Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Optical transient grating pumped X-ray diffraction microscopy for studying mesoscale structural dynamics

Abstract A fundamental understanding of materials’ structural dynamics, with fine spatial and temporal control, underpins future developments in electronic and quantum materials. Here, we introduce an optical transient grating pump and focused X-ray diffraction probe technique (TGXD) to examine the structural evolution of materials excited by modulated light with a precisely controlled spatial profile. This method adds spatial resolution and direct structural sensitivity to the established utility of a sinusoidal transient-grating excitation. We demonstrate TGXD using two thin-film samples: epitaxial BiFeO 3 , which exhibits a photoinduced strain (structural grating) with an amplitude proportional to the optical fluence, and FeRh, which undergoes a magnetostructural phase transformation. In BiFeO 3 , structural relaxation is location independent, and the strain persists on the order of microseconds, consistent with the optical excitation of long-lived charge carriers. The strain profile of the structural grating in FeRh, in comparison, deviates from the sinusoidal excitation and exhibits both higher-order spatial frequencies and a location-dependent relaxation. The focused X-ray probe provides spatial resolution within the engineered optical excitation profile, resolving the spatiotemporal flow of heat through FeRh locally heated above the phase transition temperature. TGXD successfully characterizes mesoscopic energy transport in functional materials without relying on a specific transport model.

36 MATERIALS SCIENCE↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Toward Å-fs-meV Resolution in Electron Microscopy: Systematic Simulation of the Temporal Spread of Single-Electron Packets

Though efforts to improve the temporal resolution of transmission electron microscopes (TEMs) have waxed and waned for decades, with relatively recent advances routinely reaching sub-picosecond scales, fundamental and practical challenges have hindered the advance of combined Å-fs-meV resolutions, particularly for core-loss spectroscopy and real-space imaging. This is due in no small part to the complexity of the approach required to access timescales upon which electrons, atoms, molecules, and materials first begin to respond and transform – attoseconds to picoseconds. Here we present part of a larger effort devoted to systematically mapping the instrument parameter space of a TEM modified to reach ultrafast timescales. With General Particle Tracer, we studied the statistical temporal distributions of single-electron packets as a function of various fs pulsed-laser parameters and electron-gun configurations and fields for the exact architecture and dimensions of a Thermo Fisher Tecnai Femto ultrafast electron microscope. We focused on easily-adjustable parameters, such as laser pulse duration, laser spot size, photon energy, Wehnelt aperture diameter, and photocathode size. In addition to establishing trends and dispersion behaviors, we identify regimes within which packet duration can be 100s of fs and approach the 300-fs laser limit employed here. Overall, the results provide a detailed picture of the temporal behavior of single-electron packets in the Tecnai Femto gun region, forming the initial contribution of a larger effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of transmission high energy electron microscopy

Charged particle radiography with 800 MeV protons has been used for decades at LANL and developed around the world to study dynamic material properties. Recently, charged particle radiography has been demonstrated with the use of high-energy electrons. Because of the difference in the mass of the electron compared to the mass of the proton, the radiographic processes are substantially different and well suited to the study of fast dynamic processes in relatively thin systems. This presentation will show the layout required for such measurements, along with data collected from this recent demonstration performed with 14 GeV electrons generated at the SLAC National Accelerator Laboratory. The radiographic performance for flash measurements will be presented, along with the limitations of this measurement technique.

Merrill, F. E.↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Uncovering surface plasmon optical resonances in nanohole arrays through interferometric photoemission electron microscopy

In this work, the role of surface plasmon polaritons (SPPs) in nanohole array optical extinction spectra is explored using a time-resolved technique capable of isolating the air/metal interfacial SPP contribution to the typical Fano profile in optical transmission curves. A pair of interferometrically locked broad-band femtosecond pulses is used to launch SPPs from lithographically patterned plasmonic nanohole arrays. SPPs launched in the co- and counter-propagating directions are probed using a third probe pulse in a photoemission electron microscope. Using this approach, we record interferometric SPP–SPP linear autocorrelations that selectively report on the resonances of SPPs launched from arrays of varying pitches and hole diameters. Aside from advancing an approach to selective SPP spectroscopy, we illustrate that resonant coupling in the counter-propagating direction may be exploited to control the spatial, temporal, and spectral characteristics of SPPs. For the counter-propagating direction, we show that tuning the array pitch near the fundamental plasmon resonance generates color-tuned (~770–820 nm), narrow bandwidth SPPs, and the bandwidth may be controlled by changing the ratio of pitch to hole diameter. The SPP resonances we recover through Fourier transforms of the interferometric autocorrelations shed light on the classical problem of Fano interference in nanohole array extinction spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementing microwave impedance microscopy in a dilution refrigerator

We report the implementation of a dilution refrigerator-based scanning microwave impedance microscope with a base temperature of ∼100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using this setup, we have demonstrated the imaging of quantum anomalous Hall states in magnetically (Cr and V) doped (Bi, Sb)2Te3 thin films grown on mica substrates. Both the conductive edge modes and topological phase transitions near the coercive fields of Cr- and V-doped layers are visualized in the field-dependent results. Our study establishes the experimental platform for investigating nanoscale quantum phenomena at ultralow temperatures.

Instruments & Instrumentation↗

Cryoelectron microscopy structure and mechanism of the membrane-associated electron-bifurcating flavoprotein Fix/EtfABCX

Significance Electron bifurcation is a recently recognized mechanism of biological energy conservation that is widespread in anaerobic microorganisms and provides low-potential, high-energy electrons to drive otherwise nonspontaneous metabolic reactions. Here we describe the structure of a membrane-associated bifurcating enzyme from an aerobic microorganism. Termed Fix/EtfABCX, this enzyme is used by some nitrogen-fixing microbes to drive the low-potential reduction of nitrogen gas to ammonia. Fix/EtfABCX is a superdimer and a catalytic mechanism is proposed involving six flavins, two of which bifurcate, four iron-sulfur clusters, and two menaquinones. Fix/EtfABCX shares structural similarity with mammalian quinone oxidoreductase involved in mitochondrial fatty acid oxidation, suggesting an unexpected evolutionary link between bifurcating and nonbifurcating systems.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution cryo-electron microscopy structure of photosystem II from the mesophilic cyanobacterium, Synechocystis sp. PCC 6803

Significance Photosystem II (PSII) is a photo-oxidoreductase that harnesses light energy to use water to make fuel. Water oxidation occurs at a metal cluster in the active site called the oxygen-evolving complex (OEC). Understanding PSII function has provided design principles for synthetic solar fuel catalysts; however, the details of water oxidation are obscured by the multiple states through which the mechanism proceeds, differences between species, and lability of the OEC. To better understand PSII function, we solved its structure from Synechocystis sp. PCC 6803. We observe significant differences compared with PSII from thermophilic cyanobacteria that highlight the need for reexamination of previous data using this structure for interpretation. The structure also provides a platform for studies of site-directed mutations of PSII.

PsbV↗

Foliar elemental distribution in Blepharidium guatemalense assessed by synchrotron X-ray fluorescence spectroscopy and colorimetric optical microscopy

The hyperaccumulation phenomenon holds significant potential for Ni agromining in ultramafic areas; however, data on tropical hyperaccumulator species, particularly regarding metal distribution and tolerance mechanisms, remain scarce. Here, this study characterized the foliar elemental distribution of Blepharidium guatemalense, analyzed its metal localization at both tissue and cellular levels, and quantified its Ni accumulation when grown in Brazilian ultramafic soil. Plants were grown in pots for 90 days, and Ni concentrations in the aerial biomass and bio-ore were determined. Synchrotron-based micro-X-ray fluorescence (S-µXRF) was used to assess metal distribution in tissues, supplemented by microscopic examination with dimethylglyoxime (DMG) to visualize Ni accumulation in specific cell types. B. guatemalense reached 19,000 mg kg −1 Ni in leaves. Processing leaf biomass produced ash containing 24 wt% Ni, indicating promising metal-recovery potential for the species. S-µXRF revealed that Ni was predominantly localized in the central and secondary veins of the leaves, suggesting efficient vascular transport. Microscopic analysis using the colorimetric reagent DMG further showed that Ni accumulation occurs near the epidermis and phloem, suggesting that B. guatemalense employs specific physiological mechanisms for Ni translocation, potentially supporting both defense and growth functions. These results establish B. guatemalense as a promising candidate for large-scale Ni agromining in tropical regions.

36 MATERIALS SCIENCE↗