Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Protection of battery electrodes against side reactions

A battery electrode composition is provided that comprises composite particles. Each of the composite particles in the composition (which may represent all or a portion of a larger composition) may comprise a porous electrode particle and a filler material. The porous electrode particle may comprise active material provided to store and release ions during battery operation. The filler material may occupy at least a portion of the pores of the electrode particle. The filler material may be liquid and not substantially conductive with respect to electron transport.

Yushin, Gleb↗

Privacy-Protected Simultaneous Provision of Energy and Primary Frequency Control Reserve

This paper investigates a Mixed Integer Linear Programming (MILP) model for simultaneous scheduling of energy and primary frequency control reserve. Given the model’s unique structure and growing concerns about privacy, we adopt Dantzig-Wolfe Decomposition (DWD) algorithm to solve the problem in a decentralized fashion while obfuscating the privacy of the energy and reserve resources. Additionally, we present a novel criterion for checking the model’s feasibility. Finally, simulation results are given and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fire Protection Design

The purpose of this project is to design the demolition and installation of a deluge valve swap from a DV-5 to a DV-5A valve.

99 GENERAL AND MISCELLANEOUS↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Safe Operations at Roadway Junctions - Design Principles from Automated Guideway Transit

Herein this paper describes a system-level view of a fully automated transit system comprising a fleet of automated vehicles (AVs) in driverless operation, each with an SAE level 4 Automated Driving System, along with its related safety infrastructure and other system equipment. This AV system-level control is compared to the automatic train control system used in automated guideway transit technology, particularly that of communications-based train control (CBTC). Drawing from the safety principles, analysis methods, and risk assessments of CBTC systems, comparable functional subsystem definitions are proposed for AV fleets in driverless operation. With the prospect of multiple AV fleets operating within a single automated mobility district, the criticality of protecting roadway junctions requires an approach like that of automated fixed-guideway transit systems, in which a guideway switch zone "interlocking" at each junction location deconflicts railway traffic, affirming safe passage. The analogous AV protection safety subsystem is defined as fail-safe equipment that monitors roadway intersections and junctions, communicates traffic signal status, perceives and communicates alerts and signals to AV connected vehicles concerning potential unsafe conditions, and performs related primary safety functions. Conclusions are drawn that the AV protection roadway intersection functions must be performed by local roadside equipment dedicated to protecting each roadway intersection and junction. Further, it is concluded that the communications technology connecting the infrastructure with the vehicle to perform this vital, fail-safe protection should meet specific functional and performance criteria.

33 ADVANCED PROPULSION SYSTEMS↗

US Fallout Shelter

Being indoors (sheltering) reduces radiation exposures resulting from nuclear fallout or a power-plant accident. However, most US building types, particularly non-residential buildings, lack quantitative estimates. We provide here a high-level modeling analysis of modern US building protection based on a novel radiation protection building attribute taxonomy, a new building protection model, compilation of prior experimental results, and nationally representative building survey data. This approach provides a consistent, quantitative understanding of US building protection and, when combined with the distribution of people among different buildings, can assist in selecting emergency response strategies. We find that indoor radiation protection varies by orders of magnitude. Most people in non-residential buildings are adequately protected, particularly below ground or in the building center. Residential buildings are less protective and those with lighter weight walls lack adequate, above ground protection. This work also highlights key areas where further investigation will improve the current results. These include the improving the understanding of residential basement protection, additional experimental data on non-residential buildings (particularly schools and industrial buildings), and the frequency of brick veneer and stucco exterior residential buildings.

61 RADIATION PROTECTION AND DOSIMETRY↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FUN-BioCROP model with litter decomposition parameters derived from the LIDET dataset

This repository contains the code and data necessary to run the FUN-BioCROP (Fixation and Uptake of Nitrogen-Bioenergy Carbon, Rhizosphere, Organisms, and Protection) model with litter decomposition parameters derived from a modified Monte Carlo simulation that used the Long-term Intersite Decomposition Experiment Team dataset. Related publication:Juice, S.M., Ridgeway, J.R., Hartman, M.D., Parton, W.J., Berardi, D.M., Sulman, B.N., Allen, K.E., & Brzostek, E.R. Reparameterizing litter decomposition using a simplified Monte Carlo method improves litter decay simulated by a microbial model and alters bioenergy soil carbon estimates. Description of Files: FUNBioCROP_LIDET Study.Rmd R code with FUN-BioCROP model that can be run with 10 different sets of parameters for litter decomposition (Baseline, LIDET, or eight other best parameter sets identified in the modified Monte Carlo simulation. CORPSE Functions_Bioenergy_V2.R Code with CORPSE model functions, called by FUNBioCROP_LIDET Study.Rmd Model Input Data: bulk.csv, bulk_till.csv, rhizo.csv, rhizo_till.csv, litter.csv Initial C and N (kg C or N/m2) pool values for each soil compartment, final values from spin up. All five files have the same columns: (Column - Description - Units) uFastC - Unprotected fast decomposing carbon - kg carbon/m2 uSlowC - Unprotected slow decomposing carbon - kg carbon/m2 uNecroC - Unprotected necromass carbon - kg carbon/m2 pFastC - Protected fast decomposing carbon - kg carbon/m2 pSlowC - Protected slow decomposing carbon - kg carbon/m2 pNecroC - Protected necromass carbon - kg carbon/m2 livingMicrobeC - Carbon in living microbial biomass - kg carbon/m2 uFastN - Unprotected fast decomposing nitrogen - kg nitrogen/m2 uSlowN - Unprotected slow decomposing nitrogen - kg nitrogen/m2 uNecroN - Unprotected necromass nitrogen - kg nitrogen/m2 pFastN - Protected fast decomposing nitrogen - kg nitrogen/m2 pSlowN - Protected slow decomposing nitrogen - kg nitrogen/m2 pNecroN - Protected necromass nitrogen - kg nitrogen/m2 inorganicN - Inorganic nitrogen - kg nitrogen/m2 CO2 - Carbon in carbon dioxide - kg carbon/m2 livingMicrobeN - Nitrogen in living microbial biomass - kg nitrogen/m2 Model Input Data: FluxTower_AvgSoilT.csv: Average daily soil temperature (oC) at 10 cm depth at University of Illinois Urbana-Champaign (UIUC) Energy Farm flux tower from 7/2008-3/2016. (One year of averaged data) Model Input Data: FluxTower_AvgSoilVWC.csv: Average daily soil volumetric water content (VWC) at 10 cm depth at UIUC Energy Farm flux tower from 7/2008-3/2016. (One year of averaged data) Model Input Data: input_CCS_LIDET Study.csv: This file has daily data to run FUN-BioCROP (Column - Description - Units): yr - calendar year - year doy - day of year (1 to 365) (no leap year) - day anpp - aboveground NPP (DayCent) - kg C/m2/day bnpp - belowground NPP (DayCent) - kg C/m2/day aglivc - live aboveground biomass carbon (DayCent) - kg C/m2 bglivcj - live juvenile fine root biomass carbon (DayCent) - kg C/m2 bglivcm - live mature fine root biomass carbon (DayCent) - kg C/m2 aglivn - live aboveground biomass nitrogen (DayCent) - kg N/m2 bglivnj - live juvenile fine root biomass nitrogen (DayCent) - kg N/m2 bglivnm - live mature fine root biomass nitrogen (DayCent) - kg N/m2 nyr - simulation year - year cult - indicates a cultivation event (0 or 1) crop - indicates a new crop (0 or 1) fert - indicates a fertilizer event (0 or 1) frst - indicates the first day of the growing season (0 or 1) harv - indicates a harvest event (0 or 1) last - indicates the end of the growing season (0 or 1) croptype - crop type (0=none; 1=alfalfa; 2=corn; 3=grass clover pasture; 4=soybean; 5=wheat) cropsrl - crop specific root length - mm/g root cultrhizmix - fraction of rhizosphere mixed with bulk soil during cultivation (0.0-1.0) - fraction cultlitmix - fraction of litter mixed with bulk soil during cultivation (0.0-1.0) - fraction harvremov - fraction of above ground biomass removed during harvest (0.0-1.0) - fraction fertamt - fertilization amount - g N/m2 lifehist - plant life history (0 = annual, 1 = perennial) froot_turnover_c - amount of C in fine root turnover - kg C/m2 froot_turnover_n - amount of N in fine root turnover - kg N/m2 agrd_turnover_c - amount of C in aboveground biomass turnover - kg C/m2 agrd_turnover_n - amount of N in aboveground biomass turnover - kg N/m2 leaf_litter_fastfrac - Fast decomposing fraction of leaf litter (0.0-1.0) - fraction root_litter_fastfrac - Fast decomposing fraction of root litter (0.0-1.0) - fraction root_diameter - root diameter - mm root_length - root length - mm root/m2 rhizo_frac - fraction of total soil volume that is rhizosphere (0.0 - 1.0) - fraction date - date in format YYYY-MM-DD Instructions: Save the model code ("FUN-BioCROP_LIDET Study.Rmd") and accompanything files (data streams and CORPSE function code) in the same folder. In model code "Chunk 3: Load CORPSE Data Streams" set the working directory (setwd) to the folder with the files saved in step #1. In "Chunk 5: Define LIDET parameter sets" select the litter decomposition parameter set to be used in the run, and comment out all other sets. If changing any parameter values, edit them in "Chunk 6: Load parameters." Run all chunks up to and including "Chunk 10: Prepare Data for Export." In "Chunk 11: Export Output Data" edit data frames for export and filenames, as necessary. "Chunk 12: Graph Total Soil C" makes a figure of C remaining over the model run period. Description of each model chunk (in file FUN-BioCROP_LIDET Study.Rmd): Chunk 1: Remove all functions, clear memory. Removes all functions from R environment, clears the memory. Chunk 2: Load Packages. Loads packages necessary to run the code. Chunk 3: Load CORPSE Data Streams. Sets the working directory and loads the data files necessary to run CORPSE. Chunk 4: Load CORPSE Functions. Loads the R script with CORPSE functions from the working directory, "CORPSE Functions_Bioenergy_V2.R". Chunk 5: Define LIDET parameter sets. Has ten different parameter sets for litter decomposition tested in this study: Baseline parameters, LIDET parameters, and the other 8 best performing parameter sets identified in the modified Monte Carlo. To run the model, all but one parameter set must be commented out. Chunk 6: Load Parameters. Loads all fixed parameters to run the model. Data frame with definitions of parameters is in the CORPSE function script "CORPSE Functions_Bioenergy_V2.R" Chunk 7: Prepare Data Streams. Takes data streams loaded in Chunk 3 and puts them in the format necessary to run the model. The model is coded to run at least two sites at a time, so if only one site is being run it must be run in duplicate. Individual data tables of daily values are created in this chunk from the input data file. Chunk 8: Set Initial Conditions. Creates data tables of soil C and N pools for each soil compartment (rhizo_till, rhizo, bulk_till, bulk, litter) and loads initial values into the data tables. Creates lists for each soil compartment to hold model output. Chunk 9: Load FUN Data and Set Up Matrices. Uses DayCent data to calculate FUN input data: root and leaf N demand, total N demand, plant CN, leaf N available for retranslocation, and litter production. Creates matrices for FUN model outputs. Chunk 10: Run Model. Runs the model. Chunk 11: Prepare Data for Export. Combines data from each day saved as lists into data frames for each soil compartment. Adds values from all soil compartments together to calculate total soil values, creates separate data frames for each soil C and N pool (e.g., protected slow C) for the total soil value. Adds different C and N pools together to calculate total soil C and N for all layers. Creates data frame of ratio of protected to unprotected SOC. Organizes FUN data for export. Chunk 12: Export Results. Exports CSV files of model results to the working directory. Chunk 13: Graph Total Soil C. Makes figure of C remaining over time. Related Links: Original FUN-BioCROP model: https://github.com/BrzostekEcologyLab/FUN-BioCROP LIDET dataset: https://andlter.forestry.oregonstate.edu/data/abstract.aspx?dbcode=TD023

Juice, Stephanie↗

Isothermal oxidation of zirconium using steam

Oxidation of zirconium and its alloys under any atmosphere is generally characterised by a protective and non-protective stage. During the protective stage, the kinetics of oxidation are quasi-parabolic, while the oxide scale formed on the surface of the metal is black, compact, and protective in nature. For the non-protective stage, the oxidation rate becomes linear, while the protective oxide film turns into a deteriorated white scale. Breakaway is known as the transition point from protective to non-protective stage. The actual mechanism leading to breakaway of zirconium is still a matter of controversy, however some of the most common factors affecting breakaway are the following: - Impurities on the metal (Carbon, Oxygen, Nitrogen); - Oxidizing atmosphere (Presence of H{sub 2}O (g) or N{sub 2} (g)); - Sample preparation (Chemically etched or polished); - Temperature (LWR, LOCA). This research investigates the effect of temperature on 'breakaway' when zirconium is oxidized isothermally in steam for 60 min at 800 and 900 deg. C using thermogravimetric and optical microscopic imaging techniques. 1. Steam isothermal oxidations were performed on zirconium at 800 and 900 deg. C using a Thermogravimetric Analyzer (TGA). 2. Log-log plots of mass gain vs time were obtained from thermogravimetric results to calculate the reaction orders (n) and reaction rate constants (K) during oxidation. 3. Results of the kinetics of reaction were correlated with optical microscopic images form Light Microscope (LM) and Scanning Electron Microscope (SEM). Breakaway depends very strongly on temperature. At 800 deg. C, the weight gain followed a cubic-parabolic behaviour with evidence of a protective oxide film. On the other hand, oxidation at 900 deg. C showed signs of breakaway since the oxide film was cracked and oxidation rate was almost linear throughout the reaction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion of Stainless and Carbon Steel in Aqueous Piperazine for CO2 Capture

Current obstacles that prevent commercial implementation of amine-scrubbing CO2 capture are the high costs. Reducing capital costs by appropriate selection of construction materials, which requires knowledge of material corrosion performance for the process, will improve the economic feasibility of this technology. Corrosion was evaluated in three pilot plant campaigns using aqueous piperazine with the Advanced Stripper (PZAS). 316L stainless steel (SS) experienced higher corrosion than 304 SS and 2205 duplex SS, and the corrosion rate showed strong dependence on the temperature. 304 and 2205 performed well at all locations and should be good construction materials for PZAS. Degraded PZ exacerbated 316L corrosion, and removal of PZ degradation products using a carbon adsorption bed significantly reduced corrosion. Carbon steel (CS) corrosion showed a weak temperature effect because the corrosion was more dependent on the protective siderite film. The protectiveness of the films was related to fluid velocity. Ni-based alloys corroded in PZ, and the rate increased with temperature. Corrosion of C1010 CS and SS (304, 316L, 430) was measured at absorber and water wash conditions on the bench-scale. Corrosion rate decreases with increasing PZ. 8 With more than 0.003 m PZ in solution, CS has acceptable corrosion performance. Corrosion of CS increases with increasing partial pressure of CO2, suggesting loading is another dominant parameter for carbon steel corrosion. Temperature has a less significant effect than PZ concentration and loading. CS corrosion increases with increasing flow velocity at both absorber and water wash conditions. SS had little corrosion at this lower temperature. Performance of siderite (FeCO3) protective films on CS was studied at representative stripper conditions on the bench-scale. Siderite films can deposit on the surface of CS in CO2-loaded PZ solution at temperatures >100 °C and protect CS from corrosion. The protection may fail in degraded PZ. Ethylenediamine (EDA) is one of the major contributors for the loss of film protectiveness or can be the surrogate for the effect of PZ degradation on siderite film protection. A link between protectiveness and the apparent density of siderite films was discovered. The apparent density of siderite films decreases with increasing flow velocity and decreasing CO2 loading, resulting in higher corrosion of CS.

Liu, Ching-Ting↗