Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs↗

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Radial particle-based terrestrial thermocline for high temperature thermal storage

A system or method for thermal storage includes a recess or containment unit having a first storage layer and a second storage layer comprising a permeable filler material. An intermediate layer is disposed between the storage layers. A primary well traverses the layer in the recess. The primary well is in thermal communication with the first permeable filler material and the second permeable filler material. A heat source is provided for heating an inlet fluid. An input pump is in fluid communication with the primary well and the heat source. The primary well receives heated inlet fluid from the inlet pump and injects the fluid into the second layers. The heated inlet fluid transfers heat to the respective permeable filler material radially from the primary well toward an outer periphery of the thermocline recess.

Ho, Clifford K.↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Tests of Aluminum Precipitate Preparation Methods on Head Loss through Debris Beds on a Sump Screen

During a Loss-of-Coolant Accident (LOCA) in Pressurized Water Reactors (PWRs), buffered borated water as a coolant from the Refueling Water Storage Tank (RWST) will be injected into the primary loop to cool down the core depending on the break size. For long-term cooling, the coolant will be collected in the containment sump. Then, the Emergency Core Cooling System (ECCS) will pump the coolant through the sump strainers into the reactor. During this phase, buffered borated water produces chemical precipitate by reacting with the structural materials in the containment. Chemical effects evaluated as part of Generic Safety Issue 191 (GSI-191) resolution studies are broadly defined as any chemically induced phenomenon that affects ECCS performance. Initial chemical effects studies jointly sponsored by the Nuclear Regulatory Commission (NRC) and Industry collaborators led to a Westinghouse Owners Group (WOG) study that provided bases for deterministic quantification of chemical effects. The WCAP-16530-NP developed protocols to produce Aluminum Oxyhydroxide (AlOOH), Calcium Phosphate, and Sodium Aluminum Silicate (SAS). The surrogate generation protocol used the metal salt (aluminum nitrate and calcium acetate) unlike post-LOCA accident scenarios where metals leach into a buffered borated solution. Bahn et al. demonstrated that the WCAP-16530-NP SAS precipitate did not produce as much head loss as the WCAP-16530-NP AlOOH precipitate, thus, the present study focused on the effect of AlOOH precipitate on head loss through a fibrous debris bed. In the past, most of the tests were conducted in high approach velocity conditions, approximately 0.03 m/s. After modifications of sump strainer size in PWRs, the approach velocity to the sump strainer was reduced by an order of magnitude, approximately 0.001 ∼ 0.003 m/s. Howe et al. and Kim et al. conducted several head loss tests at the approach velocity of 0.003 m/s. In the present study, an approach velocity of 0.0006 m/s was selected for an extremely slow power plant condition. A PCI strainer design was used as previous head loss tests and debris bypass tests conducted by Lee et al. Three different chemical precipitate preparation methods were used in this study. The additional head loss of the debris bed caused by those chemical precipitates was investigated. The debris bed was produced with NUKON{sup R} fiberglass thermal insulator and additional particulates including dirt, Tin powder, acrylic powder, and Calcium silicate (CalSil). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Coal-Seq III Consortium. Advancing the Science of CO 2 Sequestration in Coal Seam and Gas Shale Reservoirs

The Coal-Seq consortium is a government-industry collaborative that was initially launched in 2000 as a U.S. Department of Energy sponsored investigation into CO2 sequestration in deep, unmineable coal seams. The consortium’s objective aimed to advancing industry’s understanding of complex coalbed methane and gas shale reservoir behavior in the presence of multi-component gases via laboratory experiments, theoretical model development and field validation studies. Research from this collaborative effort was utilized to produce modules to enhance reservoir simulation and modeling capabilities to assess the technical and economic potential for CO2 storage and enhanced coalbed methane recovery in coal basins. Coal-Seq Phase 3 expands upon the learnings garnered from Phase 1 & 2, which has led to further investigation into refined model development related to multicomponent equations-of-state, sorption and diffusion behavior, geomechanical and permeability studies, technical and economic feasibility studies for major international coal basins the extension of the work to gas shale reservoirs, and continued global technology exchange. The first research objective assesses changes in coal and shale properties with exposure to CO2 under field replicated conditions. Results indicate that no significant weakening occurs when coal and shale were exposed to CO2, therefore, there was no need to account for mechanical weakening of coal due to the injection of CO2 for modeling. The second major research objective evaluates cleat, Cp, and matrix, Cm, swelling/shrinkage compressibility under field replicated conditions. The experimental studies found that both Cp and Cm vary due to changes in reservoir pressure during injection and depletion under field replicated conditions. Using laboratory data from this study, a compressibility model was developed to predict the pore-volume compressibility, Cp, and the matrix compressibility, Cm, of coal and shale, which was applied to modeling software to enhance model robustness. Research was also conducted to improve algorithms and generalized adsorption models to facilitate realistic simulation of CO2 sequestration in coal seams and shale gas reservoirs. The interaction among water and the adsorbed gases, carbon dioxide (CO2), methane (CH4), and nitrogen (N2) in coalbeds is examined using experimental in situ laboratory techniques to comprehensively model CBM production and CO2 sequestration in coals. An equation of state (EOS) module was developed which is capable of predicting the density of pure components and mixtures involving the wet CBM gases CH4, CO2, and N2 at typical reservoir condition, and is used to inform CO2 injection models. The final research objective examined the effects adsorbed CO2 has on coal strength and permeability. This research studied the weakening or failure of coal by the adsorption of CO2 from empirically derived gas production data to develop models for advanced modeling of permeability changes during CO2 sequestration. The results of this research effort have been used to construct a new and improved model for assessing changes in permeability of coal reservoirs due CO2 injection. The modules developed from these studies and knowledge learned are applied to field validation and basin assessment studies. These data were used to assess the flow and storage of CO2 in a shale reservoir, test newly developed code against large-scale projects, and conduct a basin-oriented review of coal storage potential in the San Juan Basin. The storage potential and flow of CO2 was modeled for shale sequestration of a proprietary Marcellus Shale horizontal gas production well using COMET3 simulation software. Simulation results from five model runs indicate that stored CO2 quantities are linked to the duration of primary production preceding injection. Matrix CO2 saturation is observed to increase in each shale zone after injection with an increase in primary production, and the size of the CO2 plume is also observed to increase in size the longer initial production is sustained. The simulation modules developed around the Coal-Seq experimental work are also incorporated into a pre-existing large-scale numerical simulation model of the Pump Canyon CO2-ECBM pilot in the San Juan Basin. The new model was applied to re-history match the data set to explore the improvements made in permeability prediction against previously published data sets and to validate this module. The assessment of the new data, however, indicates that the impact of the variable Cp is negligible on the overall behavior of the coal for CO2 storage purposes. Applying these new modules, the San Juan Basin and the Marcellus Shale are assessed for their technical ECBM/AGR and CO2 storage potential and the economic potential of these operations. The San Juan Basin was divided into 4 unique geographic zones based on production history, and the Marcellus was divided into nine. Each was assessed based upon each zone’s properties, and simulations were run to assess the potential of full Basin development. Models of a fully developed San Juan Basin suggest the potential for up to 104 Tcf of CO2 storage, and 12.3 Tcf of methane recovery. The Marcellus models suggest 1,248 Tcf of CO2 storage and 924 Tcf of AGR. The economics are deemed favorable where credits cover the cost of CO2 in the San Juan Basin, and in many cases in the Marcellus, but to maximize storage potential, credits need to extend to pay the operator to store CO2.

01 COAL, LIGNITE, AND PEAT↗

Modeling the Effects of Groundwater-fed Irrigation on Terrestrial Hydrology over the Conterminous United States

Human alteration of the land surface hydrologic cycle is substantial. Recent studies suggest that local water management practices including groundwater pumping and irrigation could significantly alter the quantity and distribution of water in the terrestrial system, with potential impacts on weather and climate through land-atmosphere feedbacks. In this study, we incorporated a groundwater withdrawal scheme into the Community Land Model version 4 (CLM4). To simulate the impact of irrigation realistically, we calibrated the CLM4 simulated irrigation amount against observations from agriculture census at the county scale over the conterminous United States (CONUS). The water used for irrigation was then removed from the surface runoff and groundwater aquifer according to a ratio determined from the county-level agricultural census data. Based on the simulations, the impact of groundwater withdrawals for irrigation on land surface and subsurface fluxes were investigated. Our results suggest that the impacts of irrigation on latent heat flux and potential recharge when water is withdrawn from surface water alone or from both surface and groundwater are comparable and local to the irrigation areas. However, when water is withdrawn from groundwater for irrigation, greater effects on the subsurface water balance were found, leading to significant depletion of groundwater storage in regions with low recharge rate and high groundwater exploitation rate. Our results underscore the importance of local hydrologic feedbacks in governing hydrologic response to anthropogenic change in CLM4 and the need to more realistically simulate the two-way interactions among surface water, groundwater, and atmosphere to better understand the impacts of groundwater pumping on irrigation efficiency and climate.

conterminous↗

Evaluation of advanced component concepts for an integrated environmental control/life support, resistojet control system

Flow restricting devices were studied for their suitability as liquid water propellant flow limiters for the biowaste resistojet. Flow limiting during the start-up transient is required to prevent thrustor instabilities and icing which could result in heater failure in the electrical resistance heated thrustor (resistojet). The study was directed toward simple devices which would function passively (i.e., without power except from the propellant flow itself), and would offer high reliability and simplicity. In addition to the flow limiting devices, a thermal pumping system was studied to determine whether CO2, desorbed from molecular sieves could be pumped thermally in a space station application. The thermal pump is considered a possible replacement for mechanical pumps. It involves a cyclic, constant volume cryopumping system which employs space radiators to achieve the cryotemperatures. The frozen CO2 would be vaporized periodically, using a waste heat loop, to attain sufficient pressure to transfer a large portion of the trapped CO2 to storage tanks.

Halbach, C. R.↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Power System Evaluated for the Human Exploration of Mars

The electric power system is a crucial element of any mission for the human exploration of the Martian surface. The bulk of the power generated will be delivered to crew life support systems, extravehicular activity suits, robotic vehicles, and predeployed in situ resource utilization (ISRU) equipment. In one mission scenario, before the crew departs for Mars, the ISRU plant operates for 435 days producing liquefied methane and oxygen for ascent-stage propellants and water for crew life support. About 200 days after ISRU production is completed, the crew arrives for a 500-day surface stay. In this scenario, the power system must operate for a total of 1130 days (equivalent to 1100 Martian "sols"), providing 400 MW-hr of energy to the ISRU plant and up to 18 kW of daytime user power. A photovoltaic power-generation system with regenerative fuel cell (RFC) energy storage has been under study at the NASA Glenn Research Center at Lewis Field. The conceptual power system is dominated by the 4000- m2 class photovoltaic array that is deployed orthogonally as four tent structures, each approximately 5 m on a side and 100-m long. The structures are composed of composite members deployed by an articulating mast, an inflatable boom, or rover vehicles, and are subsequently anchored to the ground. Array panels consist of thin polymer membranes with thin-film solar cells. The array is divided into eight independent electrical sections with solar cell strings operating at 600 V. Energy storage is provided by regenerative fuel cells based on hydrogen-oxygen proton exchange membrane technology. Hydrogen and oxygen reactants are stored in gaseous form at 3000 psi, and the water produced is stored at 14.7 psi. The fuel cell operating temperature is maintained by a 40-m2 deployable pumped-fluid loop radiator that uses water as the working fluid. The power management and distribution (PMAD) architecture features eight independent, regulated 600-Vdc channels. Power management and distribution power cables use various gauges of copper conductors with ethylene tetrafluoroethylene insulation. To assess power system design options and sizing, we developed a dedicated Fortran code to predict detailed power system performance and estimate system mass. This code also modeled the requisite Mars surface environments: solar insolation, Sun angles, dust storms, dust deposition, and thermal and ultraviolet radiation. Using this code, trade studies were performed to assess performance and mass sensitivities to power system design parameters (photovoltaic array geometry and orientation) and mission parameters (landing date and landing site latitude, terrain slope, and dust storm activity). Mission analysis cases were also run. Power results are shown in this graph for an analysis case with a September 1, 2012, landing date; 18.95 North latitude landing site; two seasonal dusts storms; and tent arrays. To meet user load requirements and the ISRU energy requirement, an 8-metric ton (MT) power system and 4000-m2 photovoltaic array area were required for the assumed advanced CuInS2 thin-film solar cell technology. In this figure, the top curve is the average daytime photovoltaic array power, the middle curve is average daytime user load power, and the bottom curve is nighttime power. At mission day 1, daytime user power exceeds 120 kW before falling off to 80 kW at the end of the mission. Throughout the mission, nighttime user power is set to the nighttime power requirement. In this analysis, "nighttime" is defined as the 13- to 15-hr period when array power output is below the daytime power requirement. During dust storms, power system capability falls off dramatically so that by mission day 900, a daily energy balance cannot be maintained. Under these conditions, the ISRU plant is placed in standby mode, and the regenerative fuel cell energy storage is gradually discharged to meet user loads.

Kerslake, Thomas W.↗

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Design and Build of Reactor Simulator for Fission Surface Power Technology Demonstrator Unit

The Nuclear Systems Team at NASA Marshall Space Flight Center (MSFC) focuses on technology development for state of the art capability in non-nuclear testing of nuclear system and Space Nuclear Power for fission reactor systems for lunar and Mars surface power generation as well as radioisotope power systems for both spacecraft and surface applications. Currently being designed and developed is a reactor simulator (RxSim) for incorporation into the Technology Demonstrator Unit (TDU) for the Fission Surface Power System (FSPS) Program, which is supported by multiple national laboratories and NASA centers. The ultimate purpose of the RxSim is to provide heated NaK to a pair of Stirling engines in the TDU. The RxSim includes many different systems, components, and instrumentation that have been developed at MSFC while working with pumped NaK systems and in partnership with the national laboratories and NASA centers. The main components of the RxSim are a core, a pump, a heat exchanger (to mimic the thermal load of the Stirling engines), and a flow meter for tests at MSFC. When tested at NASA Glenn Research Center (GRC) the heat exchanger will be replaced with a Stirling power conversion engine. Additional components include storage reservoirs, expansion volumes, overflow catch tanks, safety and support hardware, instrumentation (temperature, pressure, flow) for data collection, and power supplies. This paper will discuss the design and current build status of the RxSim for delivery to GRC in early 2012.

Godfroy, Thomas↗

Automated High-Pressure Titration System with In Situ Infrared Spectroscopic Detection

A fully automated titration system with infrared detection was developed for investigating interfacial chemistry at high pressures. The apparatus consists of a high-pressure fluid generation and delivery system coupled to a high-pressure cell with infrared optics. A manifold of electronically actuated valves is used to direct pressurized fluids into the cell. Precise reagent additions to the pressurized cell are made with calibrated tubing loops that are filled with reagent and placed in-line with the cell and a syringe pump. The cell’s infrared optics facilitate both transmission and attenuated total reflection (ATR) measurements to monitor bulk-fluid composition and solid-surface phenomena such as adsorption, desorption, complexation, dissolution, and precipitation. Switching between the two measurement modes is accomplished with moveable mirrors that direct radiation from a Fourier transform infrared spectrometer into the cell along transmission or ATR light paths. The versatility of the high-pressure IR titration system is demonstrated with three case studies. First, we titrated water into supercritical CO2 (scCO2) to generate an infrared calibration curve and determine the solubility of water in CO2 at 50 °C and 90 bar. Next, we characterized the partitioning of water between a montmorillonite clay and scCO2 at 50 °C and 90 bar. Transmission-mode spectra were used to quantify changes in the clay’s sorbed water concentration as a function of scCO2 hydration, and ATR measurements provided insights into competitive residency of water and CO2 on the clay surface and in the interlayer. Finally, we demonstrated how time-dependent studies can be conducted with the system by monitoring the carbonation reaction of forsterite (Mg2SiO4) in water-bearing scCO2 at 50 °C and 90 bar. Immediately after water dissolved in the scCO2, a thin film of adsorbed water formed on the mineral surface, and the film thickness increased with time as the forsterite began to dissolve. However, after approximately 2.5 hours, the trend reversed, and a carbonate precipitate began to form on the forsterite surface, exposing dramatic chemical changes in the thin-water film. Collectively, these applications illustrate how the high-pressure IR titration system can provide molecular-level information about the interactions between variably wet scCO2 and minerals relevant to underground storage of CO2 (geologic carbon sequestration). The apparatus could also be utilized to study high-pressure interfacial chemistry in other areas such as catalysis, polymerization, food processing, and oil and gas recovery.

Environmental Molecular Sciences Laboratory↗

Proxy-based Bayesian inversion of strain tensor data measured during well tests

Recent instrument developments have made it possible to measure the strain tensor caused by injecting or pumping fluid from aquifers or reservoirs, but the full value of these data is limited because the long runtimes of poroelastic forward models makes it impractical to use many inversion schemes. This limits the interpretation of strain data for managing the recovery of resources or storage of wastes in the subsurface. This paper describes a method of inverting deformation data using a poroelastic numerical simulator so the results can be used to manage reservoirs or aquifers. We developed a workflow designed to reduce the number of simulations sufficiently to make it feasible to use DREAMzs, an advanced Bayesian inversion method that translates the uncertainties from different sources into unbiased posterior parameter distributions and uncertainty envelopes around the field data. Using a KNN proxy model for the poroelastic simulator is key to reducing the overall computations, and the workflow includes a strategy for ensuring the proxy model results converge on the results from the simulator. The workflow is tested using an idealized example that verifies the ability to correctly identify parameters and characterize noise used to perturb the data. Field data from an injection test at an oil reservoir near Tulsa, Oklahoma, are also used to evaluate the efficacy of the workflow with a real dataset. The workflow identified 265 history matching solutions out of 1240 total simulation runs (21% acceptance ratio), where the results were used to characterize posterior parameter distribution and evaluate the prediction uncertainty. Furthermore, this workflow is significant because it enables strain tensor, or other geomechanical measurements to be interpreted to guide decision-making during energy and environmental processes in the subsurface.

42 ENGINEERING↗

Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

Appelbaum, Joseph↗

Containing Hair During Cutting In Zero Gravity

Proposed device collects loose hair during barbering and shaving in zero gravity to prevent hair clippings from contaminating cabin of spacecraft. Folds for storage, opens into clear, bubblelike plastic dome surrounding user's head, tray fits around user's throat, and fanlike ring surrounds back of neck. Device fits snugly but comfortably around neck, preventing hair from escaping to outside. Flow of air into hose connected to suction pump removes hair from bubble as cut. Filter at end of hose collects hair.

Haines, Richard F.↗