Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

An alternative viewpoint on the nuclear structure towards 100 Sn: Lifetime measurements in 105 Sn

This work aims at presenting an alternative approach to the long standing problem of the B(E2) values in Sn isotopes in the vicinity of the N=Z double-magic nucleus 100 Sn, until now predominantly measured with relativistic and intermediate-energy Coulomb excitation reactions. The direct measurement of the lifetime of low-lying excited states in odd-even Sn isotopes provides a new and precise guidance for the theoretical description of the nuclear structure in this region. Lifetime measurements have been performed in 105 Sn for the first time with the coincidence Recoil Distance Doppler Shift technique. The lifetime results for the $7/2^+_1$ first excited state and the $11/2^+_1$ state, $2^+ (^{104}$Sn) Ⓧ $v1g_{7/2}$ multiplet member, are discussed in comparison with state-of-the-art shell model and mean field calculations, highlighting the crucial contribution of proton excitation across the core of 100 Sn. The reduced transition probability B(E2) of the $11/2^+_1$ core-coupled state points out an enhanced staggering with respect to the B(E2; $2^+_1$ → $0^+_1$) in the even-mass 104 Sn and 106 Sn isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Platform at the Matter in Extreme Conditions End Station for Characterization of Matter Heated by Intense Laser-Accelerated Protons

High intensity short-pulse lasers have made possible the generation of energetic proton beams, unlocking numerous applications in high energy density science. One such application is uniform and isochoric heating of materials to the warm dense matter (WDM) state. We have developed a new experimental platform to simultaneously create and probe warm dense matter at the Matter in Extreme Conditions (MEC) end station at the Linac Coherent Light Source (LCLS). The short pulse optical laser (delivering up to 1 J in 45 fs) and the ultra-bright LCLS x-ray laser with tunable frequency respectively deliver high power required to heat materials to WDM and precision-timed high-resolution x-rays to probe them. The laser-accelerated proton beam driven from a flat 1.5 μm Cu foil was first measured then directed to a secondary sample of Al or polypropylene, typically 300-400 μm away. The time evolution of the sample electron temperature was measured using streaked optical pyrometry, where we observed a peak temperature of 0.9 0.15 eV on the rear surface of an Al sample heated by the proton beam. Here, the simulations using the hybrid-PIC code LSP and the rad-hydro code HELIOS show that a measured proton beam can heat Al to approximately 4 eV and polypropylene to 1 eV if instead focused by a hemispherical Cu target. Through additional LSP simulations, we anticipate creating hotter warm dense matter states (20 eV) by increasing the laser energy to 10 J and keeping the other laser parameters fixed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coso Geothermal Spectral Library for Rocks and Minerals

An integrated open mineral spectral library designed to enhance the utility and precision of mineral spectral data for geothermal exploration, developed from a reliable and comprehensive digital dataset for seamless sharing by integrating field data, the USGS spectral library, and pertinent information obtained from Coso geothermal field (Coso) in California. The ASD FieldSpec portable spectrometer was utilized for collecting spectral data, which was subsequently analyzed using the THOR Material Identification tool in ENVI, The Spectral Geologist (TSG) software by CSIRO, and the Fully Constrained Linear Spectral Unmixing algorithm (FCLSU) in MATLAB. Scanning Electron Microscopy (SEM) with a mineralogy-analyzing function was employed to assess the mineral composition of samples, ensuring precise mineralogical analysis. A portable X-ray fluorescence (pXRF) spectrometer was also utilized to gather information on elemental enrichment. A framework for developing spectra data and establishing spectral libraries for various geological cases was proposed within this study. The characteristic spectra of six alteration minerals - alunite, chalcedony, epidote, hematite, kaolinite, and opal - were acquired from Coso samples. The spectral library for the Coso alteration minerals was introduced for further application in academic study or industrial exploration. To browse the Coso Geothermal Spectral data and related figures from spreadsheets: #1 Unzip and store the following items in the same folder. 'Contact Probe Data.zip', 'Sample Photos.zip', and 'Coso spectra of higher-certainity minerals.xlsx'. #2 Open 'Coso spectra of higher-certainity minerals.xlsx'. The hyperlinks in the spreadsheet lead to the folders or figures of: spectra .asd file, spectra ASC II file, spectra plots, and sample photos. The spectra data is raw data without splice correction. Spectra .asd files require particular software to open. (These cannot be opened in GIS software such as ArcGIS.) Spectra ASC II files can be opened in a text editor or spread sheet program.

15 GEOTHERMAL ENERGY↗

Scanning Tunneling Optical Resonance Microscopy

Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.

Bailey, Sheila↗

Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Finally, combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

DIGS: deep inference of galaxy spectra with neural posterior estimation

Abstract With the advent of billion-galaxy surveys with complex data, the need of the hour is to efficiently model galaxy spectral energy distributions (SEDs) with robust uncertainty quantification. The combination of simulation-based inference (SBI) and amortized neural posterior estimation (NPE) has been successfully used to analyse simulated and real galaxy photometry both precisely and efficiently. In this work, we utilise this combination and build on existing literature to analyse simulated noisy galaxy spectra. Here, we demonstrate a proof-of-concept study of spectra that is (a) an efficient analysis of galaxy SEDs and inference of galaxy parameters with physically interpretable uncertainties; and (b) amortized calculations of posterior distributions of said galaxy parameters at the modest cost of a few galaxy fits with Markov chain Monte Carlo (MCMC) methods. We utilise the SED generator and inference framework Prospector to generate simulated spectra, and train a dataset of 2 × 10 6 spectra (corresponding to a five-parameter SED model) with NPE. We show that SBI—with its combination of fast and amortized posterior estimations—is capable of inferring accurate galaxy stellar masses and metallicities. Our uncertainty constraints are comparable to or moderately weaker than traditional inverse-modelling with Bayesian MCMC methods (e.g. 0.17 and 0.26 dex in stellar mass and metallicity for a given galaxy, respectively). We also find that our inference framework conducts rapid SED inference (0.9–1.2 × 10 5 galaxy spectra via SBI/NPE at the cost of 1 MCMC-based fit). With this work, we set the stage for further work that focuses of SED fitting of galaxy spectra with SBI, in the era of JWST galaxy survey programs and the wide-field Roman Space Telescope spectroscopic surveys.

spectroscopy↗

Nonradiative relaxation dynamics in the [Au 25- n Ag n (SH) 18 ] -1 ( n = 1, 12, 25) thiolate-protected nanoclusters

Evaluation of the electron-nuclear dynamics and relaxation mechanisms of gold and silver nanoclusters and their alloys is important for future photocatalytic, light harvesting, and photoluminescence applications of these systems. In this work, the effect of silver doping on the nonradiative excited state relaxation dynamics of the atomically precise thiolate-protected gold nanocluster [Au 25- n Ag n (SH) 18 ] –1 ( n = 1, 12, 25) is studied theoretically. Time-dependent density functional theory is used to study excited states lying in the energy range 0.0–2.5 eV. The fewest switches surface hopping method with decoherence correction was used to investigate the dynamics of these states. The HOMO–LUMO gap increases significantly upon doping of 12 silver atoms but decreases for the pure silver nanocluster. Doped clusters show a different response for ground state population increase lifetimes and excited state population decay times in comparison to the undoped system. The ground state recovery times of the S 1 –S 6 states in the first excited peak were found to be longer for [Au 13 Ag 12 (SH) 18 ] –1 than the corresponding recovery times of other studied nanoclusters, suggesting that this partially doped nanocluster is best for preserving electrons in an excited state. The decay time constants were in the range of 2.0–20 ps for the six lowest energy excited states. Among the higher excited states, S 7 has the slowest decay time constant although it occurs more quickly than S 1 decay. Overall, these clusters follow common decay time constant trends and relaxation mechanisms due to the similarities in their electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micromachined TWTs for THz Radiation Sources

The Terahertz (THz) region of the electromagnetic spectrum (about 300 - 3000 GHz in frequency or about 0.1 - 1 mm free space wavelength) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. It has been characterized as the most scientifically rich, yet under-utilized, region of the electromagnetic spectrum. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.001 - 1.0 W continuous wave), efficient (> 1%), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and comparatively inexpensive. To develop vacuum electron device (VED) radiation sources satisfying these requirements, fabrication and packaging approaches must be heavily considered to minimize costs, in addition to the basic interaction physics and circuit design. To minimize size of the prime power supply, beam voltage must be minimized, preferably 10 kV. Solid state sources satisfy the low voltage requirement, but are many orders of magnitude below power, efficiency, and bandwidth requirements. On the other hand, typical fast-wave VED sources in this regime (e.g., gyrotrons, FELs) tend to be large, expensive, high voltage and very high power devices unsuitable for most of the applications cited above. VEDs based on grating or inter-digital (ID) circuits have been researched and developed. However, achieving forward-wave amplifier operation with instantaneous fractional bandwidths > 1% is problematic for these devices with low-energy (< 15 kV) electron beams. Moreover, the interaction impedance is quite low unless the beam-circuit spacing is kept particularly narrow, often leading to significant beam interception. One solution to satisfy the THz source requirements mentioned above is to develop micromachined VEDs, or "micro-VEDs". Among other benefits, micro-machining technologies provide superior high frequency wall conductivity as a result of superior surface smoothness compared with conventional mechanical or electric discharge machining approaches. Micro-VED technologies are already being applied to the development of millimeter-wave klystrons at Stanford Linear Accelerator Center and submillimeter-wave klystrons at the University of Leeds. We are investigating the use of micro-machining technologies to develop THz regime TWTs, with emphasis on folded-waveguide TWTs. The folded-waveguide TWT (FW-TWT) has several features that make it attractive for THz-regime micro-VED applications. It is a relatively simple circuit to design and fabricate, it is amenable to precision pattern replication by micro-machining, and it is has been demonstrated capable of forward-wave amplification with appreciable bandwidth. We are conducting experimental and computational studies of micro-VED FW-TWTs to examine their feasibility for applications at frequencies from 200 - 1000 GHz.

Booske, John H.↗

Broad-range tuning of ferroelectric switching of La x Bi 1−x FeO 3 epitaxial films via digital doping using off-axis co-sputtering

To investigate the scope of ferroelectric behavior in La-substituted BiFeO 3 films, La x Bi 1−x FeO 3 epitaxial films were synthesized using off-axis co-sputtering on SrTiO 3 (001) and DyScO 3 (110) substrates with a SrRuO 3 bottom electrode layer. A digital-doping deposition method was used to enable precise control and continuous tuning of La concentration in high-quality LaxBi 1−x FeO 3 films across a wide range of x = 0.05–0.60, which was systematically investigated using piezoresponse force microscopy. Robust and reversible out-of-plane ferroelectric switching has been observed up to x = 0.35, while films with x ≥ 0.37 exhibit no measurable ferroelectric behavior, indicating a sharp ferroelectric-to-paraelectric phase transition between x = 0.35 and 0.37. This represents the highest reported La concentration in LaxBi 1−x FeO 3 films that retains ferroelectric ordering, highlighting opportunities to engineer ferroelectric and multiferroic properties in complex oxide heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Astrometry With the Hubble Space Telescope: Trigonometric Parallaxes of Planetary Nebula Nuclei NGC 6853, NGC 7293, ABELL 31, and DeHt 5

We present absolute parallaxes and relative proper motions for the central stars of the planetary nebulae NGC 6853 (The Dumbbell), NGC 7293 (The Helix), Abell 31, and DeHt 5. This paper details our reduction and analysis using DeHt 5 as an example. We obtain these planetary nebula nuclei (PNNi) parallaxes with astrometric data from Fine Guidance Sensors FGS 1r and FGS 3, white-light interferometers on the Hubble Space Telescope. Proper motions, spectral classifications and VJHKT2M and DDO51 photometry of the stars comprising the astrometric reference frames provide spectrophotometric estimates of reference star absolute parallaxes. Introducing these into our model as observations with error, we determine absolute parallaxes for each PNN. Weighted averaging with previous independent parallax measurements yields an average parallax precision, sigma (sub pi)/ pi = 5%. Derived distances are: d(sub NGC6853) = 405(exp +28 sub -25) pc, d(sub NGC7293) = 216(exp +14 sub -12) pc, d(sub Abell31) = 621(exp +91 sub -70) pc, and d(sub DeHt5) = 345(exp +19 sub -17) pc. These PNNi distances are all smaller than previously derived from spectroscopic analyses of the central stars. To obtain absolute magnitudes from these distances requires estimates of interstellar extinction. We average extinction measurements culled from the literature, from reddening based on PNNi intrinsic colors derived from model SEDs, and an assumption that each PNN experiences the same rate of extinction as a function of distance as do the reference stars nearest (in angular separation) to each central star. We also apply Lutz-Kelker bias corrections. The absolute magnitudes and effective temperatures permit estimates of PNNi radii through both the Stefan-Boltzmann relation and Eddington fluxes. Comparing absolute magnitudes with post-AGB models provides mass estimates. Masses cluster around 0.57 solar Mass, close to the peak of the white dwarf mass distribution. Adding a few more PNNi with well-determined distances and masses, we compare all the PNNi with cooler white dwarfs of similar mass, and confirm, as expected, that PNNi have larger radii than white dwarfs that have reached their final cooling tracks.

STARS↗

Study of the ψ 2 (3823) and χ c1 (3872) states in B + → (J/ψπ + π - )K + decays

The decays B + → J/ψπ + π – K + are studied using a data set corresponding to an integrated luminosity of 9 fb –1 collected with the LHCb detector in proton-proton collisions between 2011 and 2018. Precise measurements of the ratios of branching fractions with the intermediate ψ 2 (3823), χ c1 (3872) and ψ(2S) states are reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling Nanoscale Pore Size and Wall Composition in Polycarbonate Membranes via Atomic Layer Deposition and Sequential Infiltration Synthesis: Implications for High Water Permeance

Polymer membranes have a wide variety of applications, ranging from water treatment to energy storage. Many of these applications require precise control over the membrane porosity and surface chemistry. In this study, we explore the modification of isoporous polycarbonate (PC) track-etched membranes (PCTEs) by atomic layer deposition (ALD) and sequential infiltration synthesis (SIS) to tune the pore size and the pore wall surface chemistry. We first performed a detailed study of Al 2 O 3 ALD and SIS in PCTE using a variety of in situ and ex situ measurements. We discovered that short precursor exposure times are critical to achieve conformal Al 2 O 3 ALD in the PCTE nanopores, while longer precursor exposure times resulted in Al 2 O 3 SIS within the bulk of the PC leaving the membranes brittle. Next, we tuned the PCTE pore size via Al 2 O 3 ALD and studied its effect on the water contact angle and the water permeance. Here, we found that the membranes became more hydrophilic, and the permeance decreased with increasing ALD Al 2 O 3 cycles. Finally, we studied the effect of hydrophilic (SnO 2 )/hydrophobic (In 2 O 3 ) ALD metal oxide coatings on membrane properties. We found that the most hydrophilic SnO 2 showed the highest water flux and the least hydrophilic In 2 O 3 showed the lowest water flux through the PCTE membranes. Our results demonstrate that ALD is an effective method to tune the surface and transport properties of PCTE membranes, but care must be exercised to avoid SIS and bulk modification of the polymer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument

Abstract We describe the spectroscopic data processing pipeline of the Dark Energy Spectroscopic Instrument (DESI), which is conducting a redshift survey of about 40 million galaxies and quasars using a purpose-built instrument on the 4 m Mayall Telescope at Kitt Peak National Observatory. The main goal of DESI is to measure with unprecedented precision the expansion history of the universe with the baryon acoustic oscillation technique and the growth rate of structure with redshift space distortions. Ten spectrographs with three cameras each disperse the light from 5000 fibers onto 30 CCDs, covering the near-UV to near-infrared (3600–9800 Å) with a spectral resolution ranging from 2000 to 5000. The DESI data pipeline generates wavelength- and flux-calibrated spectra of all the targets, along with spectroscopic classifications and redshift measurements. Fully processed data from each night are typically available to the DESI collaboration the following morning. We give details about the pipeline’s algorithms, and provide performance results on the stability of the optics, the quality of the sky background subtraction, and the precision and accuracy of the instrumental calibration. This pipeline has been used to process the DESI Survey Validation data set, and has exceeded the project’s requirements for redshift performance, with high efficiency and a purity greater than 99% for all target classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of ${\mathrm{B}}_{\mathrm{s}}^0$ → J/ψπ + π – K + K – decays

The decays ${\mathrm{B}}_{\mathrm{s}}^0$ → J/ψπ + π – K + K – are studied using a data set corresponding to an integrated luminosity of 9 fb –1 , collected with the LHCb detector in proton-proton collisions at centre-of-mass energies of 7, 8 and 13 TeV. The decays ${\mathrm{B}}_{\mathrm{s}}^0$ → $\mathrm{J}/{ψ \mathrm{K}}^{\ast 0}{\overline{\mathrm{K}}}^{\ast 0}$ and ${\mathrm{B}}_{\mathrm{s}}^0$ → χ c1 (3872)K + K – , where the K + K – pair does not originate from a Φ meson, are observed for the first time. Precise measurements of the ratios of branching fractions between intermediate χ c1 (3872)Φ, $\mathrm{J}/{ψ \mathrm{K}}^{\ast 0}{\overline{\mathrm{K}}}^{\ast 0}$, ψ(2S)Φ and χ c1 (3872)K + K – states are reported. A structure, denoted as X(4740), is observed in the J/ψΦ mass spectrum and, assuming a Breit-Wigner parameterisation, its mass and width are determined to be ${\displaystyle \begin{array}{c}{m}_{\mathrm{X}(4740)}=4741\pm 6\pm 6\kern0.5em \mathrm{MeV}/{c}^2,\\ {}{\Gamma}_{\mathrm{X}(4740)}=53\pm 15\pm 11\kern0.5em \mathrm{MeV},\end{array}}$ where the first uncertainty is statistical and the second is systematic. In addition, the most precise single measurement of the mass of the ${\mathrm{B}}_{\mathrm{s}}^0$ meson is performed and gives a value of ${m}_{{\mathrm{B}}_{\mathrm{s}}^0}=5366.98\pm 0.07\pm 0.13\kern0.5em \mathrm{MeV}/{c}^2.$

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cross section measurements of the $e^+e^–$ → $D^{*+}D^{*–}$ and $e^+e^–$ → $D^{*+}D^{–}$ processes at center-of-mass energies from 4.085 to 4.600 GeV

The Born cross sections of the $e^+e^–$ → $D^{*+}D^{*–}$ and $e^+e^–$ → $D^{*+}D^{–}$ processes are measured using $e^+e^–$ collision data collected with the BESIII experiment at center-of-mass energies from 4.085 to 4.600 GeV, corresponding to an integrated luminosity of 15.7 fb -1 . The results are consistent with and more precise than the previous measurements by the Belle, Babar and CLEO collaborations. The measurements are essential for understanding the nature of vector charmonium and charmonium-like states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective medium approximation for the refractive index of stratified metal oxide composites synthesized by atomic layer deposition

Atomic layer deposition (ALD) is a unique method for synthesizing conformal layers with precise composition. It is especially useful for the synthesis of mixed metal oxides for functional materials. One application of interest is the use of ALD for tailoring the refractive index of coatings. In homogeneously distributed composites of metal oxides, the refractive properties can be approximated as the average of the indices of the components. This is known as an effective medium approximation (EMA) and can be used to design the macroscopic properties of composites. ALD produces layered, anisotropic films, so the validity of an EMA in describing these films is not clear. Here, we use optical simulations and experimental characterization of stratified composites of TiO 2 and Al 2 O 3 to study the application of an EMA to the transmission and reflection behavior of ALD-prepared mixed metal oxide thin films. We found that when the characteristic layer thickness is smaller than roughly 10 nm, the optical spectra of theoretical and experimental ALD films match the equivalent theoretical spectra for a material with a refractive index calculated from a simple, compositionally weighted EMA. Hence, this EMA could describe the transmission and reflectance spectra in ALD-derived TiO2–Al 2 O 3 nanolaminates when the films were sufficiently stratified even without thorough characterization of the real layers in the films. As a result, we demonstrated that ALD can be used to prepare effectively homogenous mixed metal oxide films with a predictable, tailorable refractive index of any value between those of the TiO 2 and Al 2 O 3 component materials.

42 ENGINEERING↗

Analysis of Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.

Abshire, James B.↗