Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Design principles of tandem cascade photoelectrochemical devices

Cascade photoelectrocatalysis (PEC) is a possible method to improve the selectivity of solar-driven CO 2 reduction (CO 2 R). This concept can be realized by coupling different CO 2 R catalysts to different subcells in a multijunction photovoltaic (PV) stack. Efficient implementation will require careful tuning of the photocurrents and design of the photovoltages provided by the subcells to the CO 2 R catalysts in such a way as to facilitate the target reaction. Here, we outline the design principles of the tandem PEC approach using two-step conversion of CO 2 to ethylene in aqueous electrolyte, via a CO intermediate, as a model system. To perform this reaction, the first coupled PV-catalyst component should provide 4 electrons to reduce 2 molecules of CO 2 to CO; the second component should provide 8 electrons to reduce 2 CO molecules to C 2 H 4 . Based on known CO 2 R catalysts, the overpotential required to produce CO can be less than that required to reduce it to ethylene, creating the opportunity for improved efficiency. Cascade PEC can be realized in a three-terminal tandem (3TT) configuration using III–V-semiconductor based subcells coupled to Au (produces CO intermediate) and Cu (converts CO to ethylene). The current to each catalyst can be controlled by the area of the subcell exposed to the electrolyte, and the photovoltage is determined by the materials selected and device configuration. Operating conditions are found by simulating the coupled system using the open-source circuit simulator SPICE (Simulation Program with Integrated Circuits Emphasis). We identify conditions under which a 3TT configuration can have a higher solar to chemical conversion efficiency compared to a two-terminal two-junction tandem (2T 2J) with the same absorbers and a Cu catalyst only. We also show that 3TT PEC devices can be less sensitive to variations in catalyst activity compared to 2T devices. Lastly, we discuss the applications of cascade PEC to CO 2 reduction, using different intermediates, and to other chemical networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Grid Modeling and Hosting Capacity Analysis

An interface with the OpenDSS distribution grid simulator, facilitating users in calibrating and validating models. Additionally, three distinct tools have been developed: PV Hosting Capacity: This tool allows users to determine the additional amount of photovoltaic (PV) generation that can be integrated into the system without breaching operational constraints. EV Hosting Capacity: This tool focuses on identifying the capacity for incorporating extra electric vehicle (EV) load into the system without surpassing operational limitations. Project Impact Analysis Tool: This tool is designed to assess and report all potential grid violations associated with a specific project, providing valuable insights into its impact on the distribution grid.

Poudel, Shiva↗

The 2021 Blind PVPMC Modeling Intercomparison

This document provides the instructions for participating in the 2021 blind photovoltaic (PV) modeling intercomparison organized by the PV Performance Modeling Collaborative (PVPMC). It describes the system configurations, metadata, and other information necessary for the modeling exercise. The practical details of the validation datasets are also described. The datasets were published online in open access in April 2023, after completing the analysis of the results.

14 SOLAR ENERGY↗

Planning for Equitable Solar Deployment with Electric Cooperatives

The goal of the study was to understand how electric cooperatives can design equitable solar photovoltaic (PV) projects consistent with the goals of their organizations. To understand the possibilities for equitable solar deployment, the project team carefully defined cross-subsidy by delving into the multi-level structure of electric cooperatives. Understanding that utilities and analysts apply different cost-categorization perspectives was key to developing a transparent analytic model that traces the economic value flows of new solar PV projects across the tiers of a cooperative system.

14 SOLAR ENERGY↗

Hydropower Advantages over Batteries in Energy Storage of Off-Grid Systems: A Case Study

Microgrids are decentralized power production systems, where the energy production and consumption are very close to each other. Microgrids generally exploit renewable energy sources, encountering a problem of storage, as the power production from solar and wind is intermittent. This research presents a new integrated methodology and discusses a comparison of batteries and pumped storage hydropower (PSH) as energy storage systems with the integration of wind and solar PV energy sources, which are the major upcoming technologies in the renewable energy sector. We implemented the simulator and optimizer model (HOMER), which develops energy availability usage to obtain optimized renewable energy integration in the microgrid, showing its economic added value. Two scenarios are run with this model—one considers batteries as an energy storage technology and the other considers PSH—in order to obtain the best economic and technical results for the analyzed microgrid. The economic analysis showed a lower net present cost (NPC) and levelized cost of energy (LCOE) for the microgrid with PSH. The results showed that the microgrid with the storage of PSH was economical, with an NPC of 45.8 M€ and an LCOE of 0.379 €/kWh, in comparison with the scenario with batteries, which had an NPC of 95.2 M€ and an LCOE of 0.786 €/kWh. The role of storage was understood by differentiating the data into different seasons, using a Python model. Furthermore, a sensitivity analysis was conducted by varying the capital cost multiplier of solar PV and wind turbines to obtain the best optimal economic solutions.

Guruprasad, Prajwal↗

Solar photovoltaic waterless soiling monitoring systems and methods

A system for evaluation of soiling of solar photovoltaic (PV) modules may comprise a first pair of solar PV modules exposed to the elements, a second pair of solar PV modules enclosed within a protective housing having a glass cover; a component coupling the glass cover to the protective housing. The component may be configured to displace the glass cover for a limited period of time to temporarily expose the second pair of solar PV modules to the atmospheric elements.

14 SOLAR ENERGY↗

Reliability of tandem solar cells and modules: what's next?

Hybrid tandem photovoltaic (PV) technology development has gained momentum in the last few years. This has been motivated by a need to push module efficiencies beyond what is theoretically capable with single-junction technologies to further accelerate total global PV deployment. Significant advances have been made with multiple material systems achieving tandem efficiencies over 30% in the last decade. All of the highest record efficiencies have been from laboratory-scale devices, with areas of 1 cm2 or less. Interestingly, there are multiple material combinations and terminal configurations that have demonstrated promising results. Despite these high laboratory efficiencies, reasonable service lifetimes (a useful operating lifetime of at least 25 years) are needed for tandems to compete with the levelized cost of energy (LCOE) of traditional single junction PV technologies. Existing commercial Si PV products have demonstrated performance in the field with an average of less than 1% relative annual degradation in module and system performance, and many manufacturers now provide 30 year warranties on their products.

14 SOLAR ENERGY↗

Distributed PV Hosting Capacity Evaluation Considering Equitable PV Accommodation

Distributed photovoltaic (DPV) hosting capacity is widely used by distribution system operators to evaluate how much DPV the distribution networks can accommodate without violating operational constraints. If the proliferation of DPV deployment is appropriately managed, it offers an excellent opportunity to mitigate the energy inequity issue in electric grids. Hosting capacity improvement plans that neglect energy equity can exacerbate unequal DPV access. To consider energy equity in distribution network planning to enhance DPV accommodation, hosting capacity evaluations should be improved to consider equity constraints endogenously. This paper proposes a DPV hosting capacity evaluation method that considers equitable DPV access among sub-regions of a distribution feeder partitioned by socioeconomic indicators, such as income level. The results demonstrate that considering equity in DPV hosting capacity evaluations can provide a valuable reference in the equitable energy transition. This work provides guidance for future distribution network upgrade planning for equitable DPV deployment.

distributed PV↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Life cycle analysis of a hydrogen production system based on solid oxide electrolysis cells integrated with different energy and wastewater sources

Hydrogen production via water electrolysis is a promising and evolving technology. The solid oxide electrolysis cell (SOEC) is one of the several technologies for this purpose. They are alternatives to the traditional hydrogen production from fossil fuels to enhance global energy decarbonization. However, in the bid for sustainability and a green economy, these technologies are not free from causing some environmental burdens. Using life cycle assessment (LCA), the greenhouse gas emission and degree of environmental impacts by these technologies can be identified and measured throughout their lifespan. This study addresses how to quantify these CO 2 emission impacts for an electrolytic system with different energy sources. The LCA of a novel integrated hydrogen production SOEC system with energy from solar photovoltaic and bituminous powerplant is performed using simaPro, the leading global LCA solution software. Measuring the environmental impact of the electrolytic operation in terms of weight, the bituminous powerplant poses damage which is, on average 700% more than solar PV. The thermal-to-hydrogen efficiency of the SOEC system is 56%, and a probable 28% reduction in carbon footprint with heat integration. The steam generation and the manufacturing of the SOEC have a very high environmental impact potential on the system. Here, we recommend LCA and net energy analysis is carried out for every new hydrogen technology and adequate comparison to enhance sustainable and green economy.

08 HYDROGEN↗

sCO 2 Brayton System Market Analysis

Supercritical CO 2 Brayton cycle systems (sCO 2 ) offer potential benefits over traditional steam plants. The changing economics of the electricity sector favors solar photovoltaic (PV), wind, and natural gas combined cycle (NGCC). Ultimately, the ability of sCO 2 systems to compete depends on the economics and ability to offer additional benefits to the market, such as the ability for dry cooling and their compact size. Updated results show that the projected LCOE for Brayton systems in the 100 to 300 MWe size range are between ${$}$44.8 and ${$}$56.1/MWh (4.48 and 5.61 cents/kWh). This report presents screening tools for assessing the potential market size and concludes that while at these LCOE estimates sCO 2 systems can compete directly against NGCC, there are many hurdles to commercialization, including the need to demonstrate long-term operations at low-cost and ability to quickly ramp for integration with intermittent resources. Additional customer discovery is necessary to fully understand the ability of this technology to solve customer problems that other technologies cannot.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A First Investigation of Agriculture Sector Perspectives on the Opportunities and Barriers for Agrivoltaics

Agrivoltaic systems are a strategic and innovative approach to combine solar photovoltaic (PV)-based renewable energy generation with agricultural production. Recognizing the fundamental importance of farmer adoption in the successful diffusion of the agrivoltaic innovation, this study investigates agriculture sector experts’ perceptions on the opportunities and barriers to dual land-use systems. Using in-depth, semistructured interviews, this study conducts a first study to identify challenges to farmer adoption of agrivoltaics and address them by responding to societal concerns. Results indicate that participants see potential benefits for themselves in combined solar and agriculture technology. The identified barriers to adoption of agrivoltaics, however, include: (i) desired certainty of long-term land productivity, (ii) market potential, (iii) just compensation and (iv) a need for predesigned system flexibility to accommodate different scales, types of operations, and changing farming practices. The identified concerns in this study can be used to refine the technology to increase adoption among farmers and to translate the potential of agrivoltaics to address the competition for land between solar PV and agriculture into changes in solar siting, farming practice, and land-use decision-making.

14 SOLAR ENERGY↗

Is Clean Hydrogen Production a Good Fit for Questa? Intermediate Feasibility Study Results

NREL conducted a feasibility study for a clean hydrogen production facility that would be located in Questa, New Mexico. This slide deck presents the history of the coalition of stakeholders that received NREL technical assistance through the Department of Energy's Communities Leading Energy Action Program. It describes how hydrogen is generated and its end uses. It describes two conceptual applications explored in the feasibility analysis, a grid-tied power generation and long-term storage application and a heavy-duty vehicle fueling application. The presentation details the configuration of these to applications in the Questa pilot facility, including system components, required inputs (water, electricity, and land for pv generation), and outputs in kilograms of hydrogen, megawatt hours of power delivered, and hours of vehicle hours of operation. The presentation addresses key concerns raised by groups engaged through a public outreach process, including safety, health, and environmental issues; water use; visual impacts; and costs and alternatives.

heavy-duty vehicle fueling↗

Enhanced deep neural networks with transfer learning for distribution LMP considering load and PV uncertainties

As the flexibility of generation and demand increases in distribution systems, the residential loads are emerging as a promising means to participate in demand response and the transactive energy market. Market pricing is an instrumental mechanism for the distribution system operator to exploit the full potential of the flexible resources. The distribution locational marginal price (DLMP) can be used to guide the residential load consumption. This type of market signal helps the distribution system operator to optimize the scheduling of all resources while satisfying related network constraints through a day-ahead market. However, solving the optimization problem for large-scale systems can be computationally expensive. To address the scalability and practicability limitations of the DLMP framework, a learning-based approach is proposed in this paper to complement the day-ahead distribution market framework. Here, the proposed approach combines long short-term memory and transfer learning to develop deep neural network that can capture the spatial–temporal correlation of the input data. The model can determine the optimal DLMP for each node in a distribution system without the system parameters required to formulate the optimization problem. Testing results on IEEE 33-bus and 123-bus systems show that the proposed approach can generate a comparable DLMP against the optimization solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗