SEARCH · Engineering Papers
Results for “MOVES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
USNCCM-11: Computational fluid mechanics for free and moving boundary problems
Abstract not provided.
A particle resolved simulation approach for studying shock interactions with moving, colliding solid particles
This work applies a new combination of techniques for the fully resolved simulation of compressible, gas–particle multiphase flows. Here, the adaptive wavelet collocation method is used to dynamically, and efficiently, adapt the computational grid to localized flow features and the particles. A characteristic-based volume penalization method that imposes arbitrary Dirichlet, Neumann, or Robin-type immersed boundary conditions, is used to enforce the no-slip condition at particle surfaces. A hard-sphere collision model is applied to capture the particle–particle collisions. Proof of concept test cases are presented, showcasing the dynamic grid adaptation and fully resolved two-way coupling between the phases that is possible with this approach. Results for a shock-driven single cylinder under viscous and inviscid conditions are presented along with a demonstration of a shock interacting with a cloud of randomly distributed cylinders and spheres.
Numerical performances of invariable and moving boundary methods during fluid penetration into anisotropic porous media
Not Available
Rapidly moving new bacteria to model-organism status
The paradigm of large research communities collectively working on a small number of model bacteria such as Escherichia coli and Bacillus subtilis is changing. While these classic model bacteria will continue to be important for advanced systems biology and new technology development, we envision that increasingly small research teams will be deeply investigating their own favorite strains, for example as new hosts for metabolic engineering or as key members of a complex microbiome. Given the lack of a research community and the sheer number of possible bacteria to interrogate, the development and application of technologies to rapidly and inexpensively advance these unstudied strains to ‘model-organism’ status is imperative. Here, we discuss the minimal information and tools necessary to develop a new model bacterium and how existing approaches can bring this power into the hands of a single investigator.
Whole-plant phenotypic engineering: moving beyond ratios for multi-objective optimization of nutrient use efficiency
Nutrient use efficiency (NUE) is typically measured as the ratio of yield to soil nutrient availability but ignores contributions of underlying plant traits. Relevant plant traits can be grouped as root acquisition efficiency, shoot radiation use efficiency, and plant metabolic efficiency. The intentional integration of these traits will lead to synergistic improvements of NUE. Recent progress in trait-focused research includes phenotyping root nutrient uptake rates and respiration, engineering reduced photorespiration, and identification of nutrient assimilation pathways. Traits need to be conceptualized in agricultural systems contexts to improve synchrony of plant demand and soil supply of nutrients, including consideration of crop mixtures. Use of simulation modeling and multi-objective optimization will allow accelerating NUE gains beyond selection for a single ratio.
Close encounters: Moving along bumps, breaks, and bubbles on expanded trinucleotide tracts
Expansion of simple triplet repeats (TNR) underlies greater than 30 severe degenerative diseases. There is a good understanding of the major pathways generating an expansion, and the associated polymerases that operate during gap filling synthesis at these “difficult to copy” sequences. However, the mechanism by which a TNR is repaired depends on the type of lesion, the structural features imposed by the lesion, the assembled replication/repair complex, and the polymerase that encounters it. The relationships among these parameters are exceptionally complex and how they direct pathway choice is poorly understood. In this review, we consider the properties of polymerases, and how encounters with GC-rich or abnormal structures might influence polymerase choice and the success of replication and repair. Insights over the last three years have highlighted new mechanisms that provide interesting choices to consider in protecting genome stability.
Moving beyond the limits of mass transport in liquid absorbent microfilms through the implementation of surface-induced vortices
The slow diffusion of an absorbate molecule into an absorbent often makes the absorption process a rate-limiting step in many applications. In cases involving an absorbate with a high heat of phase change, such as water absorption into a LiBr (lithium bromide) solution, the absorption rate is further slowed due to significant heating of the absorbent. Recently, it has been demonstrated that constraining a LiBr solution film by a hydrophobic porous structure enables manipulation of the solution flow thermohydraulic characteristics. Here, it is shown that mass transport mode in a constrained laminar solution flow can be changed from diffusive to advective. This change in mode is accomplished through stretching and folding the laminar streamlines within the solution film via the implementation of micro-scale features on the flow channel surface. The process induces vortices within the solution film, which continuously bring concentrated solution from the bottom and middle of the solution channel to its interface with the vapor phase, thus leading to a significant enhancement in the absorption rate. The detailed physics of the involved transport processes is elucidated using the LBM (Lattice Boltzmann Method). Published by Elsevier Ltd.
Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis
The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector), ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.
Moving from Misinformation Derived from Public Attitude Surveys on Carbon Dioxide Capture and Storage toward Realistic Stakeholder Involvement
Stakeholder involvement can include many activities, from providing information on a website to one-on-one conversations with people confronting an issue in their community. For carbon dioxide capture and storage (CCS) a major tool of SI to date has been the survey. Recent surveys and other research into stakeholder involvement focused on the nascent commercial deployment of CCS technologies have provided valuable information about the state of general knowledge and attitudes toward these technologies. Most importantly, these research efforts reveal that the general public has relatively little knowledge about CCS. Given this lack of knowledge with respect to the concept of CCS let alone first-hand experiential knowledge derived from seeing these technologies deployed in local communities this paper critiques the methodology and results of the survey research. Then the framing of SI in CCS is examined, including the assumption that clear stakeholder acceptance is a realistic goal and that the public has a decisive say in choosing the energy technologies of the present and the future. Finally, a broader suite of SI activities is recommended as more suited to realistic and contextual goals.
New semi-analytical solution for a uniformly moving mass on a beam on a two-parameter visco-elastic foundation
Not Available
Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution
Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.
Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.