Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Synthesis of Recycled Poly(ethylene terephthalate)/Polyacrylonitrile/Styrene Composite Nanofibers by Electrospinning and Their Mechanical Properties Evaluation

Consumption of polyethylene terephthalate (PET) products has increased dramatically in recent decades, resulting in the generation of a large amount of PET waste. For that reason, is necessary to find a new application of recycled material. In this article, we report the synthesis and characterization of recycled poly (ethylene terephthalate) (RPET) obtained from the chemical recycling of post-consumer PET bottles by glycolysis method and the formation of composites nanofibers RPET/polyacrylonitrile (PAN)/styrene (ST). The RPET synthesis was studied through infrared spectroscopy (FT-IR) and thermogravimetric analysis (TGA). The viscosity and frequency sweep of the polymeric solutions was evaluated. The composites nanofibers were elaborated by the electrospinning technique and characterized by scanning electron microscopy (SEM), FT-IR, TGA/DSC and nanoindentation. The RPET/PAN/ST composite nanofibers present an average diameter of 456 nm and higher thermal stability compared PAN fibers. The mechanical properties such as hardness and elastic modulus were 4.5 and 7.5 times PAN fibers values, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation

Introduction: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. Methods: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. Results: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. Conclusion: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP3 approximation compared with the diffusion approximation.

59 BASIC BIOLOGICAL SCIENCES↗

Recurrent prostate cancer after radical prostatectomy: restaging performance of 18F-choline hybrid PET/MRI

To evaluate the diagnostic performance of a whole-body 18F-choline (FCH) hybrid PET/MRI for prostate cancer patients at biochemical relapse after radical prostatectomy (RP) compared to pelvic multiparametric MRI (mpMRI), one of the standard imaging modality for this patient population. From 2010 to 2016, 58 whole-body FCH PET/MRI studies with mpMRI acquisitions were performed in 53 prostate cancer patients relapsing after curative RP. Median PSA and PSA doubling time (PSA DT) at PET study were 1.5 ng/ml and 6.5 months, respectively. The overall positivity rate of FCH PET/MRI was 58.6% (n = 34), dropping to 44% in patients with a PSA ≤ 2 ng/ml (n = 36). Median PSA values in positive and negative PET/MRI studies were 2.2 ng/ml and 0.8 ng/ml, respectively, with no differences in PSA DT (6.5 vs. 6.6 months). A PSA value ≥ 1.5 ng/ml was a significant predictor of positivity on PET/MRI studies. Compared to PET, mpMRI identified more local relapses (17 vs. 14, p = 0.453) while PET outperformed whole-body Dixon MRI for regional (16 vs. 9, p = 0.016) and distant (12 vs. 6, p = 0.031) metastases. Compared to pelvic mpMRI, the treatment approach turned out to be influenced more frequently using whole-body FCH hybrid PET/MRI studies (58.6% vs. 38%). In prostate cancer patients with biochemical recurrence after RP, whole-body FCH PET/MRI achieved a higher detection rate of nodal/distant metastases compared to pelvic mpMRI alone, increasing the change of treatment strategy by more than 20%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early risk stratification using Rubidium-82 positron emission tomography in STEMI patients

Background: Assessment of infarct size after myocardial infarction is predictive of subsequent morphological changes and clinical outcome. This study aimed to assess subacute post-intervention Rubidium-82 ({sup 82}Rb)-PET imaging in predicting left ventricle ejection fraction, regional wall motion, and final infarct size by CMR at 3-months after STEMI. Methods: STEMI patients undergoing percutaneous coronary intervention were included prospectively. Rest-only {sup 82}Rb-PET perfusion imaging was performed at median 36 hours [IQR: 22 to 50] after the treatment. The extent of hypoperfusion and absolute blood flow (mL·min·g) were estimated on a global and a 17-segment model with dedicated software. At 3-months follow-up patients completed the CMR functional and late gadolinium enhancement imaging. Results: 42 patients were included, but only 35 had follow-up CMR and constituted the study population. Absolute blood flow was significantly lower in the infarct-related territory compared to remote myocardium, P < .005. Extent of hypoperfusion correlated with final infarct size, r = 0.58, P < .001, while blood flow correlated with ejection fraction, r = 0.41, P < .05. In linear mixed models, higher subacute absolute blood flow (β = 4.6, confidence interval [3.5; 5.2], P < .001, R{sup 2} = 0.67) was associated with greater wall motion. Segmental extent of subacute hypoperfusion (β = 0.43 [0.38; 0.49], P < .001, R{sup 2} = 0.58) was associated with the degree of late gadolinium enhancement at 3-months. Conclusions: Subacute rest-only {sup 82}Rb-PET is feasible following STEMI and seems predictive of myocardial function and infarct size at 3-months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Imaging Techniques in Skull Base Osteomyelitis Due to Malignant Otitis Externa

Purpose of Review: To give an up-to-date overview of the strengths and weaknesses of current imaging modalities in diagnosis and follow-up of skull base osteomyelitis (SBO). Recent Findings: CT and MRI are both used for anatomical imaging, and nuclear techniques aid in functional process imaging. Hybrid techniques PET-CT and PET-MRI are the newest modalities which combine imaging strengths. Summary: No single modality is able to address the scope of SBO. A combination of functional and anatomical imaging is needed, in the case of newly suspected SBO we suggest the use of PET-MRI (T1, T2, T1-FS-GADO, DWI) and separate HRCT for diagnosis and follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploration of target molecules for molecular imaging of inflammatory bowel disease

Highlights: {sup {yields}18}F-FDG PET could discriminate each inflamed area of IBD model mice clearly. {sup {yields}18}F-FDG PET could not discriminate the difference of pathogenic mechanism. {yields} Cytokines and cytokine receptors expression was different by pathogenic mechanism. {yields} Cytokines and cytokine receptors would be new target molecules for IBD imaging. -- Abstract: Molecular imaging technology is a powerful tool for the diagnosis of inflammatory bowel disease (IBD) and the efficacy evaluation of various drug therapies for it. However, it is difficult to elucidate directly the relationships between the responsible molecules and IBD using existing probes. Therefore, the development of an alternative probe that is able to elucidate the pathogenic mechanism and provide information on the appropriate guidelines for treatment is earnestly awaited. In this study, we investigated pathognomonic molecules in the intestines of model mice. The accumulation of fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) in the inflamed area of the intestines of dextran sulfate sodium (DSS)- or indomethacin (IND)-induced IBD model mice was measured by positron emission tomography (PET) and autoradiography to confirm the inflamed area. The results suggested that the inflammation was selectively induced in the colons of mice by the administration of DSS, whereas it was induced mainly in the ilea and the proximal colons of mice by the administration of IND. To explore attractive target molecules for the molecular imaging of IBD, we evaluated the gene expression levels of cytokines and cytokine receptors in the inflamed area of the intestines of both model mice. We found that the expression levels of cytokines and cytokine receptors were significantly increased during the progression of IBD, whereas the expression levels were decreased as the mucosa began to heal. In particular, the expression levels of these molecules had already changed before the symptoms of IBD appeared. In addition, the alterations of cytokine and cytokine receptor expression levels indicated differences in the expression pattern depending on the pathogenic mechanism or the region of inflammation (e.g., TNF-{alpha}). Our results suggest that these cytokines or cytokine receptors participate in the pathogenesis of IBD and are valuable biomarkers for the detection of the different circumstances underlying inflammation by the molecular imaging method. Finally, the development of an imaging probe for our target molecules is expected to improve our understanding of the inflammatory conditions of IBD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high throughput assay to detect enzymatic polyethylene oxidation

Biological plastics deconstruction and upcycling have emerged as sustainable alternatives to traditional recycling technologies for plastics waste. The discovery and engineering of efficient thermostable poly(ethylene terephthalate) (PET) hydrolases have made biological PET recycling possible at scale; however, enzymes for non-PET plastics, which account for approximately 70% of all plastics produced, remain largely undiscovered. To accelerate the discovery of such enzymes, we develop a high-throughput screen to detect initial polymer oxidation, specifically that of the C-H bond to an aldehyde. We test 4-hydrazino-7-nitro-2,1,3-benxoxadiozole hydrazine (NBD-H), which reacts with generated aldehydes to form a fluorescent hydrazone on plasma oxidized low-density polyethylene (LDPE) films. Hydrazone generation correlated well with the area of aldehyde peaks as measured by Fourier Transform Infrared Spectroscopy (FTIR) (R2 = 0.92). Moreover, we demonstrate that the probe reliably identifies LDPE-active dye decolorizing peroxidases (DyPs) that generate aldehydes on LDPE films (1.7 – 3.0 fold change relative to background), serving as an effective screen as demonstrated by receiver operating characteristic area under the curve of 0.95. Furthermore, this assay offers an LDPE oxidation screening platform that can be readily parallelized and automated for accelerated discovery of enzymes involved in polyolefin deconstruction.

biocatalysis↗

Association of pediatric asthma severity with exposure to common household dust allergens

Background: Reducing exposure to household dust inhalant allergens has been proposed as one strategy to reduce asthma. Objective: To examine the dose-response relationships and health impact of five common household dust allergens on disease severity, quantified using both symptom frequency and medication use, in atopic and non-atopic asthmatic children. Methods: Asthmatic children (N=300) aged 4-12 years were followed for 1 year. Household dust samples from two indoor locations were analyzed for allergens including dust mite (Der p 1, Der f 1), cat (Fel d 1), dog (Can f 1), cockroach (Bla g 1). Daily symptoms and medication use were collected in monthly telephone interviews. Annual disease severity was examined in models including allergens, specific IgE sensitivity and adjusted for age, gender, atopy, ethnicity, and mother's education. Results: Der p 1 house dust mite allergen concentration of 2.0 {mu}g/g or more from the main room and the child's bed was related to increased asthma severity independent of allergic status (respectively, OR 2.93, 95% CI 1.37, 6.30 for 2.0-10.0 {mu}g/g and OR 2.55 95% CI 1.13, 5.73 for {>=}10.0 {mu}g/g). Higher pet allergen levels were associated with greater asthma severity, but only for those sensitized (cat OR 2.41 95% CI 1.19, 4.89; dog OR 2.06 95% CI 1.01, 4.22). Conclusion: Higher levels of Der p 1 and pet allergens were associated with asthma severity, but Der p 1 remained an independent risk factor after accounting for pet allergens and regardless of Der p 1 specific IgE status.

60 APPLIED LIFE SCIENCES↗

U.S. domestic cats as sentinels for perfluoroalkyl substances: Possible linkages with housing, obesity, and disease

Perfluoroalkyl substances (PFAS), such as perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), are persistent, globally distributed, anthropogenic compounds. The primary source(s) for human exposure are not well understood although within home exposure is likely important since many consumer products have been treated with different PFAS, and people spend much of their lives indoors. Herein, domestic cats were used as sentinels to investigate potential exposure and health linkages. PFAS in serum samples of 72 pet and feral cats, including 11 healthy and 61 with one or more primary disease diagnoses, were quantitated using high-resolution time-of-flight mass spectroscopy. All but one sample had detectable PFAS, with PFOS and perfluorohexane sulfonate (PFHxS) ranging from <LOQ to 121 and <LOQ to 235 ng/mL, respectively. PFAS prevalence and geometric means in cats were very similar to contemporary NHANES reports of human sera in the U. S. population. The highest PFAS serum concentrations detected were in indoor cats due to disproportionately elevated PFHxS levels. Ranked by quartile, contingency testing indicated that total PFAS levels were positively associated with living indoors and with higher body weight and body condition scores. Individual PFAS quartile rankings suggested positive associations with respiratory effusion, thyroid, liver, and possibly chronic kidney disease. Domestic cats appear to be useful sentinels for assessing primary PFAS exposure routes, especially indoor sources of relevance to children. Additional case-control studies in pet cats are warranted to better define the potential health associations observed herein. A “One Health” approach assessing humans, pets, and their common environment may improve our understanding of chronic low-level, largely indoor, PFAS exposure and effects in humans and animals alike. - Highlights: • PFAS serum concentrations were measured in healthy and diseased U. S. domestic cats. • Most abundant were PFOS (range < LOQ to 121) and PFHxS (< LOQ to 235 ng/mL). • PFAS geometric means were very similar to that reported in U.S. human sera by NHANES. • Higher ΣPFAS levels were positively associated with living indoors and with obesity. • Associations with lung, liver, thyroid, or kidney disease may guide future studies.

54 ENVIRONMENTAL SCIENCES↗

Noninvasive Assessment of Tumor Microenvironment Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and {sup 18}F-Fluoromisonidazole Positron Emission Tomography Imaging in Neck Nodal Metastases

Purpose: To assess noninvasively the tumor microenvironment of neck nodal metastases in patients with head-and-neck cancer by investigating the relationship between tumor perfusion measured using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and hypoxia measured by {sup 18}F-fluoromisonidazole ({sup 18}F-FMISO) positron emission tomography (PET). Methods and Materials: Thirteen newly diagnosed head-and-neck cancer patients with metastatic neck nodes underwent DCE-MRI and {sup 18}F-FMISO PET imaging before chemotherapy and radiotherapy. The matched regions of interests from both modalities were analyzed. To examine the correlations between DCE-MRI parameters and standard uptake value (SUV) measurements from {sup 18}F-FMISO PET, the nonparametric Spearman correlation coefficient was calculated. Furthermore, DCE-MRI parameters were compared between nodes with {sup 18}F-FMISO uptake and nodes with no {sup 18}F-FMISO uptake using Mann-Whitney U tests. Results: For the 13 patients, a total of 18 nodes were analyzed. The nodal size strongly correlated with the {sup 18}F-FMISO SUV ({rho} = 0.74, p < 0.001). There was a strong negative correlation between the median k{sub ep} (redistribution rate constant) value ({rho} = -0.58, p = 0.042) and the {sup 18}F-FMISO SUV. Hypoxic nodes (moderate to severe {sup 18}F-FMISO uptake) had significantly lower median K{sup trans} (volume transfer constant) (p = 0.049) and median k{sub ep} (p = 0.027) values than did nonhypoxic nodes (no {sup 18}F-FMISO uptake). Conclusion: This initial evaluation of the preliminary results support the hypothesis that in metastatic neck lymph nodes, hypoxic nodes are poorly perfused (i.e., have significantly lower K{sup trans} and k{sub ep} values) compared with nonhypoxic nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Imaging Assessment of Mortality Risk After Head-and-Neck Radiotherapy

Purpose: The optimal roles for imaging-based biomarkers in the management of head-and-neck cancer remain undefined. Unresolved questions include whether functional or anatomic imaging might improve mortality risk assessment for this disease. We addressed these issues in a prospective institutional trial. Methods and Materials: Ninety-eight patients with locally advanced pharyngolaryngeal squamous cell cancer were enrolled. Each underwent pre- and post-chemoradiotherapy contrast-enhanced computed tomography (CT) and {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/CT imaging. Imaging parameters were correlated with survival outcomes. Results: Low post-radiation primary tumor FDG avidity correlated with improved survival on multivariate analysis; so too did complete primary tumor response by CT alone. Although both imaging modalities lacked sensitivity, each had high specificity and negative predictive value for disease-specific mortality risk assessment. Kaplan-Meier estimates confirmed that both CT and FDG-PET/CT stratify patients into distinct high- and low-probability survivorship groups on the basis of primary tumor response to radiotherapy. Subset analyses demonstrated that the prognostic value for each imaging modality was primarily derived from patients at high risk for local treatment failure (human papillomavirus [HPV]-negative disease, nonoropharyngeal primary disease, or tobacco use). Conclusions: CT alone and FDG-PET/CT are potentially useful tools in head-and-neck cancer-specific mortality risk assessment after radiotherapy, particularly for selective use in cases of high-risk HPV-unrelated disease. Focus should be placed on corroboration and refinement of patient selection for imaging-based biomarkers in future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Lymph Node Status Assessed by 18F-Fluorodeoxyglucose Positron Emission Tomography Predicts Low-Risk Group for Distant Recurrence in Locally Advanced Cervical Cancer: A Prospective Study

Purpose: To develop a prediction model to identify a low-risk group for distant recurrence in patients with locally advanced cervical cancer treated by concurrent chemoradiation. Methods and Materials: Prospectively, 62 patients with locally advanced cervical cancer were recruited as a training cohort. Clinical variables and parameters obtained from positron emission tomography (PET) and magnetic resonance imaging were analyzed by logistic regression. For the test set, 54 patients were recruited independently. To identify the low-risk group, negative likelihood ratio (LR) less than 0.2 was set to be a cutoff. Results: Among the training cohort, multivariate logistic analysis revealed that advanced International Federation of Gynecology and Obstetrics (FIGO) stage and a high serum squamous cancer cell (SCC) antigen level were significant risk factors (p = 0.015 and 0.025, respectively). Using the two parameters, criteria to determine a low-risk subset for distant recurrence were postulated: (1) FIGO Stage IIB or less and (2) pretreatment SCC < 2.4 (Model A). Positive pelvic node on PET completely predicted all cases with distant recurrence and thus was considered as another prediction model (Model B). In the test cohort, although Model A did not showed diagnostic performance, Model B completely predicted all cases with distant recurrence and showed a sensitivity of 100% with negative LR of 0. Across the training and test cohort (n = 116), the false negative rate was 0 (95% confidence interval 0%-7.6%). Conclusions: Positive pelvic node on PET is a useful marker in prediction of distant recurrence in patients with locally advanced cervical cancer who are treated with concurrent chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postradiation Metabolic Tumor Volume Predicts Outcome in Head-and-Neck Cancer

Purpose: To explore the prognostic value of metabolic tumor volume measured on postradiation {sup 18}F-fluorodeoxyglucose positron emission tomography (PET) imaging in patients with head-and-neck cancer. Methods and Materials: Forty-seven patients with head-and-neck cancer who received pretreatment and posttreatment PET/computed tomography (CT) imaging along with definitive chemoradiotherapy were included in this study. The PET/CT parameters evaluated include the maximum standardized uptake value, metabolic tumor volume (MTV{sub 2.0}-MTV{sub 4.0}; where MTV{sub 2.0} refers to the volume above a standardized uptake value threshold of 2.0), and integrated tumor volume. Kaplan-Meier and Cox regression models were used to test for association between PET endpoints and disease-free survival and overall survival. Results: Multiple postradiation PET endpoints correlated significantly with outcome; however, the most robust predictor of disease progression and death was MTV{sub 2.0}. An increase in MTV{sub 2.0} of 21cm{sup 3} (difference between 75th and 25th percentiles) was associated with an increased risk of disease progression (hazard ratio [HR]= 2.5, p = 0.0001) and death (HR = 2.0, p = 0.003). In patients with nonnasopharyngeal carcinoma histology (n = 34), MTV{sub 2.0} <18 cm{sup 3} and MTV{sub 2.0} {>=}18 cm{sup 3} yielded 2-year disease-free survival rates of 100% and 63%, respectively (p = 0.006) and 2-year overall survival rates of 100% and 81%, respectively (p = 0.009). There was no correlation between MTV{sub 2.0} and disease-free survival or overall survival with nasopharyngeal carcinoma histology (n = 13). On multivariate analysis, only postradiation MTV{sub 2.0} was predictive of disease-free survival (HR = 2.47, p = 0.0001) and overall survival (HR = 1.98, p = 0.003). Conclusions: Postradiation metabolic tumor volume is an adverse prognostic factor in head-and-neck cancer. Biomarkers such as MTV are important for risk stratification and will be valuable in the future with risk-adapted therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of both the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron Emission Tomography for Assessing Local Failure After Stereotactic Body Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: We analyzed whether positron emission tomography (PET)/computed tomography standardized uptake values (SUVs) after stereotactic body radiotherapy (SBRT) could predict local recurrence (LR) in non-small-cell lung cancer (NSCLC). Methods and Materials: This study comprised 128 patients with Stage I (n = 68) or isolated recurrent/secondary parenchymal (n = 60) NSCLC treated with image-guided SBRT to 50 Gy over 4 consecutive days; prior radiotherapy was allowed. PET/computed tomography scans were obtained before therapy and at 1 to 6 months after therapy, as well as subsequently as clinically indicated. Continuous variables were analyzed with Kruskal-Wallis tests and categorical variables with Pearson chi-square or Fisher exact tests. Actuarial local failure rates were calculated with the Kaplan-Meier method. Results: At a median follow-up of 31 months (range, 6-71 months), the actuarial 1-, 2-, and 3-year local control rates were 100%, 98.5%, and 98.5%, respectively, in the Stage I group and 95.8%, 87.6%, and 85.8%, respectively, in the recurrent group. The cumulative rates of regional nodal recurrence and distant metastasis were 8.8% (6 of 68) and 14.7% (10 of 68), respectively, for the Stage I group and 11.7% (7 of 60) and 16.7% (10 of 60), respectively, for the recurrent group. Univariate analysis showed that SUVs obtained 12.1 to 24 months after treatment for the Stage I group (p = 0.007) and 6.1 to 12 months and 12.1 to 24 months after treatment for the recurrent group were associated with LR (p < 0.001 for both). Of the 128 patients, 17 (13.3%) had ipsilateral consolidation after SBRT but no elevated metabolic activity on PET; none had LR. The cutoff maximum SUV of 5 was found to have 100% sensitivity, 91% specificity, a 50% positive predictive value, and a 100% negative predictive value for predicting LR. Conclusions: PET was helpful for distinguishing SBRT-induced consolidation from LR. SUVs obtained more than 6 months after SBRT for NSCLC were associated with local failure. A maximum SUV greater than 5, especially at more than 6 months after SBRT, should prompt biopsy to rule out LR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metabolic Imaging Biomarkers of Postradiotherapy Xerostomia

Purpose: Xerostomia is a major complication of head and neck radiotherapy (RT). Available xerostomia measures remain flawed. [{sup 18}F]fluorodeoxyglucose-labeled positron emission tomography-computed tomography (FDG-PET-CT) is routinely used for staging and response assessment of head and neck cancer. We investigated quantitative measurement of parotid gland FDG uptake as a potential biomarker for post-RT xerostomia. Methods and Materials: Ninety-eight locally advanced head and neck cancer patients receiving definitive RT underwent baseline and post-RT FDG-PET-CT on a prospective imaging trial. A separate validation cohort of 14 patients underwent identical imaging while prospectively enrolled in a second trial collecting sialometry and patient-reported outcomes. Radiation dose and pre- and post-RT standard uptake values (SUVs) for all voxels contained within parotid gland ROI were deformably registered. Results: Average whole-gland or voxel-by-voxel models incorporating parotid D{sub Met} (defined as the pretreatment parotid SUV weighted by dose) accurately predicted posttreatment changes in parotid FDG uptake (e.g., fractional parotid SUV). Fractional loss of parotid FDG uptake closely paralleled early parotid toxicity defined by posttreatment salivary output (p < 0.01) and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer xerostomia scores (p < 0.01). Conclusions: In this pilot series, loss of parotid FDG uptake was strongly associated with acute clinical post-RT parotid toxicity. D{sub Met} may potentially be used to guide function-sparing treatment planning. Prospective validation of FDG-PET-CT as a convenient, quantifiable imaging biomarker of parotid function is warranted and ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗