Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Development of Chemical Procedures for Isotope Harvesting: Separation of Trace Hafnium from Tungsten

The separation of trace hafnium from bulk tungsten alloys is of interest for isotope harvesting at the National Superconducting Cyclotron Laboratory and the Facility for Rare Ion Beams because 172 Hf, the parent of 172 Lu, accumulates in tungsten alloy beam blockers at these facilities. In this work, a procedure for the separation of trace hafnium from a bulk tungsten alloy (454 g) was established using tracer isotopes ( 175 Hf, 88 Zr, 173 Lu, and 88 Y). Here, the procedure employed dissolution in an HF–HNO 3 solution followed by a calcium fluoride precipitation, and then extraction chromatography was used for more selective separation steps. Two stages of column separations using LN resin (HDEHP based) and TRU resin (CMPO based) were performed. Gamma-ray spectroscopy and mass spectrometry were used to analyze the final hafnium sample and follow the steps in the chemical processing. Furthermore, the final recovery of hafnium was high (90 ± 8)%, and the mass of tungsten and other transition metals was reduced to near background levels (as determined by ICP-MS of the blank acid solutions). Zirconium follows hafnium quantitatively in this procedure; there was no detectable 173 Lu in the final hafnium sample.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SF6 Negative Ion Formation in Charge Transfer Experiments

In the present work, we report an update and extension of the previous ion-pair formation study of Hubers, M.M.; Los, J. Chem. Phys. 1975, 10, 235–259, noting new fragment anions from time-of-flight mass spectrometry. The branching ratios obtained from the negative ions formed in K + SF6 collisions, in a wide energy range from 10.7 up to 213.1 eV in the centre-of-mass frame, show that the main anion is assigned to SF5− and contributing to more than 70% of the total ion yield, followed by the non-dissociated parent anion SF6− and F−. Other less intense anions amounting to <20% are assigned to SF3− and F2−, while a trace contribution at 32u is tentatively assigned to S− formation, although the rather complex intramolecular energy redistribution within the temporary negative ion is formed during the collision. An energy loss spectrum of potassium cation post-collision is recorded showing features that have been assigned with the help of theoretical calculations. Quantum chemical calculations for the lowest-lying unoccupied molecular orbitals in the presence of a potassium atom are performed to support the experimental findings. Apart from the role of the different resonances participating in the formation of different anions, the role of higher-lying electronic-excited states of Rydberg character are noted.

Biochemistry & Molecular Biology↗

ENVnet provides a global molecular resource of dissolved organic matter

Dissolved organic matter (DOM) is an important component of Earth's carbon cycle and one of the planet's most chemically diverse pools, yet the molecular structures of its constituents remain largely unresolved. This limitation has hindered our ability to link DOM composition to microbial processes and ecosystem function. Here we present ENVnet, a global molecular repository built from tandem mass spectrometry data collected across 13 terrestrial and aquatic environment types, including 419 newly generated samples that expand publicly available DOM metabolomics data and cover previously underrepresented environments. By computationally deconvolving chimeric mass spectra, a longstanding challenge in environmental metabolomics, we recover high-quality fragmentation data for >22,000 distinct molecular features (defined by a specific precursor mass and fragmentation pattern). Using ENVnet, we uncover conserved and environment-specific molecular patterns in DOM composition and underlying biogeochemical processes. We also use molecular features encoded in ENVnet to train predictive models of DOM persistence, allowing molecular-level assessment of microbial turnover in independent systems.

54 ENVIRONMENTAL SCIENCES↗

Agilent AgileBioFoundry CRADA

NTESS, LBNL, PNNL, and Agilent are collaborating to expand a prototype system that processes hundreds of samples per day by UHPLC-QTOF mass spectrometric-based target methods for both metabolomic and proteomic application sin support the needs of strain optimization. Extending this technology to targeted triple quadrupole and drift tube ion mobility spectrometry mass spectrometric analyses offers direct advantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

r-Process Radioisotopes from Near-Earth Supernovae and Kilonovae

The astrophysical sites where r-process elements are synthesized remain mysterious: it is clear that neutron star mergers (kilonovae (KNe)) contribute, and some classes of core-collapse supernovae (SNe) are also possible sources of at least the lighter r-process species. The discovery of 60Fe on the Earth and Moon implies that one or more astrophysical explosions have occurred near the Earth within the last few million years, probably SNe. Intriguingly, 244 Pu has now been detected, mostly overlapping with 60 Fe pulses. However, the 244 Pu flux may extend to before 12 Myr ago, pointing to a different origin. Here, motivated by these observations and difficulties for r-process nucleosynthesis in SN models, we propose that ejecta from a KN enriched the giant molecular cloud that gave rise to the Local Bubble, where the Sun resides. Accelerator mass spectrometry (AMS) measurements of 244 Pu and searches for other live isotopes could probe the origins of the r-process and the history of the solar neighborhood, including triggers for mass extinctions, e.g., that at the end of the Devonian epoch, motivating the calculations of the abundances of live r-process radioisotopes produced in SNe and KNe that we present here. Given the presence of 244 Pu, other r-process species such as 93 Zr, 107 Pd, 129 I, 135 Cs, 182 Hf, 236 U, 237 Np, and 247 Cm should be present. Their abundances and well-resolved time histories could distinguish between the SN and KN scenarios, and we discuss prospects for their detection in deep-ocean deposits and the lunar regolith. We show that AMS 129 I measurements in Fe–Mn crusts already constrain a possible nearby KN scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗

Characterization of the biofilm landscape of Bacillus subtilis by spatial microproteomics

Bulk proteomics has been demonstrated to differentiate subpopulations within bacterial colonies, yet advanced analyses by mass spectrometry imaging (MSI) hold even greater promise for the future. This technology can enable high-throughput spatial phenotyping that can reshape biological discovery by providing visualization of components of various biomolecular mechanisms. With high mass resolving power and high spatial resolution analyses being routine, we can confidently enable intact protein imaging directly from samples with minimal preparation. Pairing those analyses with bulk experimental libraries can provide high confidence in annotations of post-translational modifications (PTMs) and truncations. Revealing PTM localization within the samples unlocks a direct window into unknown biology at the microscale. However, top-down proteomics (TDP) is not commonplace for microbial species, largely due to challenges in identifying detected peptides and proteins; considering the theoretical proteome of even the well-studied model bacterium Bacillus subtilis was only partially mapped recently. With little still known about the form and function of many of these proteins – let alone proteoforms, where PTMs and truncations of the same protein may possess unique physiological roles – there is a wealth of work to be done. Here we jointly apply TDP and MSI to describe the microscale spatial proteomic landscape within B. subtilis and further demonstrate the feasibility of detecting differentiated subpopulations through proteoforms across the biofilm landscape.

bacterial biofilms↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Industrializable interlayer with catalytic conversion of dead lithium for Ah–level Nickel–rich lithium metal batteries

The growth of lithium (Li) dendrites and the accumulation of dead Li (i.e., Li metal regions which are electronically disconnected from the current collector) significantly undermine the safety and performance of Li metal batteries. This study employs kilogram-scale atomic layer deposition technology to construct zinc oxide with a preferential (002) crystal orientation, which homogeneously forms on commercial carbon nanotube papers. Our approach emphasizes the importance of achieving a moderate Li adsorption energy and low Li migration energy barriers to suppress Li dendrite growth. In this work, we introduce the concept of "catalytic" effect for dead Li reconversion, as validated through time-of-flight secondary ion mass spectrometry, leading to a Li plating/stripping efficiency of 99.89%. The Ah-level Li metal pouch cells with high-nickel positive electrodes achieve a specific energy of 380 Wh kg -1 (based on the mass of the whole pouch cell) and demonstrate stable cycling under demanding conditions. Analysis of the cycled pouch cells confirms the structural integrity and provides insights into the mechanism of the dead Li "catalytic" conversion.

Shen, Huasen [Jianghan University, Wuhan (China)]↗

Developing High-Flux Ion Soft Landing with Mass-Selection for Improved Cryo-Electron Microscopy

The goal of this project is to redesign and repurpose existing high-flux ion soft-landing (SL) instrumentation developed at PNNL for new structural biology applications by integrating SL, mass-selection/separation of high mass-to-charge species, native mass spectrometry (MS), and cryo-electron microscopy (EM) to generate a workflow enabling structural and functional annotation of proteins and other complex biological samples. Ultimately, this work will result in a new instrument for mass-selection and SL based cryo-EM sample preparation and potentially increase the impact of PNNL and the broader microscopy community through commercial licensing.

47 OTHER INSTRUMENTATION↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

IsoForma: An R Package for Quantifying and Visualizing Positional Isomers in Top-Down LC-MS/MS Data

Proteoforms, the different forms of a protein with sequence variations including post-translational modifications (PTMs), execute vital functions in biological systems such as cell signaling and epigenetic regulation. Precisely defining the stoichiometry of PTMs has been challenging because, in the widely used bottom-up proteomics methods, the detection occurs at the peptide level and thus the link between peptides and their specific modification site is lost, resulting in proteoform ambiguity. Advances in top-down mass spectrometry (MS) technology have permitted the direct characterization of intact proteoforms and their exact number of modification sites, allowing for the relative quantification of positional isomers (PI). Proteins with positional isomers refers to proteoforms with identical total mass and set of modifications but varying PTM site combinations. The relative abundance of PI can be estimated by matching proteoform-specific fragment ions to top-down tandem MS (MS2) data to localize and quantify modifications. However, current approaches heavily rely on manual annotation. Here, we present IsoForma, an open-source R package for relative quantification of PI within a single tool. We benchmarked IsoForma’s performance against two existing workflows and highlight the similarity of the results and improvements in speed. Overall, IsoForma provides a streamlined process, reduces the time of conducting isoform-based analyses, and offers an essential framework for developing customized proteoform analysis workflows. Finally, the software is open source and available at https://github.com/EMSL-Computing/isoforma-lib.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Pyrolysis of high-density polyethylene: Degradation behaviors, kinetics, and product characteristics

Pyrolysis is a promising technology for converting plastic waste into valuable raw materials while offering a potential solution to the global plastic pollution crisis. In this study, the thermal pyrolysis of high-density polyethylene (HDPE) is investigated in a drop tube reactor under nearly isothermal conditions. The impact of reaction temperature and gas/volatile residence time on carbon conversion and product distribution is examined across a range of 500–900°C and 3.6–32.2s, respectively. Non-condensable gas products detected by online mass spectrometry are H 2 , CH 4 , C 2 H 4 , C 2 H 6 , C 3 H 6 , and C 3 H 8 . At elevated temperatures and prolonged residence time, H 2 yield reaches as high as 8.6 wt% of the initial HDPE mass due to intensified cracking reactions of C 2 –C 3 hydrocarbons and long-chain aliphatic compounds. Consequently, pyrolysis tars consist mainly of polycyclic aromatic hydrocarbons (PAHs) with 5–7 rings, accompanied by visible coke deposition within the reactor. HDPE decomposition to volatiles is an endothermic process and it is complete at a temperature between 492°C and 525°C, depending on the heating rate employed, from non-isothermal thermogravimetric analysis and differential scanning calorimetry (TGA-DSC) measurements. The thermal degradation of HDPE pellets follows the two-dimensional nucleation growth model for conversion levels up to 0.8 with an apparent activation energy of 259–270 kJ/mol and a pre-exponential factor of 4.83 × 10 17 –1.37 × 10 19 min -1 , determined from various isoconversional methods such as Flynn-Wall-Ozawa (FWO), Kissinger-Akahira-Sunose (KAS), and Starink, along with Criado's master plots. Further, these findings provide valuable insights into optimizing process parameters and refining reactor design for pyrolysis, which can be integrated with gasification and reforming processes to enhance hydrogen production on a larger scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Polymer Characterization: Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry encodes structural information across diverse homo- and copolymer ensembles, yet decrypting these spectra requires a systematic analytical approach. We introduce Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)─a general cipher algorithm that applies modular arithmetic to filter monomer-derived mass contributions and cluster MALDI peaks by nonconstitutional repeating units (non-CRUs). MOSAIC performs sequential modular operations using monomer mass differences as base units to compress complex spectral data, revealing end-group distributions and comonomer incorporation. As a demonstration, we applied MOSAIC to five copolymers formed by two different polymerization mechanisms. Furthermore, the resulting remainder–mass plots clearly resolve polymer homologs with distinct non-CRUs into visually apparent clusters, enabling intuitive assignment of mass spectral features.

Wang, Hanlin M. [University of Illinois at Urbana−↗