Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers

Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields, and when electrically active, respond with their own magnetic fields with attributes dependent upon the magnitude of the physical quantity being measured. A magnetic field response recorder powers and interrogates the magnetic sensors [see Magnetic-Field-Response Measurement- Acquisition System, NASA Tech Briefs Vol. 30, No, 6 (June 2006, page 28)]. Electrically conductive containers have low transmissivity for radio frequency (RF) energy and thus present problems for magnetic field response sensors. It is necessary in some applications to have a magnetic field response sensor s capacitor placed in these containers. Proximity to conductive surfaces alters the inductance and capacitance of the sensors. As the sensor gets closer to a conductive surface, the electric field and magnetic field energy of the sensor is reduced due to eddy currents being induced in the conductive surface. Therefore, the capacitors and inductors cannot be affixed to a conductive surface or embedded in a conductive material. It is necessary to have a fixed separation away from the conductive material. The minimum distance for separation is determined by the desired sensor response signal to noise ratio. Although the inductance is less than what it would be if it were not in proximity to the conductive surface, the inductance is fixed. As long as the inductance is fixed, all variations of the magnetic field response are due to capacitance changes. Numerous variations of inductor mounting can be utilized, such as providing a housing that provides separation from the conductive material as well as protection from impact damage. The sensor can be on the same flexible substrate with a narrow throat portion of the sensor between the inductor and the capacitor, Figure 1. The throat is of sufficient length to allow the capacitor to be appropriately placed within the container and the inductor placed outside the container. The throat is fed through the orifice in the container wall (e.g., fuel tank opening) and connects to the inductor and capacitor via electrical leads to form a closed circuit, Figure 2. Another embodiment is to have the inductor and capacitor fabricated as separate units. In this embodiment, the inductor is mounted external to the container, and the capacitor is mounted internal to the container, Figure 1. Electrical leads are fed through the orifice to connect the inductor and capacitor, Figure 2. When a container holding multiple sensors is made of a conductive material, an antenna can be placed internal to the container. An internal antenna allows all components of the sensors to reside inside the container. The antenna must be separated from the container wall s conductive surface. Additionally, the inductors must be maintained in a fixed position relative to and separated from the container

Woodward, Stanley E.↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

Multistage Magnetic Separator of Cells and Proteins

The multistage electromagnetic separator for purifying cells and magnetic particles (MAGSEP) is a laboratory apparatus for separating and/or purifying particles (especially biological cells) on the basis of their magnetic susceptibility and magnetophoretic mobility. Whereas a typical prior apparatus based on similar principles offers only a single stage of separation, the MAGSEP, as its full name indicates, offers multiple stages of separation; this makes it possible to refine a sample population of particles to a higher level of purity or to categorize multiple portions of the sample on the basis of magnetic susceptibility and/or magnetophoretic mobility. The MAGSEP includes a processing unit and an electronic unit coupled to a personal computer. The processing unit includes upper and lower plates, a plate-rotation system, an electromagnet, an electromagnet-translation system, and a capture-magnet assembly. The plates are bolted together through a roller bearing that allows the plates to rotate with respect to each other. An interface between the plates acts as a seal for separating fluids. A lower cuvette can be aligned with as many as 15 upper cuvette stations for fraction collection during processing. A two-phase stepping motor drives the rotation system, causing the upper plate to rotate for the collection of each fraction of the sample material. The electromagnet generates a magnetic field across the lower cuvette, while the translation system translates the electromagnet upward along the lower cuvette. The current supplied to the electromagnet, and thus the magnetic flux density at the pole face of the electromagnet, can be set at a programmed value between 0 and 1,400 gauss (0.14 T). The rate of translation can be programmed between 5 and 2,000 m/s so as to align all sample particles in the same position in the cuvette. The capture magnet can be a permanent magnet. It is mounted on an arm connected to a stepping motor. The stepping motor rotates the arm to position the capture magnet above the upper cuvette into which a fraction of the sample is collected. The electronic unit includes a power switch, power-supply circuitry that accepts 110-Vac input power, an RS-232 interface, and status lights. The personal computer runs the MAGSEP software and controls the operation of the MAGSEP through the RS-232 interface. The status of the power, the translating electromagnet, the capture magnet, and the rotation of the upper plate are indicated in a graphical user interface on the computer screen.

Barton, Ken↗

Sloshing of the Magnetized Cool Gas in the Cores of Galaxy Clusters

X-ray observations of many clusters of galaxies reveal the presence of edges in surface brightness and temperature, known as "cold fronts". In relaxed clusters with cool cores, these edges have been interpreted as evidence for the "sloshing" of the core gas in the cluster's gravitational potential. The smoothness of these edges has been interpreted as evidence for the stabilizing effect of magnetic fields "draped" around the front surfaces. To check this hypothesis, we perform high-resolution magnetohydrodynamics simulations of magnetized gas sloshing in galaxy clusters initiated by encounters with subclusters. We go beyond previous works on the simulation of cold fronts in a magnetized intracluster medium by simulating their formation in realistic, idealized mergers with high resolution ((Delta)x approx. 2 kpc). Our simulations sample a parameter space of plausible initial magnetic field strengths and field configurations. In the simulations, we observe strong velocity shears associated with the cold fronts amplifying the magnetic field along the cold front surfaces, increasing the magnetic field strength in these layers by up to an order of magnitude, and boosting the magnetic pressure up to near-equipartition with thermal pressure in some cases. In these layers, the magnetic field becomes strong enough to stabilize the cold fronts against Kelvin-Helmholtz instabilities, resulting in sharp, smooth fronts as those seen in observations of real clusters. These magnetic fields also result in strong suppression of mixing of high and low-entropy gas in the cluster, seen in our simulations of mergers in the absence of a magnetic field. As a result, the heating of the core due to sloshing is very modest and is unable to stave off a cooling catastrophe.

ZuHone, J. A.↗

Magnetic Reconnection: Theoretical and Observational Perspectives: Preface

Magnetic reconnection is a fundamental plasma-physical process by which energy stored in a magnetic field is converted, often explosively, into heat and the kinetic energy of the charged particles that constitute the plasma. It occurs in a variety of astrophysical settings, ranging from the solar corona to pulsar magnetospheres and winds, as well as in laboratory fusion experiments, where it is responsible for sawtooth crashes. First proposed by R.G. Giovanelli in the late I 940s as the mechanism responsible for solar flares, magnetic reconnection was invoked at the beginning of the space age to explain not just solar flares but also the transfer of energy, mass, and momentum from the solar wind to Earth's magnetosphere and the subsequent storage and release of the transferred energy in the magnetotai\. During the half century or so that has followed the seminal theoretical works by J.W. Dungey, P.A. Sweet, E.N. Parker, and H.E. Petschek, in-situ measurements by Earth-orbiting satellites and remote-sensing observations of the solar corona have provided a growing body of evidence for the occurrence of reconnection at the Sun, in the solar wind, and in the near-Earth space environment. The last thirty years have also seen the development of laboratory reconnection experiments at a number of institutions. In parallel with the efforts of experimentalists in both space and laboratory plasma physics, theorists have investigated, analytically and with the help of increasingly powerful MHD, hybrid, and kinetic numerical simulations, the structure of the diffusion region, the factors controlling the rate, onset, and cessation of reconnection, and the detailed physics that enables the demagnetization of the ions and electrons and the topological reconfiguration of the magnetic field. Moreover, the scope of theoretical reconnection studies has been extended well beyond solar system and laboratory plasmas to include more exotic astrophysical plasma systems whose strong (10(exp 14)-10(exp 15) G) magnetic fields require that models of reconnection in these systems incorporate quantum electrodynamical, special relativistic, and radiative effects. The papers collected in this topical issue of Space Science Reviews cover different aspects of recent theoretical and observational work on magnetic reconnection in solar and space physics, astrophysics, and laboratory plasma physics. They derive from presentations given at a workshop on magnetic reconnection held in the Yosemite National Park, February 8-12,2010. The intent of the workshop was to stimulate, through a combination of tutorial talks, shorter focused talks, and extensive informal discussions, an interdisciplinary dialogue among members of the different research communities working on the problem of magnetic reconnection. One of the motivating considerations for holding the workshop was its relevance to NASA's Magnetospheric Multiscale (MMS) mission, scheduled for launch in 2014. The four identically instrumented MMS spacecraft are designed to study reconnect ion in Earth's magnetosphere and, specifically, to probe the electron diffusion region in order to determine the microphysical processes that enable the change in the topology of the magnetic field. Building on the achievements of the multi spacecraft Cluster and THEMIS missions, MMS will use the magnetosphere as an astrophysical plasma laboratory in which to test, through in-situ measurement of the plasma, energetic particles, and electric and magnetic fields, various models and theories that have emerged during the past twenty years, a period of extraordinarily productive theoretical and observational work.

Lewis, W. S.↗

Penetration of Magnetosheath Plasma into Dayside Magnetosphere: Magnetic Field in Plasma Filaments - 2.

In this paper, we examined plasma structures (filaments), observed in the dayside magnetosphere but containing magnetosheath plasma. These filaments show the stable antisunward motion (while the ambient magnetospheric plasma moved in the opposite direction) and the existence of a strip of magnetospheric plasma, separating these filaments from the magnetosheath. These results, however, contradict both theoretical studies and simulations by Schindler (1979), Ma et al. (1991), Dai and Woodward (1994, 1998), and other researchers, who reported that the motion of such filaments through the magnetosphere is possible only when their magnetic field is directed very close to the ambient magnetic field, which is not the situation that is observed. In this study, we show that this seeming contradiction may be related to different events as the theoretical studies and simulations are related to the case when the filament magnetic field is about aligned with filament orientation, whereas the observations show that the magnetic field in these filaments may be rotating. In this case, the rotating magnetic field, changing incessantly its direction, drastically affects the penetration of plasma filaments into the magnetosphere. In this case, the filaments with rotating magnetic field, even if in each moment it is significantly inclined to the ambient magnetic field, may propagate through the magnetosphere, if their average (for the rotation period) magnetic field is aligned with the ambient magnetic field. This shows that neglecting the rotation of magnetic field in these filaments may lead to wrong results.

Lyatsky, Wladislaw↗

MMS Observations of Ion-Scale Magnetic Island in the Magnetosheath Turbulent Plasma

In this letter, first observations of ion-scale magnetic island from the Magnetospheric Multiscale mission in the magnetosheath turbulent plasma are presented. The magnetic island is characterized by bipolar variation of magnetic fields with magnetic field compression, strong core field, density depletion, and strong currents dominated by the parallel component to the local magnetic field. The estimated size of magnetic island is about 8 di, where di is the ion inertial length. Distinct particle behaviors and wave activities inside and at the edges of the magnetic island are observed: parallel electron beam accompanied with electrostatic solitary waves and strong electromagnetic lower hybrid drift waves inside the magnetic island and bidirectional electron beams, whistler waves, weak electromagnetic lower hybrid drift waves, and strong broadband electrostatic noise at the edges of the magnetic island. Our observations demonstrate that highly dynamical, strong wave activities and electron-scale physics occur within ion-scale magnetic islands in the magnetosheath turbulent plasma..

Huang, S. Y.↗

Magnetic Shield Design Modeling and Validation for SWOT Spacecraft Ka-Band Extended Interaction Klystron

Two Extended Interaction Klystrons (EIKs) containing strong permanent magnets were modeled magnetically in a representative spacecraft geometry using commercial finite element modeling techniques and were validated against measurements made at varying distances. Initial modeling results for the 63 A-m2 (amperes per square meter) dipole moment magnets showed that magnetic shields would be necessary in order to meet magnetic field requirements for the Surface Water and Ocean Topography (SWOT) spacecraft, which contains components that are susceptible to external DC (Direct Current) magnetic fields. JPL (Jet Propulsion Laboratory) and the EIK vendor proposed cold rolled steel and mu-metal as potential shield materials along with proposed thicknesses of 0.5 millimeters and 1.5 millimeters. Magnetic shields made from each of these materials were designed and modeled in software, taking high-field saturation into account. Prototype magnetic shields with these parameters were then built, measured with an existing EIK, and compared against modeling results. For single-axis field measurements along the dipole axis, modeling results were within 7 gauss of the measured values at 10 centimeters from the magnet, and converged to less than 1.5 gauss at distances greater than 14 centimeters from the magnet. Three-axis field measurements at locations of interest showed that model correlation improved to within 4 gauss at 11 centimeters and 2 gauss for distances ranging between 15 centimeters and 36 centimeters.

Gonzales, Edward↗

Magnetic Shield Design Modeling and Validation for SWOT Spacecraft Ka-Band Extended Interaction Klystron

Two Extended Interaction Klystrons (EIKs) containing strong permanent magnets were modeled magnetically in a representative spacecraft geometry using commercial finite element modeling techniques and were validated against measurements made at varying distances. Initial modeling results for the 63 A-m2 dipole moment magnets showed that magnetic shields would be necessary in order to meet magnetic field requirements for the Surface Water and Ocean Topography (SWOT) spacecraft, which contains components that are susceptible to external DC magnetic fields. JPL and the EIK vendor proposed cold rolled steel and mu-metal as potential shield materials along with proposed thicknesses of 0.5 mm and 1.5 mm. Magnetic shields made from each of these materials were designed and modeled in software, taking highfield saturation into account. Prototype magnetic shields with these parameters were then built, measured with an existing EIK, and compared against modeling results. For single-axis field measurements along the dipole axis, modeling results were within 7 gauss of the measured values at 10 cm from the magnet, and converged to less than 1.5 gauss at distances greater than 14 cm from the magnet. Three-axis field measurements at locations of interest showed that model correlation improved to within 4 gauss at 11 cm and 2 gauss for distances ranging between 15 cm and 36 cm.

Gonzales, Edward↗

Methods and apparatus for making magnetic skyrmions

A system and a method for the deterministic generation of magnetic skyrmions includes a magnetic strip configured to store and transport skyrmions. The magnetic strip includes one or more spatial inhomogeneities configured to generate a skyrmion at known locations when excited by a current pulse. A current pulse generator is used to inject current pulses into the magnetic strip via contact pads electrically coupled to both the current pulse generator and the magnetic strip. The system also includes a magnetic field source to apply an out-of-plane magnetic field across the magnetic strip to facilitate generation of skyrmions. Skyrmions can be generated by applying an out-of-plane magnetic field to the magnetic strip and injecting a current pulse with sufficient current density towards the spatial inhomogeneities. Once a skyrmion is generated, another current pulse with sufficient current density can be injected to move the skyrmion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding magnetic phase coexistence in Ru 2 Mn 1-x Fe x Sn Heusler alloys: A neutron scattering, thermodynamic, and phenomenological analysis

The random substitutional solid solution between the antiferromagnetic (AFM) full-Heusler alloy Ru 2 MnSn and the ferromagnetic (FM) full-Heusler alloy Ru 2 FeSn provides a rare opportunity to study FM-AFM phase competition in a near-lattice-matched, cubic system, with full solubility. At intermediate x in Ru 2 Mn 1-x Fe x Sn this system displays suppressed magnetic ordering temperatures, spatially coexisting FM and AFM order, and strong coercivity enhancement, despite rigorous chemical homogeneity. Here, we construct the most detailed temperature- and x-dependent understanding of the magnetic phase competition and coexistence in this system to date, combining wide-temperature-range neutron diffraction and small-angle neutron scattering with magnetometry and specific heat measurements on thoroughly characterized polycrystals. A complete magnetic phase diagram is generated, showing FM-AFM coexistence between x ≈ 0.30 and x ≈ 0.70. Furthermore, important insight is gained from the extracted length scales for magnetic phase coexistence (25–100 nm), the relative magnetic volume fractions and ordering temperatures, and remarkable x-dependent trends in magnetic and electronic contributions to specific heat. An unusual feature in the magnetic phase diagram (an intermediate FM phase) is also shown to arise from an extrinsic effect related to a minor Ru-rich secondary phase. The established magnetic phase diagram is then discussed with the aid of phenomenological modeling, clarifying the nature of the mesoscale phase coexistence with respect to the understanding of disordered Heisenberg models.

36 MATERIALS SCIENCE↗

Magnetic‐Field‐Switchable Laser via Optical Pumping of Rubrene

Abstract Volumetric optical imaging of magnetic fields is challenging with existing magneto‐optical materials, motivating the search for dyes with strong magnetic field interactions, distinct emission spectra, and an ability to withstand high photon flux and incorporation within samples. Here, the magnetic field effect on singlet‐exciton fission is exploited to demonstrate spatial imaging of magnetic fields in a thin film of rubrene. Doping rubrene with the high‐quantum yield dye dibenzotetraphenylperiflanthene (DBP) is shown to enable optically pumped, slab waveguide lasing. This laser is magnetic‐field‐switchable: when operated just below the lasing threshold, application of a 0.4 T magnetic field switches the device between nonlasing and lasing modes, accompanied by an intensity modulation of +360%. This is thought to be the first demonstration of a magnetically switchable laser, as well as the largest magnetically induced change in emission brightness in a singlet‐fission material to date. These results demonstrate that singlet‐fission materials are promising materials for magnetic sensing applications and could inspire a new class of magneto‐optical modulators.

36 MATERIALS SCIENCE↗

Quantum Disordered State of Magnetic Charges in Nanoengineered Honeycomb Lattice

Abstract A quantum magnetic state due to magnetic charges is never observed, even though they are treated as quantum mechanical variables in theoretical calculations. Here, the occurrence of a novel quantum disordered state of magnetic charges in a nanoengineered magnetic honeycomb lattice of ultra‐small connecting elements is demonstrated. The experimental research, performed using spin resolved neutron scattering, reveals a massively degenerate ground state, comprised of low integer and energetically forbidden high integer magnetic charges, that manifests cooperative paramagnetism at low temperature. The system tends to preserve the degenerate configuration even under large magnetic field application. It exemplifies the robustness of disordered correlation of magnetic charges in a 2D honeycomb lattice. The realization of quantum disordered ground state elucidates the dominance of exchange energy, which is enabled due to the nanoscopic magnetic element size in nanoengineered honeycomb. Consequently, an archetypal platform is envisaged to study quantum mechanical phenomena due to emergent magnetic charges.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Magneto-Transport Properties of Cr 1/3 TaS 2 with Chiral Magnetic Solitons

Cr 1/3 TaS 2 —a candidate of chiral magnet—has been reported as a trivial ferromagnetic material. In contrast, the Cr 1/3 TaS 2 single crystals exhibit a chiral helimagnetic (CHM) transition near 140 K. The magnetic moment versus magnetic field curves reveal a CHM—chiral soliton lattice (CSL)—forced ferromagnetic (FFM) transition in the magnetic ordered state. The conducting electrons interact with the CHM and CSL orders, giving rise to the nontrivial magnetoresistance (MR) in the Cr 1/3 TaS 2 single crystals. The normalized magnetic moment and normalized MR fit well with the analytical functions for chiral soliton density. The magnetic phase diagrams constructed from the magnetic moment data and MR data suggest a possible tri-critical point. Compared with the isostructural Cr 1/3 NbS 2 , the CHM transition temperature of Cr 1/3 TaS 2 is 13 K higher, the CSL—FFM transition field is about 10 times larger, and the Dzyaloshinskii-Moriya interaction strength is 3 times bigger. The latter two likely originate from the strong spin-orbit coupling (SOC) of Cr 1/3 TaS 2 . This work clarifies that high-quality Cr 1/3 TaS 2 single crystals are chiral magnets and Cr 1/3 (Nb,Ta)S 2 could serve as an intriguing platform for the flexible engineering of chiral magnetic solitons with tunable SOC.

36 MATERIALS SCIENCE↗

Development of rare-earth-free bulk magnets with energy product up to 12 MGOe in field annealed Mn–Bi–Mg–In–Sb alloys

A treatment consisting of annealing in a moderately strong, ≤30 kOe, magnetic field was applied to arc-melted ingots and compacted melt-spun alloys with composition Mn 50 Bi 50-x-y-z Mg x In y Sb z . The high degree of texture of the magnetic α phase induced with annealing of the ingot samples (except the Mn–Bi–Sb one) allowed for accurate determination of the phase anisotropy field. Alloying was found to increase the anisotropy field from 45 kOe in the Mn 50 Bi 50 alloy to 65 kOe in the Mn 50 Bi 45 Mg 3 In 0.5 Sb 1.5 alloy. In the compacted melt-spun alloys subjected to field annealing, a higher degree of texture could be achieved after compaction which had involved less heating, when a smaller fraction of the metastable β' phase had been converted into the α phase; compaction at room temperature allowed for the highest degree of texture in the Mn 50 Bi 45 Mg 3 In 0.5 Sb 1.5 magnet. The addition of indium was found to decrease the solidus temperatures of the alloys, facilitating the development of the α phase during the field annealing and modifying the properties of the resulting magnets. Introduction of indium resulted in a higher coercivity H c of the Mn–Bi–Mg–In magnets and in a better texture of the Mn–Bi–Mg–Sn–In magnets. The former effect allowed, in particular, for a viable maximum energy product ( BH ) max of 10 MGOe to be developed in the Mn 50 Bi 46.5 Mg 3 In 0.5 magnet through annealing in a relatively low field of 15 kOe, whereas the latter effect allowed for an excellent combination of ( BH ) max = 11.6 MGOe and H c = 8.5 kOe in the Mn 50 Bi 45 Mg 3 In 0.5 Sb 1.5 magnet. The highest ( BH ) max of 12 MGOe was realized in the Mn 50 Bi 46 Mg 3 In 0.5 Sb 0.5 magnet.

36 MATERIALS SCIENCE↗

Transition from an incommensurate spin density wave to a commensurate magnetic order in a triangular lattice compound Ho 2 PdAl 6 Ge 4

Rare-earth (RE) intermetallics on a triangular lattice are promising candidates for generating interesting magnetic phases due to the complex interplay between Ruderman-Kittel-Kasuya-Yoshida (RKKY) interaction and geometrical frustration. Here, in this work, we report the exotic magnetic structure of a layered compound Ho 2 PdAl 6 Ge 4 with triangular lanthanide nets. Magnetization and heat capacity measurements in zero magnetic field reveal two magnetic phase transitions at T N1 = 10.8 K and T N2 = 6.0 K. Neutron powder diffraction demonstrates a commensurate antiferromagnetic phase with k 1 = (0, 0, 1.5) below T N2 . With increasing temperature, another incommensurate vector appears and therefore, the magnetic structure of the intermediate state is identified as an unusual incommensurate spin density wave with two propagation vectors k 1 = (0, 0, 1.5) and k 2 = (0.0492, 0.0492, 1.5). The magnetic moments in the intermediate state rotate continuously and form an unusual S-shaped wave arrangement in the ab plane, sharing similarities with typical cycloid and helix magnetic orders. These results identify Ho 2 PdAl 6 Ge 4 as a candidate for exploring field-induced topological magnetic phases such as skyrmions, opening the way for further investigations on the family of RE 2 PdAl 6 Ge 4 materials.

36 MATERIALS SCIENCE↗

Evolution of Structure and Magnetism in FeCl 2 and FeCl 3 : From Clusters to Monolayers

In this work, we address one of the most fundamental questions in cluster science─how do the structure and properties evolve from clusters to crystals? Using density functional theory (DFT), we focus our study on the evolution of structure and magnetism in iron-chloride systems, from clusters to monolayers. The choice of this system is motivated by the recent experimental confirmation of one of the author’s earlier theoretical prediction that the FeCl 2 cluster is magnetic with a spin magnetic moment of 4 μ B localized at the Fe site, while its dimer, Fe 2 Cl 4 , is antiferromagnetic. Similarly, FeCl 3 cluster is magnetic with a total spin magnetic moment of 5 μ B , with 4 μ B localized at the Fe site and 1 μ B distributed over the Cl sites. The dimer clusters Fe 2 Cl 4 and Fe 2 Cl 6 have an antiferromagnetic ground state, and upon Li-functionalization, both can be magnetically transformed from antiferromagnetic to ferromagnetic states. In contrast, FeCl 2 and FeCl 3 monolayers exhibit different magnetic ground states in their periodic forms: FeCl 2 is ferromagnetic (FM), but in FeCl 3 , the antiferromagnetic (AFM) and FM states are energetically nearly degenerate. Such a difference arises due to the different chemical coordination of the Fe atoms with the Cl atoms, caused by their different oxidation states, which is +2 in FeCl 2 and +3 in FeCl 3 , respectively. Interestingly, Li-functionalization allows both FeCl 3 and FeCl 2 monolayers to be ferromagnetic. Our study highlights that several, but not all, electronic and magnetic characteristics of isolated clusters are preserved in the extended periodic structures. This systematic investigation of iron-halide clusters is expected to inspire further experimental and theoretical exploration into the magnetism of other transition metal halides.

cluster chemistry↗