Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Surface potential and magnetic properties of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} periodic arrays fabricated by direct electron beam writing

It is demonstrated that magnetic periodic arrays can be easily fabricated from direct writing water developable La{sub 0.7}Sr{sub 0.3}MnO{sub 3} electron beam resist. Two unique features of our approach are (1) the patterned La{sub 0.7}Sr{sub 0.3}MnO{sub 3} resist film can be developed using nontoxic and environmentally friendly pure water and (2) either positive or negative patterns can be fabricated depending on the dosage of electron beam. The mechanism of the dual function characteristic of the resist was studied using Kelvin probe microscope. The surface potential of patterned La{sub 0.7}Sr{sub 0.3}MnO{sub 3} resist increases with increasing electron beam dosage due to the changes of resist composition. The formations of periodic magnetic arrays were confirmed by the studies of scanning electron microscope and magnetic force microscope. The magnetization of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} can be enhanced by postsintering the sample at 900 deg. C after electron beam irradiation. We have therefore provided a one-step, simple, and convenient alternative technique for the fabrication of nanoscale magnetic patterns, which form the building blocks for the study of physical properties in periodic magnetic arrays.

36 MATERIALS SCIENCE↗

Effect of medium range order on pulsed laser crystallization of amorphous germanium thin films

Sputter deposited amorphous Ge thin films had their nanostructure altered by irradiation with high-energy Ar + ions. The change in the structure resulted in a reduction in medium range order (MRO) characterized using fluctuation electron microscopy. The pulsed laser crystallization kinetics of the as-deposited versus irradiated materials were investigated using the dynamic transmission electron microscope operated in the multi-frame movie mode. In conclusion, the propagation rate of the crystallization front for the irradiated material was lower; the changes were correlated to the MRO difference and formation of a thin liquid layer during crystallization.

36 MATERIALS SCIENCE↗

Time Refraction of Spin Waves

Here, we present an experimental study of time refraction of spin waves (SWs) propagating in microscopic waveguides under the influence of time-varying magnetic fields. Using space- and time-resolved Brillouin light scattering microscopy, we demonstrate that the broken translational symmetry along the time coordinate results in a loss of energy conservation for SWs and thus allows for a broadband and controllable shift of the SW frequency. With an integrated design of SW waveguide and microscopic current line for the generation of strong, nanosecond-long, magnetic field pulses, a conversion efficiency up to 39% of the carrier SW frequency is achieved, significantly larger compared to photonic systems. Given the strength of the magnetic field pulses and its strong impact on the SW dispersion relation, the effect of time refraction can be quantified on a length scale comparable to the SW wavelength. Furthermore, we utilize time refraction to excite SW bursts with pulse durations in the nanosecond range and a frequency shift depending on the pulse polarity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic hardening of Ce1+xFe11-yCoyTi with ThMn12 structure by melt spinning

A recent study on the intrinsic magnetic properties of CeFe11-yCoyTi has revealed that substituting one Co for Fe retains the favorable magnetocrystalline anisotropy H-a found in the ternary Fe end member, while enhancing the Curie temperature T-c and saturation magnetization 4 pi M-s. These findings warrant further optimization around Co substitution y = 1 to try to exploit the hard magnetic properties of these Ce-based magnets. Both Ce and Co concentrations in Ce1+xFe11-yCoyTi have been optimized in the range of x = 0 0.2 and y = 0 1.5. It was found that Co substitution effectively enhances all hard magnetic properties, although the values are still lower than those predicted from the intrinsic magnetic properties. Specifically, Tc increases from 210 degrees C to 285-350 degrees C; 4 pi M-19 (magnetization at 19 kOe) from 8.9 kG to 10.5-11.5 kG, remanence B-r from 3.1 kG to 4.1-4.5 kG, and most importantly, H-ci from 1.1 kOe to 1.5 kOe. As a result, the room temperature energy product (BH)(max) has been increased by over 100% from 0.7 MGOe in Ce1.1Fe11Ti to 1.5 MGOe in Ce1.05Fe9.75Co1.25Ti. Microscopy analysis indicates that the addition of Co refines the grain size and promotes chemical homogeneity at the microscopic scale. The beneficial effect of Co on the microstructure contributes to the improved hard magnetic properties. (C) 2015 AIP Publishing LLC.

Zhou, C↗

Harnessing quantum light for microscopic biomechanical imaging of cells and tissues

The biomechanical properties of cells and tissues play an important role in our fundamental understanding of the structures and functions of biological systems at both the cellular and subcellular levels. Recently, Brillouin microscopy, which offers a label-free spectroscopic means of assessing viscoelastic properties in vivo, has emerged as a powerful way to interrogate those properties on a microscopic level in living tissues. However, susceptibility to photodamage and photobleaching, particularly when high-intensity laser beams are used to induce Brillouin scattering, poses a significant challenge. This article introduces a transformative approach designed to mitigate photodamage in biological and biomedical studies, enabling nondestructive, label-free assessments of mechanical properties in live biological samples. By leveraging quantum-light-enhanced stimulated Brillouin scattering (SBS) imaging contrast, the signal-to-noise ratio is significantly elevated, thereby increasing sample viability and extending interrogation times without compromising the integrity of living samples. The tangible impact of this methodology is evidenced by a notable three-fold increase in sample viability observed after subjecting the samples to three hours of continuous squeezed-light illumination, surpassing the traditional coherent light-based approaches. The quantum-enhanced SBS imaging holds promise across diverse fields, such as cancer biology and neuroscience where preserving sample vitality is of paramount significance. By mitigating concerns regarding photodamage and photobleaching associated with high-intensity lasers, this technological breakthrough expands our horizons for exploring the mechanical properties of live biological systems, paving the way for an era of research and clinical applications.

Li, Tian↗

A nanostructure thermal property measurement platform.

Measurements of the electrical and thermal transport properties of one-dimensional nanostructures (e.g., nanotubes and nanowires) typically are obtained without detailed knowledge of the specimen's atomic-scale structure or defects. To address this deficiency we have developed a microfabricated, chip-based characterization platform that enables both transmission electron microscopy (TEM) of atomic structure and defects as well as measurement of the thermal transport properties of individual nanostructures. The platform features a suspended heater line that contacts the center of a suspended nanostructure/nanowire that was placed using in-situ scanning electron microscope nanomanipulators. One key advantage of this platform is that it is possible to measure the thermal conductivity of both halves of the nanostructure (on each side of the central heater), and this feature permits identification of possible changes in thermal conductance along the wire and measurement of the thermal contact resistance. Suspension of the nanostructure across a through-hole enables TEM characterization of the atomic and defect structure (dislocations, stacking faults, etc.) of the test sample. As a model study, we report the use of this platform to measure the thermal conductivity and defect structure of GaN nanowires. The utilization of this platform for the measurements of other nanostructures will also be discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomic-Resolution Imaging with a Sub-50-pm Electron Probe

Using a highly coherent focused electron probe in a fifth-order aberration-corrected transmission electron microscope, we report on resolving a crystal spacing less than 50 pm. Based on the geometrical source size and residual coherent and incoherent axial lens aberrations, an electron probe is calculated, which is theoretically capable of resolving an ideal 47 pm spacing with 29% contrast. Our experimental data show the 47 pm spacing of a Ge <114> crystal imaged with 11%-18% contrast at a 60%-95% confidence level, providing the first direct evidence for sub-50-pm resolution in annular dark-field scanning transmission electron microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct imaging of LaAlO{sub 3}/SrTiO{sub 3} nanostructures using piezoresponse force microscopy

The interface between LaAlO{sub 3} and TiO{sub 2}-terminated SrTiO{sub 3} can be switched between metastable conductive and insulating states using a conductive atomic force microscope probe. Determination of the nanoscale dimensions has previously required a destructive readout (e.g., local restoration of an insulating state). Here it is shown that high-resolution non-destructive imaging of conductive nanostructures can be achieved using a specific piezoresponse force microscopy (PFM) technique. Images of conductive and insulating nanoscale features are achieved with feature sizes as small as 30 nm. The measured nanowire width from PFM is well correlated with those obtained from nanowire erasure.

36 MATERIALS SCIENCE↗

Comparing Machine Learning and Physics-Based Nanoparticle Geometry Determinations Using Far-Field Spectral Properties

Anisotropic metal nanostructures exhibit polarization-dependent light scattering, a property which has been widely studied and exploited to determine orientations of subwavelength structures using far-field microscopy. Here we explore the use of variational autoencoders (VAEs) to determine the geometries of gold nanorods (NRs) such as in-plane orientation and aspect ratio under linearly polarized dark-field illumination in an optical microscope. We enforce a shared latent space to connect two VAEs trained separately with polarized dark-field scattering spectra and electron microscopy images and achieve image prediction (shape, orientation, and size) of Au NRs using only polarized dark-field scattering spectra. We determine the geometrical parameters of orientational angle and aspect ratio quantitatively via both our dual-VAE and physics-based analysis on the input scattering spectra. We show that orientational angle prediction by dual-VAE performs well with only a small (~300 particle) training set, yielding a mean absolute error (MAE) of 14.4° and a concordance correlation coefficient (CCC) of 0.95. This performance is only marginally worse than the physics-based cos(2?) fitting approach between the scattering intensity and the polarizing angle, which achieves MAE of 8.78° and CCC of 0.99. Aspect ratio determination is also comparable for the dual-VAE and physics-based fitting comparison (MAE of 0.21 vs. 0.23 and CCC of 0.53 vs. 0.68). Here, this dual encoder-decoder architecture effectively exploits the structure-property relationships of plasmonic nanostructures to construct a cross-modal machine learning (ML) approach, providing a pathway to employ ML approaches to address other structure-property relationships in materials science.

Dark-field scattering↗

Imaging local discharge cascades for correlated electrons in WS 2 /WSe 2 moiré superlattices

Transition metal dichalcogenide moiré heterostructures provide an ideal platform to explore the extended Hubbard model, where long-range Coulomb interactions play a critical role in determining strongly correlated electron states. This has led to experimental observations of Mott insulator states at half filling as well as a variety of extended Wigner crystal states at different fractional fillings. However, a microscopic understanding of these emerging quantum phases is still lacking. Here we describe a scanning tunnelling microscopy (STM) technique for the local sensing and manipulation of correlated electrons in a gated WS 2 /WSe 2 moiré superlattice, which enables the experimental extraction of fundamental extended Hubbard model parameters. We demonstrate that the charge state of the local moiré sites can be imaged by their influence on the STM tunnelling current. In addition to imaging, we are also able to manipulate the charge state of correlated electrons. When we ramp the bias on the STM tip, there is a local discharge cascade of correlated electrons in the moiré superlattice, which allows us to estimate the nearest-neighbour Coulomb interaction. Two-dimensional mapping of the moiré electron charge states also enables us to determine the on-site energy fluctuations at different moiré sites. Furthermore, our technique should be broadly applicable to many semiconductor moiré systems, offering a powerful tool for the microscopic characterization and control of strongly correlated states in moiré superlattices.

36 MATERIALS SCIENCE↗

Future of Electron Scattering and Diffraction

The ability to correlate the atomic- and nanoscale-structure of condensed matter with physical properties (e.g., mechanical, electrical, catalytic, and optical) and functionality forms the core of many disciplines. Directing and controlling materials at the quantum-, atomic-, and molecular-levels creates enormous challenges and opportunities across a wide spectrum of critical technologies, including those involving the generation and use of energy. The workshop identified next generation electron scattering and diffraction instruments that are uniquely positioned to address these grand challenges. The workshop participants identified four key areas where the next generation of such instrumentation would have major impact: A – Multidimensional Visualization of Real Materials B – Atomic-scale Molecular Processes C – Photonic Control of Emergence in Quantum Materials D – Evolving Interfaces, Nucleation, and Mass Transport Real materials are comprised of complex three-dimensional arrangements of atoms and defects that directly determine their potential for energy applications. Understanding real materials requires new capabilities for three-dimensional atomic scale tomography and spectroscopy of atomic and electronic structures with unprecedented sensitivity, and with simultaneous spatial and energy resolution. Many molecules are able to selectively and efficiently convert sunlight into other forms of energy, like heat and electric current, or store it in altered chemical bonds. Understanding and controlling such process at the atomic scale require unprecedented time resolution. One of the grand challenges in condensed matter physics is to understand, and ultimately control, emergent phenomena in novel quantum materials that necessitate developing a new generation of instruments that probe the interplay among spin, charge, orbital, and lattice degrees of freedom with intrinsic time- and length-scale resolutions. Molecules and soft matter require imaging and spectroscopy with high spatial resolution without damaging their structure. The strong interaction of electrons with matter allows high-energy electron pulses to gather structural information before a sample is damaged. Electron ScatteringImaging, diffraction, and spectroscopy are the fundamental capabilities of electron-scattering instruments. The DOE BES-funded TEAM (Transmission Electron Aberration-corrected Microscope) project achieved unprecedented sub-atomic spatial resolution in imaging through aberration-corrected transmission electron microscopy. To further advance electron scattering techniques that directly enable groundbreaking science, instrumentation must advance beyond traditional two-dimensional imaging. Advances in temporal resolution, recording the full phase and energy spaces, and improved spatial resolution constitute a new frontier in electron microscopy, and will directly address the BES Grand Challenges, such as to “control the emergent properties that arise from the complex correlations of atomic and electronic constituents” and the “hidden states” “very far away from equilibrium”. Ultrafast methods, such as the pump-probe approach, enable pathways toward understanding, and ultimately controlling, the chemical dynamics of molecular systems and the evolution of complexity in mesoscale and nanoscale systems. Central to understanding how to synthesize and exploit functional materials is having the ability to apply external stimuli (such as heat, light, a reactive flux, and an electrical bias) and to observe the resulting dynamic process in situ and in operando, and under the appropriate environment (e.g., not limited to UHV conditions). To enable revolutionary advances in electron scattering and science, the participants of the workshop recommended three major new instrumental developments: A. Atomic-Resolution Multi-Dimensional Transmission Electron Microscope: This instrument would provide quantitative information over the entire real space, momentum space, and energy space for visualizing dopants, interstitials, and light elements; for imaging localized vibrational modes and the motion of charged particles and vacancies; for correlating lattice, spin, orbital, and charge; and for determining the structure and molecular chemistry of organic and soft matter. The instrument will be uniquely suited to answer fundamental questions in condensed matter physics that require understanding the physical and electronic structure at the atomic scale. Key developments include stable cryogenic capabilities that will allow access to emergent electronic phases, as well as hard/soft interfaces and radiation- sensitive materials. B. Ultrafast Electron Diffraction and Microscopy Instrument: This instrument would be capable of nano-diffraction with 10 fs temporal resolution in stroboscopic mode, and better than 100 fs temporal resolution in single shot mode. The instrument would also achieve single- shot real-space imaging with a spatial/temporal resolution of 10 nm/10 ps, representing a thousand fold improvement over current microscopes. Such a capability would be complementary to x-ray free electron lasers due to the difference in the nature of electron and x-ray scattering, enabling space-time mapping of lattice vibrations and energy transport, facilitating the understanding of molecular dynamics of chemical reactions, the photonic control of emergence in quantum materials, and the dynamics of mesoscopic materials. C. Lab-In-Gap Dynamic Microscope: This instrument would enable quantitative measurements of materials structure, composition, and bonding evolution in technologically relevant environments, including liquids, gases and plasmas, thereby assuring the understanding of structure function relationship at the atomic scale with up to nanosecond temporal resolution. This instrument would employ a versatile, modular sample stage and holder geometry to allow the multi-modal (e.g., optical, thermal, mechanical, electrical, and electrochemical) probing of materials’ functionality in situ and in operando. The electron optics encompasses a pole piece that can accommodate the new stage, differential pumping, detectors, aberration correctors, and other electron optical elements for measurement of materials dynamics. To realize the proposed instruments in a timely fashion, BES should aggressively support research and development of complementary and enabling instruments, including new electron sources, advanced electron optics, new tunable specimen pumps and sample stages, and new detectors. The proposed instruments would have transformative impact on physics, chemistry, materials science, engineering

43 PARTICLE ACCELERATORS↗

Multiplexed single-molecule measurements with magnetic tweezers

We present a method for performing multiple single-molecule manipulation experiments in parallel with magnetic tweezers. We use a microscope with a low magnification, and thus a wide field of view, to visualize multiple DNA-tethered paramagnetic beads and apply an optimized image analysis routine to track the three-dimensional position of each bead simultaneously in real time. Force is applied to each bead using an externally applied magnetic field. Since variations in the field parameters are negligible across the field of view, nearly identical manipulation of all visible beads is possible. However, we find that the error in the position measurement is inversely proportional to the microscope's magnification. To mitigate the increased error caused by demagnification, we have developed a strategy based on tracking multiple fixed beads. Our system is capable of simultaneously manipulating and tracking up to 34 DNA-tethered beads at 60 Hz with {approx}1.5 nm resolution and with {approx}10% variation in applied force.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of tungsten phases formation during tungsten metal powder consolidation by FAST: Implications for high-temperature applications

Highlights: • Lowering the sintering temperature of W to 2173 K by using FAST. • Application of electron microscopy for microstructure characterisation. • W{sub 2}C shell formation due to C difussion from graphite tooling. • Identification of co-formed secondary phase, WO{sub 2}. • Influence of WO{sub 2} on high-thermal applications. - Abstract: Tungsten is a candidate material for the demonstration fusion power plant DEMO. To ensure high density and structural stability, Field-Assisted Sintering Technique (FAST) is proposed as a consolidation method. This study discusses the formation of phases during sintering of tungsten by the FAST. Scanning electron microscopy, X-ray diffraction and transmission electron microscopy were used to evaluate the microstructure in tungsten-based materials. The results of microscopic examinations revealed the in-situ formation of tungsten oxide and a formation of tungsten carbide shell around tungsten core. Tungsten carbide-rich shell is formed due to the carbon diffusion from the graphite die used in the FAST into tungsten at high temperatures. In contrast to easy removal of tungsten carbide shell by mechanical grinding, the formation of tungsten oxide in the W-matrix can influence the performance of such material when used as plasma-facing material in the fusion reactor. High-temperature experiments at 1873 K showed that tungsten-oxide phase starts to decompose, which results in material degradation and formation of voids and surface blisters.

36 MATERIALS SCIENCE↗

Electron optics for 4 MeV ultrafast electron microscope - Final Report

Calabazas Creek Research, Inc. (CCR), in collaboration with Northern Illinois University (NIU), proposed to leverage CCR’s experience in electron beam generation and focusing and NIU’s experience in electron microscopy to develop a 4 MeV UEM with sub-ns temporal resolution and 0.3 nm spatial resolution with a relative energy spread of 10-5. Important design tools for the program were CCR’s 3D, finite element code Beam Optics Analyzer (BOA) and the photocathode design code PHOTOQE. However, early in the program it became clear that information necessary to use PHOTOQE was not available, and the program focused on the modifying to BOA to provide the required functionality.

beam optics simulation↗

Noble gas ion beams in materials science for future applications and devices

Helium ion microscopy (HIM), enabled by a gas field ion source (GFIS), is an emerging imaging and nanofabrication technique compatible with many applications in materials science. The scanning electron microscope (SEM) has become ubiquitous in materials science for high-resolution imaging of materials. However, due to the fundamental limitation in focusing of electron beams, ion-beam microscopy is now being developed (e.g., at 20 kV the SEM beam diameter ranges from 0.5 to 1 nm, whereas the HIM offers 0.35 nm). The key technological advantage of the HIM is in its multipurpose design that excels in a variety of disciplines. The HIM offers higher resolution than the best available SEMs as well as the traditional gallium liquid-metal ion source (LMISs) focused ion beams (FIBs), and is capable of imaging untreated biological or other insulating samples with unprecedented resolution, depth of field, materials contrast, and image quality. GFIS FIBs also offer a direct path to defect engineering via ion implantation, three-dimensional direct write using gaseous and liquid precursors, and chemical-imaging options with secondary ion mass spectrometry. HIM covers a wide range of tasks that otherwise would require multiple tools or specialized sample preparation. In this paper, we describe the underlying technology, present materials, relevant applications, and offer an outlook for the potential of FIB technology in processing materials.

2D materials↗

Phase control of austenitic chrome-nickel steel

The paper presents the results of the comparative study of the possibilities of different structural and magnetic methods for detection and visualization of the strain-induced martensitic phase in low carbon austenitic chromium-nickel steel. Results of TEM, SEM, optical microscopy, atomic and magnetic force microscopy, and magnetic measurements are presented. Amount of the magnetic strain-induced martensite was estimated. We pioneered magnetic force microscopic images of the single domain cluster distribution of the strain-induced martensite in austenite-ferrite materials.

36 MATERIALS SCIENCE↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Investigation Into the Optimum Beam Shape and Fluence for Selective Ablation of Dental Calculus at lambda = 400 nm

A frequency-doubled Ti:sapphire laser is shown to selectively ablate dental calculus. The optimal transverse shape of the laser beam, including its variability under water-cooling, is determined for selective ablation of dental calculus. Intensity profiles under various water-cooling conditions were optically observed. The 400-nm laser was coupled into a multimode optical fiber using an f = 2.5-cm lens and light-shaping diffuser. Water-cooling was supplied coaxially around the fiber. Five human tooth samples (four with calculus and one pristine) were irradiated perpendicular to the tooth surface while the tooth was moved back and forth at 0.3 mm/second, varying between 20 and 180 iterations. The teeth were imaged before and after irradiation using light microscopy with a flashing blue light-emitting diode (LED). An environmental scanning electron microscope imaged each tooth after irradiation. High-order super-Gaussian intensity profiles are observed at the output of a fiber coiled around a 4-in. diameter drum. Super-Gaussian beams have a morehomogenous fluence distribution than Gaussian beams and have a higher energy efficiency for selective ablation. Coaxial water-cooling does not noticeably distort the intensity distribution within 1 mm from the optical fiber. In contrast, lasers focused to a Gaussian cross section (<=50-mm diameter) without fiber propagation and cooled by a water spray are heavily distorted and may lead to variable ablation. Calculus is preferentially ablated at high fluences (>= 2 J/cm^2); below this fluence, stalling occurs because of photo-bleaching of the calculus. Healthy dental hard tissue is not removed at fluences <=3 J/cm^2. Supplying laser light to a tooth using an optical fiber with coaxial water-cooling is determined to be the most appropriate method when selectively removing calculus with a frequency-doubled Ti:sapphire laser. Fluences over 2 J/cm^2 are required to remove calculus efficiently since photo-bleaching stalls calculus removal below that value.

calculus removal↗