Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Thermodynamic properties of a hard/soft-magnetic bilayer model

A model for describing the thermodynamic properties of a hard/soft-magnetic bilayer is proposed and thoroughly studied using the Monte Carlo method. Temperature dependences of the heat capacity, total magnetization, magnetizations of the hard- and soft-magnetic layers, total magnetic susceptibility, and susceptibilities of the hard- and soft-magnetic layers have been calculated by this method in the framework of the proposed model. The obtained temperature dependences of the heat capacity and magnetic susceptibility display double maxima that result from the two phase transitions that take place in the system. The influence of system dimensions on the thermodynamic properties of the model has been considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-375: Passive Scattering to Pencil-Beam-Scanning Comparison for Medulloblastoma Proton Therapy: LET Distributions and Radiobiological Implications

Purpose: To compare the linear energy transfer (LET) distributions between passive scattering and pencil beam scanning proton radiation therapy techniques for medulloblastoma patients and study the potential radiobiological implications. Methods: A group of medulloblastoma patients, previously treated with passive scattering (PS) proton craniospinal irradiation followed by prosterior fossa or involved field boost, were selected from the patient database of our institution. Using the beam geometry and planning computed tomography (CT) image sets of the original treatment plans, pencil beam scanning (PBS) treatment plans were generated for the cranial treatment for each patient, with average beam spot size of 8mm (sigma in air at isocenter). 3-dimensional dose and LET distributions were calculated by Monte Carlo methods (TOPAS) both for the original passive scattering and new pencil beam scanning treatment plans. LET volume histograms were calculated for the target and OARs and compared for the two delivery methods. Variable RBE weighted dose distributions and volume histograms were also calculated using a variable dose and LET-based model. Results: Better dose conformity was achieved with PBS planning compared to PS, leading to increased dose coverage for the boost target area and decreased average dose to the structures adjacent to it and critical structures outside the whole brain treatment field. LET values for the target were lower for PBS plans. Elevated LET values for OARs close to the boosted target areas were noticed, due to end of range of proton beams falling inside these structures, resulting in higher RBE weighted dose for these structures compared to the clinical RBE value of 1.1. Conclusion: Transitioning from passive scattering to pencil beam scanning proton radiation treatment can be dosimetrically beneficial for medulloblastoma patients. LET–guided treatment planning could contribute to better decision making for these cases, especially for critical structures at close proximity to the boosted target area.

60 APPLIED LIFE SCIENCES↗

Atomistic Simulation of the Fission-Fragment-Induced Formation of Defects in a Uranium–Molybdenum Alloy

The formation of defects in a uranium–molybdenum alloy induced by xenon and zirconium ion irradiation with energies typical of fission fragments has been simulated within the two-temperature atomistic model and Monte Carlo method. This has allowed estimating the total number of primary radiation defects formed at the “thermal spike” stage and in collision cascades for different temperatures. The calculated threshold stopping powers of ions responsible for the formation of defects at the thermal spike stage are in good agreement with the available theoretical and experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Exchange Interaction Constants on the Magnetization Reversal in a Hard/Soft Magnetic Bilayer Model

A model is developed to study a hard/soft magnetic bilayer in an external magnetic field by the Monte Carlo method. The influence of the constants of the exchange intralayer and interlayer interactions of the hard magnetic and soft magnetic layers on the magnetization reversal in the magnetic bilayer is investigated. The formation of a spin spring is shown to be mainly determined by the exchange interaction in the soft magnetic layer. Phase diagrams are plotted for the magnetic bilayer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gas flow through a slit into a vacuum in a wide range of rarefaction

Gas flow through a two-dimensional slit into a vacuum is investigated by a direct simulation Monte Carlo method. Results for the mass flow rate are obtained as a function of the rarefaction parameter, which is inversely proportional to the Knudsen number. The distributions of density, temperature and mass velocity, and streamlines are presented. In the free molecular flow regime and in the hydrodynamic limit, our results agree with theoretical asymptotes, and in the transition regime, they compare well with numerical simulations by other authors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Optimal Wavelengths for Light Absorption Spectroscopy Measurements Based on Genetic Algorithm–Particle Swarm Optimization

To select the optimal wavelengths in the light extinction spectroscopy measurement, genetic algorithm–particle swarm optimization (GAPSO) based on genetic algorithm (GA) and particle swarm optimization (PSO) is adopted. The change of the optimal wavelength positions in different feature size parameters and distribution parameters is evaluated. Moreover, the Monte Carlo method based on random probability is used to identify the number of optimal wavelengths, and good inversion effects of the particle size distribution are obtained. The method proved to have the advantage of resisting noise. In order to verify the feasibility of the algorithm, spectra with bands ranging from 200 to 1000 nm are computed. Based on this, the measured data of standard particles are used to verify the algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minibeam radiation therapy for the management of osteosarcomas: A Monte Carlo study

Purpose: Minibeam radiation therapy (MBRT) exploits the well-established tissue-sparing effect provided by the combination of submillimetric field sizes and a spatial fractionation of the dose. The aim of this work is to evaluate the feasibility and potential therapeutic gain of MBRT, in comparison with conventional radiotherapy, for osteosarcoma treatments. Methods: Monte Carlo simulations (PENELOPE/PENEASY code) were used as a method to study the dose distributions resulting from MBRT irradiations of a rat femur and a realistic human femur phantoms. As a figure of merit, peak and valley doses and peak-to-valley dose ratios (PVDR) were assessed. Conversion of absorbed dose to normalized total dose (NTD) was performed in the human case. Several field sizes and irradiation geometries were evaluated. Results: It is feasible to deliver a uniform dose distribution in the target while the healthy tissue benefits from a spatial fractionation of the dose. Very high PVDR values (⩾20) were achieved in the entrance beam path in the rat case. PVDR values ranged from 2 to 9 in the human phantom. NTD{sub 2.0} of 87 Gy might be reached in the tumor in the human femur while the healthy tissues might receive valley NTD{sub 2.0} lower than 20 Gy. The doses in the tumor and healthy tissues might be significantly higher and lower than the ones commonly delivered used in conventional radiotherapy. Conclusions: The obtained dose distributions indicate that a gain in normal tissue sparing might be expected. This would allow the use of higher (and potentially curative) doses in the tumor. Biological experiments are warranted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamics Of Electronic Excitation Of Solids With Ultrashort Laser Pulse

When ultrashort laser pulses irradiate a solid, photoabsorption by electrons in conduction band produces nonequilibrium highly energetic free electrons gas. We study the ionization and excitation of the electronic subsystem in a semiconductor and a metal (solid silicon and aluminum, respectively). The irradiating femtosecond laser pulse has a duration of 10 fs and a photon energy of h-bar {omega} = 38 eV. The classical Monte Carlo method is extended to take into account the electronic band structure and Pauli's principle for electrons excited to the conduction band. In the case of semiconductors this applies to the holes as well. Conduction band electrons and valence band holes induce secondary excitation and ionization processes which we simulate event by event. We discuss the transient electron dynamics with respect to the differences between semiconductors and metals. For metals the electronic distribution is split up into two branches: a low energy distribution as a slightly distorted Fermi-distribution and a long high energy tail. For the case of semiconductors it is split into two parts by the band gap. To thermalize, these excited electronic subsystems need longer times than the characteristic pulse duration. Therefore, the analysis of experimental data with femtosecond lasers must be based on non-equilibrium concepts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser pulse driven control of charge and spin order in the two-dimensional Kondo lattice

Fast and dynamical control of quantum phases is highly desired in the application of quantum phenomena in devices. On the experimental side, ultrafast laser pulses provide an ideal platform to induce femtosecond dynamics in a variety of materials. Here we show that a laser pulse driven heavy fermion system can be tuned to dynamically evolve into a phase, which is not present in equilibrium. Using the state-of-the-art time-dependent variational Monte Carlo method, we perform numerical simulations of realistic laser pulses applied to the Kondo lattice model. By tracking spin and charge degrees of freedom we identify a dynamical phase transition, within the partially Kondo screened phase, from a charge ordered into a metallic state, while preserving the spin order of the system. Furthermore, we propose using high-harmonic generation and nonequilibrium optical conductivity to identify the dynamical phase transition in an ultrafast experiment.

36 MATERIALS SCIENCE↗

First Simultaneous Extraction of Spin-Dependent Parton Distributions and Fragmentation Functions from a Global QCD Analysis

In this paper, we perform the first global QCD analysis of polarized inclusive and semi-inclusive deep-inelastic scattering and single-inclusive $e^+e^-$ annihilation data, simultaneously fitting the parton distribution and fragmentation functions using the iterative Monte Carlo method. Without imposing SU(3) symmetry relations, we find the strange polarization to be very small, consistent with zero for both inclusive and semi-inclusive data, which provides a resolution to the strange quark polarization puzzle. Finally, the combined analysis also allows the direct extraction from data of the isovector and octet axial charges, and is consistent with a small SU(2) flavor asymmetry in the polarized sea.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo simulation of the neutron characteristics of VVER-1000 core using the MCU-PD program and comparison of the results with calculations by the BIPR-7A program and experimental data

The Monte Carlo method has been used to simulate the neutron transport in nuclear reactors for over fifty years. Fast progress in computer power and development of more and more robust and reliable algorithms, codes, and nuclear databases allow solving more challenging problems, including three-dimensional (3D) simulations of full-scale reactor cores. Short descriptions of a full-scale 3D model of the VVER-1000 core and algorithms and methods implemented in the MCU-PD and BIPR-7A codes and a comparison of the calculations by each program as well as a comparison with experimental data are given in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-610: Comparison of Output Factors for Small Radiation Fields Used in SBRT Treatment

Purpose: In order to fundamentally understand our previous dose verification results between measurements and calculations from treatment planning system (TPS) for SBRT plans for different sized targets, the goal of the present work was to compare output factors for small fields measured using EDR2 films with TPS and Monet Carlo (MC) simulations. Methods: 6MV beam was delivered to EDR2 films for each of the following field sizes; 1×1 cm{sup 2}, 1.5×1.5 cm{sup 2}, 2×2 cm{sup 2}, 3×3 cm{sup 2}, 4×4 cm{sup 2}, 5×5 cm{sup 2} and 10×10 cm{sup 2}. The films were developed in a film processer, then scanned with a Vidar VXR-16 scanner and analyzed using RIT113 version 6.1. A standard calibration curve was obtained with the 6MV beam and was used to get absolute dose for measured field sizes. Similar plans for all fields sizes mentioned above were generated using Eclipse with the Analytical Anisotropic Algorithm. Similarly, MC simulations were carried out using the MCSIM, an in-house MC code for different field sizes. Output factors normalized to 10×10 cm{sup 2} reference field were calculated for different field sizes in all the three cases and compared. Results: For field sizes ranging from 1×1 cm{sup 2} to 2×2 cm{sup 2}, the differences in output factors between measurements (films), TPS and MC simulations were within 0.22%. For field sizes ranging from 3×3cm{sup 2} to 5×5cm{sup 2}, differences in output factors were within 0.10%. Conclusion: No clinically significant difference was obtained in output factors for different field sizes acquired from films, TPS and MC simulations. Our results showed that the output factors are predicted accurately from TPS when compared to the actual measurements and superior dose calculation Monte Carlo method. This study would help us in understanding our previously obtained dose verification results for small fields used in the SBRT treatment.

60 APPLIED LIFE SCIENCES↗

A microfocus x-ray source based on a nonmetal liquid-jet anode

We demonstrate stable operation of a nonmetallic anode in an electron-impact x-ray source. A high-brightness electron beam is focused on a {approx}70 m/s speed, {approx}10 {mu}m diameter methanol jet producing stable x-ray emission with peak spectral brightness at {approx}5.4x10{sup 5} photons/(sx{mu}m{sup 2}xsrx0.1%BW). The jet is fully evaporated in the interaction point. The shape of a simulated spectrum using Monte Carlo methods shows good agreement with experimental data, and the theoretical brightness values give an upper limit for the achievable x-ray emission from jets with very high velocities. Using this anode concept, all compounds and elements found in liquid form are potentially usable for x-ray generation.

36 MATERIALS SCIENCE↗

Residual entropy of ice III from Monte Carlo simulation

We calculated the residual entropy of ice III as a function of the occupation probabilities of hydrogen positions α and β assuming equal energies of all configurations. To do this, a discrete ice model with Bjerrum defect energy penalty and harmonic terms to constrain the occupation probabilities was simulated by the Metropolis Monte Carlo method for a range of temperatures and sizes followed by thermodynamic integration and extrapolation to N = ∞. Similarly as for other ices, the residual entropies are slightly higher than the mean-field (no-loop) approximation. However, the corrections caused by fluctuation of energies of ice samples calculated using molecular models of water are too large for accurate determination of the chemical potential and phase equilibria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo simulation of Touschek effect.

We present a Monte Carlo method implementation in the code elegant for simulating Touschek scattering effects in a linac beam. The local scattering rate and the distribution of scattered electrons can be obtained from the code either for a Gaussian-distributed beam or for a general beam whose distribution function is given. In addition, scattered electrons can be tracked through the beam line and the local beam-loss rate and beam halo information recorded.

43 PARTICLE ACCELERATORS↗

Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solid water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.

60 APPLIED LIFE SCIENCES↗

Scalar field theory with a nonstandard potential

We study the phase structure of a 4D complex scalar field theory with a potential V({phi})=|({lambda}{sup 3}/{phi})-{lambda}{phi}|{sup 2} at zero and at finite temperature. The model is analyzed by mean-field and Monte Carlo methods. At zero temperature the theory falls in the universality class of the 4D Ising model when varying {lambda}. The situation is less clear cut for variations with respect to {lambda} at large temperatures and variations with respect to temperature at a given value of {lambda}. We observe temperature independence of the mass of the first excitation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The evolution of brachytherapy treatment planning

Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer-based dose-calculation algorithms. The current approach is based on the AAPM TG-43 formalism with recent advances in acquiring single-source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose-calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose-calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗