Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ML”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Preoperative Transcatheter Arterial Embolization for Nasopharyngeal Angiofibroma: A Comparative Study

ObjectiveThis study aimed to retrospectively evaluate the efficacy and safety of preoperative transcatheter arterial embolization (pTAE) for treating nasopharyngeal angiofibroma (NPAF).MethodsSeventy-four NPAF patients were hospitalized for elective surgical treatment with pTAE (pTAE group, n = 32) or surgical treatment alone (non-pTAE group, n = 42) between January 1990 and December 2013. The following outcome measures were retrospectively analyzed and compared: intraoperative bleeding volume, surgery time (ST), duration of postoperative hospital stay (PHS), and disease recurrence.ResultsAmong Radkowski stage I patients, those in pTAE group had a slightly higher but not significant bleeding volume than patients in non-pTAE group (344 ± 407 vs. 248 ± 219 mL, P = 0.899); among stage II/III patients, however, patients in pTAE group showed a significantly lower bleeding volume than patients in non-pTAE group (stage II, 829 ± 519 vs. 1339 ± 767 mL, P = 0.035; stage III, 1267 ± 592 vs. 2125 ± 479 mL, P = 0.024). The two groups presented comparable OTs, PHSs, and rates of frontal recurrence (all P>0.05).ConclusionspTAE significantly reduces intraoperative bleeding in NPAF patients with Radkowski stage II/III disease, but offers no additional benefits regarding ST, PHS, or recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future Liver Remnant Indocyanine Green Plasma Clearance Rate as a Predictor of Post-hepatectomy Liver Failure After Portal Vein Embolization

PurposeTo evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).Materials and MethodsPVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) − tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE. PHLF was categorized according to the criteria of the International Study Group of Liver Surgery. For predicting PHLF, we compared the ICGK-F and %FLR after PVE between the grade A PHLF group and the non-grade A PHLF (grades B and C) group.ResultsAll PVE procedures were successful. While the ICGK-F of the grade A PHLF group (median 0.073, n = 16) was about twice that of the non-grade A PHLF group (median 0.043, n = 4), showing a significant difference (Mann–Whitney U test: P = 0.002), there was no significant difference in %FLR between the grade A PHLF group and the non-grade A PHLF group (Mann–Whitney U test: P = 0.335).ConclusionICGK-F was significantly higher in the grade A PHLF group than in the non-grade A PHLF group (grades B and C), and ICGK-F was more useful for predicting PHLF than %FLR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling household online shopping demand in the U.S.: a machine learning approach and comparative investigation between 2009 and 2017

Despite the rapid growth of online shopping and research interest in the relationship between online and in-store shopping, national-level modeling and investigation of the demand for online shopping with a prediction focus remain limited in the literature. Here, this paper differs from prior work and leverages two recent releases of the U.S. National Household Travel Survey (NHTS) data for 2009 and 2017 to develop machine learning (ML) models, specifically gradient boosting machine (GBM), for predicting household-level online shopping purchases. The NHTS data allow for not only conducting nationwide investigation but also at the level of households, which is more appropriate than at the individual level given the connected consumption and shopping needs of members in a household. We follow a systematic procedure for model development including employing Recursive Feature Elimination algorithm to select input variables (features) in order to reduce the risk of model overfitting and increase model explainability. Among several ML models, GBM is found to yield the best prediction accuracy. Extensive post-modeling investigation is conducted in a comparative manner between 2009 and 2017, including quantifying the importance of each input variable in predicting online shopping demand, and characterizing value-dependent relationships between demand and the input variables. In doing so, two latest advances in machine learning techniques, namely Shapley value-based feature importance and Accumulated Local Effects plots, are adopted to overcome inherent drawbacks of the popular techniques in current ML modeling. The modeling and investigation are performed at the national level, with a number of findings obtained. The models developed and insights gained can be used for online shopping-related freight demand generation and may also be considered for evaluating the potential impact of relevant policies on online shopping demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correction to: The effect of beta blocker withdrawal on adenosine myocardial perfusion imaging

Regrettably the original version of the above article contained errors in Table 2 and wrong values in the text. The corrected table is presented here and the values which have been corrected now appear in bold text. Page 1223 abstract Global MBF showed an increase from 180.2 ± 59.9 to 193.6 ± 60.8 mL minute/100 g (P = .002) after beta blocker withdrawal. Page 1225 Mean systolic and mean diastolic blood pressure during adenosine were nearly identical (P = .77 and P = .79) with and without beta blocker. Mean heart rate and mean RPP during adenosine significantly increased after beta blocker withdrawal by 15.2% ± 17% (P = .001) and 16.2% ± 23% (P = .004), respectively. Page 1226 The data are listed in Table 2, lower third. Global MBF showed a significant increase by 7.4% ± 10% (P = .002) after beta blocker withdrawal. The individual data are depicted in Figure 1. All but three patients had a lower global MBF without beta blocker than with. The segmental MBF values (Figure 2) demonstrated a strong correlation over the entire range of perfusion values. The average effect was a slight perfusion shift of about 1015 mL minute-1/100 g in the range of 100-300 mL minute-1/100 g. The mCR under adenosine declined by 8.1% ± 11% (P = .038) and the normalized RPP by 16.2% ± 21% (P = .004) after betablocker discontinuation. Table 2 Hemodynamic response under adenosine, perfusion, and left-ventricular function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of regadenoson-induced myocardial creep on dynamic Rubidium-82 PET myocardial blood flow quantification

Background: Repositioning of the heart during myocardial perfusion imaging (MPI) using Rubidium-82 (Rb-82) PET may occur when using regadenoson. Our aim was to determine the prevalence and the effect of correcting for this myocardial creep on myocardial blood flow (MBF) quantification. Methods: We retrospectively included 119 consecutive patients who underwent dynamic rest- and regadenoson-induced stress MPI using Rb-82 PET. The presence of myocardial creep was visually assessed in the dynamic stress PET series by identifying differences between the automatically drawn myocardium contour and the activity. Uncorrected and corrected stress MBFs were compared for the three vascular territories (LAD, LCX, and RCA) and for the whole myocardium. Results: Myocardial creep was observed in 52% of the patients during stress. Mean MBF values decreased after correction in the RCA from 4.0 to 2.7 mL/min/g (P < 0.001), in the whole myocardium from 2.7 to 2.6 mL/min/g (P = 0.01), and increased in the LAD from 2.5 to 2.6 mL/min/g (P = 0.03) and remained comparable in the LCX (P = 0.3). Conclusions: Myocardial creep is a frequent phenomenon when performing regadenoson-induced stress Rb-82 PET and has a significant impact on MBF values, especially in the RCA territory. As this may hamper diagnostic accuracy, myocardial creep correction seems necessary for reliable quantification. [French] French Abstract: Contexte: Un repositionnement du cœur lors de l’imagerie de perfusion myocardique (MPI) à l’aide de la TEP au rubidium-82 (RB-82) peut survenir lors de l’utilisation du regadenoson. Notre objectif était de déterminer la prévalence et l’effet de la correction du fluage sur la quantification du débit sanguin myocardique (DSM). Méthodes: dans cette étude rétrospective, nous avons inclus 119 patients consécutifs ayant beneficié d’un examen au repos suivi d’un stress pharamacologique au régadénoson en utilisant le RB-82. La présence de fluage myocardique a été évaluée visuellement sur les images TEP de stress dynamique en utilisant les différences entre les contours automatiques et les images myocardiques. Les DSM de stress non corrigés et corrigés ont été comparés pour les trois territoires vasculaires (coronaire gauche-CG, la circonflexe-CX, et coronaire droite-CD) et pour l’ensemble du myocarde. Résultats: le fluage myocardique a été observé chez 52% des patients sur les examens de stress. Les valeurs moyennes de DSM ont diminué après correction dans le territoire de la CD de 4,0 à 2,7 mL/min/g (p < 0,001), dans le myocarde entier de 2,7 à 2,6 mL/min/g (p = 0,01) et augmenté dans le territoire de la CG de 2,5 à 2,6 mL/min/g (p = 0,03) et est resté comparable dans le territoire de la CX (p = 0,3). Conclusions: le fluage myocardique est un phénomène fréquent lors de l’exécution du stress phramacologique au régadénoson à l’aide du RB-82. Il a un impact significatif sur les valeurs de DSM, en particulier dans le territoire de la CD. La correction du fluage myocardique semble donc nécessaire pour une quantification fiable des flux coronariens. [Spanish] Spanish Abstract: Antecedentes: El movimiento del corazón durante la imagen de perfusión miocárdica usando Rubidio-82 (Rb-82) PET puede ocurrir cuando se usa regadenosón. Nuestro enfoque fue determinar la prevalencia y efecto de la corrección de este Artefacto de movimiento en la cuantificación del flujo sanguíneo miocárdico. Métodos: Se incluyeron de forma retrospectiva 119 pacientes que se realizaron estudio dinámico en reposo y estudio de perfusión miocárdica en estrés inducido por regadenosón usando Rb-82 PET. La presencia de el artefacto de movimiento fue evaluado visualmente en el estudio en serie de PET dinámico en estrés identificando las diferencias entre el contorno miocárdico dibujado automáticamente y la actividad. La perfusión miocárdica en estrés corregida y sin corregir se compararon para los tres territorios vasculares (Descendente Anterior, Circunfleja, Coronaria Derecha) y para todo el miocardio. Resultados: El artefacto de movimiento miocárdico se observo en un 52% de los pacientes durante el estrés. El promedio de los valores de flujo sanguíneo miocárdico disminuyen después de la corrección en la arteria coronaria derecha de 4.0 a 2.7 ml/min/g (p < 0.001), en todo el miocardio de 2.7 a 2.6 mL/min/g (p = 0.01) y un aumento en la arteria descendente anterior de 2.5 a 2.6 mL/min/g (p = 0.03) y se mantuvo comparable en la arteria circunfleja (p = 0.3). Conclusiones: El artefacto de movimiento miocárdico es un fenómeno frecuente cuando se realiza la prueba de estrés inducido con regadenosón Rb-82 PET y tiene un impacto significativo en los valores de flujo sanguíneo miocárdico, principalmente en el territorio de la coronaria derecha. Esto puede disminuir la precisión diagnostica, la corección del artefacto de movimiento es necesario para una cuantificación confiable. [Chinese] Chinese Abstract: 背景: 铷-82 (Rb-82) PET心肌灌注成像 (MPI) 过程在使用类伽腺苷时可能会发生心脏重定位。我们的目的是确定心肌蠕动 (myocardial creep) 校正对心肌血流灌注定量的影响及其普遍性。 方法: 我们连续回顾了119 名使用 Rb-82 PET 进行动态的静息与类伽腺苷负荷MPI的患者。通过识别自动绘制的心肌轮廓和心肌活动之间的差异, 在动态负荷 PET 检查中肉眼评估心肌蠕动的存在。分别在已校正和未校正的负荷 MBF上, 对三个血管区域 (LAD, LCX, RCA) 和整个心肌灌注情况进行比较。 结果: 负荷检查中, 52% 的患者观察到心肌蠕动。 RCA 校正后平均MBF值从4.0降至 2.7 mL / min / g (p <0.001), 整个心肌从 2.7降至 2.6 mL / min / g (p = 0.01) , LAD 从 2.5 升至 2.6mL / min / g (p = 0.03) 并且在LCX中保持不变 (p = 0.3) 。 结论: 类伽腺苷负荷 Rb-82 PET 检查中, 心肌蠕动是一种常见的现象, 并且对 MBF 值有显著影响, 特别在 RCA 区域。这可能妨碍诊断准确性, 因此心肌蠕动校正是准确定量的必要条件。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrochemical Immunoassay of Cotinine in Serum Based on Nanoparticle Probe and Immunochromatographic Strip

A disposable sensor for the determination of cotinine in human serum was developed based on immunochromatographic test strip and quantum dot label. In this assay, cotinine modified on quantum dot competes with cotinine in sample to bind to anti-cotinine antibody in the test strip and the quantum dots serve as signal vehicles for electrochemical readout. Some parameters governing the performance of the sensor were optimized. The sensor shows a wide linear range from 1 ng mL-1 to 100 ng mL-1 cotinine with a detection limit of 1.0 ng mL-1. The relative standard deviation (R.S.D.) of the sensor was less than 2% for cotinine. The sensor was validated with spiked human serum samples and it was found that this method was reliable in measuring cotinine in human serum with average recovery of 100.99%. The results demonstrate that this sensor is a rapid, clinically accurate, and less expensive and has the potential for point of care (POC) detection of cotinine and fast screening of tobacco smoke exposure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A machine learning approach to fracture mechanics problems

Analytical and empirical solutions to engineering problems are usually preferred because of their convenience in applications. However, they are not always accessible in complex problems. A new class of solutions, based on machine learning (ML) models such as regression trees and neural networks (NNs), are proposed and their feasibility and value are demonstrated through the analysis of fracture toughness measurements. It is found that both solutions based on regression trees and NNs can provide accurate results for the specific problem, but NN-based solutions outperform regression-tree-based solutions in terms of their simplicity. Here this example demonstrates that ML solutions are a major improvement over analytical and empirical solutions in terms of both reliable functionality and rapid deployment. When analytical solutions are not available, the use of ML solutions can overcome the limitations of empirical solutions and substantially change the way that engineering problems are solved.

36 MATERIALS SCIENCE↗

Automated detection of part quality during two-photon lithography via deep learning

Two-photon lithography (TPL) is an additive manufacturing technique for fabricating three-dimensional objects with nanoscale features. A main challenge of TPL is the routine and labor-intensive task of finding suitable light dosage parameters, i.e. writing speed and laser intensity that induce photo-polymerization within a wide variety of candidate photo-curing polymers. Another challenge is the monitoring required during fabrication. In this work, we apply machine learning (ML) models to accelerate the process of identifying optimal light dosage parameters and automate the detection of part quality. We curate TPL videos of different parts fabricated under a range of light dosage parameters using different resins and train spatial-temporal ML models on this data. Our results show that ML models can detect TPL part quality with a 95.1% accuracy in milliseconds. We also evaluate classification failures and identify two operating modes: parameter optimization and part quality detection. Last but not least, we publicly release this labelled dataset so that it may serve as a useful benchmark to the community. Our approach to process optimization and part quality detection addresses important aspects of TPL industrialization, is applicable beyond TPL and should benefit other additive manufacturing techniques with similar barriers to operating at industrial scale.

36 MATERIALS SCIENCE↗

Explainable machine learning to quantify the value of proximal remote sensing in latent energy flux estimation

Proximal remote sensing has the potential to provide critical information on vegetation biophysical factors that can predict land-atmosphere exchange of water and energy. Latent energy (LE) flux is traditionally estimated using process-based models which rely on vegetation parameters that change during the growing season. Data-driven models have the potential to address these issues by offering flexible predictor selection and more efficient utilization of the information in predictor sets. These models require careful choice of predictors to avoid redundancy and allow robust cross-validation. In this study we present a systematic and comprehensive evaluation of machine learning (ML) models to assess the capability of meteorological and proximal sensing data for predicting LE at a half-hourly temporal resolution across multiple growing seasons for an agricultural system. The results presented here demonstrate that a model using four environmental predictors in combination with two proximal sensing variables can capture 88 % of the variability in LE. ML models using only three predictors (one meteorological and two proximal remote sensing) captured 81 % of LE variability, offering the best trade-off between performance and complexity. An ML model utilizing only two predictors, one proximal remote sensing variable and downwelling radiation, captured 77 % of LE variability. These results demonstrate the power of proximal remote sensing and meteorological observations to estimate land-atmosphere water vapor exchange, providing a solution where more direct methods such as eddy covariance are not available and for evaluations of agronomic management and genotypic variations.

60 APPLIED LIFE SCIENCES↗

Situational awareness-enhancing community-level load mapping with opportunistic machine learning

Motivated by present and forthcoming challenges in the adoption and integration of distributed renewable energy, we develop a machine learning (ML) approach that builds short-fuse mappings connecting the occasionally-unobservable true load in one target community with information-rich signals collected from relatively more instrumented reference communities. Our setting is inspired by and tailored to target communities with significant unobservable behind-the-meter solar generation, where true load (a relatively well-behaved quantity of interest to grid operators) is hard to discern during daytime due to insufficient instrumentation and/or privacy reasons, but that can be related to reference communities with low unobservable distributed variable generation or with sufficient instrumentation. The developed mapping, herein realized with Support Vector Machine regression, is built using nighttime data from all communities, when their distributed generation is low or zero. Our ML algorithm opportunistically learns to correlate signals of interest and then is operationally used the next day to shed light into target community load evolution. The mapping is subsequently rebuilt, rolling its short-fuse scope perpetually forward in time. Here, we demonstrate the efficacy of our approach on nine synthetically generated topologies and associated timeseries stemming from real-world data, on which we observe cumulative error performance that yields lower than 10% and 15% daily-averaged mean absolute percentage errors in target community load estimation on more than about 75% and 90% of days, respectively, in multiple yearly evaluations that shed light on long-term performance also under seasonal and one-off effects. The proposed ML-powered methodology can offer grid operators much-improved visibility into a previously obscure space and can also serve as an additional source of information in broader, multi-modal solar disaggregation solutions.

14 SOLAR ENERGY↗

A chemistry-informed hybrid machine learning approach to predict metal adsorption onto mineral surfaces

Historically, surface complexation model (SCM) constants and distribution coefficients (K d ) have been employed to quantify mineral-based retardation effects controlling the fate of metals in subsurface geologic systems. Our recent SCM development workflow, based on the Lawrence Livermore National Laboratory Surface Complexation/Ion Exchange (L-SCIE) database, illustrated a community FAIR data approach to SCM development by predicting uranium(VI)-quartz adsorption for a large number of literature-mined data. Here, we present an alternative hybrid machine learning (ML) approach that shows promise in achieving equivalent high-quality predictions compared to traditional surface complexation models. At its core, the hybrid random forest (RF) ML approach is motivated by the proliferation of incongruent SCMs in the literature that limit their applicability in reactive transport models. Our hybrid ML approach implements PHREEQC-based aqueous speciation calculations; values from these simulations are automatically used as input features for a random forest (RF) algorithm to quantify adsorption and avoid SCM modeling constraints entirely. Named the LLNL Speciation Updated Random Forest (L-SURF) model, this hybrid approach is shown to have applicability to U(VI) sorption cases driven by both ion-exchange and surface complexation, as is shown for quartz and montmorillonite cases. The approach can be applied to reactive transport modeling and may provide an alternative to the costly development of self-consistent SCM reaction databases.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On the prediction of critical heat flux using a physics-informed machine learning-aided framework

The critical heat flux (CHF) corresponding to the departure from nucleate boiling (DNB) crisis is essential to the design and safety of a two-phase flow boiling system. Despite the abundance of predictive tools available to the thermal engineering community, the path for an accurate, robust CHF model remains elusive due to lack of consensus on the DNB triggering mechanism. This work aims to apply a physics-informed machine learning (ML)-aided hybrid framework to achieve superior predictive capabilities. Such a hybrid approach takes advantage of existing understanding in the field of interest (i.e., domain knowledge) and uses ML to capture undiscovered information from the mismatch between the actual and domain knowledge-predicted target. A detailed case study is carried out with an extensive DNB-specific CHF database to demonstrate (1) the improved performance of the hybrid approach as compared to traditional domain knowledge-based models, and (2) the hybrid model’s superior generalization capabilities over standalone ML methods across a wide range of flow conditions. The hybrid framework could also readily extend its applicability domain and complexity on the fly, showing an elevated level of flexibility and robustness. Based on the case study conclusions, the window-type extrapolation mapping methodology is further proposed to better inform high-cost experimental work.

42 ENGINEERING↗

Physics-based hybrid machine learning for critical heat flux prediction with uncertainty quantification

Critical heat flux (CHF) is a key quantity in nuclear system modeling due to its impact on heat transfer, safety margins, and reactor performance. This study develops and validates an uncertainty-aware hybrid modeling approach that combines machine learning with physics-based models to predict CHF in cases of dryout. The Biasi and Bowring empirical correlations were paired with three ML uncertainty quantification (UQ) techniques: deep neural network (DNN) ensembles, Bayesian neural networks (BNNs), and deep Gaussian processes (DGPs). A pure ML model without a base model was evaluated for comparison. Model performance was assessed under plentiful (7,350 points) and limited (9 points) training data scenarios using parity, uncertainty distributions, and calibration curves. Results show that the Biasi hybrid DNN ensemble achieved the best overall performance, with a mean absolute relative error of 1.846%, and well-calibrated uncertainty estimates. The BNN-based hybrids showed slightly higher error (2.14%) but superior uncertainty calibration. DGP models underperformed, with over 6% error and poor uncertainty calibration. All hybrid models outperformed pure machine learning configurations, demonstrating resistance against data scarcity. These findings indicate that hybrid modeling significantly improves predictive accuracy, interpretability, and resilience to data scarcity. The integration of uncertainty awareness provides actionable confidence in CHF predictions, which is vital for safety-critical decisions in nuclear applications. This hybrid approach offers a viable pathway for deploying ML models in reactor analysis tools while preserving domain knowledge and physical consistency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strain-modulated intercalated phases of Pb monolayer with dual periodicity in SiC(0001)-graphene interface

Intercalation of metal atoms at the SiC(0001)-graphene (Gr) interface can provide confined 2D metal layers with interesting electronic properties. The intercalated Pb monolayer (ML) has shown the coexistence of the Gr(10 x 10)-moiré and a stripe phase, which still lacks understanding. Using density functional theory calculation and thermal annealing with ab initio molecular dynamics as motivated by experiment, we have studied the formation energy of Gr/Pb/SiC(0001) for different Pb coverages. Near the coverage of a Pb(111)-like ML mimicking the (10 x 10)-moiré, we find a slightly more stable stripe structure, where one half of the structure has compressive strain with Pb occupying the Si-top sites and the other half has tensile strain with Pb off the Si-top sites. This stripe structure along the Gr zigzag direction has a periodicity of 2.3 nm across the [1$\overline{2}$10] direction agreeing with the previous observations using scanning tunneling microscopy. Analysis with electron density difference and density of states show the tensile region has a more metallic character than the compressive region, while both are dominated by charge transfer from Pb ML to SiC(0001). As a result, the small energy difference between the stripe and Pb(111)-like structures means the two phases are almost degenerate and can coexist, which explains the experimental observations.

36 MATERIALS SCIENCE↗

Novel short antibacterial and antifungal peptides with low cytotoxicity: Efficacy and action mechanisms

Research highlights: {yields} Short antimicrobial peptides with nine and eleven residues were developed. {yields} These peptides show strong bactericidal activity against clinically important bacterial and fungal pathogens. {yields} These peptides exhibit high stability in the presence of salts, and low cytotoxicity. {yields} These peptides exert their action by disrupting membrane lipids. -- Abstract: Short antimicrobial peptides with nine and eleven residues were developed against several clinically important bacterial and fungal pathogens (specifically Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Fusarium solani). Twelve analogues of previously reported peptides BP76 (KKLFKKILKFL) and Pac-525 (KWRRWVRWI) were designed, synthesized, and tested for their antimicrobial activities. Two of our eleven amino acid peptides, P11-5 (GKLFKKILKIL) and P11-6 (KKLIKKILKIL), have very low MICs of 3.1-12.5 {mu}g ml{sup -1} against all five pathogens. The MICs of these two peptides against S. aureus, C. albicans and F. solani are four to ten times lower than the corresponding MICs of the reference peptide BP76. P9-4 (KWRRWIRWL), our newly designed nine-amino acid analogue, also has particularly low MICs of 3.1-6.2 {mu}g ml{sup -1} against four of the tested pathogens; these MICs are two to eight times lower than those reported for Pac-525 (6.2-50 {mu}g ml{sup -1}).These new peptides (P11-5, P11-6 and P9-4) also exhibit improved stability in the presence of salts, and have low cytotoxicity as shown by the hemolysis and MTT assays. From the results of field-emission scanning electron microscopy, membrane depolarization and dye-leakage assays, we propose that these peptides exert their action by disrupting membrane lipids. Molecular dynamics simulation studies confirm that P11-6 peptide maintains relatively stable helical structure and exerts more perturbation action on the order of acyl tail of lipid bilayer.

60 APPLIED LIFE SCIENCES↗

CdSe/ZnS quantum dots based electrochemical immunoassay for the detection of phosphorylated bovine serum albumin

A CdSe/ZnS quantum dot (QD) based electrochemical immunoassay of phosphorylated bovine serum albumin as a protein biomarker is presented. The QDs were used as labels and were conjugated with the secondary anti-phosphoserine antibody in a heterogeneous sandwich immunoassay. First, the primary BSA antibody was immobilized on polystyrene microwells, followed by the addition of BSA-OP. After that, the QD-labeled anti-phosphoserine antibody was added into microwells for immunorecognition. Finally, the bound QD was dissolved in an acid-dissolution step and was detected by electrochemical stripping analysis. The measured current responses were proportional to the concentration of BSA-OP. Under optimal conditions, the voltammetric response was linear over the range of 0.5 - 500 ng mL-1 of BSA-OP, with a detection limit of 0.5 ng mL-1 at a deposition potential of -1.2 V for 120 s. It also shows good reproducibility with a relative standard deviation of 8.6% of six times determination of 25 ng mL-1 of BSA-OP. This QD-based electrochemical immunoassay offers great promise for simple and cost-effective analysis of protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

SAXS Assistant: Automated SAXS analysis for structural discovery in biologics and polymeric nanoparticles

Small-angle x-ray scattering (SAXS) is a powerful technique for assessing macromolecular structure. High-throughput SAXS is limited by the time-consuming and, at times, subjective nature of SAXS data interpretation. Here, we present SAXS Assistant, a Python-based script that streamlines SAXS data analysis to extract features for machine learning (ML) and key structural parameters, including the Guinier radius of gyration (R g ), pair distance distribution function (PDDF)-derived R g , maximum particle dimension (D max ), and Kratky plots. The script builds upon BioXTAS RAW and validates reliability via Guinier/PDDF R g agreement, an important indicator of well-measured data sets. For assistance in D max estimation, a multilayer perceptron regressor was trained with 1940 data files from the Small Angle Scattering Biological Data Bank. The model achieved a test set performance R 2 = 0.90 and mean absolute error = 11.7 Å. Training exclusively with experimental data translates analyses from researchers, including experts in the field, to the ML model, which helps assess D max estimations from PDDF. Gaussian mixture model clustering was implemented to classify profiles into structural classes based on entries in the Small Angle Scattering Biological Data Bank. Users may therefore assess the similarity between experimental samples and known biomolecular shapes within the mapped repository entries. This probabilistic clustering aids in quantifying information from Kratky and generating shape-descriptive features. SAXS Assistant accelerates SAXS data analysis through enforced quality control, ML-ready outputs, and flags for low-confidence results. In addition to providing the ability to analyze large data sets at high throughput, this tool is versatile and may serve researchers in both biological and synthetic polymer research fields.

36 MATERIALS SCIENCE↗