Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power systems operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Further Examination of the Vibratory Loads Reduction Results from the NASA/ARMY/MIT Active Twist Rotor Test

The vibration reduction capabilities of a model rotor system utilizing controlled, strain-induced blade twisting are examined. The model rotor blades, which utilize piezoelectric active fiber composite actuators, were tested in the NASA Langley Transonic Dynamics Tunnel using open-loop control to determine the effect of active-twist on rotor vibratory loads. The results of this testing have been encouraging, and have demonstrated that active-twist rotor designs offer the potential for significant load reductions in future helicopter rotor systems. Active twist control was found to use less than 1% of the power necessary to operate the rotor system and had a pronounced effect on both rotating- and fixed-system loads, offering reductions in individual harmonic loads of up to 100%. A review of the vibration reduction results obtained is presented, which includes a limited set of comparisons with results generated using the second-generation version of the Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics (CAMRAD II) rotorcraft comprehensive analysis.

Wilbur, Matthew L.↗

An Open-Source Parallel EMT Simulation Framework

As the integration level of inverter-based resources (IBRs) increases, ensuring the reliable operation of the bulk power systems requires the use of electromagnetic transient (EMT) simulation tools to identify and mitigate system-wide stability risks. Conducting EMT studies for large-scale, IBR-rich grids, however, is challenging due to the inherent computational bottleneck caused by the underlying high-fidelity models and required small time steps. This paper introduces ParaEMT: an open-source, generic EMT simulation framework designed to accelerate simulations by leveraging advanced parallel computational technologies, such as high-performance computers. This paper presents a comprehensive exposition of ParaEMT, covering its modeling library, simulation strategy, framework structure, operational procedures, and auxiliary features, alongside its extensible parallel computational architecture. Notably, ParaEMT is a publicly accessible and modularized framework written in Python, thereby facilitating future development and the integration of new models and algorithms. The accuracy and efficiency of ParaEMT are demonstrated by rigorous validations via multiple case studies.

electromagnetic transient simulation↗

Microgravity effects on electrodeposition of metals and metal-cermet mixtures

An experimental system, designed to investigate the potential advantages of electrodeposition in microgravity, is being developed by the McDonnell Douglas Astronautics Company-Huntsville Division and the University of Alabama in Huntsville. It is intended to fly as an Orbiter payload when NASA resumes STS operations. The system will provide power, thermal conditioning, command and control for the production of electrodeposits; system performance data will be recorded for post-flight analysis. Plated metal surfaces will be created using simple electrolytic cells with pure metal electrodes immersed in aqueous electrolytic solutions. Crystalline structure and other properties will be analyzed to identify differences between samples produced in flight and those obtained from ground-based operations.

Maybee, George W.↗

Monitoring techniques for the X-29A aircraft's high-speed rotating power takeoff shaft

The experimental X-29A forward swept-wing aircraft has many unique and critical systems that require constant monitoring during ground or flight operation. One such system is the power takeoff shaft, which is the mechanical link between the engine and the aircraft-mounted accessory drive. The X-29A power takeoff shaft opertes in a range between 0 and 16,810 rpm, is longer than most jet engine power takeoff shafts, and is made of graphite epoxy material. Since the X-29A aircraft operates on a single engine, failure of the shaft during flight could lead to loss of the aircraft. The monitoring techniques and test methods used during power takeoff shaft ground and flight operations are discussed. Test data are presented in two case studies where monitoring and testing of the shaft dynamics proved instrumental in discovering and isolating X-29A power takeoff shaft problems. The first study concerns the installation of an unbalanced shaft. The effect of the unbalance on the shaft vibration data and the procedure used to correct the problem are discussed. The second study deals with the shaft exceeding the established vibration limits during flight. This case study found that the vibration of connected rotating machinery unbalances contributed to the excessive vibration level of the shaft. The procedures used to identify the contributions of other rotating machinery unbalances to the power takeoff shaft unbalance are discussed.

Voracek, David F.↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Helical Fins for Concentrated Solar Receivers: Design Optimization and Entropy Analysis

Concentrated solar power (CSP) with thermal energy storage (TES) has the potential to achieve grid parity. This can be realized by operating CSP systems at temperatures above 700 °C with high-efficiency sCO 2 power cycles. However, operating CSP systems at such temperatures poses several challenges, among which the design of solar receivers to accommodate increased thermal loads is critical. To this end, this work explores and optimizes various swirl-inducing internal fin designs for solar receiver tubes. These fin designs not only improve the thermal performance of receiver tubes but also levelize temperature unevenness caused by non-uniform thermal loading. In this work, the geometric parameters of the fin designs are optimized to maximize the Nusselt number with a constraint on the friction factor. This optimization, however, is computationally intensive, requiring hundreds of simulation calls to computational fluid dynamics (CFD) models. Here, to circumvent this problem, surrogate models are used to approximate the simulation outputs needed during the optimization. In addition, this study also examines the fin designs from an entropy generation perspective. To this end, the entropy contributions from thermal and viscous effects are quantitatively compared while varying the operational Reynolds number.

14 SOLAR ENERGY↗

Automotive Stirling engine system component review

The design and testing of the power and combustion control system for the basic Stirling engine, Mod II, are examined. The power control system is concerned with transparent operation, and the Mod II uses engine working gas pressure variation to control the power output of the engine. The main components of the power control system, the power control valve, the pump-down system, and the hydrogen stable system, are described. The combustion control system consists of a combustion air supply system and an air/fuel ratio control system, and the system is to maintain constant heater head temperature, and to maximize combustion efficiency and to minimize exhaust emissions.

Hindes, Chip↗

Solar Photovoltaics in Severe Weather: Cost Considerations for Storm Hardening PV Systems for Resilience

Solar photovoltaic (PV) power has many advantages as a resilient power source, including the ability to provide power after a natural disaster. While solar arrays often survive severe weather events, systems are occasionally compromised and left unable to provide power. For PV systems to act as resilient power providers, they must remain operational. Building a system that is more likely to survive a storm comes at a cost, though. Previous efforts have identified various system measures and practices that can increase the likelihood of a PV system surviving a severe weather event. But what is the cost premium for a storm hardened PV system? This report provides initial estimates for the up-front cost premiums for various methods of storm hardening PV systems.

14 SOLAR ENERGY↗

Modernizing to an AI-Ready Control System

The Accelerator Controls Operations Research Network (ACORN) project will modernize the accelerator control system and upgrade power supplies to enable future operations of the Fermilab Accelerator Complex with megawatt proton beams. By focusing on MLOps, ACORN enables full integration of AI into the control system to allow safe and reliable improvements to accelerator beam operations.

43 PARTICLE ACCELERATORS↗

Desal.jl

SAND2026-22942O Desal.jl is a Julia software package for lightweight reverse-osmosis desalination simulation. It supports static and dynamic operation of power-limited desalination systems without requiring optimization dependencies. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗

Hybrid deployable/erectable solar dynamic box truss system

The design of a hybrid deployable/erectable solar dynamic box truss power generation system for the initial operation capability (IOC) of the Space Shuttle is examined. An organic Rankine cycle heat engine for IOC solar power generation is studied. The design configuration is a simple parabolic concentration where the receiver is located in the focal plane with its aperture at the focal point. The relationship between concentrator size and collection efficiency is analyzed. The geometry of the deployable graphite/epoxy box truss ring and the reflective panels of the system are described. Mass properties and dynamic analyses are performed to evaluate the center of gravity location and moments of inertia characteristics of the energy conversion subsystem (ECS). The deployable/erectable truss is applicable for large IR space telescopes and center and offset fed ECSs.

Coyner, J. V., Jr.↗

What Is Power System Curtailment?

Curtailment is the intentional reduction of instantaneous power from non- dispatchable variable renewable energy (VRE) resources like wind and solar photovoltaics relative to what would naturally be available from the wind and the sun. This curtailed energy is the difference between the total available energy and actual production. This fact sheet provides a summary of curtailment in power systems and presents selected insights into specific ways in which curtailment is implemented by a selection of System Operators.

curtailment↗

Initial guidelines and estimates for a power system with inertial (flywheel) energy storage

The starting point for the assessment of a spacecraft power system utilizing inertial (flywheel) energy storage. Both general and specific guidelines are defined for the assessment of a modular flywheel system, operationally similar to but with significantly greater capability than the multimission modular spacecraft (MMS) power system. Goals for the flywheel system are defined in terms of efficiently train estimates and mass estimates for the system components. The inertial storage power system uses a 5 kw-hr flywheel storage component at 50 percent depth of discharge (DOD). It is capable of supporting an average load of 3 kw, including a peak load of 7.5 kw for 10 percent of the duty cycle, in low earth orbit operation. The specific power goal for the system is 10 w/kg, consisting of a 56w/kg (end of life) solar array, a 21.7 w-hr/kg (at 50 percent DOD) flywheel, and 43 w/kg power processing (conditioning, control and distribution).

Slifer, L. W., Jr.↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Manned space flight nuclear system safety. Volume 3: Reactor system preliminary nuclear safety analysis. Part 1: Reference Design Document (RDD)

The Reference Design Document, of the Preliminary Safety Analysis Report (PSAR) - Reactor System provides the basic design and operations data used in the nuclear safety analysis of the Rector Power Module as applied to a Space Base program. A description of the power module systems, facilities, launch vehicle and mission operations, as defined in NASA Phase A Space Base studies is included. Each of two Zirconium Hydride Reactor Brayton power modules provides 50 kWe for the nominal 50 man Space Base. The INT-21 is the prime launch vehicle. Resupply to the 500 km orbit over the ten year mission is provided by the Space Shuttle. At the end of the power module lifetime (nominally five years), a reactor disposal system is deployed for boost into a 990 km high altitude (long decay time) earth orbit.

Source record↗

Improved Cathode Structure for a Direct Methanol Fuel Cell

An improved cathode structure on a membrane/electrode assembly has been developed for a direct methanol fuel cell, in a continuing effort to realize practical power systems containing such fuel cells. This cathode structure is intended particularly to afford better cell performance at a low airflow rate. A membrane/electrode assembly of the type for which the improved cathode structure was developed (see Figure 1) is fabricated in a process that includes brush painting and spray coating of catalyst layers onto a polymer-electrolyte membrane and onto gas-diffusion backings that also act as current collectors. The aforementioned layers are then dried and hot-pressed together. When completed, the membrane/electrode assembly contains (1) an anode containing a fine metal black of Pt/Ru alloy, (2) a membrane made of Nafion 117 or equivalent (a perfluorosulfonic acid-based hydrophilic, proton-conducting ion-exchange polymer), (3) a cathode structure (in the present case, the improved cathode structure described below), and (4) the electrically conductive gas-diffusion backing layers, which are made of Toray 060(TradeMark)(or equivalent) carbon paper containing between 5 and 6 weight percent of poly(tetrafluoroethylene). The need for an improved cathode structure arises for the following reasons: In the design and operation of a fuel-cell power system, the airflow rate is a critical parameter that determines the overall efficiency, cell voltage, and power density. It is desirable to operate at a low airflow rate in order to obtain thermal and water balance and to minimize the size and mass of the system. The performances of membrane/electrode assemblies of prior design are limited at low airflow rates. Methanol crossover increases the required airflow rate. Hence, one way to reduce the required airflow rate is to reduce the effect of methanol crossover. Improvement of the cathode structure - in particular, addition of hydrophobic particles to the cathode - has been demonstrated to mitigate the effects of crossover and decrease the airflow required.

Valdez, Thomas↗

Reserve and energy scarcity pricing in United States power markets: A comparative review of principles and practices

Here, errors in forecasting load and renewable-based generation in restructured power systems mean that independent system operators (ISOs) must procure sufficient operating reserves to keep the real-time operation of the system reliable and secure. But when procured reserves turn out to be insufficient in real-time due to the lack of resource capacity or ramp capability, operators often set higher prices for reserves and energy to encourage more supply, and to motivate consumers to decrease usage or shift it to other times. This procedure, which is called scarcity or shortage pricing, is a core feature of U.S. electricity markets. It is receiving increased attention from market designers and stakeholders because scarcity will become more important for spot price formation in the future with the increased penetration of zero-marginal cost renewables, and the shrinking role of fuel costs in setting prices. Scarcity pricing is implemented in various ways by different ISOs. These differences have practical implications for the level of prices and incentives for investment, operations, and demand modification. In this paper, general approaches and specific calculation procedures for reserve and energy scarcity pricing practices and calculations across the seven ISO-based U.S. power markets are reviewed and compared. A consistent terminology is used to facilitate the comparison. Current scarcity pricing practices are grouped into three approaches: (1) imposing an adder after the spot market is run; (2) including stepwise demand curves within market clearing procedures for non-contingency reserve products (e.g., the novel flexiramp product), which tends to yield longer right tails for energy scarcity premium curves; and (3) having stepwise demand curves for traditional contingency reserve products only, which results in shorter right tails in energy scarcity curves. A generic numerical example is presented to highlight the large practical differences among the reserve scarcity pricing approaches and specific implementations. To further investigate factors that contribute the most to demand curves differences among ISOs, a sensitivity analysis is performed. This analysis shows that the largest source of differences among the curves is the scarcity prices assumed in the case of severe scarcity, while the number of steps used and whether flexiramp is considered also yields important differences in scarcity prices. As renewable penetration increases, it will become increasingly crucial to employ administrative demand curves so that spot prices more effectively motivate supply and demand adjustments exactly when and where they are needed. This study shows that the different assumptions yield very different scarcity premiums for reserves and energy, and are likely to provide divergent incentives for resources to respond to shortages. It is concluded that to promote market efficiency, a reserve shortage demand curve should have at least three features: inclusion of the marginal value of reserve products at each shortage level, consideration of the magnitude and probability of supply contingencies, and avoidance of abrupt price discontinuities that can cause excessively volatile market outcomes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗