Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles

A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

43 PARTICLE ACCELERATORS↗

A measurement of the high-mass $\tau \overline{\tau}$ production cross-section at $\sqrt{s}=13$ TeV with the ATLAS detector and constraints on new particles and couplings

The production cross-section of high-mass τ-lepton pairs is measured as a function of the dilepton visible invariant mass, using 140 fb −1 of $\sqrt{s}=13$ TeV proton-proton collision data recorded with the ATLAS detector at the Large Hadron Collider. The measurement agrees with the predictions of the Standard Model. A fit to the invariant mass distribution is performed as a function of b-jet multiplicity, to constrain the non-resonant production of new particles described by an effective field theory or in models containing leptoquarks or Z′ bosons that couple preferentially to third-generation fermions. The constraints on new particles improve on previous results, and the constraints on effective operators include those affecting the anomalous magnetic moment of the τ-lepton.

beyond Standard Model↗

Some doubts about the Earth's dust cloud.

Inconclusiveness of satellite measurements of micrometeoroid fluxes using piezoelectric microphone detectors in supporting hypothesis of cloud of dust surrounding Earth

MICROMETEOROID↗

First results from the HMPID detector in the ALICE experiment at LHC

The ALICE experiment is dedicated to the study of heavy-ion collisions at LHC energies. ALICE has a high-quality hadron identification system in the central region e.g. a Inner Tracking System, a large Time-Projection-Chamber, a Time-Of-Flight and the High Momentum Particle Identification Detector (HMPID). The ALICE HMPID detector has been designed to identify charged hadrons ({rho}, K, p) in the momentum range 1<p<5 GeV/c. Despite its limited geometrical acceptance, less than 10% of the central ALICE barrel, the HMPID detector has successfully accumulated enough statistics during the first proton-proton runs at LHC, to allow the detector alignment and to evaluate the calibration parameters needed to estimate its performance. Preliminary HMPID results from p-p collisions at {radical}(s) = 7 TeV and its future contribution to the ALICE physics programme, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a pattern recognition algorithm for reconstructing multi-particle events in the Mu2e detector

Mu2e is an upcoming experiment at Fermilab and its main goal is to search for the Charged Lepton Flavor Violation (CLFV) in the coherent transition of a muon into an electron on an Al target. In Mu2e, multi-particle events can occur simultaneously within the same time region and it is crucial to accurately identify each particle track, including signals, to improve the robustness of track finding methods and enhance reconstruction efficiency. ¯p annihilation is one of the background events and produces multiple particles that can mimic signal events. Additionally, photons from radiative pion captures can produce a γ → $e+e−$ pair, which can be used to calibrate the Mu2e momentum scale and the resolution. The Mu2e track reconstruction sequence begins by grouping hits produced in the tracker based on time and z coordinate information, called TimeCluster, and selected hits are processed to reconstruct helices and determine their momentum. The current pattern recognition algorithms identify a single helix per TimeCluster for single track events. A new pattern recognition algorithm is being developed to reconstruct multi-particle events and its features for finding multiple tracks and the current evaluation results are reported.

Kitagawa, H. [Pisa U.]↗

Sources of machine-induced background in the ATLAS and CMS detectors at the CERN Large Hadron Collider

One source of experimental background in the CERN Large Hadron Collider (LHC) is particles entering the detectors from the machine. These particles are created in cascades, caused by upstream interactions of beam protons with residual gas molecules or collimators. We estimate the losses on the collimators with SixTrack and simulate the showers with FLUKA and MARS to obtain the flux and distribution of particles entering the ATLAS and CMS detectors. We consider some machine configurations used in the first LHC run, with focus on 3.5 TeV operation as in 2011. Results from FLUKA and MARS are compared and a very good agreement is found. An analysis of logged LHC data provides, for different processes, absolute beam loss rates, which are used together with further simulations of vacuum conditions to normalize the results to rates of particles entering the detectors. We assess the relative importance of background from elastic and inelastic beam-gas interactions, and the leakage out of the LHC collimation system, and show that beam-gas interactions are the dominating source of machine-induced background for the studied machine scenarios. Our results serve as a starting point for the experiments to perform further simulations in order to estimate the resulting signals in the detectors.

Circular colliders↗

A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST

Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (weakly interacting massive particles WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the application of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.

argon↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

1 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi1gev

Single particle gun for ITK (ATLAS) detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 1 GeV (fixed). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi1gev_z150r4

Single particle gun for ITK (ATLAS) detector studies: A particle gun with single pions. One pion per event. Production position is randomly distributed in a cylinder with the radios R=4 mm and -150 mm < Z < 150 mm. Pi+ and Pi- are alternated. Momentum of pions is 1 GeV (fixed). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5]. The sample was created on the request by Simon Viel for the ATLAS ITK studies of pixel layouts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

100 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi04_100gev

Single particle gun for ITK (ATLAS) detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is random in the range 0.4-100 GeV. Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5]. The sample was created by request of H.Gray for ATLAS ITK upgrade studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

100 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi04_100gev_z150r4

Single particle gun for ITK (ATLAS) detector studies: A particle gun with single pions. One pion per event. Production origin is randomly distributed in a cylinder with the radius R=4 mm and -150<Z<150 mm size in Z. Pi+ and Pi- are alternated. Momentum of pions is random in the range 0.4-100 GeV. Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5]. The sample was created by request of H.Gray for ATLAS ITK upgrade studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_muon_eta45_p3tev

Single particle gun for detector studies: Events from a particle gun with single muons. One muon per event. 10000 events per file. Production vertex at (x,y,z,t)=(0,0,0,0). mu+ and mu- are alternated. Momentum is uniform between 1 GeV and 3 TeV. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-4.5, 4.5]. Requested by N.Calace for ATLAS ITK studies

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modification of laminar flow ultrafine condensation particle counters for the enhanced detection of 1 nm condensation nuclei

This paper describes simple modifications to thermally diffusive laminar flow ultrafine condensation particle counters (UCPCs) that allow detection of {approx}1 nm condensation nuclei with much higher efficiencies than have been previously reported. These nondestructive modifications were applied to a commercial butanol based UCPC (TSI 3025A) and to a diethylene glycol-based UCPC (UMN DEG-UCPC). Size and charge dependent detection efficiencies using the modified UCPCs (BNL 3025A and BNL DEGUCPC) were measured with high resolution mobility classified aerosols composed of NaCl, W, molecular ion standards of tetraalkyl ammonium bromide, and neutralizer-generated ions. With negatively charged NaCl aerosol, the BNL 3025A and BNL DEGUCPC achieved detection efficiencies of 37% (90x increase over TSI 3025A) at 1.68 nm mobility diameter (1.39 nm geometric diameter) and 23% (8x increase over UMN DEG-UCPC) at 1.19 nm mobility diameter (0.89 nm geometric diameter), respectively. Operating conditions for both UCPCs were identified that allowed negatively charged NaCl and W particles, but not negative ions of exactly the same mobility size, to be efficiently detected. This serendipitous material dependence, which is not fundamentally understood, suggests that vapor condensation might sometimes allow for the discrimination between air 'ions' and charged 'particles.' As a detector in a scanning mobility particle spectrometer (SMPS), a UCPC with this strong material dependence would allow for more accurate measurements of sub-2 nm aerosol size distributions due to the reduced interference from neutralizer-generated ions and atmospheric ions, and provide increased sensitivity for the determination of nucleation rates and initial particle growth rates.

54 ENVIRONMENTAL SCIENCES↗

Characterization of aerogel and Photomultiplier Tubes for the 12-GeV Hall C Kaon Aerogel Detector at Jefferson Lab

Thomas Jefferson National Accelerator Facility's upgrade from 6-GeV to 12-GeV beam energy requires a new magnetic spectrometer for Hall C. At 6 GeV the High Momentum Spectrometer (HMS) made use of an aerogel threshold Cherenkov detector for particle identification of p/K/p. The HMS is not designed to operate at momenta greater than 7 GeV/c, instead a Super High Momentum Spectrometer (SHMS) will be constructed. An aerogel threshold Cherenkov detector needs to be included in the new spectrometer as well. Pions, kaons and protons of sufficient velocity produce Cherenkov radiation when passing through media with low indices of refraction. Aerogels with n = 1.020 and n = 1.030 will be used for p/K/p separation. A diffusion box, lined with millipore, will collect the light from the Cherenkov radiation. Photomultiplier tubes (PMTs) will then detect the light and convert the photons into an electrical signal that electronics will then be able to interpret. This presentation will show the dependence of the aerogel's signal strength on thickness of stack as well as the PMTs' gain dependence on high voltage.

Wood, Kevin↗