Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printable polyvinyltoluene-based plastic scintillators with pulse shape discrimination

A feasibility of preparing bulk photopolymerized plastics scintillators that contain vinyltoluene with multifunctional monomers, pentaerythritol tetraacrylate is shown. This formulation offers a simple and fast way to prepare polyvinyltoluene-based plastics with efficient fast neutron/gamma pulse shape discrimination (PSD) within minutes. 30 wt% of 2,5-diphenyloxazole (PPO) was added in the mixtures of vinyltoluene and pentaerythritol tetraacrylate with different secondary dyes to understand the effect of dyes on the scintillation. Prepared resins were photopolymerized under different conditions, and the scintillation performance was compared to a commercially available standard, EJ-276. Additional functionality for thermal neutron sensitivity was introduced by the incorporation of 6 Li and 6 B nuclei. With optimized conditions, prepared plastics showed light output up to 90% relative to the same size of EJ-276. Here, the best plastic scintillators had PSD figures of merit (FoMs) up to 2.77 compared to 3.25 of EJ-276. The 3D-printability of the tested formulations was demonstrated.

36 MATERIALS SCIENCE↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Interaction of the Antimicrobial Peptide Aurein 1.2 and Charged Lipid Bilayer

Aurein 1.2 is a potent antimicrobial peptide secreted by frog Litoria aurea. As a short membrane-active peptide with only 13 amino acids in sequence, it has been found to be residing on the surface of lipid bilayer and permeabilizing bacterial membranes at high concentration. However, the detail at the molecular level is largely unknown. Here in this study, we investigated the action of Aurein 1.2 in charged lipid bilayers composed of DMPC/DMPG. Oriented Circular Dichroism results showed that the peptide was on the surface of lipid bilayer regardless of the charged lipid ratio. Only at a very high peptide-to-lipid ratio (~1/10), the peptide became perpendicular to the bilayer, however no pore was detected by neutron in-plane scattering. To further understand how it interacted with charged lipid bilayers, we employed Small Angle Neutron Scattering to probe lipid distribution across bilayer leaflets in lipid vesicles. The results showed that Aurein 1.2 interacted strongly with negatively charged DMPG, causing strong asymmetry in lipid bilayer. At high concentration, while the vesicles were intact, we found additional structure feature on the bilayer. Finally, our study provides a glimpse into how Aurein 1.2 disturbs anionic lipid-containing membranes without pore formation.

59 BASIC BIOLOGICAL SCIENCES↗

Performance of a Compact Gamma Tube Interrogation Source

Active interrogation with high-energy monoenergetic gammas can induce photofission signals in fissile materials while minimizing absorbed radiation dose and background from surrounding materials. A first-generation axial-type gamma generator has been developed that utilizes the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction at a 163 keV resonance to produce monoenergetic 12-MeV gamma-rays. The gamma tube employs a water-cooled cylindrical radio frequency (if) induction ion source capable of producing a proton current density of up to 100 mA/cm{sup 2}. The extracted proton beam bombards a lanthanum hexaboride (LaB{sub 6}) target at energies up to 200 keV. The 12-MeV gamma intensity was measured as a function of proton energy, beam current, and angle. Photofission-induced neutrons from depleted uranium (DU) were measured and compared to MCNPX calculations. After extended operation, the high power density of the proton beam was observed to cause damage to the LaB{sub 6} target and the gamma tube improvements currently being made to mitigate this damage are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

A study on the neutron monitoring system of LHD based on Monte Carlo simulations

Neutron monitoring is quite important because fusion neutrons are a direct evidence of fusion reactions. In calibration experiments of a neutron monitoring system, Monte Carlo calculations play an important role to correct various effects. To perform Monte Carlo calculations for a helical type fusion device, we make a program that can automatically generate an input file of a helical coil geometry for the MCNP code. The neutron spatial distributions and spectra for the helical devices are calculated in the geometries automatically generated by this program. We also discuss in calibration experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A triggerless digital data acquisition system for nuclear decay experiments

In nuclear decay experiments an important goal of the Data Acquisition (DAQ) system is to allow the reconstruction of time correlations between signals registered in different detectors. Classically DAQ systems are based in a trigger that starts the event acquisition, and all data related with the event of that trigger are collected as one compact structure. New technologies and electronics developments offer new possibilities to nuclear experiments with the use of sampling ADC-s. This type of ADC-s is able to provide the pulse shape, height and a time stamp of the signal. This new feature (time stamp) allows new systems to run without an event trigger. Later, the event can be reconstructed using the time stamp information. In this work we present a new DAQ developed for {beta}-delayed neutron emission experiments. Due to the long moderation time of neutrons, we opted for a self-trigger DAQ based on commercial digitizers. With this DAQ a negligible acquisition dead time was achieved while keeping a maximum of event information and flexibility in time correlations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of temperature on performance of {sup 3}He filled neutron proportional counters

Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

View factor estimation of hot spot velocities in inertial confinement fusion implosions at the National Ignition Facility

nertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) suffer from asymmetries in thex-ray drive that degrade capsule performance compared to expectations for a symmetric one-dimensional implosion.Mode 1, or pole-to-pole, drive asymmetry can reduce confinement and implosion efficiency, driving a bulk motion ofthe hot spot that is detectable with neutron diagnostics. Understanding and removing sources of mode 1 asymmetry inICF implosions is important for improving performance, and the three-dimensional nature of the problem makes high-resolution radiation-hydrodynamic modeling extremely computationally expensive. This work describes a reducedorder view factor model that calculates the drive asymmetry induced by beam-to-beam variations in laser delivery andhohlraum diagnostic windows along the equator. Capsule response is estimated by coupling to a Green’s function thatrelates final hot spot velocity to the applied time-varying mode 1 asymmetry. The model makes several predictionsabout the impact of mode 1 drivers such as laser delivery and target misalignment, and achieves good agreementin both magnitude and vector direction for several shots in three families of high-performance platforms. However,notable discrepancies suggest other potential sources of mode 1 asymmetry not captured by the model are also at play

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SOLAR ENERGETIC-PARTICLE RELEASE TIMES IN HISTORIC GROUND-LEVEL EVENTS

Ground-level events (GLEs) are large solar energetic-particle events with sufficiently hard spectra for GeV protons to be detected by neutron monitors at ground level. For each of 30 well-observed historic GLEs from four solar cycles, extending back to 1973, I have plotted onset times versus velocity{sup -1} for particles observed on the IMP-7 and 8, ISEE-3, Wind, and GOES spacecraft and by neutron monitors. A linear fit on such a plot for each GLE determines the initial solar particle release (SPR) time, as the intercept, and the magnetic path length traversed, as the slope, of the fitted line. Magnetic path lengths and SPR times are well determined by the fits and cannot be used as adjustable parameters to make particle and photon emission times coincide. SPR times follow the onsets of shock-induced type II radio bursts and the coronal height of the coronal mass ejection (CME)-driven shock at SPR time can be determined for GLEs spanning an interval of solar longitude of approx140 deg. For a given GLE, all particle species and energies diverge from a single SPR point at a given coronal height and footpoint longitude of the field line to the Earth. These heights tend to increase with longitudinal distance away from the source, a pattern expected for shock acceleration. Acceleration for magnetically well-connected large GLEs begins at approx2 solar radii, in contrast to non-GLEs that have been found to be strongly associated with shocks above approx3 solar radii. The higher densities and magnetic field strengths at lower altitudes may be responsible for the acceleration of higher-energy particles in GLEs, while those GLEs that begin above 3R {sub S} may compensate by having higher shock speeds. These results support the joint dependence of maximum particle energy on magnetic field strength, injected particle density, and shock speed, all predicted theoretically.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid method to resolve the neutrino mass hierarchy by supernova (anti)neutrino induced reactions

We introduce a hybrid method to determine the neutrino mass hierarchy by simultaneous measurements of responses of at least two detectors to antineutrino and neutrino fluxes from accretion and cooling phases of core-collapse supernovae. The (anti)neutrino-nucleus cross sections for {sup 56}Fe and {sup 208}Pb are calculated in the framework of the relativistic nuclear energy density functional and weak interaction Hamiltonian, while the cross sections for inelastic scattering on free protons p(ν-bar {sub e},e{sup +})n are obtained using heavy-baryon chiral perturbation theory. The modelling of (anti)neutrino fluxes emitted from a protoneutron star in a core-collapse supernova include collective and Mikheyev-Smirnov-Wolfenstein effects inside the exploding star. The particle emission rates from the elementary decay modes of the daughter nuclei are calculated for normal and inverted neutrino mass hierarchy. It is shown that simultaneous use of (anti)neutrino detectors with different target material allows to determine the neutrino mass hierarchy from the ratios of ν{sub e}- and ν-bar {sub e}-induced particle emissions. This hybrid method favors neutrinos from the supernova cooling phase and the implementation of detectors with heavier target nuclei ({sup 208}Pb) for the neutrino sector, while for antineutrinos the use of free protons in mineral oil or water is the appropriate choice.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamical signature of fractionalization at a deconfined quantum critical point

Deconfined quantum critical points govern continuous quantum phase transitions at which fractionalized (deconfined) degrees of freedom emerge. Here we study dynamical signatures of the fractionalized excitations in a quantum magnet (the easy-plane J-Q model) that realize a deconfined quantum critical point with emergent O(4) symmetry. By means of large-scale quantum Monte Carlo simulations and stochastic analytic continuation of imaginary-time correlation functions, we obtain the dynamic spin-structure factors in the $S^x$ and $S^z$ channels. In both channels, we observe broad continua that originate from the deconfined excitations. We further identify several distinct spectral features of the deconfined quantum critical point, including the lower edge of the continuum and its form factor on moving through the Brillouin zone. We provide field-theoretical and lattice model calculations that explain the overall shapes of the computed spectra, which highlight the importance of interactions and gauge fluctuations to explain the spectral-weight distribution. We make further comparisons with the conventional Landau O(2) transition in a different quantum magnet, at which no signatures of fractionalization are observed. The distinctive spectral signatures of the deconfined quantum critical point suggest the feasibility of its experimental detection in neutron scattering and nuclear magnetic resonance experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗