytical beam synthesis using the genetic algorithm with the measured or simulated far field radiation pattern, or an adaptive algorithm implemented with the digitized signal. The commercially available tuners and field-programmable gate array (FPGA) boards utilized required precise phase coherent configuration control, and with custom code developed by Nokomis, Inc., were shown to be fully functional in a two-channel configuration controlled by FPGA boards. A four-channel tuner configuration and oscilloscope configuration were also demonstrated although algorithm post-processing was required.

D'Arista, Thomas↗

Upgrade of the PNNL TEPC and Multisphere Spectrometer

The Pacific Northwest National Laboratory (PNNL) has used two types of instruments, the tissue equivalent proportional counter (TEPC) and the multisphere spectrometer for characterizing neutron radiation fields in support of neutron dosimetry at the Hanford site. The US Department of Energy recently issued new requirements for radiation protection standards in 10 CFR 835 which affect the way that neutron dose equivalent rates are evaluated. In response to the new requirements, PNNL has upgraded the analyses used in conjunction with the TEPC and multisphere. The analysis software for the TEPC was modified for this effort, and a new analysis code was selected for the multisphere. These new analysis techniques were implemented and tested with measurement data that had been collected in previous measurements. In order to test the effectiveness of the changes, measurements were taken in PNNL’s Low Scatter Room using 252Cf sources in both unmoderated and D2O-moderated configurations that generate well-characterized neutron fields. The instruments were also used at Los Alamos National Laboratory (LANL), in their Neutron Free-in-Air calibration room, also using neutron sources that generate well-characterized neutron fields. The results of the software modifications and the measurements are documented in this report. The TEPC measurements performed at PNNL agreed well with accepted dose equivalent rates using the traditional analysis, agreeing with the accepted value to within 13% for both unmoderated and moderated 252Cf sources. When the new analysis was applied to the TEPC measurement data, the results were high compared to the new accepted value. A similar pattern was seen for TEPC measurements at LANL. Using the traditional analysis method, results for all neutron sources showed good agreement with accepted values, nearly always less than 10%. For the new method of analysis, however, the TEPC responded with higher dose equivalent rates than accepted, by as much as 25%. The reason for the overresponse is that there is very little attenuation of the neutrons by tissue, so it cannot match the effect of attenuation by 1 cm of tissue called for in the new standards. This could be corrected with a modified instrument with a thicker wall, or by analytical means that would need to be developed. The multisphere spectrometer performed reasonably well both at PNNL and at LANL. It could produce a neutron spectrum that was similar to the accepted spectrum, and total flux values were usually within 15% of the accepted values. Dose equivalent rates were usually within 18% of the accepted values. The average energies, however, were usually lower than the accepted values. The performance of this instrument could be much better than seen in this study. If PNNL were to add some moderating spheres to its measurement set and calculate a new set of instrument response functions, performance could be improved. The multisphere could then be a more useful instrument for assessing the dose equivalent rate in the workplace.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multidimensional attosecond photoelectron spectroscopy with shaped pulses and quantum optical fields

Correlation function expressions for multidimensional photoelectron signals obtained for the response of electrons and nuclei in molecules to multiple ultrafast optical or x-ray pulses are derived using a superoperator formalism. For classical fields and quantum matter, these signals are recast as modulus squares of transition amplitudes which depend on the pulse bandshapes. A vibrational wave-packet representation which does not involve amplitudes is derived when the nuclear dynamics is calculated classically. In the case of a quantum radiation field, the signals depend on multipoint correlation functions of field operators. Photoelectron spectroscopy with entangled photons may be studied using this formalism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗