Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POINT SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A CATALOG OF MIPSGAL DISK AND RING SOURCES

We present a catalog of 416 extended, resolved, disk and ringlike objects as detected in the MIPSGAL 24 {mu}m survey of the Galactic plane. This catalog is the result of a search in the MIPSGAL image data for generally circularly symmetric, extended 'bubbles' without prior knowledge or expectation of their physical nature. Most of the objects have no extended counterpart at 8 {mu}m or 70 {mu}m, with less than 20% detections at each wavelength. For the 54 objects with central point sources, the sources are nearly always seen in all Infrared Array Camera bands. About 70 objects (16%) have been previously identified, with another 35 listed as Infrared Astronomical Satellite sources. Among the identified objects, those with central sources are mostly listed as emission-line stars, but with other source types including supernova remnants (SNRs), luminous blue variables, and planetary nebulae (PNe). The 57 identified objects (of 362) without central sources are nearly all PNe ({approx}90%), which suggests that a large fraction of the 300+ unidentified objects in this category are also PNe. These identifications suggest that this is primarily a catalog of evolved stars. Also included in the catalog are two filamentary objects that are almost certainly SNRs, and 10 unusual compact extended objects discovered in the search. Two of these show remarkable spiral structure at both 8 {mu}m and 24 {mu}m. These are likely background galaxies previously hidden by the intervening Galactic plane.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating CXOU J163802.6–471358: A new pulsar wind nebula in the norma region?

We present the first analysis of the extended source CXOU J163802.6–471358, which was discovered serendipitously during the Chandra X-ray survey of the Norma region of the Galactic spiral arms. The X-ray source exhibits a cometary appearance with a point source and an extended tail region. The complete source spectrum is fitted well with an absorbed power law model and jointly fitting the Chandra spectrum of the full source with one obtained from an archived XMM-Newton observation results in best fit parameters N {sub H} =1.5{sub −0.5}{sup +0.7}×10{sup 23} cm{sup −2} and Γ=1.1{sub −0.6}{sup +0.7} (90% confidence uncertainties). The unabsorbed luminosity of the full source is then L{sub X}∼4.8×10{sup 33}d{sub 10}{sup 2} erg s{sup –1} with d {sub 10} = d/10 kpc, where a distance of 10 kpc is a lower bound inferred from the large column density. The radio counterpart found for the source using data from the Molonglo Galactic Plane Survey epoch-2 shows an elongated tail offset from the X-ray emission. No infrared counterpart was found. The results are consistent with the source being a previously unknown pulsar driving a bow shock through the ambient medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Nucleation and growth kinetics for intercalated islands during deposition on layered materials with isolated pointlike surface defects

Theory and stochastic lattice-gas modeling is developed for the formation of intercalated metal islands in the gallery between the top layer and the underlying layer at the surface of layered materials. Our model for this process involves deposition of atoms, some fraction of which then enter the gallery through well-separated pointlike defects in the top layer. Subsequently, these atoms diffuse within the subsurface gallery leading to nucleation and growth of intercalated islands nearby the defect point source. For the case of a single point defect, continuum diffusion equation analysis provides insight into the nucleation kinetics. However, complementary tailored lattice-gas modeling produces a more comprehensive and quantitative characterization. We analyze the large spread in nucleation times and positions relative to the defect for the first nucleated island. We also consider the formation of subsequent islands and the evolution of island growth shapes. The shapes reflect in part our natural adoption of a hexagonal close-packed island structure. As a result, motivation and support for the model is provided by scanning tunneling microscopy observations of the formation of intercalated metal islands in highly-ordered pyrolytic graphite at higher temperatures.

36 MATERIALS SCIENCE↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

OLED Lighting in the Offices of DeJoy, Knauf & Blood, LLP (Final Report)

The new offices of DeJoy, Knauf, & Blood, LLP in Rochester NY feature all solid state lighting, with eight different types of organic light-emitting diode luminaires. This was a chance to see and document the performance of an architectural space using OLEDs, in terms of efficacy, color, flicker, light levels, visual comfort, energy use, dimming, and appearance. Although the efficacy ranges of the luminaires are still well below the performance of LEDs, the installation demonstrates a solid state light source that is planar rather than a point source of light. Reported user acceptance was very high. Four luminaires were photometered by an independent laboratory so that future performance could be tracked.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical simulation of one-dimensional heat transfer in composite bodies with phase change

A numerical simulation was developed to investigate the one dimensional heat transfer occurring in a system composed of a layered aircraft blade having an ice deposit on its surface. The finite difference representation of the heat conduction equations was done using the Crank-Nicolson implicit finite difference formulation. The simulation considers uniform or time dependent heat sources, from heaters which can be either point sources or of finite thickness. For the ice water phase change, a numerical method which approximates the latent heat effect by a large heat capacity over a small temperature interval was applied. The simulation describes the temperature profiles within the various layers of the de-icer pad, as well as the movement of the ice water interface. The simulation could also be used to predict the one dimensional temperature profiles in any composite slab having different boundary conditions.

Dewitt, K. J.↗

An X-ray study of M51 (NGC 5194) and its companion (NGC 5195)

Observations of NGC 5194/95 with the Einstein HRI show a very strong nuclear X-ray source, surrounded by a diffuse flux, three point sources, and the companion. The diffuse flux, which correlates well with the radio continuum, is likely to originate from the disk population with an age of approximately 2.1 billion yrs. The large luminosity from the nuclear source, together with optical and radio observations, shows that it belongs to the low luminosity active nuclei, thus extending this class to luminosities of less than about 10 to the 40th erg/s.

Palumbo, G. G. C.↗

IRAS observations of BL Lac objects

IRAS data was analyzed for 35 BL Lac objects selected from a complete 5 GHz radio sample, using the coadded survey database. The detection rate is 50% with more than 40% detected in more than one band. This compares with only 15% of these sources that are included in the IRAS Point Source Catalog. High luminosity BL Lac objects generally have smooth energy spectra over four or five decades in frequency, consistent with incoherent synchrotron emission from 1 cm to 1 micron. However, many low luminosity BL Lac objects have discontinuous spectra, with a large range in the spectral index at IRAS wavelengths. For BL Lacs with a total luminosity of less than 10 to the 44th power ergs/-s, most of the far infrared energy probably originates from dust heated near the galaxy nucleus. The energy budget shows that the majority of the power per unit bandwidth emerges in the infrared (1 to 100 microns).

Impey, C.↗

Discovery of X-ray and Optical/Infrared Counterpart of XTE J1906+09

We present the Chandra localization of the transient X-ray source XTE J1906+09 and the discovery of optical and infrared counterparts. We analysed the archival Chandra ACIS-I observations of the region and determined the precise source position, that is 8$\arcmin$ away from position determined with the RXTE/PCA. We performed optical observations of the I field around the new location and identified a coincident ~ optical source (R=18.7). There exists an infrared point source in the Two Micron All Sky Survey catalogue with J=15.2, H=14.2 and K=13.5 whose location is also coincident with our Chandra and optical astrometry solutions. We additionally comment on the likely Be/X-ray binary nature of the system.

Gogus, Ersin↗

Suzaku observation of the Fermi cygnus cocoon: The search for a signature of young cosmic-ray electrons

The origin of Galactic cosmic rays remains unconfirmed, but promising candidates for their sources are found in star-forming regions. We report a series of X-ray observations, with Suzaku, toward the nearby star-forming region of Cygnus X. They aim at comparing diffuse X-ray emissions on and off the γ-ray cocoon of hard cosmic rays revealed by the Fermi Large Area Telescope. After excluding point sources and small-scale structures and subtracting the non-X-ray and cosmic X-ray backgrounds, the 2–10 keV X-ray intensity distribution is found to monotonically decrease with increasing Galactic latitude. This indicates that most of the extended emission detected by Suzaku originates from the Galactic ridge. In two observations, we derive upper limits of 3.4×10{sup −8} and 1.3×10{sup −8} erg s{sup −1} cm{sup −2} sr{sup −1} to X-ray emission in the 2–10 keV range from the γ-ray cocoon. These limits exclude the presence of cosmic-ray electrons with energies above about 50 TeV at a flux level capable of explaining the γ-ray spectrum. They are consistent with the emission cut-off observed near a TeV in γ-rays. The properties of the Galactic-ridge and local diffuse X-rays are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

THE TOP 10 SPITZER YOUNG STELLAR OBJECTS IN 30 DORADUS

The most luminous Spitzer point sources in the 30 Doradus triggered second generation are investigated coherently in the 3-8 {mu}m region. Remarkable diversity and complexity in their natures are revealed. Some are also among the brightest JHK sources, while others are not. Several of them are multiple when examined at higher angular resolutions with Hubble Space Telescope NICMOS and WFPC2/WFC3 as available, or with VISTA/VMC otherwise. One is a dusty compact H II region near the far northwestern edge of the complex, containing a half-dozen bright I-band sources. Three others appear closely associated with luminous WN stars and causal connections are suggested. Some are in the heads of dust pillars oriented toward R136, as previously discussed from the NICMOS data. One resides in a compact cluster of much fainter sources, while another appears monolithic at the highest resolutions. Surprisingly, one is the brighter of the two extended ''mystery spots'' associated with Knot 2 of Walborn et al. Masses are derived from young stellar object models for unresolved sources and lie in the 10-30 M{sub Sun} range. Further analysis of the IR sources in this unique region will advance understanding of triggered massive star formation, perhaps in some unexpected and unprecedented ways.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FAR-INFRARED-RADIO CORRELATION AT HIGH REDSHIFTS: PHYSICAL CONSIDERATIONS AND PROSPECTS FOR THE SQUARE KILOMETER ARRAY

I present a predictive analysis for the behavior of the far-infrared (FIR)-radio correlation as a function of redshift in light of the deep radio continuum surveys which may become possible using the Square Kilometer Array (SKA). To keep a fixed ratio between the FIR and predominantly non-thermal radio continuum emission of a normal star-forming galaxy, whose cosmic-ray electrons typically lose most of their energy to synchrotron radiation and inverse Compton (IC) scattering, requires a nearly constant ratio between galaxy magnetic field and radiation field energy densities. While the additional term of IC losses off of the cosmic microwave background (CMB) is negligible in the local universe, the rapid increase in the strength of the CMB energy density (i.e., approx(1 + z){sup 4}) suggests that evolution in the FIR-radio correlation should occur with infrared (IR; 8-1000 mum)/radio ratios increasing with redshift. This signature should be especially apparent once beyond z approx 3 where the magnetic field of a normal star-forming galaxy must be approx50 muG to save the FIR-radio correlation. At present, observations do not show such a trend with redshift; z approx 6 radio-quiet quasars appear to lie on the local FIR-radio correlation while a sample of z approx 4.4 and z approx 2.2 submillimeter galaxies exhibit ratios that are a factor of approx2.5 below the canonical value. I also derive a 5sigma point-source sensitivity goal of approx20 nJy (i.e., sigma{sub rms} approx 4 nJy) requiring that the SKA specified sensitivity be A{sub eff}/T{sub sys} approx 15,000 m{sup 2} K{sup -1}; achieving this sensitivity should enable the detection of galaxies forming stars at a rate of approx>25 M{sub sun} yr{sup -1}, such as typical luminous infrared galaxies (i.e., L{sub IR} approx> 10{sup 11} L{sub sun}), at all redshifts if present. By taking advantage of the fact that the non-thermal component of a galaxy's radio continuum emission will be quickly suppressed by IC losses off of the CMB, leaving only the thermal (free-free) component, I argue that deep radio continuum surveys at frequencies approx>10 GHz may prove to be the best probe for characterizing the high-z star formation history of the universe unbiased by dust.

79 ASTRONOMY AND ASTROPHYSICS↗

Far ultraviolet astronomy using the FAUST telescope

The Far Ultraviolet Space Telescope (FAUST) a compact, wide field-of-view, far ultraviolet instrument designed for astronomical observations of extended and point sources is discussed. The design and application of the instrument are described. The prime objective is to observe faint astronomical sources with sensitivities higher than previously available. Scientific programs will include: (1) a search for ultraviolet stars which are predicted to exist at the stage of evolution prior to the final death of a star; (2) observations of galaxies and quasars; and (3) joint programs with other Spacelab 1 experiments. The secondary objective is to verify the suitability of the Spacelab as a platform for far ultraviolet astronomy: data will be provided on the ultraviolet background levels due to astronomical, terrestrial, and spacecraft generated sources; the levels of contaminants which affect ultraviolet instruments; and the capability of the Orbiter for stable pointing at celestial sources for useful periods of time.

Bowyer, C. S.↗

The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources

Purpose: The goal of this work is to compare D{sub m,m} (radiation transported in medium; dose scored in medium) and D{sub w,m} (radiation transported in medium; dose scored in water) obtained from Monte Carlo (MC) simulations for a subset of human tissues of interest in low energy photon brachytherapy. Using low dose rate seeds and an electronic brachytherapy source (EBS), the authors quantify the large cavity theory conversion factors required. The authors also assess whether applying large cavity theory utilizing the sources' initial photon spectra and average photon energy induces errors related to spatial spectral variations. First, ideal spherical geometries were investigated, followed by clinical brachytherapy LDR seed implants for breast and prostate cancer patients. Methods: Two types of dose calculations are performed with the GEANT4 MC code. (1) For several human tissues, dose profiles are obtained in spherical geometries centered on four types of low energy brachytherapy sources: {sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds, as well as an EBS operating at 50 kV. Ratios of D{sub w,m} over D{sub m,m} are evaluated in the 0-6 cm range. In addition to mean tissue composition, compositions corresponding to one standard deviation from the mean are also studied. (2) Four clinical breast (using {sup 103}Pd) and prostate (using {sup 125}I) brachytherapy seed implants are considered. MC dose calculations are performed based on postimplant CT scans using prostate and breast tissue compositions. PTV D{sub 90} values are compared for D{sub w,m} and D{sub m,m}. Results: (1) Differences (D{sub w,m}/D{sub m,m}-1) of -3% to 70% are observed for the investigated tissues. For a given tissue, D{sub w,m}/D{sub m,m} is similar for all sources within 4% and does not vary more than 2% with distance due to very moderate spectral shifts. Variations of tissue composition about the assumed mean composition influence the conversion factors up to 38%. (2) The ratio of D{sub 90(w,m)} over D{sub 90(m,m)} for clinical implants matches D{sub w,m}/D{sub m,m} at 1 cm from the single point sources. Conclusions: Given the small variation with distance, using conversion factors based on the emitted photon spectrum (or its mean energy) of a given source introduces minimal error. The large differences observed between scoring schemes underline the need for guidelines on choice of media for dose reporting. Providing such guidelines is beyond the scope of this work.

60 APPLIED LIFE SCIENCES↗

CORRELATIONS BETWEEN ULTRAHIGH ENERGY COSMIC RAYS AND INFRARED-LUMINOUS GALAXIES

We confirm the ultrahigh energy cosmic ray (UHECR) horizon established by the Pierre Auger Observatory using the heterogeneous Veron-Cetty-Veron (VCV) catalog of active galactic nuclei by performing a redshift-angle-IR luminosity scan using point-source catalog with redshift (PSCz) galaxies having infrared luminosity greater than 10{sup 10} L{sub sun}. The strongest correlation-for z < 0.016, {psi} = 2.{sup 0}1, and L{sub ir} {>=} 10{sup 10.5} L{sub sun}-arises in fewer than 0.3% of scans with isotropic source directions. When we apply a penalty for using the UHECR energy threshold that was tuned to maximize the correlation with VCV, the significance degrades to 1.1%. Since the PSCz catalog is complete and volume-limited for these parameters, this suggests that the UHECR horizon discovered by the Pierre Auger Observatory is not an artifact of the incompleteness and other idiosyncrasies of the VCV catalog. The strength of the correlation between UHECRs and the nearby highest-IR-luminosity PSCz galaxies is stronger than in about 90% of trials with scrambled luminosity assignments for the PSCz galaxies. If confirmed by future data, this result would indicate that the sources of UHECRs are more strongly associated with luminous IR galaxies than with ordinary, lower IR luminosity galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Organ S values and effective doses for family members exposed to adult patients following I-131 treatment: A Monte Carlo simulation study

Purpose: To calculate organ S values (mGy/Bq-s) and effective doses per time-integrated activity (mSv/Bq-s) for pediatric and adult family members exposed to an adult male or female patient treated with I-131 using a series of hybrid computational phantoms coupled with a Monte Carlo radiation transport technique.Methods: A series of pediatric and adult hybrid computational phantoms were employed in the study. Three different exposure scenarios were considered: (1) standing face-to-face exposures between an adult patient and pediatric or adult family phantoms at five different separation distances; (2) an adult female patient holding her newborn child, and (3) a 1-yr-old child standing on the lap of an adult female patient. For the adult patient model, two different thyroid-related diseases were considered: hyperthyroidism and differentiated thyroid cancer (DTC) with corresponding internal distributions of {sup 131}I. A general purpose Monte Carlo code, MCNPX v2.7, was used to perform the Monte Carlo radiation transport.Results: The S values show a strong dependency on age and organ location within the family phantoms at short distances. The S values and effective dose per time-integrated activity from the adult female patient phantom are relatively high at shorter distances and to younger family phantoms. At a distance of 1 m, effective doses per time-integrated activity are lower than those values based on the NRC (Nuclear Regulatory Commission) by a factor of 2 for both adult male and female patient phantoms. The S values to target organs from the hyperthyroid-patient source distribution strongly depend on the height of the exposed family phantom, so that their values rapidly decrease with decreasing height of the family phantom. Active marrow of the 10-yr-old phantom shows the highest S values among family phantoms for the DTC-patient source distribution. In the exposure scenario of mother and baby, S values and effective doses per time-integrated activity to the newborn and 1-yr-old phantoms for a hyperthyroid-patient source are higher than values for a DTC-patient source.Conclusions: The authors performed realistic assessments of {sup 131}I organ S values and effective dose per time-integrated activity from adult patients treated for hyperthyroidism and DTC to family members. In addition, the authors’ studies consider Monte Carlo simulated “mother and baby/child” exposure scenarios for the first time. Based on these results, the authors reconfirm the strong conservatism underlying the point source method recommended by the US NRC. The authors recommend that various factors such as the type of the patient's disease, the age of family members, and the distance/posture between the patient and family members must be carefully considered to provide realistic dose estimates for patient-to-family exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Small Radioactive Source in a Large Media - Localization by Multi-detector Measurement. The Case of a Lung Counter

Considerable errors in the determination of radioactive contamination in lungs can be induced if there is no homogeneous distribution, as assumed for the calibration. Modern lung counter systems use several detectors, and the count rate ratios of the detectors can be used for localization of the radioactive contamination, enabling the use of correction algorithms. This greatly reduces the errors in the determination of the activity. Further reduction of the errors can be obtained by simultaneous analysis of several gamma lines (if several energies are emitted by the radioisotope), and by optimizing the number and location of the detectors. This presentation deals with the case of a point source of natural uranium in human lungs.

07 ISOTOPE AND RADIATION SOURCES↗