Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

A single external cavity laser-based sensor for simultaneous detection and quantification of atmospheric methane and water vapor

A single external cavity diode laser (ECDL)-based sensor system was developed for simultaneous measurements of methane and water vapor in the atmospheric air. A home-made continuous wave (CW) ECDL with a wavelength of ∼ 1325 nm was employed to cover two absorption lines for different gas species. A high-finesse optical cavity composed of two high-reflectivity mirrors (R=0.99927) was used to enhance the gas absorption in a space of 0.5 l. An isolated methane absorption line at 7552.74 cm{sup −1} and a common (non-isolated) absorption line of water vapor and methane 7552.81cm{sup −1} were utilized for simultaneous detection. A method was developed to calculate the water vapor concentration from these lines. To our knowledge, the method and the absorption lines used in the present paper were used for the first time for simultaneous measurement of the concentrations of atmospheric methane and water vapor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase transitions in freeze-dried systems - quantification using in situ synchrotron X-ray diffractometry

The purpose is: (1) To develop a synchrotron X-ray diffraction (SXRD) method to monitor phase transitions during the entire freeze-drying cycle. Aqueous sodium phosphate buffered glycine solutions with initial glycine to buffer molar ratios of 1:3 (17:50 mM), 1:1 (50 mM) and 3:1 were utilized as model systems. (2) To investigate the effect of initial solute concentration on the crystallization of glycine and phosphate buffer salt during lyophilization. Phosphate buffered glycine solutions were placed in a custom-designed sample cell for freeze-drying. The sample cell, covered with a stainless steel dome with a beryllium window, was placed on a stage capable of controlled cooling and vacuum drying. The samples were cooled to -50 C and annealed at -20 C. They underwent primary drying at -25 C under vacuum until ice sublimation was complete and secondary drying from 0 to 25 C. At different stages of the freeze-drying cycle, the samples were periodically exposed to synchrotron X-ray radiation. An image plate detector was used to obtain time-resolved two-dimensional SXRD patterns. The ice, {beta}-glycine and DHPD phases were identified based on their unique X-ray peaks. When the solutions were cooled and annealed, ice formation was followed by crystallization of disodium hydrogen phosphate dodecahydrate (DHPD). In the primary drying stage, a significant increase in DHPD crystallization followed by incomplete dehydration to amorphous disodium hydrogen phosphate was evident. Complete dehydration of DHPD occurred during secondary drying. Glycine crystallization was inhibited throughout freeze-drying when the initial buffer concentration (1:3 glycine to buffer) was higher than that of glycine. A high-intensity X-ray diffraction method was developed to monitor the phase transitions during the entire freeze-drying cycle. The high sensitivity of SXRD allowed us to monitor all the crystalline phases simultaneously. While DHPD crystallizes in frozen solution, it dehydrates incompletely during primary drying and completely during secondary drying. The impact of initial solute concentration on the phase composition during the entire freeze-drying cycle was quantified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Inclusion Distortion by Lens Shape Effect: In Situ Observation and Quantification on LCAK Steels Using HT-CSLM

Because of interfacial and surface tension, micron-sized liquid oxide droplets are expected to change from spherical (when fully immersed in liquid steel) to lens shape on top of steel. Inclusion sizes were measured by automated analysis of polished sections of calcium-treated aluminum-killed steel. A sample of the same steel was remelted and observed using confocal scanning laser microscopy. Droplets on the steel surface appear to have approximately twice the diameter of fully immersed spherical inclusions.

36 MATERIALS SCIENCE↗

In-situ quantification of the surface roughness for facile fabrications of atomically smooth thin films

Here in this work we present an in-situ technique to quantify the layer-by-layer roughness of thin films and heterostructures by measuring the spectral profile of the reflection high-energy electron diffraction (RHEED). The characteristic features of the diffraction spot, including the vertical to lateral size ratio c/b and the asymmetrical ratio c 1 /c 2 along the vertical direction, are found to be quantitatively dependent on the surface roughness. The quantitative relationships between them are established and discussed for different incident angles of high-energy electrons. As an example, the surface roughnesses of LaCoO 3 films grown at different temperatures are obtained using such an in-situ technique, which are confirmed by the ex-situ atomic force microscopy. Moreover, the in-situ measured layer-by-layer roughness oscillations of two LaCoO 3 films are demonstrated, revealing drastically different information from the intensity oscillations. The experiments assisted with the in-situ technique demonstrate an outstanding high resolution down to similar to ~0.1 Å. Therefore, the new quantitative RHEED technique with real-time feedbacks significantly escalates the thin film synthesis efficiency, especially for achieving atomically smooth surfaces and interfaces. It opens up new prospects for future generations of thin film growth, such as the artificial intelligence-assisted thin film growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Relationship of non-invasive quantification of myocardial blood flow to arrhythmic events in patients with implantable cardiac defibrillators

Background: Ischemia contributes to arrhythmogenesis though its role is incompletely understood. Abnormal myocardial perfusion measured by PET imaging may predict ventricular arrhythmias (VAs) in a high-risk population. Methods: Patients with implantable cardiac defibrillators who had undergone rubidium-82 cardiac PET imaging were identified. Patients were stratified by median MBF and MFR values for analysis. The Cox proportional hazards model was used to assess the impact of myocardial perfusion on survival free of VT independent of critical covariates. Results: A total of 159 patients (124 (78%) males, median age 65.9 years, IQR [56.76-72.63]) were followed for 1.43 years IQR [0.83-2.21]. VA occurred in 29 patients (23.7%). After adjustment for ejection fraction, age, and sex, impaired stress MBF was associated with an increased risk of VA (adjusted HR per ml/min/g 1.52, 95% CI (1.01-2.31), P = 0.04). Summed rest and stress scores were not predictive of VA. Among patients with severe LV dysfunction, stress MBF remained an independent predictor of VA (adjusted HR per 1 ml/min/g HR 1.69, 95% CI (1.03-11.36), P = 0.03), while residual EF, summed rest, and summed stress scores were not (P > 0.05). Conclusions: Impaired stress myocardial blood flow was associated with less survival free of ventricular arrhythmias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC

The above position statement originally published containing errors in the author metadata; specifically, the Expert Content Reviewers—Andrew Einstein, Raymond Russell and James R. Corbett—were tagged as full authors of the paper. The article metadata has now been corrected to remove Drs. Einstein, Russell and Corbett from the author line, and the PubMed record has been updated accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗