Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Dehumidification via membrane separation for space-based applications

The paper describes the development of a membrane-based dehumidification process for space-based applications, such as spacecraft cabins and EVA space suits. Results presented are from: (1) screening tests conducted to determine the efficacy of various membranes to separate water vapor from air, and (2) parametric and long-term tests of membranes operated at conditions that simulate the range of environmental conditions (e.g., temperature and relative humidity) expected in the planned Space Station. Also included in this paper is a discussion of preliminary designs of membrane-based dehumidification processes for the Space Station and EVA space suits. These designs result in compact and energy-efficient systems that offer significant advantages over conventional dehumidification processes.

Gienger, Jane Kucera↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

Investigation of humidity control via membrane separation for advanced Extravehicular Mobility Unit (EMU) application

This paper describes the development of a membrane-based process for dehumidifying the Extravehicular Mobility Unit (EMU). The membrane process promises to be smaller, lighter, and more energy efficient than the other technologies for dehumidification. The dehydration membranes were tested for 90 days at conditions expected to be present in the EMU. The results of these tests indicate that membrane-based technology can effectively control humidity in the EMU.

Newbold, D. D.↗

Absence of first-order unbinding transitions of fluid and polymerized membranes

Unbinding transitions of fluid and polymerized membranes are studied by renormalization-group (RG) methods. Two different RG schemes are used and found to give rather consistent results. The fixed-point structure of both RG's exhibits a complex behavior as a function of the decay exponent tau for the fluctuation-induced interaction of the membranes. For tau greater than tau(S2) interacting membranes can undergo first-order transitions even in the strong-fluctuation regime. These estimates for tau(S2) imply, however, that both fluid and polymerized membranes unbind in a continuous way in the absence of lateral tension.

Grotehans, Stefan↗

The modeling of gas phase permeation through iron and nickel membranes

The gas phase permeation of hydrogen through metal membranes encompasses many kinetic processes. This paper reviews a permeation model which incorporates second order gas-surface reaction kinetics with simple bulk diffusion. The model is used to investigate the effect of this particular surface reaction of steady-state permeation. The dependence of the steady-state permeation flux on temperature, pressure, and thickness of the membrane has been calculated. The model predicts that the bulk controlled steady-state flux will change to a surface limited steady-state flux as either the temperature or thickness of the membrane is reduced. Finally, using independently derived parameters, the model is compared with permeation measurements on iron and nickel membranes.

Kuhn, David K.↗

Deflection And Stress In Preloaded Square Membrane

Theoretical analysis yields equations for transverse deflection of, and stresses in, square membrane subject to both uniform transverse load and tension preloads applied uniformly along the edges. Follows energy/virtual-displacement approach. Basic equation expresses strain energy in membrane as double integral, over x and y coordinates of square, of function of longitudinal strains, shear strain, thickness of membrane, and Young's modulus and Poissons's ratio of membrane material.

Hermida, Alfonso↗

NASA In-step: Permeable Membrane Experiment

Viewgraphs on the Permeable Membrane Experiment are presented. An experiment overview is given. The Membrane Phase Separation Experiment, Membrane Diffusion Interference Experiment, and Membrane Wetting Experiment are described. Finally, summary and conclusions are discussed.

Source record↗

Evaporative Cooling Membrane Device

An evaporative cooling membrane device is disclosed having a flat or pleated plate housing with an enclosed bottom and an exposed top that is covered with at least one sheet of hydrophobic porous material having a thin thickness so as to serve as a membrane. The hydrophobic porous material has pores with predetermined dimensions so as to resist any fluid in its liquid state from passing therethrough but to allow passage of the fluid in its vapor state, thereby, causing the evaporation of the fluid and the cooling of the remaining fluid. The fluid has a predetermined flow rate. The evaporative cooling membrane device has a channel which is sized in cooperation with the predetermined flow rate of the fluid so as to produce laminar flow therein. The evaporative cooling membrane device provides for the convenient control of the evaporation rates of the circulating fluid by adjusting the flow rates of the laminar flowing fluid.

Lomax, Curtis↗

Membrane-Based Functions in the Origin of Cellular Life

Our objective is to help explain how the earliest ancestors of contemporary cells (protocells) performed their essential functions employing only the molecules available in the protobiological milieu. Our hypothesis is that vesicles, built of amphiphilic, membrane-forming materials, emerged early in protobiological evolution and served as precursors to protocells. We further assume that the cellular functions associated with contemporary membranes, such as capturing and, transducing of energy, signaling, or sequestering organic molecules and ions, evolved in these membrane environments. An alternative hypothesis is that these functions evolved in different environments and were incorporated into membrane-bound structures at some later stage of evolution. We focus on the application of the fundamental principles of physics and chemistry to determine how they apply to the formation of a primitive, functional cell. Rather than attempting to develop specific models for cellular functions and to identify the origin of the molecules which perform these functions, our goal is to define the structural and energetic conditions that any successful model must fulfill, therefore providing physico-chemical boundaries for these models. We do this by carrying out large-scale, molecular level computer simulations on systems of interest.

Chipot, Christophe↗

Influence of Solutocapillary Convection on Macrovoid Defect Formation in Polymeric Membranes

Macrovoids (MVs) are large (10-50 micrometers) pores often found in polymeric membranes prepared via phase-inversion techniques. They are generally considered undesirable, as they adversely affect the permeability properties and performance of polymeric membranes for microfiltration, ultrafiltration, and reverse osmosis. However, MVs can be useful in certain thin-film applications in which vapor transmission is necessary, or for use as reservoirs for enzymes or liquid membrane material. If more could be learned about the nature and causes of MV formation, it might be possible to devise techniques to control and/or prevent MV formation that are more effective than those currently employed. Two hypotheses for the MV growth mechanism have been advanced. Reuvers proposed that once initiated, MV growth can be attributed to diffusion of (primarily) solvent to the MV nuclei. Because this mechanism does not involve gross movement of the MV, the presence or absence of body forces such as buoyancy should not significantly affect MV growth. On the other hand, Shojaie et al. proposed that solutocapillary convection induced by a steep surface-tension gradient along the MV/bulk solution interface enhances mass transfer to the growing MV. This interfacial convection exerts a force that pulls the growing MV downward into the casting solution. Both buoyancy and viscous drag hinder MV growth by inhibiting this motion. Thus, removing the buoyancy force by casting in microgravity should augment MV growth according to this hypothesis. Whereas neither surface tension nor gravity has a significant effect on MV growth according to the first hypothesis, buoyancy forces should be important if the second hypothesis is correct. The overall goal of this research is to test these two hypotheses in order to improve our understanding of the MV growth processing solvent-cast polymeric membranes. Studying MV growth in low-gravity conditions is pivotal to our ability to discriminate between these two hypotheses.

Pekny, M. R.↗

Membrane Vibration Studies Using a Scanning Laser Vibrometer

This paper summarizes on-going experimental work at NASA Langley Research Center to measure the dynamics of a 1.016 m (40 in.) square polyimide film Kapton membrane. A fixed fully automated impact hammer and Polytec PSV-300-H scanning laser vibrometer were used for non-contact modal testing of the membrane with zero-mass-loading. The paper discusses the results obtained by testing the membrane at various tension levels and at various excitation locations. Results obtained by direct shaker excitation to the membrane are also discussed.

Gaspar, James L.↗

Membrane Separation Processes at Low Temperatures

The primary focus of Kennedy Space Center's gas separation activities has been for carbon dioxide, nitrogen, and argon used in oxygen production technologies for Martian in-situ resource utilization (ISRU) projects. Recently, these studies were expanded to include oxygen for regenerative life support systems. Since commercial membrane systems have been developed for separation of carbon dioxide, nitrogen, and oxygen, initially the studies focused on these membrane systems, but at lower operating temperatures and pressures. Current investigations art examining immobilized liquids and solid sorbents that have the potential for higher selectivity and lower operating temperatures. The gas separation studies reported here use hollow fiber membranes to separate carbon dioxide, nitrogen, and argon in the temperature range from 230 to 300 K. Four commercial membrane materials were used to obtain data at low feed and permeate pressures. These data were used with a commercial solution-diffusion modeling tool to design a system to prepare a buffer gas from the byproduct of a process to capture Martian carbon dioxide. The system was designed to operate, at 230 K with a production rate 0.1 sLpm; Feed composition 30% CO2, 44% N2, and 26% Ar; Feed pressure 104 kPa (780); and Permeate pressure 1 kPa (6 torr); Product concentration 600 ppm CO2. This new system was compared with a similar system designed to operate at ambient temperatures (298 K). The systems described above, along with data, test apparatus, and models are presented.

Parrish, Clyde↗

Peptides at Membrane Surfaces and their Role in Prebiotic Evolution

Protocells had to transport ions and organic matter across membranes separating the interior of the cell from the environment, capture and utilize energy and transduce environmental signals. In a series of detailed, molecular-level computer simulations we show how these peptides in contact with membranes can acquire ordered structures and functions. We have investigated the stability of a simple alpha-helical peptide containing Leucine (L) and Serine (S) of the form (LSLLLSL)3 in a model membrane system. The parallel in-plane state is the most stable configuration. The transmembrane state is metastable, and about 15 kcal/mol is required to insert the peptide into the membrane. We investigated dimes of both (LSLLLSL)3 and glycophorin A, and show how the free energy of helix association can, at least partially, offset the free energy of insertion. We have also investigated the transmembrane pore of the influenza M2 protein. This aggregate of four identical alpha-helices, each built of 25 amino acids, forms an efficient and selective voltage-gated proton channel. Our simulations explain the gating mechanism, which can involve strands of hydrogen-bonded water through the pore or proton transfer through tautomerization of protein residues. The channel can be re-engineered to act as a simple proton pump.

Pohorille, Andrew↗

Compositionally-Graded Shape Memory Film for Self-Deployment of Membrane Reflectors and Optics

The next generation of space systems will require large apertures in order to image faint targets or cover large areas of Earth. These large apertures must be able to fit inside a launch vehicle fairing, be light enough for launch into orbit, and deploy on orbit with repeatability and reliability. The current state-of-the-art in flight optics is represented by the 4 meter LAMP telescope, with an areal density of 10 km sq m. Development of a Beryllium mirror demonstration article for NGST (Next Generation Space Telescope) at the University of Arizona indicate areal densities of 0.5 kg sq m with flight hardware in the 12 meter range. With progressive improvements in existing deployment, packaging, and structural technologies, the size of optics and reflectors will continue to increase, while mass is reduced. However, without a breakthrough in materials, packaging and/or deployment technologies, the goal for Gossamer structures of 0.1 kg sq m is unachievable for the near and mid-term NASA missions. Membrane technology provides the best hope of achieving such low areal densities. In combination with advances in membrane materials and structures, development of revolutionary techniques for deployment systems can provide significant improvements in large aperture technology. In this paper, the results of a six-month Phase I research effort to demonstrate the application of thin film NiTi to aerospace-qualified membrane and mesh materials are presented. Deposition of shape memory thin film was achieved Astromesh (trademark) metal mesh and CP-1, and optical-quality polymer membrane. Not only was full-coating deposition demonstrated, but also small segment deposition which holds potential for local surface control. Deployment of these materials was also demonstrated, setting the stage for the development of a larger test article.

Hill, Lisa↗

Microwave-Driven Multifunctional Capability of Membrane Structures

A large, ultra lightweight space structure, such as solar sails and Gossamer spacecrafts, requires a distributed power source to alleviate wire networks, unlike the localized on-board power infrastructures typically found in most small spacecrafts. The concept of microwave-driven multifunctional capability for membrane structures is envisioned as the best option to alleviate the complexity associated with hard-wired control circuitry and on-board power infrastructures. A rectenna array based on a patch configuration for high voltage output was developed to drive membrane actuators, sensors, probes, or other devices. Networked patch rectenna array receives and converts microwave power into a DC power for an array of smart actuators. To use microwave power effectively, the concept of a power allocation and distribution (PAD) circuit is adopted for networking a rectenna/actuator patch array. The use of patch rectennas adds a significant amount of rigidity to membrane flexibility and they are relatively heavy. A dipole rectenna array (DRA) appears to be ideal for thin-film membrane structures, since DRA is flexible and light. Preliminary design and fabrication of PAD circuitry that consists of a few nodal elements were made for laboratory testing. The networked actuators were tested to correlate the network coupling effect, power allocation and distribution, and response time.

Choi, Sang H.↗

Macrovoid Defect Growth during Evaporative Casting of Polymeric Membranes

Macrovoid (MV) formation is a significant problem in evaporatively cast polymeric membranes. MVs are large, elongated or teardrop-shaped pores (~10-50 micron) that can impair membrane structural integrity. Although MVs have been extensively studied, there is no general agreement on the mechanisms governing MV growth. Recently, our research group has formulated the solutocapillary convection (SC) hypothesis, which contends that MV growth involves three principal forces: a Marangoni force generated by surface tension gradients within the MV interface, a viscous drag force, and a gravitationally induced body force. Two sets of complementary experiments were conducted to test the SC hypothesis. Ground-based videomicroscopy flow-visualization (VMFV) was utilized to measure the flow velocities at the MV-casting solution interface and deep within the casting solution. The measurements were performed with casting solutions containing 10 wt% cellulose acetate (CA), 30 wt% H2O, 60 wt% acetone, and 200- ppm TiO2 particles for flow visualization, and the surface tension was controlled by surfactant addition. Qualitatively, the experiments indicated that MV growth occurs in three distinct phases: (1) a very rapid initial growth period, (2) a much slower growth phase, and (3) absorption of selected MVs into the expanding demixed region. The presence of tracer particles inside the MVs suggests the presence of a convective flow, which transfers the particles from the bulk solution to the MV interior. Although the VMFV experiments did not establish any surfactant effect on the interfacial velocities, a statistically significant effect on the MV number density was observed. In the second set of experiments, membranes were cast aboard a KC-135 aircraft under 0-g and 2-g conditions. Despite careful attention to the design and fabrication of the membrane casting apparatus (MCA), several problems were encountered, the most significant of which was the contamination of the casting solution by the activated carbon particles used for solvent absorption.

Greenberg, A. R.↗

Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove non-condensed gases (NCG) from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the NCG. The inner hydrophobic fiber allows the trapped NCG to pass through and vent to the ambient atmosphere in the cabin. The purpose of the gas trap is to prevent gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump, and the current gas trap has performed flawlessly in this regard. However, because of actual operational conditions on-orbit, its gas removal performance and operational lifetime have been affected. This paper discusses experiences with several of these dual- membrane gas traps, including on-orbit gas venting rate, effects due to the presence of nickel in the ITCS coolant, and subsequent refurbishing to remove the nickel from the gas trap.

Leimkuehler, Thomas O.↗

Toward Effective Shell Modeling of Wrinkled Thin-Film Membranes Exhibiting Stress Concentrations

Geometrically nonlinear shell finite element analysis has recently been applied to solar-sail membrane problems in order to model the out-of-plane deformations due to structural wrinkling. Whereas certain problems lend themselves to achieving converged nonlinear solutions that compare favorably with experimental observations, solutions to tensioned membranes exhibiting high stress concentrations have been difficult to obtain even with the best nonlinear finite element codes and advanced shell element technology. In this paper, two numerical studies are presented that pave the way to improving the modeling of this class of nonlinear problems. The studies address the issues of mesh refinement and stress-concentration alleviation, and the effects of these modeling strategies on the ability to attain converged nonlinear deformations due to wrinkling. The numerical studies demonstrate that excessive mesh refinement in the regions of stress concentration may be disadvantageous to achieving wrinkled equilibrium states, causing the nonlinear solution to lock in the membrane response mode, while totally discarding the very low-energy bending response that is necessary to cause wrinkling deformation patterns. An element-level, strain-energy density criterion is suggested for facilitating automated, adaptive mesh refinements specifically aimed at the modeling of thin-film membranes undergoing wrinkling deformations.

Tessler, Alexander↗