Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PH VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Molecular Structure and Transport Dynamics in Perfluoro Sulfonyl Imide Membranes

We report a detailed and comprehensive analysis of the nanostructure, transport dynamics of water and hydronium and water percolation in hydrated perfluoro sulfonyl imides (PFSI), a polymer considered for proton transport in PEM fuel cells, using classical molecular dynamics simulations. The dynamical changes are related to the changes in the membrane nanostructure. Water network percolation threshold, the level at which a consistent spanning water network starts to develop in the membrane, lies between hydration level (λ) 6 and 7. The higher acidity of the sulfonyl imide acid group of PFSI compared to Nafion reported in our earlier ab initio study, translates into more free hydronium ions at low hydration levels. Nevertheless, the calculated diffusion coefficients of the H3O+ ions and H2O molecules as a function the hydration level were observed to be almost the same as that of Nafion, indicating similar conductivity and consistent with the experimental observations. This research was performed in part using the Molecular Science Computing Facility in the William R. Wiley Environmental Molecular Sciences Laboratory, a U.S. Department of Energy (DOE) national scientific user facility located at the Pacific Northwest National Laboratory (PNNL). This work was supported by the US Department of Energy Basic Energy Sciences' Chemical Sciences, Geosciences & Biosciences Division. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

30 DIRECT ENERGY CONVERSION↗

Electron phonon coupling in Ni-based binary alloys with application to displacement cascade modeling

Energy transfer between lattice atoms and electrons is an important channel of energy dissipation during displacement cascade evolution in irradiated materials. On the assumption of small atomic displacements, the intensity of this transfer is controlled by the strength of electron–phonon (el–ph) coupling. The el–ph coupling in concentrated Ni-based alloys was calculated using electronic structure results obtained within the coherent potential approximation. It was found that Ni 0.5 Fe 0.5 , Ni 0.5 Co 0.5 and Ni 0.5 Pd 0.5 are ordered ferromagnetically, whereas Ni 0.5 Cr 0.5 is nonmagnetic. Since the magnetism in these alloys has a Stoner-type origin, the magnetic ordering is accompanied by a decrease of electronic density of states at the Fermi level, which in turn reduces the el–ph coupling. Thus, the el–ph coupling values for all alloys are approximately 50% smaller in the magnetic state than for the same alloy in a nonmagnetic state. As the temperature increases, the calculated coupling initially increases. After passing the Curie temperature, the coupling decreases. The rate of decrease is controlled by the shape of the density of states above the Fermi level. Introducing a two-temperature model based on these parameters in 10 keV molecular dynamics cascade simulation increases defect production by 10–20% in the alloys under consideration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FIRST INTEGRAL OBSERVATIONS OF V404 CYGNI DURING THE 2015 OUTBURST: SPECTRAL BEHAVIOR IN THE 20–650 KeV ENERGY RANGE

In 2015 June, the source V404 Cygni (= GS2023+38) underwent an extraordinary outburst. We present the results obtained during the first revolution dedicated to this target by the INTEGRAL mission and focus on the spectral behavior in the hard X-ray domain, using both SPI and IBIS instruments. The source exhibits extreme variability and reaches fluxes of several tens of Crab. However, the emission between 20 and 650 keV can be understood in terms of two main components, varying on all the observable timescales, similar to what is observed in the persistent black hole system Cyg X-1. The low-energy component (up to ∼200 keV) presents a rather unusual shape, probably due to the intrinsic source variability. Nonetheless, a satisfactory description is obtained with a Comptonization model, if an unusually hot population of seed photons (kT{sub 0} ∼ 7 keV) is introduced. Above this first component, a clear excess extending up to 400–600 keV leads us to investigate a scenario where an additional (cutoff) power law could correspond to the contribution of the jet synchrotron emission, as proposed in Cyg X-1. A search for an annihilation feature did not provide any firm detection, with an upper limit of 2 × 10{sup −4} ph cm{sup −2} s{sup −1} (2σ) for a narrow line centered at 511 keV, on the averaged obtained spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Sequestration of CO{sub 2} in Mixtures of Caustic Byproduct and Saline Waste Water

A series of tests were conducted to investigate a novel reaction concept designed to achieve neutralization of mixtures of acidic oil field produced brine and caustic industrial byproducts while sequestering substantial quantities of anthropogenic carbon dioxide (CO{sub 2}) in a mixed-flow reactor. Experiments were conducted to determine the CO{sub 2}-bearing capacity of reactive mixtures of brine from the Oriskany Sandstone Formation with three caustic industrial byproducts: flue gas desulfurization (FGD) spray dryer ash, Class C fly ash subbituminous coal combustion byproduct, and bauxite residue slurry from the alumina production process. Reactions were conducted in a closed, well-mixed (1,500 rpm) reactor with gas composed of 29.46% vol./vol. CO{sub 2} balanced by nitrogen gas fed at a rate of 300 mL/min. Reactions were carried out at ambient conditions. Results show linear relationships between caustic byproduct addition and CO{sub 2}-bearing capacity, with relatively small impact of brine addition as compared to deionized water addition. FGD spray dryer ash/brine mixtures exhibited higher CO{sub 2} reactivity than those using Class C fly ash (0.759 moles CO{sub 2}, at 23.6% solids by weight and 0.036 moles CO{sub 2} at 23.3% solids by weight, respectively). Bauxite residue exhibited moderate capacities in mixtures with higher percent solids (0.335 moles CO{sub 2} in 40% solids bauxite residue slurry). Carbonation capacity of caustic byproduct/acidic brine mixtures was shown to increase linearly with respect to percent caustic byproduct addition, but enhanced mineral carbonate precipitation resulting from synergistic reaction of brine cations with increased dissolved carbonate species was not observed in the short term.

01 COAL, LIGNITE, AND PEAT↗

Analysis of crystallization data in the Protein Data Bank

In a large-scale study using data from the Protein Data Bank, some of the many reported findings regarding the crystallization of proteins were investigated. The Protein Data Bank (PDB) is the largest available repository of solved protein structures and contains a wealth of information on successful crystallization. Many centres have used their own experimental data to draw conclusions about proteins and the conditions in which they crystallize. Here, data from the PDB were used to reanalyse some of these results. The most successful crystallization reagents were identified, the link between solution pH and the isoelectric point of the protein was investigated and the possibility of predicting whether a protein will crystallize was explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallization and X-ray diffraction analysis of the CH domain of the cotton kinesin GhKCH2

The cloning, expression, purification and crystallization of the CH domain of the plant-specific kinesin GhKCH2 is reported. GhKCH2 belongs to a group of plant-specific kinesins (KCHs) containing an actin-binding calponin homology (CH) domain in the N-terminus. Previous studies revealed that the GhKCH2 CH domain (GhKCH2-CH) had a higher affinity for F-actin (K{sub d} = 0.42 ± 0.02 µM) than most other CH-domain-containing proteins. To understand the underlying mechanism, prokaryotically expressed GhKCH2-CH (amino acids 30–166) was purified and crystallized. Crystals were grown by the sitting-drop vapour-diffusion method using 0.1 M Tris–HCl pH 7.0, 20%(w/v) PEG 8000 as a precipitant. The crystals diffracted to a resolution of 2.5 Å and belonged to space group P2{sub 1}, with unit-cell parameters a = 41.57, b = 81.92, c = 83.00 Å, α = 90.00, β = 97.31, γ = 90.00°. Four molecules were found in the asymmetric unit with a Matthews coefficient of 2.22 Å{sup 3} Da{sup −1}, corresponding to a solvent content of 44.8%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of low-pH cements for immobilisation of intermediate level radioactive waste: achievements and challenges

Although cementation is a widely recognized solidification/ stabilization process for immobilisation of Intermediate Level Radioactive Waste (ILRW), the low resistance to hyper-alkaline pore waters compromises the effectiveness of the process when Portland Cement (PC) is employed. Moreover the manufacture of PC is responsible for significant CO{sub 2} emissions. In this context, low pH cements are environmentally more suitable and have emerged as a potential alternative for obtaining secure waste forms. This paper summarises the achievements on development of low-pH cements and the challenges of using these new materials for the ILRW immobilisation. The performance of waste forms is also discussed in terms of radionuclides release. Reactive magnesium oxide and magnesium phosphate cements are emphasised as they feature important advantages such as consumption of available constituents for controlling acid-base reactions, reduced permeability and higher density. Additionally, in order to identify new opportunities for study, the long-term modelling approach is also briefly discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Some physiochemical and heavy metal concentration in surface water streams of Tutuka in the Kenyasi mining catchment area

This research was conducted in the Akantansu stream of Tutuka in Kenyasi in the Brong Ahafo Region of Ghana in the months of October and November 2010 and January 2011. The major objectives of the study were to measure levels of pH, BOD (biochemical oxygen demand), lead, chromium, and arsenic in the Akantansu stream of Tutuka and to find ways that the community could ensure safe water use. To achieve the objectives of the study, sampling was done over a period of three months and data was collected and analyzed into graphs and ANOVA tables. The research revealed that the levels of arsenic and BOD were high as compared to the standards of WHO and EPA. If the people of Tutuka continue to use the stream, they may experience negative health effects (e.g., nausea, vomiting, diarrhea, etc.). The level of pH, chromium and lead was acceptable as compared to the standard of WHO and EPA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-02: Imaging and Radiation Oncology Core (IROC) Houston QA Center (RPC) Credentialing

Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Methods: IROC Houston issues credentials for NCI sponsored study groups. Requirements for credentialing might include any combination of questionnaires, knowledge assessment forms, benchmarks, or phantom irradiations. Credentialing requirements for specific protocols can be found on IROC Houston's website (irochouston.mdanderson.org). The website also houses the credentialing status inquiry (CSI) form. Once an institution has reviewed the protocol's credentialing requirements, a CSI form should be completed and submitted to IROC Houston. This form is used both to request whether requirements have been met as well as to notify IROC Houston that the institution requests credentialing for a specific protocol. IROC Houston will contact the institution to discuss any delinquent requirements. Once the institution has met all requirements IROC Houston issues a credentialing letter to the institution and will inform study groups and other IROC offices of the credentials. Institutions can all phone the IROC Houston office to initiate credentialing or ask any credentialing related questions. Results: Since 2010 IROC has received 1313 credentialing status inquiry forms. We received 317 in 2010, 266 in 2011, 324 in 2012, and 406 in 2013. On average we receive 35 phone calls per week with multiple types of credentialing questions. Decisions regarding credentialing status are based on the protocol specifications and previous completed credentialing by the institution. In some cases, such as for general IMRT credentialing, up to 5 sites may be credentialed based on the credentialing of one main center. Each of these situations is handled individually. Conclusion: IROC Houston will issue radiation therapy credentials for the NCI trials in the National Clinical Trials Network. Credentialing requirements and the CSI form can be found online at the IROC Houston's website. Work supported by PHS grant CA10953 and CA081647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

SU-E-I-11: Cascaded Linear System Model for Columnar CsI Flat Panel Imagers with Depth Dependent Gain and Blur

Purpose: To implement a depth dependent gain and blur cascaded linear system model (CLSM) for optimizing columnar structured CsI indirect conversion flat panel imager (FPI) for advanced imaging applications. Methods: For experimental validation, depth dependent escape efficiency, e(z), was extracted from PHS measurement of different CsI scintillators (thickness, substrate and light output). The inherent MTF and DQE of CsI was measured using high resolution CMOS sensor. For CLSM, e(z) and the depth dependent MTF(f,z), were estimated using Monte Carlo simulation (Geant4) of optical photon transport through columnar CsI. Previous work showed that Monte Carlo simulation for CsI was hindered by the non-ideality of its columnar structure. In the present work we allowed variation in columnar width with depth, and assumed diffusive reflective backing and columns. Monte Carlo simulation was performed using an optical point source placed at different depth of the CsI layer, from which MTF(z,f) and e(z) were computed. The resulting e(z) with excellent matching with experimental measurements were then applied to the CLSM, Monte Carlo simulation was repeated until the modeled MTF, DQE(f) also match experimental measurement. Results: For a 150 micron FOS HL type CsI, e(z) varies between 0.56 to 0.45, and the MTF at 14 cycles/mm varies between 62.1% to 3.9%, from the front to the back of the scintillator. The overall MTF and DQE(f) at all frequencies are in excellent agreement with experimental measurements at all frequencies. Conclusion: We have developed a CLSM for columnar CsI scintillators with depth dependent gain and MTF, which were estimated from Monte Carlo simulation with novel optical simulation settings. Preliminary results showed excellent agreement between simulation results and experimental measurements. Future work is aimed at extending this approach to optimize CsI screen optic design and sensor structure for achieving higher DQE(f) in cone-beam CT, which uses high kVp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-87: Comparison Study of Dose Reconstruction From Cylindrical Diode Array Measurements, with TLD Measurements and Treatment Planning System Calculations in Anthropomorphic Head and Neck and Lung Phantoms

Purpose: To assess dose calculated by the 3DVH software (Sun Nuclear Systems, Melbourne, FL) against TLD measurements and treatment planning system calculations in anthropomorphic phantoms. Methods: The IROC Houston (RPC) head and neck (HN) and lung phantoms were scanned and plans were generated using Eclipse (Varian Medical Systems, Milpitas, CA) following IROC Houston procedures. For the H and N phantom, 6 MV VMAT and 9-field dynamic MLC (DMLC) plans were created. For the lung phantom 6 MV VMAT and 15 MV 9-field dynamic MLC (DMLC) plans were created. The plans were delivered to the phantoms and to an ArcCHECK (Sun Nuclear Systems, Melbourne, FL). The head and neck phantom contained 8 TLDs located at PTV1 (4), PTV2 (2), and OAR Cord (2). The lung phantom contained 4 TLDs, 2 in the PTV, 1 in the cord, and 1 in the heart. Daily outputs were recorded before each measurement for correction. 3DVH dose reconstruction software was used to project the calculated dose to patient anatomy. Results: For the HN phantom, the maximum difference between 3DVH and TLDs was -3.4% and between 3DVH and Eclipse was 1.2%. For the lung plan the maximum difference between 3DVH and TLDs was 4.3%, except for the spinal cord for which 3DVH overestimated the TLD dose by 12%. The maximum difference between 3DVH and Eclipse was 0.3%. 3DVH agreed well with Eclipse because the dose reconstruction algorithm uses the diode measurements to perturb the dose calculated by the treatment planning system; therefore, if there is a problem in the modeling or heterogeneity correction, it will be carried through to 3DVH. Conclusion: 3DVH agreed well with Eclipse and TLD measurements. Comparison of 3DVH with film measurements is ongoing. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

SU-E-T-543: Is It Feasible to Tighten the Criteria for IROC's Anthropomorphic Phantoms?

Purpose: To analyze results of IROC Houston QA center's (RPC) H and N and prostate IMRT phantoms to determine the effect that tightening criteria would have on the phantom pass rate. Methods: IROC Houston's anthropomorphic H and N and prostate phantoms are used to credential institution's to participate in NCI clinical trials that allow the use of IMRT. The phantoms are shipped to institutions where they are filled with water and undergo imaging, treatment planning, and irradiation as a patient would. Each phantom houses targets and organs at risk. They also hold film and TLD. Dosimeter results are compared to the institution's treatment plan using the criteria of 7% for PTV TLD doses and ≥85% pixels must pass 7%/4 mm global gamma analyses. Pass rates for the H and N and prostate phantoms were recalculated using the following tighter criteria options: 1) 5% TLD and 85% pixels 7%/4 gamma2) 5% TLD and 90% pixels 7%/4 gamma3) 5% TLD and 85% pixels 5%/4 gammaGamma analysis was repeated for the 30 most recent irradiations of each phantom to estimate results for criteria 3. Results: Pass rates using current criteria for the H and N and prostate phantoms are 84% and 85% respectively. Pass rates since gamma criteria were introduced in 2012 are 90% and 87%. Criteria 1 applied to all irradiations drops pass rates to 78% and 82%. Applying it to only irradiations with gamma results give 77% and 84%. Applying criteria 2 to only phantoms with gamma results drops pass rates to 80% and 74% and they fall to 83% and 67% respectively using criteria 3. Conclusion: Applying tighter criteria to phantom results has potential to increase quality in clinical trials. The results of the 30 most recent irradiations indicate that there may be room to tighten H and N phantom criteria in the future. Work supported by PHS grant CA10953 and CA081647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

SU-C-201-02: Quantitative Small-Animal SPECT Without Scatter Correction Using High-Purity Germanium Detectors

Purpose: To evaluate the impact of the exceptional energy resolution of germanium detectors for preclinical SPECT in comparison to conventional detectors. Methods: A cylindrical water phantom was created in GATE with a spherical Tc-99m source in the center. Sixty-four projections over 360 degrees using a pinhole collimator were simulated. The same phantom was simulated using air instead of water to establish the true reconstructed voxel intensity without attenuation. Attenuation correction based on the Chang method was performed on MLEM reconstructed images from the water phantom to determine a quantitative measure of the effectiveness of the attenuation correction. Similarly, a NEMA phantom was simulated, and the effectiveness of the attenuation correction was evaluated. Both simulations were carried out using both NaI detectors with an energy resolution of 10% FWHM and Ge detectors with an energy resolution of 1%. Results: Analysis shows that attenuation correction without scatter correction using germanium detectors can reconstruct a small spherical source to within 3.5%. Scatter analysis showed that for standard sized objects in a preclinical scanner, a NaI detector has a scatter-to-primary ratio between 7% and 12.5% compared to between 0.8% and 1.5% for a Ge detector. Preliminary results from line profiles through the NEMA phantom suggest that applying attenuation correction without scatter correction provides acceptable results for the Ge detectors but overestimates the phantom activity using NaI detectors. Due to the decreased scatter, we believe that the spillover ratio for the air and water cylinders in the NEMA phantom will be lower using germanium detectors compared to NaI detectors. Conclusion: This work indicates that the superior energy resolution of germanium detectors allows for less scattered photons to be included within the energy window compared to traditional SPECT detectors. This may allow for quantitative SPECT without implementing scatter correction, reducing uncertainties introduced by scatter correction algorithms. Funding provided by NIH/NIBIB grant R01EB013677; Todd Peterson, Ph.D., has had a research contract with PHDs Co., Knoxville, TN.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-103: An Evaluation of Multiple Irradiations of the IROC Houston QA Center Anthropomorphic Liver Phantom

Purpose: Analyze the results from irradiations of an anthropomorphic liver phantom based on irradiation technique and number of isocenters used for the SBRT delivery. Methods: The phantom consists of a water-fillable plastic shell that has a polystyrene insert, representing the liver which includes two Solid WaterTM targets (PTV1 and PTV2) mimicking liver metastases. The two targets, PTV1 and PTV2 are non-coplanar and are an ovoid 2 cm in diameter and 2.5 cm long and a 3 cm diameter sphere, respectively. Each PTV houses one TLD and 2 planes of radiochromic film. The phantom and a motion table to simulate respiratory motion is sent to institutions sthat are instructed to design and deliver a stereotactic treatment plan that delivers 6 Gy to ≥ 95% of each PTV. The maximum motion of the phantom on the motion table was 1 cm in the superior-inferior direction. Results: Irradiations from 93 institutions have been analyzed. The acceptance criteria are ±7% for the TLD and 85% of the pixels in a region surrounding each PTV passing a ±7%/4 mm global gamma analysis. Sixty-seven (71%) irradiations meet this criteria. The majority, 74 (80%), of the irradiations were performed with IMRT. 73% of the IMRT deliveries were within criteria and 68% of the 3D CRT delivery were within criteria. 32 of the irradiations had a single isocenter plan, 50 were performed with two isocenters and 11 irradiations were performed with CyberKnife and TomoTherapy units where the concept of isocenter is not applicable. The pass rate for the single, dual and no isocenter irradiations were 69%, 74% and 73%, respectively and are not statistically different. Conclusion: The pass rate for the anthropomorphic liver phantom is approximately 70%. There does not seem to be any correlation with number of isocenters used or irradiation technique used for the delivery. This work was supported by PHS CA180803 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-04: The CREATE Medical Physics Research Training Network: Training of New Generation Innovators

Purpose: Over the past century, physicists have played a major role in transforming scientific discovery into everyday clinical applications. However, with the increasingly stringent requirements to regulate medical physics as a health profession, the role of physicists as scientists and innovators has become at serious risk of erosion. These challenges trigger the need for a new, revolutionized training program at the graduate level that respects scientific rigor, attention for medical physics-relevant developments in basic sciences, innovation and entrepreneurship. Methods: A grant proposal was funded by the Collaborative REsearch and Training Experience program (CREATE) of the Natural Sciences and Engineering Research Council (NSERC) of Canada. This enabled the creation of the Medical Physics Research Training Network (MPRTN) around two CAMPEP-accredited medical physics programs. Members of the network consist of medical device companies, government (research and regulatory) and academia. The MPRTN/CREATE program proposes a curriculum with three main themes: (1) radiation physics, (2) imaging & image processing and (3) radiation response, outcomes and modeling. Results: The MPRTN was created mid 2013 (mprtn.com) and features (1) four new basic Ph.D. courses; (2) industry participation in research projects; (3) formal job-readiness training with involvement of guest faculty from academia, government and industry. MPRTN activities since 2013 include 22 conferences; 7 workshops and 4 exchange travels. Three patents were filed or issued, nine awards/best papers were won. Fifteen journal publications were accepted/published, 102 conference abstracts. There are now 13 industry partners. Conclusion: A medical physics research training network has been set up with the goal to harness graduate student’s job-readiness for industry, government and academia in addition to the conventional clinical role. Two years after inception, significant successes have been booked, but the true challenge will be to demonstrate that with this training philosophy CREATE scholars gain access to a much broader job market. Supported by the Natural Sciences and Engineering Research Council (NSERC) Canada.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-05: Results From Multi-Institutional Measurements with An Anthropomorphic Spine Phantom

Purpose: To analyze the results from an anthropomorphic spine phantom used for credentialing institutions for National Cancer Institute (NCI) sponsored clinical trial. Methods: An anthropomorphic phantom that contains left and right lungs, a heart, an esophagus, spinal cord, bony material and a PTV was sent to institutions wishing to be credentialed for NCI trials. The PTV holds 4 TLD and radiochromic film in the axial and sagittal planes. The heart holds one TLD. Institutions created IMRT plans to cover ≥90% of the PTV with 6 Gy and limit the cord dose to <0.35cc receiving 3.75 Gy and <1.2cc receiving 2.63 Gy. They were instructed to treat the phantom as they would a patient, including making plan specific IMRT/SBRT QA measurements before treatment. The TLD results in the PTV were required to be within ±7% of the plan dose. A gamma calculation was performed using the film results and the submitted DICOM plan. ≥85% of the analyzed region was required to pass a 5%/3 mm criteria. Results: 176 institutions irradiated the spine phantom for a total of 255 results. The pass rate was 73% (187 irradiations) overall. 44 irradiations failed only the gamma criteria, 2 failed only the dose criteria and 22 failed both. The most used planning systems were Eclipse (116) and Pinnacle (52) and they had pass rates of 76% and 71%, respectively. The AAA algorithm had a pass rate of 77% while superposition type algorithms had a 71% pass rate. The average TLD measurement to institution calculation ratio was 0.99 (0.04 std dev.). The average percent pixels passing the gamma criteria for films was 89% (12% std dev.) Conclusion: Results show that this phantom is an important part of credentialing and that we have room for improvement in IMRT/SBRT spine treatments. This work was supported by PHS CA180803 and CA037422 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

SU-F-T-676: Measurement of Hydroxyl Radicals in Radiolized Water Systems

Purpose: Hydroxyl radicals can be produced within tissue by radiation therapy, and they are largely responsible for DNA damage and cell killing. Coumarin-3-carboxylic acid (3-CCA) and crystal violet are reported to react with hydroxyl radicals and can be used for fluorescence and absorbance measurements, respectively. This study assesses the ability of hydroxyl measurement for both 3-CCA and crystal violet in radiolized water systems in order to provide dosimetric information in radiation chemistry and radiation biology experiments. Methods: 3-CCA and crystal violet were both dissolved in phosphate buffered saline (PBS, pH 7.4) with final concentrations 0.5 mg/mL and 0.05 mg/mL. 3-CCA and control solutions (PBS only) were loaded in black bottom 96-well plates. Crystal violet and control solutions were loaded in clear bottom 96-well plates. The prepared solutions were irradiated at 2 Gy using a small animal radiation research platform. Fluorescence reading with 360 nm excitation wavelength and 485 nm emission wavelength was done for 3-CCA, and absorbance reading at wavelength 580 nm was done for crystal violet before and after radiation. Results: 3-CCA showed clear difference in fluorescence before and after radiation, which suggested hydroxyl production during radiation. However, crystal violet absorbance at 580 nm was not changed significantly by radiation. Conclusion: The overall conclusion is that 3-CCA can be used for hydroxyl measurement in radiolized water systems, while crystal violet cannot, although crystal violet is reported widely to react with hydroxyl radicals produced in Fenton reactions. Possible reasons could relate to reaction pH.

60 APPLIED LIFE SCIENCES↗

Draft Genome Sequence of thermoalkaliphilic Caldalkalibacillus thermarum strain TA2.A1 Reveals Molecular Adaptations to Extreme pH and Temperature

The genes and molecular machines that allow for a thermoalkaliphilic lifestyle have not been defined. To address this goal, we report on the improved high-quality draft genome sequence of Caldalkalibacillus thermarum strain TA2.A1, an obligately aerobic bacterium that grows optimally at pH 9.5 and 65 to 70 C on a wide variety of carbon and energy sources.

59 BASIC BIOLOGICAL SCIENCES↗