Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Estimating the in situ sediment-porewater distribution of PAHs and chlorinated aromatic hydrocarbons in anthropogenic impacted sediments

It has become increasingly apparent that the in situ sediment-porewater distribution behavior of organic compounds within anthropogenic impacted sediments is quite diverse, and challenging to generalize. Traditional models based on octanol-water partitioning generally overestimate native porewater concentrations, and modern approaches accounting for multiple carbon fractions, including black carbon, appear sediment specific. To assess the diversity of this sorption behavior, we collected all peer-reviewed total organic carbon (TOC)-normalized in situ sediment-porewater distribution coefficients, K{sub TOC}, for impacted sediments. This entailed several hundreds of data for PAHs, PCBs, PCDD/Fs, and chlorinated benzenes, covering a large variety of sediments, locations, and experimental methods. Compound-specific KTOC could range up to over 3 orders of magnitude. Output from various predictive models for individual carbonaceous phases found in impacted sediments, based on peer-reviewed polyparameter linear free energy relationships (PP-LFERs), Raoult's Law, and the SPARC online-calculator, were tested to see if any of the models could consistently predict literature K{sub TOC} values within a factor of 30 (i.e. about 1.5 orders of magnitude, or half the range of K{sub TOC} values). The Raoult's Law model and coal tar PP-LFER achieved the sought-after accuracy for all tested compound classes, and are recommended for general, regional-scale modeling purposes. As impacted sediment-porewater distribution models are unlikely to get more accurate than this, this review underpins that the only way to accurately obtain accurate porewater concentrations is to measure them directly, and not infer them from sediment concentrations. 86 refs., 2 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Measured values of coal mine stopping resistance

As coal mines become larger, the number of stoppings in the ventilation system increases. Each stopping represents a potential leakage path which must be adequately represented in the ventilation model. Stopping resistance can be calculated using two methods, the USBM method, used to determine a resistance for a single stopping, and the MVS technique, in which an average resistance is calculated for multiple stoppings. Through MVS data collected from ventilation surveys of different subsurface coal mines, average resistances for stoppings were determined for stopping in poor, average, good, and excellent conditions. The calculated average stoppings resistance were determined for concrete block and Kennedy stopping. Using the average stopping resistance, measured and calculated using the MVS method, provides a ventilation modeling tool which can be used to construct more accurate and useful ventilation models. 3 refs., 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Analysis and methodology for measuring oxygen concentration in liquid sodium with a plugging meter

Oxygen concentration in liquid sodium is a critical measurement in assessing the potential for corrosion damage in sodium-cooled fast reactors (SFRs). There has been little recent work on sodium reactors and oxygen detection. Thus, the technical expertise dealing with oxygen measurements within sodium is no longer readily available in the U.S. Two methods of oxygen detection that have been investigated are the plugging meter and the galvanic cell. One of the overall goals of the Univ. of Wisconsin's sodium research program is to develop an affordable, reliable galvanic cell oxygen sensor. Accordingly, attention must first be dedicated to a well-known standard known as a plugging meter. Therefore, a sodium loop has been constructed on campus in effort to develop the plugging meter technique and gain experience working with liquid metal. The loop contains both a galvanic cell test section and a plugging meter test section. Consistent plugging results have been achieved below 20 [wppm], and a detailed process for achieving effective plugging has been developed. This paper will focus both on an accurate methodology to obtain oxygen concentrations from a plugging meter, and on how to easily control the oxygen concentration of sodium in a test loop. Details of the design, materials, manufacturing, and operation will be presented. Data interpretation will also be discussed, since a modern discussion of plugging data interpretation does not currently exist. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Region Three Aerial Measurement System Flight Planning Tool - 12006

The Region 3 Aerial Measurement System Flight Planning Tool is used by the National Nuclear Security Agency (NNSA), United States Department of Energy, Radiological Assistance Program, Region 3, to respond to emergency radiological situations. The tool automates the flight planning package process while decreasing Aerial Measuring System response times and decreases the potential for human error. Deployment of the Region Three Aerial Measurement System Flight Planning Tool has resulted in an immediate improvement to the flight planning process in that time required for mission planning has been reduced from 1.5 hours to 15 minutes. Anecdotally, the RAP team reports that the rate of usable data acquired during surveys has improved from 40-60 percent to over 90 percent since they began using the tool. Though the primary product of the flight planning tool is a pdf format document for use by the aircraft flight crew, the RAP team has begun carrying their laptop computer on the aircraft during missions. By connecting a Global Positioning System (GPS) device to the laptop and using ESRI ArcMap's GPS tool bar to overlay the aircraft position directly on the flight plan in real time, the RAP team can evaluate and correct the aircraft position as the mission is executed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a potassium filled UO{sub 2} core in a beryllium-reflected space reactor - 14371

The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965[1,2] have been evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and were determined to be acceptable benchmark experiments and are included in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook)[3]. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study 'power plants for the production of electrical power in space vehicles'.[4] The third configuration in this series of experiments was a beryllium-reflected mockup of a stainless-steel-clad, highly enriched uranium (HEU)-O{sub 2} fuel, potassium-cooled, space power reactor. Reactivity measurements, cadmium ratio spectral measurements, and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for the International Reactor Physics Experiment Evaluation Project (IRPhEP) and are published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook)[5]. More recently, two additional critical configurations have been evaluated and added to the existing evaluation report in the ICSBEP Handbook. The new critical configurations measure the effect of filling the core with potassium. The critical configuration consisted of 30.48 cm tall fuel tubes of 93.15 wt.% enriched uranium dioxide (UO{sub 2}) pellets. Each fuel tube had 26 pellets with a total mass of 295.8 g UO{sub 2} per tube. There were 253 tubes were arranged with 1.506-cm center-to-center, triangular spacing and surrounded on all side by a beryllium reflected. The reactivity of the system was measured with the core tank empty and filled with potassium. The system reactivity was increased from 13.4 c to 32 c. This change in system reactivity represents the worth of the potassium. Simple benchmark models for the empty and potassium filled cores have been derived and evaluated and found to be acceptable as benchmark experiments. The benchmark experiment eigenvalues are 1.0001 ± 0.0008 and 1.0011 ± 0.0009 for the empty and filled cores, respectively. When calculated with MCNP5 and ENDF/B-VII.0 the calculated eigenvalues are 0.98906 ± 0.00002 and 0.98883 ± 0.00002, respectively. These results are concerning due to the drop of the calculated system reactivity when potassium is added to the system rather than the expected increase in system reactivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures - Master's Thesis Presentation University of Idaho

Presentation for master's work at University of Idaho discussing Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures. Presentation covers slight literature review results/previous work, discussions on system design and approach for thermal property measurement of SiC composite and Tin system, modeling efforts, and results.

36 - MATERIALS SCIENCE↗

Surface Roughness Characterization of Niobium Subjected to Incremental BCP and EP Processing Steps

The surface of niobium samples polished under incremental Buffered Chemical Polish (BCP) and Electro-Polishing (EP) have been characterized through Atomic Force Microscopy (AFM) and stylus profilometry across a range of length of scales. The results were analyzed using Power Density Spectral (PSD) technique to determine roughness and characteristic dimensions. This study has shown that the PSD method is a valuable tool that provides quantitative information about surface roughness at different length scales.

36 MATERIALS SCIENCE↗

VARIATIONS IN REPRODUCTIVE TOXICANT IDENTIFICATION

Reproductive toxicants are a very important class of compounds. They present unique hazards to those of child bearing ages, perform their 'dirty work' using a wide variety of mechanisms on a number of different organs, and are regulatorily important. Because of all of this, properly identifying reproductive toxicants is important, but fraught with difficulty. In this paper we will describe types or reproductive toxicants, their importance, and both mistakes and good practices that people who are not experts in reproductive toxicology may use in their attempts to identify them. Additionally, this paper will focus on chemical reproductive toxicants and will not address biological agents that could affect reproductive toxicity although many principles outlined here could be applied to that endeavor.

59 BASIC BIOLOGICAL SCIENCES↗

Jet penetration into a riser operated in dense suspension upflow: experimental and model comparisons

Solids tracers were used to characterize the penetration of a gas-solids jet directed toward the center of the 0.3-m diameter, circulating fluidized bed (CFB) riser. The penetration was measured by tracking phosphorescent particles illuminated immediately prior to injection into the riser. Photosensors and piezoelectric detectors were traversed across the radius of the riser at various axial positions to detect the phosphorescent jet material and particles traveling in the radial direction. Local particle velocities were measured at various radial positions, riser heights, and azimuthal angles using an optical fiber probe. Four (4) variables were tested including the jet velocity, solids feed rate into the jet, the riser velocity, and overall CFB circulation rate over 8 distinct test cases with the central, or base case, repeated each time the test series was conducted. In addition to the experimental measurements made, the entire riser with a side feed jet of solids was simulated using the Eulerian-Eulerian computer model MFIX.

42 ENGINEERING↗

Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, <5 mm, the electric field-lines tend to bend away from the side surfaces (i.e., a focusing effect). In thick detectors, >1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗