Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Thermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Development of Wireless Subsurface Microsensors for Health Monitoring of Thermal Protection Systems

Low cost access to space is a primary goal for both NASA and the U.S. aerospace industry. Integrated subsystem health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles (RLVS) in order to reduce life cycle costs, increase safety margins and improve mission reliability. A number of efforts are underway to use existing and emerging technologies to establish new methods for vehicle health monitoring on operational vehicles as well as X-vehicles. This paper summarizes a joint effort between several NASA centers and industry partners to develop rapid wireless diagnostic tools for failure management and long-term TPS performance monitoring of thermal protection systems (TPS) on future RLVS. An embedded wireless microsensor suite is being designed to allow rapid subsurface TPS health monitoring and damage assessment. This sensor suite will consist of both passive overlimit sensors and sensors for continuous parameter monitoring in flight. The on-board diagnostic system can be used to radio in maintenance requirements before landing and the data could also be used to assist in design validation for X-vehicles. For a 3rd generation vehicle, wireless diagnostics should be at a stage of technical development that will allow use for intelligent feedback systems for guidance and navigation control applications and can also serve as feedback for TPS that can intelligently adapt to its environment.

Pallix, Joan↗

Cloud Tolerance of Remote-Sensing Technologies to Measure Land Surface Temperature

Conventional methods to estimate land surface temperature (LST) from space rely on the thermal infrared(TIR) spectral window and is limited to cloud-free scenes. To also provide LST estimates during periods with clouds, a new method was developed to estimate LST based on passive microwave(MW) observations. The MW-LST product is informed by six polar-orbiting satellites to create a global record with up to eight observations per day for each 0.25resolution grid box. For days with sufficient observations, a continuous diurnal temperature cycle (DTC) was fitted. The main characteristics of the DTC were scaled to match those of a geostationary TIR-LST product. This paper tests the cloud tolerance of the MW-LST product. In particular, we demonstrate its stable performance with respect to flux tower observation sites (four in Europe and nine in the United States), over a range of cloudiness conditions up to heavily overcast skies. The results show that TIR based LST has slightly better performance than MW-LST for clear-sky observations but suffers an increasing negative bias as cloud cover increases. This negative bias is caused by incomplete masking of cloud-covered areas within the TIR scene that affects many applications of TIR-LST. In contrast, for MW-LST we find no direct impact of clouds on its accuracy and bias. MW-LST can therefore be used to improve TIR cloud screening. Moreover, the ability to provide LST estimates for cloud-covered surfaces can help expand current clear-sky-only satellite retrieval products to all-weather applications.

polar-orbiting↗

Design of 1 kW Simplified Stirling Controller Using Capacitor-Based Power Factor Correction

Free-piston Stirling convertors hold potential for efficient, reliable thermal to electric power conversion, provided they are paired with a robust controller. This paper outlines work underway on a system-level optimization of a kW controller. Using simplified control and passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is improved through incorporating wide-bandgap gallium nitride (GaN) switches, and PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling space power concepts.

Stirling↗

Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power

The innovation consists of a thermodynamic system for extracting in situ oxygen vapor from lunar regolith using a solar photovoltaic power source in a reactor, a method for thermally insulating the reactor, a method for protecting the reactor internal components from oxidation by the extracted oxygen, a method for removing unwanted chemical species produced in the reactor from the oxygen vapor, a method for passively storing the oxygen, and a method for releasing high-purity oxygen from storage for lunar use. Lunar oxygen exists in various types of minerals, mostly silicates. The energy required to extract the oxygen from the minerals is 30 to 60 MJ/kg O. Using simple heating, the extraction rate depends on temperature. The minimum temperature is approximately 2,500 K, which is at the upper end of available oven temperatures. The oxygen is released from storage in a purified state, as needed, especially if for human consumption. This method extracts oxygen from regolith by treating the problem as a closed batch cycle system. The innovation works equally well in Earth or Lunar gravity fields, at low partial pressure of oxygen, and makes use of in situ regolith for system insulation. The innovation extracts oxygen from lunar regolith using a method similar to vacuum pyrolysis, but with hydrogen cover gas added stoichiometrically to react with the oxygen as it is produced by radiatively heating regolith to 2,500 K. The hydrogen flows over and through the heating element (HE), protecting it from released oxygen. The H2 O2 heat of reaction is regeneratively recovered to assist the heating process. Lunar regolith is loaded into a large-diameter, low-height pancake reactor powered by photovoltaic cells. The reactor lid contains a 2,500 K HE that radiates downward onto the regolith to heat it and extract oxygen, and is shielded above by a multi-layer tungsten radiation shield. Hydrogen cover gas percolates through the perforated tungsten shielding and HE, preventing oxidation of the shielding and HE, and reacting with the oxygen to form water vapor. The water vapor is filtered through solid regolith to remove unwanted extraction byproducts, and then condensed to a liquid state and stored at 300 to 325 K. Conversion to usable oxygen is achieved by pumping liquid water into a high-pressure electrolyzer, storing the gaseous oxygen at high pressure for use, and diverting the hydrogen back to the reactor or to storage. The results from this design effort show that this oxygen-generating concept can be developed in an efficient system with low specific mass. Advantages include use of regolith as an oxygen source, filter, and thermal insulator. The system can be tested in Earth gravity and can be expected to operate similarly in lunar gravity. The system is scalable, either by increasing the power level and output of a standard module, or by employing multiple modules.

Burton, rodney↗

Investigation of mounting discrete chip components for hybrid microelectronic applications.

In the assembly of hybrid microcircuits, passive and active discrete chip components are attached by epoxy cements and by solders. This study was initiated to determine the integrity of such attachments. Alumina substrates were subjected to a group of thermal and mechanical test environments defined by test methods in MIL-STD-883. Lot samples of substrates with assembly variations were subjected to separately applied testing and to serial testing. These test methods were applied sequentially to the same lot of substrates. Epoxy cements were generally satisfactory with respect to separate tests, although sequential tests severely degraded epoxy bond strengths of all types. Bond strengths to unglazed substrates were slightly superior to those of the same components on glazed types. Solder joints were vulnerable to catastrophic failure in several environments, especially temperature cycling and thermal shock. Vibration and impact shock also produced solder joint failures.

Caruso, S. V.↗

Space Station thermal control during on-orbit assembly

This paper summarizes the Space Station program requirements for the Thermal Control System (TCS), and outlines the capabilities of the TCS for each assembly configuration. The TCS architecture for the completed assembly configuration is described, consisting of an active TCS (ATCS) and a passive TCS (PTCS). The four ATCS subsystems are described, including the two-phase ammonia central ATCS, photovoltaic power module, attached payload accommodation equipment and the single-phase water internal ATCS.

Bilardo, Vincent J., Jr.↗

Second LDEF Post-Retrieval Symposium interim results of experiment A0034

Thermal control coatings and contaminant collector mirrors were exposed on the leading and trailing edge modules of Long Duration Exposure Facility (LDEF) experiment A0034 to provide a basis of comparison for investigating the role of atomic oxygen in the stimulation of volatile outgassing products. The exposure of identical thermal coatings on both the leading and trailing edges of the LDEF and the additional modified exposure of identical coatings under glass windows and metallic covers in each of the flight modules provided multiple combinations of space environmental exposure to the coatings and the contaminant collector mirrors. Investigations were made to evaluate the effects of the natural space and the induced environments on the thermal coatings and the collector mirrors to differentiate the sources of observed material degradation. Two identical flight units were fabricated for the LDEF mission, each of which included twenty-five thermal control coatings mounted in isolated compartments, each with an adjacent contaminant collector mirror mounted on the wall. The covers of the flight units included apertures for each compartment, exposing the thermal coatings directly to the space environment. Six of these compartments were sealed with ultraviolet-grade transmitting quartz windows and four other compartments were sealed with aluminum covers. One module of this passive LDEF experiment, occupying one-sixth of a full tray, was mounted in Tray C9 (leading edge), while the other identical module was mounted in Tray C3 (trailing edge).

Linton, Roger C.↗

Satellite Gravimetry Applied to Drought Monitoring

Near-surface wetness conditions change rapidly with the weather, which limits their usefulness as drought indicators. Deeper stores of water, including root-zone soil wetness and groundwater, portend longer-term weather trends and climate variations, thus they are well suited for quantifying droughts. However, the existing in situ networks for monitoring these variables suffer from significant discontinuities (short records and spatial undersampling), as well as the inherent human and mechanical errors associated with the soil moisture and groundwater observation. Remote sensing is a promising alternative, but standard remote sensors, which measure various wavelengths of light emitted or reflected from Earth's surface and atmosphere, can only directly detect wetness conditions within the first few centimeters of the land s surface. Such sensors include the Advanced Microwave Scanning Radiometer - Earth Observing System (AMSR-E) C-band passive microwave measurement system on the National Aeronautic and Space Administration's (NASA) Aqua satellite, and the combined active and passive L-band microwave system currently under development for NASA's planned Soil Moisture Active Passive (SMAP) satellite mission. These instruments are sensitive to water as deep as the top 2 cm and 5 cm of the soil column, respectively, with the specific depth depending on vegetation cover. Thermal infrared (TIR) imaging has been used to infer water stored in the full root zone, with limitations: auxiliary information including soil grain size is required, the TIR temperature versus soil water content curve becomes flat as wetness increases, and dense vegetation and cloud cover impede measurement. Numerical models of land surface hydrology are another potential solution, but the quality of output from such models is limited by errors in the input data and tradeoffs between model realism and computational efficiency. This chapter is divided into eight sections, the next of which describes the theory behind satellite gravimetry. Following that is a summary of the GRACE mission and how hydrological information is gleaned from its gravity products. The fourth section provides examples of hydrological science enabled by GRACE. The fifth and sixth sections list the challenging aspects of GRACE derived hydrology data and how they are being overcome, including the use of data assimilation. The seventh section describes recent progress in applying GRACE for drought monitoring, including the development of new soil moisture and drought indicator products, and that is followed by a discussion of future prospects in satellite gravimetry based drought monitoring.

Rodell, Matthew↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

UO 2 -liquid metal suspension fuel concept for enhanced passive safety of LWRs: A heat pipe case study

This work proposes a novel fuel concept for use in light-water type reactors (LWRs): UO 2 particles suspended in a low-melting-point liquid metal (LM). This new fuel form offers lower energy density and higher thermal conductivity, thus enhancing the fuel’s thermal performance compared to sintered UO 2 pellets. Two candidate alloys for the LM are proposed based on previous studies into accident-tolerant fuels: Bi-Pb-Sn and Pb-Sn. Ten research questions are provided to guide future development of this fuel. A simple heat pipe model was constructed by coupling a reactor physics code to a heat transport code and other physics modules. Scoping calculations were performed on this model core as a preliminary investigation into five of the research questions. A fuel with 13 wt% UO 2 was shown to maintain a steady-state peak coolant channel wall temperature below 400 °C, and maintain criticality via self-regulating reactivity feedback. Shortcomings of the present model are discussed in this work, along with proposed future model improvements and fuel development. The appendix provides an example of a reactor concept that could be developed to utilize this fuel, but more modeling and experimental work are needed before a full reactor concept can be developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of space exposure of some epoxy matrix composites on their thermal expansion and mechanical properties (A0138-8)

This experiment has three objectives. The first and main objective is to detect a possible variation in the coefficient of thermal expansion of composite samples during a 1-year exposure to the near-Earth orbital environment. A second objective is to detect a possible change in the mechanical integrity of composite products, both simple elements and honeycomb sandwich assemblies. A third objective is to compare the behavior of two epoxy resins commonly used in space structural production. The experimental approach is to passively expose samples of epoxy matrix composite materials to the space environment and to compare preflight and postflight measurements of mechanical properties. The experiment will be located in one of the three FRECOPA (French cooperative payload) boxes in a 12-in.-deep peripheral tray that contains nine other experiments from France. The FRECOPA box will protect the samples from contamination during the launch and reentry phases of the mission. The coefficients of thermal expansion are measured on Earth before and after space exposure.

Elberg, R.↗

Benchmark Modeling and Simulation of the FFTF LOFWOS Test #13 Using SAM

The Fast Flux Test Facility (FFTF) was a 400 MW thermal powered, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. In July 1986, a series of unprotected Loss of Flow Without Scram (LOFWOS) transients were performed in FFTF as part of the Passive Safety Testing (PST) program. The LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors left off, has been chosen as a benchmark case by IAEA to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of sodium fast reactor passive safety in an IAEA Coordinated Research Project (CRP), launched in October 2018. The System Analysis Module (SAM) is an advanced and modern system analysis tool under development at Argonne National Laboratory for advanced non-LWR safety analysis. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. To participate the IAEA CRP and enhance the SAM validation base for advanced reactor transient safety analysis, benchmark simulations of the FFTF LOFWOS Test #13 are performed using the SAM code. In this first phase of the validation effort, the thermal-hydraulic behavior of the reactor system is the focus and the reactor kinetics is not considered in the SAM FFTF model. Instead, the results of Argonne’s neutronics calculations are directly used, including the power shape of the active core region and the power history during the transient. The simulation results of FFTF at steady state agreed well with the measured data from the test. During the transient, reasonably good agreement were also obtained. Future work to improve the model will focus on introducing the reactivity predictions into the model, as well as better understanding or resolving the current discrepancies with the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delamination Depth Imaging for Quasi-Static and Fatigue Load Testing Using Passive Thermography

Passive thermography is used to monitor small increases in temperature resulting from delamination damage formation in composite hat-stiffened panels during both quasi-static and fatigue loading. It has been observed that rapid damage formation produces heating. This is composed of two heat generation components. The first component is an instantaneous response due to an irreversible thermoelastic strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This produces a transient rise in temperature as the heat diffuses to the surface. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is fitted to the data pixel by pixel, to produce imagery of the damage depth. The results are compared to ultrasonic and X-ray CT data.

Passive thermography↗

Depolarization self-compensation in high-power lasers enabled by a mid-cavity quartz rotator

Depolarization from thermal stress remains a major limitation in high-average-power laser amplifiers, often addressed by complex, costly active methods or by using magneto-optical effects to restore the polarization. We demonstrate a passive polarization self-compensation technique using a quartz rotator in a relay-imaged, multi-pass amplifier geometry. A detailed theoretical framework is presented and validated experimentally, showing a 47 × reduction in depolarized light in a relay-imaged 4-pass cavity. This approach employs a high-damage-threshold, reciprocal material and avoids the use of polarizers or active controls, thereby simplifying system design and reducing costs. Scalability is discussed for realistic inertial fusion energy driver designs, including effectiveness for broadband lasers and thick gain media.

Batysta, František [Lawrence Livermore National La↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary design of the Space Station internal thermal control system

The baseline preliminary design configuration of the Internal Thermal Control system (ITCS) of the U.S. Space Station pressurized elements (i.e., the Habitation and U.S. Laboratory modules, pressurized logistics carrier, and resources nodes) is defined. The ITCS is composed of both active and passive components. The subsystems which comprise the ITCS are identified and their functional descriptions are provided. The significant trades and analyses, which were performed during Phase B (i.e., the preliminary design phase) that resulted in the design described herein, are discussed. The ITCS interfaces with the station's central Heat Rejection and Transport System (HRTS), other systems, and externally attached pressurized payloads are described. Requirements on the ITCS with regard to redundancy and experiment support are also addressed.

Herrin, Mark T.↗