Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase change”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Phase lags in Cygnus X-1

Coronae of hot electrons are ubiquitous features in models of the inner regions of accreting black holes and nonmagnetic neutron stars. The scattering optical depth of these coronae inferred from observations is often tau approximately 3, so the energy spectrum of the disk in these regions is likely masked by the spectrum of upscattered photons in the corona and some of the disk properties are thus obscured. Observations of the dependence on not available with the energy spectrum. In our picture, the disk emission is modeled as a photon source injected into a Comptonizing corona; Comptonization may also occur in the disk, but for our purposes the disk emission is simply an input to the corona. We show that, contrary to some claims, the functional dependence of lag on Fourier frequency emerges intact from transit through the corona, modulo a multiplicative factor (which may in principle be negative, so that a phase lag can be changed to a phase lead), even if the properties of the corona vary with time. We also show that any frequency dependence of the lag due to variation in the corona itself is only second order in the amplitude of the variation, and cannot exceed the transit time approximately ms of the corona; thus, the lags of up to 0.1 s seen in several black hole candidates come from lags in the emission from the disk. Finally, we predict that plots of the time lag versus Fourier frequency in black hole candidates should have a 'shelf' of constant lag equal to the coronal lag (approximately 1 ms), with the constant being proportional to In (E(sub 2)/E(sub 1)) for the lag between energies E(sub 2) and E(sub 1). The lack of such a shelf in current observations of several galactic black hole candidates constraints the radii of the coronae to be R less than or approximately = 10(exp 8) tau cm.

Miller, M. Coleman↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗

Analysis of the Amplitude Response of a Two-Point and a Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the relative amplitude response of each instrument to a traveling shockwave generated by a laser spark in air. The first FLDI instrument generated two slightly-separated measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated a measurement line that was oriented parallel to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along the line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement line is oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along the line. Numerical computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Brett F. Bathel↗

Analysis of the Amplitude Response of a Two-Point and a Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the relative amplitude response of each instrument to a traveling shockwave generated by a laser spark in air. The first FLDI instrument generated two slightly-separated measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated a measurement line that was oriented parallel to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along the line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement line is oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along the line. Numerical computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Interferometry↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model is validated against self-pressurization experiment performed in the K-site flightweight hydrogen storage tank at NASA Glenn Research Center. Laminar and turbulent simulations together with conjugated heat transfer analysis are performed. Effects of turbulence, as well as tank wall conduction are presented and discussed. Predicted tank pressures and fluid temperatures are compared with the experimental data at two different heat loads for validating the CFD model.

phase change↗

Infrared photometry and polarimetry of Cygnus X-3

We present photometry and linear polarimetry of Cygnus X-3 at K (2.2 micrometers) obtained over a 5 yr period. Photometry and polarimetry at J, H, and K of nearby field stars is also presented. From an analysis of these data we find: (1) Using the x-ray ephemeris of Kitamoto et al. (ApJ, 384, 263 (1992), including the first and second derivatives of the period, the leading edge of the decline to minimum in the quiescent K light curve has not changed in phase since 1974. The duration of the minimum in the light curve has changed significantly between different epochs, becoming much broader in 1993 than it was previously. (2) In addition to an interstellar polarization component, it is likely Cyg X-3 has an intrinsic polarization component that is variable. The variations in the polarization do not show any diagnostic pattern with orbital phase. A crude analysis of the polarization suggests the intrinsic polarization of Cyg X-3 has a mean position angle of approximately 12 deg, nearly the same as the direction of the expanding radio lobes. This is consistent with circumstellar electrons scattering in an equatorial disk that is perpendicular to the lobe axis. (3) The mean position angle for the interstellar polarization in the direction of Cyg X-3 is 150 deg. This is nearly perpendicular to the axis of interstellar radio scattering seen in the extended (Very Long Baseline Inteferometry (VLBI) images. Since the position angle of interstellar polarization is the same as the projected magnetic field direction, this suggests the interstellar (not circumstellar) scattering must be taking place perpendicular to the interstellar magnetic field lines. (4) Cyg X-3 was observed at K during a flare on 1992 September 30 with a temporal resolution of 6 s. The flaring had rise and fall times of approximately 50 s with peak intensities up to 80 mJy. The flux between individual flare events never dropped to quiescent levels for the duration of our observations (approximately 2000 s).

Jones, Terry Jay↗

Role of valence electrons in phase transformation kinetics of thallium and its dilute alloys

The kinetics of the phase transformation of thallium and its dilute alloys were investigated using XRD and calorimetry. Pure thallium exhibits a beta(bcc) to alpha(hcp) phase transformation on cooling at 508 K. With alloying additions, the crystal structure for each phase does not change, although the size of the unit cell increases. The enthalpy and the temperature of phase transformation of each alloy have been determined. The chemical free energy change associated with the phase transformation of each alloy was calculated. The valence electrons make an outstanding contribution to the chemical free energy change required for the phase change.

Ahmed, R.↗

Interferometric apparatus for ultra-high precision displacement measurement

A high-precision heterodyne interferometer measures relative displacement by creating a thermally-insensitive system generally not subject to polarization leakage. By using first and second light beams separated by a small frequency difference (.DELTA.f), beams of light at the first frequency (f.sub.0) are reflected by co-axial mirrors, the first mirror of which has a central aperture through which the light is transmitted to and reflected by the second mirror. Prior to detection, the light beams from the two mirrors are combined with light of the second and slightly different frequency. The combined light beams are separated according to the light from the mirrors. The change in phase (.DELTA..phi.) with respect to the two signals is proportional to the change in distance of Fiducial B by a factor of wavelength (.lambda.) divided by 4.pi. (.DELTA.L=.lambda..DELTA..phi.1/(4.pi.)). In a second embodiment, a polarizing beam splitting system can be used.

Zhao, Feng↗

Atmospheric perturbation and control of a shuttle/tethered satellite

A simplified model of the strong atmospheric perturbation of a small satellite attached to the orbiter by a long, rigid tether predicts undesirable uncontrolled libration motions similar to those from sophisticated models. The simplified model is used to compare performance limitations of two simple control systems that rely only on tether tension for three-dimensional control. Because the effects on libration of both the changing kinematic and atmospheric drag torques caused by changing length are largely predictable, the controller that models these changes has substantially better performance. In particular, the altitude variation of the tethered satellite above an oblate earth can be controlled substantially better with a controller that uses a length command adapted to these predictable changes than one that only reacts to tension changes. Also, small amplitude out-of-plane librations, that are coupled only to second-order with changing length, can be damped substantially faster by the controller that periodically commands properly phased length changes than by the controller that only reacts to the second-order changes in tension.

Spencer, T. M.↗

An assessment of thermal, wind, and planetary wave changes in the middle and lower atmosphere due to 11-year UV flux variations

Hines (1974) speculated that solar-induced modifications of the middle and upper atmosphere may alter the transmissivity of the stratosphere to upwardly propagating atmospheric waves. It was suggested that subsequent constructive or destructive interference may result in a change of phase or amplitude of these waves in the troposphere leading to weather or climate changes. The present investigation has the objective to bring together both radiative transfer and planetary wave studies in an effort to assess specifically whether Hines mechanism can be initiated by the solar ultraviolet flux variability assumed to be associated with the 11-year solar cycle. The obtained results suggest that the presently studied mechanism, which links solar-induced zonal wind changes in the stratosphere and mesosphere to planetary wave changes in the troposphere, is not strong enough to cause substantive changes in the troposphere.

Callis, L. B.↗

Fiber-Optic Sensor Would Monitor Growth of Polymer Film

A proposed optoelectronic sensor system would measure the increase in thickness of a film of parylene (a thermoplastic polymer made from para-xylene) during growth of the film in a vapor deposition process. By enabling real-time monitoring of film thickness, the system would make it possible to identify process conditions favorable for growth and to tailor the final thickness of the film with greater precision than is now possible. The heart of the sensor would be a pair of fiber-optic Fabry-Perot interferometers, depicted schematically in the figure. (In principle, a single such interferometer would suffice. The proposal calls for the use of two interferometers for protective redundancy and increased accuracy.) Each interferometer would include a light source, a fiber-optic coupler, and photodetectors in a control box outside the deposition chamber. A single-mode optical fiber for each interferometer would run from inside the control box to a fused-silica faceplate in a sensor head. The sensory tips of the optical fibers would be polished flush with the free surface of the faceplate. In preparation for use, the sensor head would be mounted with a hermetic seal in a feed-through port in the deposition chamber, such that free face of the faceplate and the sensory tips of the optical fibers would be exposed to the deposition environment. During operation, light would travel along each optical fiber from the control box to the sensor head. A small portion of the light would be reflected toward the control box from the end face of each fiber. Once growth of the parylene film started, a small portion of the light would also be reflected toward the control box from the outer surface of the film. In the control box, the two reflected portions of the light beam would interfere in one of the photodetectors. The difference between the phases of the interfering reflected portions of the light beam would vary in proportion to the increasing thickness of the film and the known index of refraction of the film, causing the photodetector reading to vary in proportion to a known sinusoidal function of film thickness. Electronic means of monitoring this variation and the corresponding variation in phase and thickness are well established in the art of interferometry. Hence, by tracking the cumulative change in phase difference from the beginning of deposition, one could track the growing thickness of the film to within a small fraction of a wavelength of light.

Beamesderfer, Michael↗

Application of Phase Shifted, Laser Feedback Interferometry to Fluid Physics

We have combined the principles of phase-shifting interferometry (PSI) and laser-feedback interferometry (LFI) to produce a new instrument that can measure both optical path length (OPL) changes and discern sample reflectivity variations. In LFI, coherent feedback of the incident light either reflected directly from a surface or reflected after transmission through a region of interest will modulate the output intensity of the laser. LFI can yield a high signal-to-noise ratio even for low reflectivity samples. By combining PSI and LFI, we have produced a robust instrument, based upon a HeNe laser, with high dynamic range that can be used to measure either static (dc) or oscillatory changes along the optical path. As with other forms of interferometry, large changes in OPL require phase unwrapping. Conversely, small phase changes are limited by the fraction of a fringe that can be measured. We introduce the phase shifts with an electro-optic modulator (EOM) and use either the Carre or Hariharan algorithms to determine the phase and visibility. We have determined the accuracy and precision of our technique by measuring both the bending of a cantilevered piezoelectric bimorph and linear ramps to the EOM. Using PSI, sub-nanometer displacements can be measured. We have combined our interferometer with a commercial microscope and scanning piezoelectric stage and have measured the variation in OPL and visibility for drops of PDMS (silicone oil) on coated single crystal silicon. Our measurement of the static contact angle agrees with the value of 68 deg stated in the literature.

Ovryn, Ben↗

The Effect of Solution Thermal History on Chicken Egg White Lysozyme Nucleation

Proteins are highly flexible molecules and often exhibit defined conformational changes in response to changes in the ambient temperature. Chicken egg white lysozyme has been previously shown to undergo an apparent structural change when warmed above the tetragonal/orthorhombic phase transition temperature. This is reflected by a change in the habit of the tetragonal and orthorhombic crystals so formed. In this study we show that possible conformational changes induced by heating are stable and apparently non- reversible by simple cooling. Exposure of protein solutions to temperatures above the phase change transition temperature, before combining with precipitant solution to begin crystallization, reduces final crystal numbers. Protein that is briefly warmed to 37 C, then cooled shows no sign of reversal to the unheated nucleation behavior even after storage for 4 weeks at 4 C. The change in nucleation behavior of tetragonal lysozyme crystals, attributed to a structural shift, occurs faster the greater the exposure to temperature above the equi-solubility point for the two phases. Heating for 2 h at 48 C reduces crystal numbers by 20 fold in comparison to the same solution heated for the same time at 30 C. Thermal treatment of solutions is therefore a possible tool to reduce crystal numbers and increase crystal size. The effects of a protein's previous thermal history are now shown to be a potentially critical factor in subsequent macromolecule crystal nucleation and growth studies.

Burke, Michael W.↗

The Effect of Solution Thermal History on Chicken Egg White Lysozyme Nucleation

Proteins are highly flexible molecules and often exhibit defined conformational changes in response to changes in the ambient temperature. Chicken egg white lysozyme has been previously shown to undergo an apparent structural change when warmed above the tetragonal/orthorhombic phase transition temperature. This is reflected by a change in the habit of the tetragonal and orthorhombic crystals so formed. In this study, we show that possible conformational changes induced by heating are stable and apparently non-reversible by simple cooling. Exposure of protein solutions to temperatures above the phase change transition temperature, before combining with precipitant solution to begin crystallization, reduces final crystal numbers. Protein that is briefly warmed to 37 C, then cooled shows no sign of reversal to the unheated nucleation behavior even after storage for four weeks at 4 C. The change in nucleation behavior of tetragonal lysozyme crystals, attributed to a structural shift, occurs faster the greater the exposure to temperature above the equi-solubility point for the two phases. Heating for 2 hours at 48 C reduces crystal numbers by 20 fold in comparison to the same solution heated for the same time at 30 C. Thermal treatment of solutions is therefore a possible tool to reduce crystal numbers and increase crystal size. The effects of a protein's previous thermal history are now shown to be a potentially critical factor in subsequent macromolecule crystal nucleation and growth studies.

Burke, Michael W.↗

System and method for tuning adjusting the central frequency of a laser while maintaining frequency stabilization to an external reference

A method and system for stabilizing a laser to a frequency reference with an adjustable offset. The method locks a sideband signal generated by passing an incoming laser beam through the phase modulator to a frequency reference, and adjusts a carrier frequency relative to the locked sideband signal by changing a phase modulation frequency input to the phase modulator. The sideband signal can be a single sideband (SSB), dual sideband (DSB), or an electronic sideband (ESB) signal. Two separate electro-optic modulators can produce the DSB signal. The two electro-optic modulators can be a broadband modulator and a resonant modulator. With a DSB signal, the method can introduce two sinusoidal phase modulations at the phase modulator. With ESB signals, the method can further drive the optical phase modulator with an electrical signal with nominal frequency OMEGA(sub 1) that is phase modulated at a frequency OMEGA(sub 2)

Livas, Jeffrey↗

Hydrogen at high pressure

Results of recent studies of the high-pressure states of hydrogen using diamond anvils are summarized. Problems associated with the study of hydrogen under megabar pressures are briefly examined. Attention is then given to new data on the physical state of solid hydrogen, the 1.5-megabar phase transition, changes in the electronic configuration of hydrogen at high pressure, and directions of further research on the high-pressure phases of hydrogen.

Mao, Ho-Kwang↗