Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monolithic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Sensor Network Demonstration for In Situ Decommissioning - 13332

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy's (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and large scale demonstrations of promising technologies. During FY11, FIU collaborated with Savannah River National Laboratory in the development of an experimental test site for the demonstration of multiple sensor systems for potential use in the in situ decommissioning process. In situ decommissioning is a process in which the above ground portion of a facility is dismantled and removed, and the underground portion is filled with a cementious material such as grout. In such a scenario, the question remains on how to effectively monitor the structural health of the grout (cracking, flexing, and sinking), as well as track possible migration of contaminants within and out of the grouted monolith. The right types of sensors can aid personnel in better understanding the conditions within the entombed structure. Without sensors embedded in and around the monolith, it will be very difficult to estimate structural integrity and contaminant transport. Yet, to fully utilize the appropriate sensors and the provided data, their performance and reliability must be evaluated outside a laboratory setting. To this end, a large scale experimental setup and demonstration was conducted at FIU. In order to evaluate a large suite of sensor systems, FIU personnel designed and purchased a pre-cast concrete open-top cube, which served as a mock-up of an in situ DOE decommissioned facility. The inside of the cube measures 10 ft x 10 ft x 8 ft. In order to ensure that the individual sensors would be immobilized during the grout pouring activities, a set of nine sensor racks were designed. The 270 sensors provided by Idaho National Laboratory (INL), Mississippi State University (MSU), University of Houston (UH), and University of South Carolina (USC) were secured to these racks based on predetermined locations. Once sensor racks were installed inside the test cube, connected and debugged, approximately 32 cubic yards of special grout material was used to entomb the sensors. MSU provided and demonstrated four types of fiber loop ring-down (FLR) sensors for detection of water, temperature, cracks, and movement of fluids. INL provided and demonstrated time differenced 3D electrical resistivity tomography (ERT), advanced tensiometers for moisture content, and thermocouples for temperature measurements. University of Houston provided smart aggregate (SA) sensors, which detect crack severity and water presence. An additional UH sensor system demonstrated was a Fiber Bragg Grating (FBG) fiber optic system measuring strain, presence of water, and temperature. USC provided a system which measured acoustic emissions during cracking, as well as temperature and pH sensors. All systems were connected to a Sensor Remote Access System (SRAS) data networking and collection system designed, developed and provided by FIU. The purpose of SRAS was to collect and allow download of the raw sensor data from all the sensor system, as well as allow upload of the processed data and any analysis reports and graphs. All this information was made available to the research teams via the Deactivation and Decommissioning Knowledge Management and Information Tool (D and D KM-IT). As a current research effort, FIU is performing an energy analysis, and transferring several sensor systems to a Photovoltaic (PV) System to continuously monitor energy consumption parameters and overall power demands. Also, One final component of this research is focusing on developing an integrated data network to capture, log and analyze sensor system data in near real time from a single interface. FIU personnel and DOE Fellows monitored the progress and condition of the sensors for a period of six months. During this time, the sensors recorded data pertaining to strain, compression, temperature, crack detection, moisture presence, fluid mobility, shock resistance, monolith movement, and electrical resistivity. In addition, FIU regularly observed the curing process of the grout and documented the cube condition via the nine racks of sensors. The sensors held up throughout the curing process, withstood the natural elements for six months, and monitored the integrity of the grout. The large scale experiment and demonstration conducted at FIU was the first of its kind to demonstrate the feasibility of state of the art sensors for in situ decommissioning applications. These efforts successfully measured the durability, performance, and precision of the sensors in question as well as monitored and recorded the curing process of the selected grout material under natural environmental conditions. The current energy analysis work is resulting in data on the constraints placed by some of the sensor systems on a power network that requires high reliability and low losses. In addition, a sensor system demonstration has determined that it is feasible to develop an integrated data network where data can be accessed in near real-time from all systems, thereby allowing for larger-scale integrated system testing to be performed. Information collected during the execution of this research project will aid decision makers in the identification of sensors to be used in nuclear facilities selected for in situ decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experience with Inner Reflector Plug exchange in SNS

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source target monolith, which houses the mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018. The old IRP was extracted from the target monolith, providing space for the new one. It was split into three segments, each of which was handled separately. The lowest section of the IRP is the largest segment in size and in activity and is temporarily stored on-site for cool down before conduction post irradiation examination. In support of planning the replacement activities, a wide range of activation and transport analyses were performed. This included calculating isotope inventories and the radiation fields for each segment as it is extracted in storage casks, and the radiation field from the empty IRP pit in the target monolith. While the replacement was taking place, measurements were performed and later on compared to the calculations. During these studies, it was discovered that a significant contributor to the radiation field from the lower IRP segment is from photo-neutrons. Photo-nuclear physics was added to the analyses and calculated results compared well with measured dose rates.

Popova, Irina I.↗

Dynamic Leaching Method for Intact Salt-stone Samples - 18495

At the Savannah River Site (SRS) low activity salt solution is stabilized via encapsulation within a grout termed salt-stone. Salt-stone is emplaced into large (multi-million liter) concrete storage containers referred to as Salt-stone Disposal Units (SDUs). Technetium-99 (Tc-99) and iodine-129 (I-129) are long-lived radionuclides contained in the low activity salt waste and subsequently incorporated into the grout waste form: both radionuclides are contributors to the potential long-term radiation exposure of the public and environment surrounding the SDUs. With respect to Tc-99, in the reducing, high pH environment within the grout, Tc-99 is expected to be relatively immobile since it exists in a reduced Tc(IV) oxidation state in the form of sparingly soluble hydrated oxides (TcO{sub 2}.xH{sub 2}O) or sulfides (TcS{sub x}). However, in the presence of O{sub 2} (associated with the future infiltration of air or oxygenated ground waters into the salt-stone monolith) it is possible for redox-sensitive Tc(IV) to transition into highly soluble (and mobile) Tc(VII) species, such as pertechnetate (TcO{sub 4}{sup -}), which are more readily transported to the surrounding environment. In contrast, I-129 is highly soluble and its leaching behavior is not anticipated to be significantly impacted by potential changes in redox environment or pH within salt-stone. Traditional approaches to quantifying the leaching behavior of Tc-99 and I-29 from cementitious matrices have involved partitioning experiments using size-reduced (crushed/ground) samples, and determination of the radionuclide fraction immobilized by the cementitious solids. Such experiments create artificially high solid-liquid contact areas that likely result in higher Tc-99 and I-129 leachate concentrations than would be expected for intact, monolithic samples. In the current study a new technique, termed the Dynamic Leaching Method (DLM), is being used to initially investigate the Tc-99 leaching behavior from monolithic salt-stone samples; the system will be used at a later date to evaluate the leaching characteristics of I-129. The data derived using this technique is intended to inform the SRS Salt-stone Disposal Facility (SDF) Performance Assessment (PA) which models the long-term transport of radionuclides from the SDUs to the environment. The DLM utilizes a flexible-wall permeameter to achieve saturated leaching under an elevated hydraulic gradient to simulate and accelerate the future transport of groundwater through salt-stone. Leachates are regularly analyzed with respect to radionuclide concentrations, key constituent concentrations (e.g., Al, Ca, Mg, Na, Si, CO{sub 3}{sup 2-}, NO{sub 2}{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup 2-}), pH, and reduction potential (E{sub h}) in order to develop an understanding of how chemical changes associated with the pore solution influence grout weathering and radionuclide leaching behavior. This paper provides a brief update with respect to data derived from preliminary Tc-99 leaching evaluations as the DLM was being developed, but the paper is predominantly focused on new sample data in which the DLM technique, pre- and post-DLM salt-stone sample characterization, and leachate analysis protocols have been optimized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life cycle Management of 324 Project High-Activity, Mixed/Low-Level Radioactive Waste - 20506

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) manages the 324 Building and is preparing to remotely excavate and disposition the radioactive soil beneath the building to allow further deactivation of the building. The 324 Building is a non-reactor Category 2 Nuclear Facility located in the 300 Area of the Hanford Site. Records indicate that in October 1986, approximately 516 liters of a concentrated liquid waste stream containing cesium-137 ({sup 137}Cs) and strontium-90 ({sup 90}Sr) spilled onto the floor of a hot cell, B-Cell, in the 324 Building. The spill contained an estimated 1.3 million curies (Ci) of radioactivity. A breach in the sump of B-Cell was discovered in November 2009 during characterization of the soil under the building. Exposure rates in excess of 10,000 R/hr were detected through a system of access pipes installed under the hot cell, and an estimated 1.557 E+05 Ci of {sup 137}Cs and 6.842 E+04 Ci of {sup 90}Sr are in the soil beneath B-Cell. The magnitude of the soil contamination below B-Cell represents one of the most challenging remediation activities in the DOE complex. The objective of CHPRC's 324 Project is to remotely excavate and disposition the highly contaminated soil under the hot cell so building deactivation and stabilization activities can resume. Depending on the volume and radioactivity of contaminated soil under B-Cell, the material will be dispositioned either at the Hanford Site's Environmental Restoration Disposal Facility (ERDF) or in grout monoliths that will be created in the hot cells (A, C and D) next to B-Cell during future building demolition activities. The current project scope includes installing structural supports under the walls of B-Cell and using remotely operated equipment to remove debris from the hot cell, remove debris mixed with grout on the floor, saw through and remove the cell floor and liner, and excavate contaminated soil under B-Cell to a depth of up to 3.66 meters (12 feet). Addition or removal of debris in A-Cell may be required to support B-Cell cleanout and excavation activities. The base approach is to disposition debris and soil bins in the Radiochemical Engineering Cell (REC) monoliths, and subsequently disposition the monoliths during building demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interfacial Analysis of Blister Formation in U-10Mo Mini-Plates

A thorough investigation of potential failure mechanisms builds confidence in the performance of monolithic U-10wt%Mo (U-10Mo) fuel plates. The lowenriched uranium (LEU) fuel system is currently undergoing qualification as a high U-density fuel that can be used to convert United States high-performance research reactors from high-enriched uranium (HEU) operation. This will require establishing fuel operational limits such that fission products and a coolable geometry are retained, even during off-normal reactor operation conditions [1]. Such off-normal conditions can subject the fuel plates to temperatures where the internal pressure of precipitated fission gasses result in a permanent deformed, raised area of the cladding, referred to as a blister. These blisters can reduce the local coolability of a fuel plate and can even close coolant channels of a fuel assembly, so blistered plates are considered failed regardless of whether the fuel is truly breached. Historically, a marginto- failure is established through out-of-pile blister threshold testing of irradiated fuel plates. This is accomplished by incrementally heating irradiated fuel plates until blisters are observed. This reveals the temperature threshold that would have resulted in a blister if a plate experienced them at those irradiation conditions [2]. While the blister testing itself reveals the temperatures at which the cladding mechanical integrity was exceeded, a more thorough investigation of the interface evolution in proximity to formed blisters may reveal mechanisms as to the blister formation and retention of fission gases. Previous studies have explored potential underlying mechanisms in historical plates that may have been close to blistering [3]; however, this work is the first exploration of blister tested irradiated plates, fabricated by a commercial vendor—another requirement for qualification of the fuel system [1]. The Mini-plate 1 (MP-1) experiment was the first in a series of irradiation and post-irradiation examination (PIE) campaigns to qualify the U-10Mo monolithic fuel system. It consisted of commercially fabricated 25.4×101.5 mm Al-clad mini-plates with a monolithic U-10Mo foil coated in a Zr diffusion barrier. The primary MP-1 PIE campaign was previously completed. Among the suit of examinations was a blister testing campaign, where plates were incrementally annealed in 25°C increments until blisters were observed or a maximum temperature of 550°C was reached [4]. The previously blistered plates from this campaign were revisited in this work.

25228↗

Convergence Criteria for Multiphysics Simulations

The behavior of engineered systems is often influenced by multiple physical phenomena, such as mechanical deformation, heat transfer, and chemical species transport and reactions. There are often strong interactions between these phenomena, and there is increasing interest in applying coupled-physics models to improve understanding of physical behavior under complex environmental conditions. Multiple simulation frameworks that facilitate coupled-physics simulations are in widespread use, and these employ a variety of techniques to account for interactions between those physics. Many frameworks solve the physics models independently and transfer results between them. Alternatively, a single monolithic system of equations for every physics model can be formed and solved. Each of these approaches has its benefits and drawbacks, and the optimal approach varies depending on the nature of the problem. The open-source MOOSE framework was developed targeting solution of large-scale multiphysics problems. Although it provides options for all these coupling approaches, its standard approach for multiphysics solutions is to form and solve a single monolithic system of equations containing the unknowns for all physics models. MOOSE provides a streamlined approach for users to define the solution variables, the terms in the partial differential equations pertaining to each variable, and interactions between solution variables. One aspect of the monolithic solution approach that can be problematic, however, is defining appropriate convergence criteria for the nonlinear system. A standard approach is to determine convergence is to simply take a norm of the residual vector corresponding to the full vector of unknowns. However, if the residual vector contains variables for multiple physics models, the magnitudes of those variables can differ significantly, and the variables can converge at significantly different rates from each other. It is important to ensure that the variables for each of the physics are converged, and also ensure that the convergence criteria are not excessively stringent in cases when there is little change in the solution. This talk presents representative multiphysics problems to highlight these issues, and shows strategies for convergence criteria in MOOSE that are robust for multiphysics models under a variety of conditions.

97 - MATHEMATICS AND COMPUTING↗

Removing Cs within a continuous flow set-up by an ionic exchanger material transformable into a final waste form

Silica monoliths loaded with hexacyanoferrate (HCF) nanoparticles were designed and synthesized to selectively remove Cs + ions from an aqueous saline solution within a continuous flow set-up. The decontamination and hydrodynamic efficiency of this smart material was compared to other granularly supported HCF. Finally, a thermal treatment was applied to transform the HCF functionalized monolith into a final waste form matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aging studies of Dual functional materials for CO 2 direct air capture with in situ methanation under simulated ambient conditions: Ru thrifting for cost reduction

Dual function materials (DFMs) comprised of 0.25 %Ru, 6.1 %Na 2 O/γ-Al 2 O 3 //monolith were evaluated for about 250 hours time-on-stream (TOS) at various simulated ambient climate capture conditions followed by temperature swing methanation to 280 °C. Herein this paper focuses on the impact of thrifting Ru to low levels and the impact on performance. Results showed both stable CO 2 capture capacity and CH 4 production with 0.25 % Ru DFM deposited on a ceramic monolith. The CO 2 conversion to CH 4 production was decreased slightly by the Ru decrease from 1 % to 0.25 %. The capture capacity decreased since a lower Ru content reduces the complete decomposition of the Na 2 CO 3 precursor producing fewer active adsorption sites (“Na 2 O”). The deployment of a low Ru DFM monolith would significantly decrease the overall capital cost and give more potential for a large-scale direct air capture and methanation (DACM) application.

03 NATURAL GAS↗

Microwave assisted heating of plastic waste: Effect of plastic/susceptor (SiC) contacting patterns

We discuss plastic accumulation as a growing sustainability challenge. Most plastics are thermally inert at room temperature, requiring high temperatures for depolymerization. In the quest for developing sustainable plastic upcycling, we investigate silicon carbide (SiC) as microwave absorbing susceptors for reaching depolymerization temperatures. We utilize three SiC topologies – particles, hot-pressed plastic films containing SiC particles, and monoliths. SiC particles of >0.5 mm in diameter can provide heating rates approaching ~200 °C/min at modest powers. Still, physically mixed plastic-susceptor beds suffer from density differences, causing non-uniform contact during plastic softening and melting. Hot-pressed plastic films containing SiC particles allow uniform plastic-susceptor contact but suffer from slow heating as only a single layer of susceptors exists between polymer layers. SiC monoliths mitigate these challenges by preferentially dissipating the microwaves and rapidly heating the plastics independently of polymeric properties.

36 MATERIALS SCIENCE↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pixel test structures implemented in a 65 nm CMOS process

The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20–40 µm and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article. The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at + 20 °C and a detection efficiency of 99% for a DPTS irradiated with a dose of 10 15 1 MeV n eq cm -2 . Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surviving Under Pressure: The Role of Solvent, Crystal Size, and Morphology During Pelletization of Metal–Organic Frameworks

As metal–organic frameworks (MOFs) gain traction for applications, such as hydrogen storage, it is essential to form the as-synthesized powder materials into shaped bodies with high packing densities to maximize their volumetric performance. Mechanical compaction, which involves compressing the materials at high pressure, has been reported to yield high monolith density but often results in a significant loss in accessible porosity. Herein, we sought to systematically control (1) crystal size, (2) solvation, and (3) compacting pressure in the pelletization process to achieve high packing density without compromising the porosity that makes MOFs functional. It was determined that solvation is the most critical factor among the three factors examined. Solvation that exceeds the pore volume prevents the framework from collapsing, allowing for porosity to be maintained through pelletization. Higher pelletization pressure results in higher packing density, with extensive loss of porosity being observed at a higher pressure if the solvation is below the pore volume. Lastly, we observed that the morphology and size of the MOF particles result in variation in the highest achievable packing efficiency, but these numbers (75%) are still greater than many existing techniques used to form MOFs. Furthermore, we concluded that the application of pressure through pelletization is a suitable and widely applicable technique for forming high-density MOF-monoliths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Computational Schemes on Coupled Flow and Geo-Mechanical Modeling of CO 2 Leakage through a Compromised Well

Carbon capture, utilization, and storage (CCUS) describes a set of technically viable processes to separate carbon dioxide (CO 2 ) from industrial byproduct streams and inject it into deep geologic formations for long-term storage. Legacy wells located within the spatial domain of new injection and production activities represent potential pathways for fluids (i.e., CO 2 and aqueous phase) to leak through compromised components (e.g., through fractures or micro-annulus pathways). The finite element (FE) method is a well-established numerical approach to simulate the coupling between multi-phase fluid flow and solid phase deformation interactions that occur in a compromised well system. We assumed the spatial domain consists of a three-phases system: a solid, liquid, and gas phase. For flow in the two fluids phases, we considered two sets of primary variables: the first considering capillary pressure and gas pressure (PP) scheme, and the second considering liquid pressure and gas saturation (PS) scheme. Fluid phases were coupled with the solid phase using the full coupling (i.e., monolithic coupling) and iterative coupling (i.e., sequential coupling) approaches. The challenge of achieving numerical stability in the coupled formulation in heterogeneous media was addressed using the mass lumping and the upwinding techniques. Numerical results were compared with three benchmark problems to assess the performance of coupled FE solutions: 1D Terzaghi’s consolidation, Liakopoulos experiments, and the Kueper and Frind experiments. We found good agreement between our results and the three benchmark problems. For the Kueper and Frind test, the PP scheme successfully captured the observed experimental response of the non-aqueous phase infiltration, in contrast to the PS scheme. These exercises demonstrate the importance of fluid phase primary variable selection for heterogeneous porous media. We then applied the developed model to the hypothetical case of leakage along a compromised well representing a heterogeneous media. Considering the mass lumping and the upwinding techniques, both the monotonic and the sequential coupling provided identical results, but mass lumping was needed to avoid numerical instabilities in the sequential coupling. Additionally, in the monolithic coupling, the magnitude of primary variables in the coupled solution without mass lumping and the upwinding is higher, which is essential for the risk-based analyses.

deformation flow↗

EVALUATION OF U10MO FUEL PLATE IRRADIATION BEHAVIOR VIA NUMERICAL AND EXPERIMENTAL BENCHMARKING

This article analyzes dimensional changes due to irradiation of monolithic plate-type nuclear fuel and compares results with finite element analysis of the plates during fabrication and irradiation. Monolithic fuel plates tested in the Advanced Test Reactor (ATR) at Idaho National Lab (INL) are being used to benchmark proposed fuel performance for several high power research reactors. Post-irradiation metallographic images of plates sectioned at the midpoint were analyzed to determine dimensional changes of the fuel and the cladding response. A constitutive model of the fabrication process and irradiation behavior of the tested plates was developed using the general purpose commercial finite element analysis package, Abaqus. Using calculated burn-up profiles of irradiated plates to model the power distribution and including irradiation behaviors such as swelling and irradiation enhanced creep, model simulations allow analysis of plate parameters that are either impossible or infeasible in an experimental setting. The development and progression of fabrication induced stress concentrations at the plate edges was of primary interest, as these locations have a unique stress profile during irradiation. Additionally, comparison between 2D and 3D models was performed to optimize analysis methodology. In particular, the ability of 2D and 3D models account for out of plane stresses which result in 3-dimensional creep behavior that is a product of these components. Results show that assumptions made in 2D models for the out-of-plane stresses and strains cannot capture the 3-dimensional physics accurately and thus 2D approximations are not computationally accurate. Stress-strain fields are dependent on plate geometry and irradiation conditions, thus, if stress based criteria is used to predict plate behavior (as opposed to material impurities, fine micro-structural defects, or sharp power gradients), unique 3D finite element formulation for each plate is required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of thermal treatment on the co-rolled U-Mo fuel foils

A monolithic fuel type is being developed to convert US high performance research and test reactors such as Advanced Test Reactor (ATR) at Idaho National Laboratory from highly enriched uranium (HEU) to low-enriched uranium (LEU). The interaction between the cladding and the U-Mo fuel meat during fuel fabrication and irradiation is known to have negative impacts on fuel performance, such as mechanical integrity and dimensional stability. In order to eliminate/minimize the direct interaction between cladding and fuel meat, a thin zirconium diffusion barrier was introduced between the cladding and U-Mo fuel meat through a co-rolling process. A complex interface between the zirconium and U-Mo was developed during the co-rolling process. A predictable interface between zirconium and U-Mo is critical to achieve good fuel performance since the interfaces can be the weakest link in the monolithic fuel system. A post co-rolling annealing treatment is expected to create a well-controlled interface between zirconium and U-Mo. A systematic study utilizing post co-rolling annealing treatment has been carried out. Based on microscopy results, the impacts of the annealing treatment on the interface between zirconium and U-Mo will be presented and an optima annealing treatment schedule will be suggested. The effects of the annealing treatment on the fuel performance will also be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Cladding-Cladding Delamination Failures in U-Mo Fuel Plates

Monolithic fuel is a candidate fuel form for the conversion of high-performance research reactors. This plate-type fuel consists of a high-density, U-Mo alloy-based fuel in a monolithic form that is sandwiched between zirconium diffusion barriers and encapsulated in an aluminum cladding. To qualify this fuel system, the program must demonstrate that the fuel meets the safety standards, has a predictable behavior, and performs well in a reactor. Although many plates have shown satisfactory thermo-mechanical performance in reactor, a small number of experimental plates exhibited failures, rendering performance of these plates unacceptable. Post-irradiation examinations of failed plates have revealed that various failures modes are present, including pillowing, blistering, buckling, warping, delamination, fracture, rupture, oxide spallation, etc. Previous studies have implied that such various operational and loading conditions could generate a complex stress-strain state, facilitating distinct failure modes that could impact the structural integrity. To understand such various failure modes, a comprehensive set of studies focusing on failure modes is being performed. As a part of these studies, this work studies the cladding-cladding separation failures that were observed in some of previous irradiation tests. To understand the root cause of cladding separation failures, selected plates from previous irradiation experiments were simulated under comparable operational conditions. Stress-strain state of the plates at the interface were examined. The results were comparatively evaluated to understand possible effects of stress state of the bond-line on delamination failures. This paper presents these findings, discusses such failure modes, and examines the influence of various factors on previously observed cladding delamination failures.

42 ENGINEERING↗

Fracture‐Resistant and Thermally Insulating Ultrahigh‐Temperature Carbide Foams

Dense ultrahigh‐temperature ceramics (UHTCs) carbides are recognized as potential materials for thermal protection systems (TPS) owing to properties beyond existing structural materials’ capabilities. Recent advances in UHTCs have enabled the development of multiscale porous microstructures. Herein, it is highlighted that the porosity in UHTCs are no longer treated as a defect but as a functional property specifically tailored for thermal insulation. It is a promising solution to design and fabricate bulk UHTC foams via a freeze‐drying (FD) approach followed by calibrated pressureless spark plasma sintering. Herein, monolithic TaC and HfC UHTC foams and their composite show the partial solid–solution formation of (Ta, Hf)C with porosity ≥50%. TaC–HfC foam (≈80–92 N) shows an intermediate load‐bearing capability compared to monolithic TaC (≈120–135 N) and HfC (≈28–35 N) foams, with no evident cracking on the sample surface. The thermal conductivity of partial solid‐solution TaC–HfC foam increases up to fivefold compared to parent UHTC foams. In the results, solid solutions’ efficacy and pores’ unidirectionality in providing thermal insulation to TaC–HfC while maintaining its high‐load bearing capability are illustrated. In conclusion, the developed technique establishes a new paradigm shift in UHTCs, expanding their potential for TPS in extreme environments.

36 MATERIALS SCIENCE↗

Formation of Composite SiC/SiC Joints by Embedded Wire Chemical Vapor Deposition

The joining of ceramic monoliths or composites to date has primarily been limited to the formation of brittle monolithic joints using heterogeneous (dissimilar) materials, similar to brazing in metals. The development of a damage-tolerant joint layer by SiC fiber reinforcements is demonstrated here. Tube workpieces made of SiC fiber-SiC matrix composite are joined using a nonwoven SiC fiber mat densified by embedded wire chemical vapor deposition (EWCVD), creating a fiber-reinforced weld-like joint by homogeneous joining. EWCVD uses a localized heating method to target deposition and growth to the joint region specifically, while minimizing thermal damage to the surrounding composite tube material. X-ray computed tomography (XCT) is used to nondestructively characterize as-made joints for relative density, adhesion, and composition. In situ XCT analysis during mechanical testing revealed crack deflections in the bonding layer, which indicates a toughening mechanism typical of ceramic matrix composite phase. Gas permeation testing of these proof-of-concept composite joints identified relatively high leak rates in comparison to fully coated SiC/SiC composite tube workpieces. In conclusion, the novelty of the composite joining method and current technology challenges, including gas permeability, are discussed in comparison with traditional ceramic joints and materials.

SiC↗