Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

High Resolution Electron Microscopy Of Dislocation Ribbons In A CMSX-4 Superalloy single crystal

High-resolution scanning transmission electron microscopy (HR STEM) has been used to study the structure of dislocations in single crystal superalloy samples that have been subjected to conditions that favour the primary creep regime. The study has revealed the detailed structure of extended a 2 h112i dislocations as they shear the 0 precipitates during creep. These dislocations dissociate in a manner that is consistent with the PFMD predictions made and also suggests the importance of the reordering process during their movement. The shearing done by the ah112i dislocationswas also found to distort the/ 0 interface, changing its appearance from linear to a 'saw tooth' pattern. Another important observation was the segregation of alloying element with high atomic mass to the stacking faults to reduce their energies during shear. Numerous a 2 h110i dissociated dislocations were also observed in the channels of the superalloy. The high resolution provided by the STEM imaging enables one to study the high energy faults that are usually di*cult to observe in conventional weak-beam TEM, such as CISF and CESF-1 in the 0 andthe ISF in the, and to make estimates of their energies. Key

36 MATERIALS SCIENCE↗

A test method for determining adhesion forces and Hamaker constants of cementitious materials using atomic force microscopy

A method for determining Hamaker constant of cementitious materials is presented. The method involved sample preparation, measurement of adhesion force between the tested material and a silicon nitride probe using atomic force microscopy in dry air and in water, and calculating the Hamaker constant using appropriate contact mechanics models. The work of adhesion and Hamaker constant were computed from the pull-off forces using the Johnson-Kendall-Roberts and Derjagin-Muller-Toropov models. Reference materials with known Hamaker constants (mica, silica, calcite) and commercially available cementitious materials (Portland cement (PC), ground granulated blast furnace slag (GGBFS)) were studied. The Hamaker constants of the reference materials obtained are consistent with those published by previous researchers. The results indicate that PC has a higher Hamaker constant than GGBFS. The Hamaker constant of PC in water is close to the previously predicted value C{sub 3}S, which is attributed to short hydration time ({<=} 45 min) used in this study.

36 MATERIALS SCIENCE↗

Electron microscopy study of Pd, Ag, and Cs in carbon areas in the locally corroded SiC layer in a neutron-irradiated TRISO fuel particle

Here, a detailed electron microscopy study was performed on focused ion beam-prepared lamellae from different locations relative to a crack across the inner pyrolytic carbon layer of a neutron-irradiated tristructural isotropic-coated particle. The distribution and composition of fission products across the inner pyrolytic carbon and silicon carbide (SiC) layers were studied. Previously, this crack was identified in the particle that released significant inventory fractions of cesium and silver during irradiation and displayed localized palladium pileup with SiC degradation. In this study, carbon areas were found in the SiC layer close to the crack tip and they had precipitates that consisted mostly of palladium silicides or palladium, with silver and/or cadmium frequently identified. Results confirmed that areas in the SiC layer close to the crack tip with localized accumulation of palladium were corroded by palladium, forming pure carbon areas and palladium silicide that provided pathways for silver, cadmium and cesium migration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of pigments in colour layers on walls of some selected historical buildings using optical and scanning electron microscopy

For successful restoration of painted walls and painted coloured finishing coats it is necessary to determine the composition of the original colour layers. Identification of the pigments used in The Cistercian Abbey of Sticna and The Manor of Novo Celje was carried out using optical and scanning electron microscopy. Selected samples of wall paintings were inspected by the combined application of an optical microscope and a low-vacuum Scanning Electron Microscope to determine their colour and structural features and to identify the position of individual pigment grains. Energy dispersive spectroscopy was used to determine the elemental distribution on selected surfaces and elemental composition of individual pigments. It was found that the most abundantly used pigments were iron oxide red, cinnabar, green earth, umber, calcium carbonate white, ultramarine, yellow ochre and carbon black. These identifications have allowed us to compare the use of various pigments in buildings from different historical periods.

36 MATERIALS SCIENCE↗

Comparative determination of the {alpha}/{beta} phase fraction in {alpha}+{beta}-titanium alloys using X-ray diffraction and electron microscopy

A comparison is made between the measured {alpha}/{beta} phase fractions in Ti-6246 using X-ray diffraction (XRD) and electron microscopy. Image analysis of SEM and TEM images was compared to the phase fraction estimate obtained using electron backscattered diffraction, lab and high-energy synchrotron XRD. There was a good agreement between the electron microscopic and diffraction techniques, provided that the microstructural parameters of grain size and texture are estimated correctly when using quantitative Rietveld refinement.

36 MATERIALS SCIENCE↗

Electron microscopy studies of lutetium doped erbium silicide (Er{sub 0.9}Lu{sub 0.1}){sub 5}Si{sub 4}

Examination of bulk microstructures of lutetium doped erbium silicide (Er{sub 0.9}Lu{sub 0.1}){sub 5}Si{sub 4} (space group: Pnma) using scanning and transmission electron microscopy (SEM, TEM) reveals the existence of thin plates of a hexagonal phase (space group: P6{sub 3}/mcm) where the stoichiometric ratio in moles between the rare earths and Si is 5 to 3, i. e the 5:3 phase. The orientation relationship between the matrix and the plates was determined as [010]{sub m} {approx} -parallel [-1010]{sub p.} This observation adds credence to the assumption that all linear features noted in alloys of the rare-earth intermetallic family R{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4} are of the stoichiometric ratio 5:3 and possess a common orientation relationship with the parent 5:4 alloys. - Highlights: {yields} The linear features observed in the (Er{sub 0.9}Lu{sub 0.1}){sub 5}Si{sub 4} sample are hexagonal 5:3 plates. {yields} Thickness of 5:3 plates in 5:4 alloys made by tri-arc pulling is greater than made by arc-melting. {yields} The orientation relationship between 5:3 plates and the matrix is [010]{sub m} {approx} ||[-1010]{sub p}.

36 MATERIALS SCIENCE↗

Magnetic force microscopy study of domain walls in Co{sub 2}Z ferrite

Graphical abstract: - Highlights: • Hexaferrite Co{sub 2}Z is synthesized through the modified Pechini method. • Magnetic domains are observed in anisotropic Co{sub 2}Z single grain using MFM. • Observed single grain domain thickness is in good agreement with Dotsh model. - Abstract: Hexaferrite Co{sub 2}Z was synthesized through the modified Pechini method. Partially oriented samples were obtained after consolidation with uniaxial pressing and calcination/sintering at 1300 °C/1330 °C. The sample composition and morphology was identified with X-ray diffractometry (XRD) and scanning electron microscopy (SEM) with energy-dispersive X-ray spectrometry (EDS). MFM studies of the single grains revealed a domain structure with 0.7 μm wide. The Co{sub 2}Z static magnetization was measured with a vibrating sample magnetometer (VSM), and was used to calculate a single grain domain with a thickness of 4.8 μm. This result is in good agreement with SEM observations of the single grain thickness.

36 MATERIALS SCIENCE↗

Atomic force microscopy of silica nanoparticles and carbon nanohorns in macrophages and red blood cells

The emerging interest in understanding the interactions of nanomaterial with biological systems necessitates imaging tools that capture the spatial and temporal distributions and attributes of the resulting nano-bil amalgam. Studies targeting organ specific response and/ot nanoparticle-specific system toxicity would be profoundly benefited from tools that would allow imaging and tracking of in-vivo or in-vitro processes and particle-fate studies. Recently we demonstrated that mode systhesizing atomic force microscopy (MSAFM) can provide subsurface nanoscale informations on the mechanical properties of materials at the nanoscale. However, the underlying mechanism of this imaging methodology is currently subject to theoretical and experimental investigation. In this paper we present further analysis by investigating tip-sample excitation forces associated with nanomechanical image formation. Images and force curves acquired under various operational frequencies and amplitudes are presented. We examine samples of mouse cells, where buried distributions of single-walled carbon nanohorns and silica nanoparticles are visualized.

Atomic force microscopy↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Atomic force microscopy investigation of the giant mimivirus

Mimivirus was investigated by atomic force microscopy in its native state following serial degradation by lysozyme and bromelain. The 750-nm diameter virus is coated with a forest of glycosylated protein fibers of lengths about 140 nm with diameters 1.4 nm. Fibers are capped with distinctive ellipsoidal protein heads of estimated Mr = 25 kDa. The surface fibers are attached to the particle through a layer of protein covering the capsid, which is in turn composed of the major capsid protein (MCP). The latter is organized as an open network of hexagonal rings with central depressions separated by 14 nm. The virion exhibits an elaborate apparatus at a unique vertex, visible as a star shaped depression on native particles, but on defibered virions as five arms of 50 nm width and 250 nm length rising above the capsid by 20 nm. The apparatus is integrated into the capsid and not applied atop the icosahedral lattice. Prior to DNA release, the arms of the star disengage from the virion and it opens by folding back five adjacent triangular faces. A membrane sac containing the DNA emerges from the capsid in preparation for fusion with a membrane of the host cell. Also observed from disrupted virions were masses of distinctive fibers of diameter about 1 nm, and having a 7-nm periodicity. These are probably contained within the capsid along with the DNA bearing sac. The fibers were occasionally observed associated with toroidal protein clusters interpreted as processive enzymes modifying the fibers.

60 APPLIED LIFE SCIENCES↗

Modelling atomic resolution scanning transmission electron microscopy images

A real-space description of inelastic scattering in scanning transmission electron microscopy is derived with particular attention given to the implementation of the projected potential approximation. A hierarchy of approximations to expressions for inelastic images is presented. Emphasis is placed on the conditions that must hold in each case. The expressions that justify the most direct, visual interpretation of experimental data are also the most approximate. Therefore, caution must be exercised in selecting experimental parameters that validate the approximations needed for the analysis technique used. To make the most direct, visual interpretation of electron-energy-loss spectroscopic images from core-shell excitations requires detector improvements commensurate with those that aberration correction provides for the probe-forming lens. Such conditions can be relaxed when detailed simulations are performed as part of the analysis of experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial Resolution and Information Transfer in Scanning Transmission Electron Microscopy

The relation between image resolution and information transfer is explored. It is shown that the existence of higher frequency transfer in the image is just a necessary but not sufficient condition for the achievement of higher resolution. Adopting a two-point resolution criterion, we suggest that a 10% contrast level between two features in an image should be used as a practical definition of resolution. In the context of scanning transmission electron microscopy, it is shown that the channeling effect does not have a direct connection with image resolution because sharp channeling peaks do not move with the scanning probe. Through a quantitative comparison between experimental image and simulation, a Fourier-space approach is proposed to estimate defocus and sample thickness. The effective atom size in Z-contrast imaging depends on the annular detector's inner angle. Therefore, an optimum angle exists for the highest resolution as a trade-off between reduced atom size and reduced signal with limited information transfer due to noise.

47 OTHER INSTRUMENTATION↗

Three-dimensional scanning transmission electron microscopy of biological specimens

A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2 - 3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original data set. The precision of the height determination was 0.2 nm. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy (TEM). However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

Probing Activities of Individual Catalytic Nanoflakes by Tunneling Mode of Scanning Electrochemical Microscopy

The tunneling mode of scanning electrochemical microscopy (SECM) was developed recently and applied to studies of charge-transfer reactions at single metal nanoparticles (NPs). When an SECM tip is brought within the tunneling distance from a conductive NP, the particle begins to act as a part of the nanoelectrode. Herein, we demonstrate the possibility of using carbon nanoelectrodes with a very thin insulating sheath for electrochemical tunneling experiments at flat samples. In this way, electrocatalytic activity, conductivity, and charging properties of and faradaic processes in layered nanomaterials can be characterized by single-nanoflake voltammetry without making direct ohmic contact with them. A broad applicability of tunneling SECM experiments is demonstrated by probing nanomaterials with different size, geometry, and electrocatalytic properties, including metallic/pseudo-metallic (1T/1T') and semiconducting (2H) MoS 2 nanoflakes, N-doped porous carbon catalyst, and MXene nanosheets. Further, the Tafel plots for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) at individual nanoflakes are compared to analogous measurements for an ensemble of flakes attached to the surface of a macroscopic electrode. Moreover, we observed variations in catalytic activities of individual MXene flakes toward HER and OER caused by non-uniform doping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualization of Plasmonic Couplings Using Ultrafast Electron Microscopy

Hybrids of graphene and metal plasmonic nanostructures are promising building blocks for applications in optoelectronics, surface-enhanced scattering, biosensing, and quantum information. An understanding of the coupling mechanism in these hybrid systems is of vital importance to its applications. Previous efforts in this field mainly focused on spectroscopic studies of strong coupling within the hybrids with no spatial resolution. In this study, we report direct imaging of the local plasmonic coupling between single Au nanocapsules and graphene step edges at the nanometer scale by photon-induced near-field electron microscopy in an ultrafast electron microscope for the first time. The proximity of a step in the graphene to the nanocapsule causes asymmetric surface charge density at the ends of the nanocapsules. Computational electromagnetic simulations confirm the experimental observations. The results reported here indicate that this hybrid system could be used to manipulate the localized electromagnetic field on the nanoscale, enabling promising future plasmonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evolution of the Solid–Electrolyte Interphase on Carbonaceous Anodes Visualized by Atomic-Resolution Cryogenic Electron Microscopy

In this paper, the stability of modern lithium-ion batteries depends critically on an effective solid–electrolyte interphase (SEI), a passivation layer that forms on the carbonaceous negative electrode as a result of electrolyte reduction. However, a nanoscopic understanding of how the SEI evolves with battery aging remains limited due to the difficulty in characterizing the structural and chemical properties of this sensitive interphase. In this work, we image the SEI on carbon black negative electrodes using cryogenic transmission electron microscopy (cryo-TEM) and track its evolution during cycling. We find that a thin, primarily amorphous SEI nucleates on the first cycle, which further evolves into one of two distinct SEI morphologies upon further cycling: (1) a compact SEI, with a high concentration of inorganic components that effectively passivates the negative electrode; and (2) an extended SEI spanning hundreds of nanometers. This extended SEI grows on particles that lack a compact SEI and consists primarily of alkyl carbonates. The diversity in observed SEI morphologies suggests that SEI growth is a highly heterogeneous process. The simultaneous emergence of these distinct SEI morphologies highlights the necessity of effective passivation by the SEI, as large-scale extended SEI growths negatively impact lithium-ion transport, contribute to capacity loss, and may accelerate battery failure.

25 ENERGY STORAGE↗