Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics↗

Atmospheric temperature, water vapour and liquid water path from two microwave radiometers during MOSAiC

The microwave radiometers HATPRO (Humidity and Temperature Profiler) and MiRAC-P (Microwave Radiometer for Arctic Clouds - Passive) continuously measured radiation emitted from the atmosphere throughout the Multidisciplinary drifting Observatory for the Study of the Arctic Climate (MOSAiC) expedition on board the research vessel Polarstern. From the measured brightness temperatures, we have retrieved atmospheric variables using statistical methods in a temporal resolution of 1 s covering October 2019 to October 2020. The integrated water vapour (IWV) is derived individually from both radiometers. In addition, we present the liquid water path (LWP), temperature and absolute humidity profiles from HATPRO. To prove the quality and to estimate uncertainty, the data sets are compared to radiosonde measurements from Polarstern. The comparison shows an extremely good agreement for IWV, with standard deviations of 0.08–0.19 kg m -2 (0.39–1.47 kg m -2 ) in dry (moist) situations. The derived profiles of temperature and humidity denote uncertainties of 0.7–1.8 K and 0.6–0.45 gm -3 in 0–2 km altitude.

54 ENVIRONMENTAL SCIENCES↗

Non-reciprocal transmission of microwave acoustic waves in nonlinear parity–time symmetric resonators

Acoustic waves are versatile on-chip information carriers that can be used in applications such as microwave filters and transducers. Nonreciprocal devices, in which the transmission of waves is non-symmetric between two ports, are desirable for the manipulation and routing of phonons, but building acoustic non-reciprocal devices is difficult because acoustic systems typically have a linear response. Here, we report non-reciprocal transmission of microwave surface acoustic waves using a nonlinear parity–time symmetric system based on two coupled acoustic resonators in a lithium niobate platform. Furthermore, owing to the strong piezoelectricity of lithium niobate, we can tune the gain, loss and nonlinearity of the system using electric circuitry. Our approach can achieve 10 dB of non-reciprocal transmission for surface acoustic waves at a frequency of 200 MHz, and we use it to demonstrate a one-way circulation of acoustic waves in cascading non-reciprocal devices.

42 ENGINEERING↗

BeyondPlanck: XV. Limits on large-scale polarized anomalous microwave emission from Planck LFI and WMAP

We constrained the level of polarized anomalous microwave emission (AME) on large angular scales using Planck Low-Frequency Instrument (LFI) and WMAP polarization data within a Bayesian cosmic microwave background (CMB) analysis framework. We modeled synchrotron emission with a power-law spectral energy distribution, as well as the sum of AME and thermal dust emission through linear regression with the Planck High-Frequency Instrument (HFI) 353 GHz data. This template-based dust emission model allowed us to constrain the level of polarized AME while making minimal assumptions on its frequency dependence. We neglected CMB fluctuations, but show through simulations that these fluctuations have a minor impact on the results. We find that the resulting AME polarization fraction confidence limit is sensitive to the polarized synchrotron spectral index prior. In addition, for prior means β s < -3.1 we find an upper limit of p AME max ≲ 0.6% (95% confidence). In contrast, for means β s = -3.0, we find a nominal detection of p AME = 2.5 ± 1.0% (95% confidence). These data are thus not strong enough to simultaneously and robustly constrain both polarized synchrotron emission and AME, and our main result is therefore a constraint on the AME polarization fraction explicitly as a function of β s . Combining the current Planck and WMAP observations with measurements from high-sensitivity low-frequency experiments such as C-BASS and QUIJOTE will be critical to improve these limits further.

79 ASTRONOMY AND ASTROPHYSICS↗

p-type conductivity and damage recovery in implanted GaN annealed by rapid gyrotron microwave annealing

We demonstrate p-type activation of GaN doped by Mg ion implantation, and in situ during metalorganic chemical vapor deposition through sequential short-duration gyrotron microwave heating cycles at temperatures of 1200–1350 °C. GaN is implanted with 1019 cm−3 Mg ions, capped with AlN, and annealed under 3 MPa N2 overpressure in 5 s heating cycles for less than 60 s total using a high-power gyrotron microwave heating source. Through I–V characterization, photoluminescence spectroscopy, and Raman spectroscopy, we study the evolution of electrical properties, optically active point defects, and material strain in response to implantation and annealing. For Mg-implanted samples, increasing annealing temperature is characterized by an increase in the PL substitutional Mg-related peak (UVL) relative to the shallow-donor vacancy-related peak (GL2). Through comparison of implanted and in situ doped samples, it is demonstrated that the origin of compensating VN lies primarily in implantation rather than degradation from the annealing process. Transmission line measurements and diode I–V measurements show a sheet resistance of 1083 kΩ/□ and a hole concentration of 1.23 × 1015 cm−3, respectively, in the Mg-implanted material annealed at 1350 °C. We conclude that temperature-cycled gyrotron annealing at 1350 °C decreases implant-induced compensating point defects and activates Mg to obtain selective p-type conduction.

Meyers, V. (ORCID:0000000176731553)↗

Materials loss measurements using superconducting microwave resonators

The performance of superconducting circuits for quantum computing is limited by materials losses. In particular, coherence times are typically bounded by two-level system (TLS) losses at single photon powers and millikelvin temperatures. The identification of low loss fabrication techniques, materials, and thin film dielectrics is critical to achieving scalable architectures for superconducting quantum computing. Superconducting microwave resonators provide a convenient qubit proxy for assessing performance and studying TLS loss and other mechanisms relevant to superconducting circuits such as non-equilibrium quasiparticles and magnetic flux vortices. In this review article, we provide an overview of considerations for designing accurate resonator experiments to characterize loss, including applicable types of losses, cryogenic setup, device design, and methods for extracting material and interface losses, summarizing techniques that have been evolving for over two decades. Results from measurements of a wide variety of materials and processes are also summarized. Finally, we present recommendations for the reporting of loss data from superconducting microwave resonators to facilitate materials comparisons across the field.

47 OTHER INSTRUMENTATION↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct measurement of microwave loss in Nb films for superconducting qubits

Niobium films are a key component in modern two-dimensional superconducting qubits, yet their contribution to the total qubit decay rate is not fully understood. The presence of different layers of materials and interfaces makes it difficult to identify the dominant loss channels in present two-dimensional qubit designs. In this paper, we present the study that directly correlates measurements of RF losses in such films to material parameters by investigating a high-power impulse magnetron sputtered (HiPIMS) film atop a three-dimensional niobium superconducting radio frequency (SRF) resonator. By using a 3D SRF structure, we are able to isolate the niobium film loss from other contributions. Our findings indicate that microwave dissipation in the HiPIMS-prepared niobium films, within the quantum regime, resembles that of record-high intrinsic quality factor of bulk niobium SRF cavities, with lifetimes extending into seconds. Microstructure and impurity level of the niobium film do not significantly affect the losses. These results set the scale of microwave losses in niobium films and show that niobium losses do not dominate the observed coherence times in present two-dimensional superconducting qubit designs, instead highlighting the dominant role of the dielectric oxide in limiting the performance. We can also set a bound for when niobium film losses will become a limitation for qubit lifetimes.

Abdisatarov, B.↗

Investigation of kinetic inductance and microwave loss in thin-film TaC x N 1−x superconducting resonators

The promise of tantalum for realizing superconducting quantum devices has generated interest in its compound films, particularly nitrides. Among these, cubic-phase tantalum carbonitride (TaC x N 1−x ) offers reduced susceptibility to oxidation and a high critical temperature, yet its microwave properties remain largely unexplored. Here, in this study, we investigate plasma-enhanced atomic layer deposition of cubic-phase TaC x N 1−x thin films for superconducting microwave circuits. Structural and transport measurements reveal nanocrystalline morphology with sub-10 nm grains and superconductivity in the dirty limit. Coplanar waveguide resonators exhibit moderately high kinetic inductance (16.8 pH/sq for 30 nm films) with potential for enhancement through dimensional scaling. The films also support high internal quality factors exceeding 10 5 at 50 mK in the single-photon regime, comparable to granular aluminum. Loss analysis identifies the two-level systems as the dominant limiting mechanism, with potential for further reduction through interface engineering. These results establish atomic layer deposited TaC x N 1−x as a promising material for scalable, low-loss, high-inductance superconducting circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave-photonic control of optically accessible spin defects in diamond

A growing variety of optically accessible spin qubits have emerged in recent years as key components for quantum sensors, computers, and memories. However, the scalability of conventional spin-based quantum architectures remains limited by direct microwave delivery, which introduces thermal noise, electromagnetic crosstalk, and design constraints for cryogenic, high-field, and distributed systems. In this work, we present a unified framework for RF-over-fiber (RFoF) control of spins accessible through optically detected magnetic resonance (ODMR) spectroscopy of nitrogen-vacancy (NV) centers in diamond. The RFoF platform relies on an intensity-modulated 1310 nm laser carrying microwave signals over fiber and a high-speed photodiode for optical-to-electrical conversion to drive NV spin transitions. We report an RFoF power-conversion efficiency of 3.42% for an RF output PRF,out=-5.5 dBm at 2.87 GHz, enabling clear resolution of Zeeman splitting in

Rahman, M Reefaz [ORNL] (ORCID:0000000323541611)↗

CMB-PAInT: An inpainting tool for the cosmic microwave background

Abstract The presence of astrophysical emissions in microwave observations forces us to perform component separation to extract the Cosmic Microwave Background (CMB) signal. However, even in the most optimistic cases, there are still strongly contaminated regions, such as the Galactic plane or those with emission from extragalactic point sources, which require the use of a mask. Since many CMB analyses, especially the ones working in harmonic space, need the whole sky map, it is crucial to develop a reliable inpainting algorithm that replaces the values of the excluded pixels by others statistically compatible with the rest of the sky. This is especially important when working withQandUsky maps in order to obtainE- andB-mode maps which are free fromE-to-Bleakage. In this work we study a method based on Gaussian Constrained Realizations (GCR), that can deal with both intensity and polarization. Several tests have been performed to asses the validation of the method, including the study of the one-dimensional probability distribution function (1-PDF),E- andB-mode map reconstruction, and power spectra estimation. We have considered two scenarios for the input simulation: one case with only CMB signal and a second one including also Planck PR4 semi-realistic noise. Even if we are limited to low resolution maps, N side = 64 ifT,QandUare considered, we believe that this is a useful approach to be applied to future missions such as LiteBIRD, where the target are the largest scales.

Astronomy & Astrophysics↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic single-port calibration for superconducting microwave resonator measurements

Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. Additionally, a common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband Nonreciprocity Enabled by Strong Coupling of Magnons and Microwave Photons

Nonreciprocity of signal transmission enhances the capacity of communication channels and protects the transmission quality against possible signal instabilities, thus becoming an important component for ensuring coherent information processing. However, nonreciprocal transmission requires breaking time-reversal symmetry (TRS), which poses challenges of both practical and fundamental character that hinder progress. Here we report an alternative scheme for achieving broadband nonreciprocity using a specially engineered hybrid microwave cavity. The TRS breaking is realized via strong coherent coupling between a selected chiral mode in the microwave cavity and a single collective spin excitation (magnon) in a ferromagnetic yttrium iron garnet sphere. The nonreciprocity in transmission is observed to span nearly a 0.5-GHz frequency band, which outperforms by two orders of magnitude the previously achieved bandwidths. Our findings suggest a promising direction for robust coherent information processing in a broad range of systems in both the classical and the quantum regime.

36 MATERIALS SCIENCE↗

Microscopic examination of rf-cavity-quality niobium films through local nonlinear microwave response

The performance of superconducting radio-frequency (SRF) cavities is sometimes limited by local defects. To investigate the rf properties of these local defects, especially those that nucleate rf magnetic vortices, a near-field magnetic microwave microscope is employed. Local third-harmonic response ( P 3 f ) and its temperature dependence and rf power dependence are measured for one Nb / Cu film grown by direct current magnetron sputtering (DCMS) and six Nb / Cu films grown by high-power impulse magnetron sputtering (HiPIMS) with systematic variation of deposition conditions. Five out of the six HiPIMS Nb / Cu films show a strong third-harmonic response that is likely coming from rf vortex nucleation due to a low- T c surface defect with a transition temperature between 6.3 and 6.8 K, suggesting that this defect is a generic feature of air-exposed HiPIMS Nb / Cu films. A phenomenological model of surface-defect grain boundaries hosting a low- T c impurity phase is introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe-sample interaction to better understand the measured third-harmonic response. The simulation results show that the third-harmonic response of rf vortex nucleation caused by surface defects exhibits the same general features as the data, including peaks in third-harmonic response with temperature, and their shift and broadening with higher microwave amplitude. We find that the parameters of the phenomenological model (the density of surface defects that nucleate rf vortices and the depth an rf vortex travels through these surface defects) vary systematically with film deposition conditions. From the point of view of these two properties, the Nb / Cu film that is most effective at reducing the nucleation of rf vortices associated with surface defects can be identified. Published by the American Physical Society 2024

Wang, Chung-Yang (ORCID:0000000184299633)↗

Seamless High-Q Microwave Cavities for Multimode Circuit Quantum Electrodynamics

Multimode cavity quantum electrodynamics ---where a two-level system interacts simultaneously with many cavity modes---provides a versatile framework for quantum information processing and quantum optics. Due to the combination of long coherence times and large interaction strengths, one of the leading experimental platforms for cavity QED involves coupling a superconducting circuit to a 3D microwave cavity. In this work, we realize a 3D multimode circuit QED system with single photon lifetimes of $2$ ms and cooperativities of $0.5-1.5\times10^9$ across 9 modes of a novel seamless cavity. We demonstrate a variety of protocols for universal single-mode quantum control applicable across all cavity modes, using only a single drive line. We achieve this by developing a straightforward flute method for creating monolithic superconducting microwave cavities that reduces loss while simultaneously allowing control of the mode spectrum and mode-qubit interaction. We highlight the flexibility and ease of implementation of this technique by using it to fabricate a variety of 3D cavity geometries, providing a template for engineering multimode quantum systems with exceptionally low dissipation. This work is an important step towards realizing hardware efficient random access quantum memories and processors, and for exploring quantum many-body physics with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microwave-Free Dynamic Nuclear Polarization via Sudden Thermal Jumps

Dynamic nuclear polarization (DNP) presently stands as the preferred strategy to enhance the sensitivity of nuclear magnetic resonance measurements, but its application relies on the use of high-frequency microwave to manipulate electron spins, an increasingly demanding task as the applied magnetic field grows. Here we investigate the dynamics of a system hosting a polarizing agent formed by two distinct paramagnetic centers near a level anticrossing. We theoretically show that nuclear spins polarize efficiently under a cyclic protocol that combines alternating thermal jumps and radio-frequency pulses connecting hybrid states with opposite nuclear and electronic spin alignment. Central to this process is the difference between the spin-lattice relaxation times of either electron spin species, transiently driving the electronic spin bath out of equilibrium after each thermal jump. Without the need for microwave excitation, this route to enhanced nuclear polarization may prove convenient, particularly if the polarizing agent is designed to feature electronic level anticrossings at high magnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗