Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROBIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗

Carbon Limited Soils of Iceland: Analogs for Identifying Carbon-Mineral Interactions in Gale Crater, Mars Surface Materials

The Mars Science Laboratory’s Curiosity rover mission to Gale Crater, Mars has a goal to search for organic carbon and corresponding evidence of ancient microbiology preserved in clay mineral-rich sedimentary deposits [1]. No clear correlation of clay mineral (smectite) abundances with the Sample Analysis at Mars (SAM) carbon detections (up to 2000 ppm C) [2] has been established, suggesting other phases may preserve organic C in martian sediments. Terrestrial volcanic glass soils can accumulate C due to the C-complexing abilities of poorly crystalline Al- and Fe-oxyhydroxides [3]. The Xray amorphous component (20 to 73 wt. %) in Gale Crater materials [4,5] has received little consideration regarding organic C preservation in Gale Crater. The objectives of this work are to 1) Evaluate C content and level of soil development of basaltic glass-bearing Icelandic soils to determine the role that poorly crystalline phases have in complexing organic C in carbon limited soils and 2) Determine if evolved gas analysis (EGA) of well-characterized Mars analog basaltic materials from Iceland can be used to interpret SAM data to understand the nature of organic-C mineral/geochemical associations in Gale materials.

B. Sutter↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E Z Klier↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

Recommendations for Developing Space Suit Integrated Food Systems and Delivering Nutrition Before, During, and After Lunar EVA

INTRODUCTION Artemis missions will include a higher tempo and frequency of extravehicular activities (EVAs) than any previous space program. Because of the physical demands expected from the crew, future space suit designs are required to incorporate nutritional support to the astronauts during lunar surface EVAs lasting longer than 4 hours. The purpose of this project was to provide recommendations to aid the development of an in-suit system that can adequately, safely, and acceptably deliver nutrition to a crewmember while confined to a space suit during EVA. METHODS Physiological, logistical, and engineering aspects of potential in-suit nutrition approaches were assessed through literature reviews, assessments of commercial off the shelf (COTS) foods, suit volumetric modeling, and feedback from subject matter experts and crewmembers. Key driving factors in the development of in-suit nutrition requirements included how much and what type of nutrition should be included, what food formulations are appropriate and safe, what are inherent limitations of space suits, what are the potential risks to the crewmember in the suit, and what practices and preferences from astronauts should be considered. Design references were conceptualized and assessed for strengths and limitations as potential in-suit nutrition systems for surface EVA. RESULTS Acute exogenous energy demands vary greatly depending on activity intensity and duration, and partial energy replenishment (i.e., 60–80 kcal∙hr-1 of EVA, or 460–680 kcal for EVAs lasting up to 8 hours) during activities could improve performance, safety, and recovery. COTS foods capable of providing these energy requirements exist; however, no COTS foods have been identified that pass NASA flight standards for microbiological safety and stability. In-suit nutrition delivery design references that were considered included in-suit concepts for a prefilled drink bag, a hydratable drink bag, and a solid food stick. In addition, a helmet feed port concept was considered for use with drink bags external to the suit. Volumetric models of the in-suit drink bag concepts, based on xEMU dimensions, indicate challenges of fitting formulations > 200 ml (equating to approximately 200 kcal). Astronaut feedback on the four concepts indicated that despite some individual preferences for inclusion of solid foods and helmet port designs, the prefilled drink bag concept was the most preferred. A prefilled drink bag can only be used if food safety and stability can be ensured, possibly requiring advancements in food delivery hardware. CONCLUSION The ability to meet the increased need for nutrition during surface EVAs through provision of nutrients in the suited configuration would benefit overall crew health, performance, and morale, and thus increase the likelihood of mission success. It is recommended that in-suit nutrition capabilities provide at least 400–600 kcal within the suit during EVAs lasting > 4 hours and that suit designs include a dedicated volume for food grade nutrition systems. The developed food system should either allow for 1) installation of prefilled (sealed sterile) liquid nutrition in the suit and provide a mechanism to break the seal at the time that consumption is desired or 2) demonstrate that the unsealed food product shelf life allows for safe consumption after at least 12 hours of EVA.

space suit↗

Nanopore Sequencing-Based Microbial Air Profiling Method for Crewed Spacecraft

Microbial monitoring of the International Space Station (ISS) atmosphere is vital to maintaining the health of the spacecraft and crew. Key to NASA’s microbial risk assessment is the identity of contaminating microorganisms in the environment. Historically, this has been achieved through impaction-based air sampling followed by culture. Identification of the microorganisms present requires sample return to Earth and lab-based analyses. While this culture-based approach has served to provide alerts to anomalies and overall confidence in the controls in place, it is not suitable for exploration missions with no sample return. Recently, significant advancements in molecular-based microbial monitoring via nanopore sequencing have been implemented onboard the ISS. Building on this work, multiple commercially available air samplers, compatible with downstream molecular analysis, were evaluated for use in the spaceflight environment. Through this assessment, the Coriolis Compact (Bertin Technologies), which uses cyclonic technology to collect bioaerosols onto the surface of a sterile cone, was selected for a larger-scale comparison to the current culture-based monitoring method. Using the Coriolis Compact, 1000 L of air was collected from the breakroom of an office building and a fitness center. The buffer used to dissociate the microbial cells from the surface of the cone was split between the NASA Microbiology Laboratory’s standard culture and Sanger sequencing-based method and the culture-independent nanopore sequencing method. The bacteria identified through culture were present in the nanopore data, with Micrococcus, Staphylococcus, and Moraxella being the most common cultured isolates, which is expected based on the media and growth conditions. Not surprisingly, the nanopore data yielded much higher diversity and paralleled that of previous atmospheric microbiome studies of human-occupied built environments. As compared to the culture-based data where the breakroom and fitness center data sets cluster in proximity, the nanopore data depicts the contrast of these atmospheric microbiomes. Moreover, the nanopore data were sufficient to meet NASA’s risk assessment needs and noted the culturable isolates routinely observed. This nanopore-based atmospheric microbial profiling method will enable near real-time environmental monitoring of crewed spacecraft as future missions extend beyond low-Earth orbit.

Brandon Dunbar↗

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

Artemis IV International Gateway Biological Payloads

1. Microbiology of the Built Environment (MoBE) - Sponsor: SMD Biological and Physical Science Division (BPS), Space Biology Program - Status as of 2021: - a. Paused in 2021, pending ESDMD’s Logistics Module Decision - b. Payload proposed by BPS and developed by the DWG and Partner Agencies - c. Submitted to Gateway Program Mission Integration and Utilization for feasibility review - d. GPCB ATP package produced and on pause - e. Research solicitation will be international 2. Gateway Research Accommodation Bag 1. Sponsor: ESA 2. BPS Space Biology Program intending to fly a passive experiment - Payload is TBD

Kevin Sato↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Overview of the Inaugural Space Health Impacts for the NASA Experience (SHINE) Training Program – Virtual Space Radiation Curriculum

The Space Radiation Element part of NASA Human Research Program initiated a virtual, annual space radiation curriculum. The SHINE space radiation curriculum aims to educate participants not only in the scientific aspects of space radiation but also in the agency’s risk management strategies. SHINE combines weekly seminars by speakers from NASA, other government agencies, academia, and industry, with networking sessions designed to foster collaboration between participants and interactions with NASA scientists. A total of 59 applications were received from which 25 participants were selected. The 25 participants, with citizenship from a total of 8 countries, are composed of 5 graduate students, 4 postdocs, 11 scientists and 5 professors/medical doctors. Participants have a wide range of expertise including molecular and cellular biology, microbiology, botany, physiology, engineering, physics, aerospace medicine, planetary science, biostatistics, and modeling. The inaugural course ran weekly from February 2023 to August 2023 and was comprised of lectures, less formal coffee hours and office hours. The topics covered ranged from space environments to health effects to granting opportunities. The second annual SHINE training program is scheduled from February to August 2024. In addition, a separate competitive practicum session, to allow participants to gain hands-on radiation experience, will be held Fall 2024 at the NASA Space Radiation Laboratory (NSRL).

Janice A. Zawask↗

Unlocking the Spacecraft and Human Habitat Microbiome to Enable the Next Generation of Space Exploration

Planetary protection is the discipline that prevents harmful contamination of the solar system during exploration activities. The current international guidelines and NASA policy addressing biological contamination on spacecraft surfaces contains prescriptive guidelines of spore requirements (e.g., 300 spores/m2, 5×105 spores per spacecraft) applicable to spacecraft bound for Mars. To verify these requirements spacecraft engineers sample spacecraft surfaces throughout the assembly, test and launch operations phase of the mission using damp water cotton swabs and polyester wipes. After sampling, the potential biological contamination is enumerated using a series of traditional microbiology techniques to include sonication, heat shocking at 80°C for 15min to select for spores, and growth on tryptic soy agar at 32°C for 72 hours. To enable crewed missions to Mars and robotic exploration of the Ocean Worlds a risk informed decision making / performance-based approach to assess biological contamination offers a promising solution in the trade space. Recognizing the need for a performance-based approach, NASA’s new Planetary Protection policies now incorporate the agility for missions to be able to leverage a performance or prescriptive approach. One of top contenders in the option space is a coupled quantitative, descriptive and functional based approach to be able to assess the quantity, types and capabilities of the biological contamination present on spacecraft surfaces. A tailored, mission by mission assurance case could then be formulated by building an argument around the target body, projected capabilities surrounding the types of organisms their potential for survival and proliferation, and ability to be transported on the target body to contaminate an area of biological interest. A performance-based requirement would then be used to demonstrate the mission’s compliance in protecting the planetary environment safety objectives. This symposium talk will showcase the background and need case for NASA to develop such a capability as well as provide an update on the efforts underway in developing a transparent and responsible performance-based approach to biological contamination assessments on spacecraft surfaces.

Habitat Microbiome↗

Novel Microgreen Crop Testing for Space

Long-duration missions beyond low-Earth orbit will encounter challenges in maintaining adequate nutrition and crew acceptability in the food system. In situ production of fresh produce can supplement nutrient deficiencies in the prepackaged diet. Currently, there are a relatively small number of crops that can be reliably grown in space for space crop production efforts. An intriguing area of new investigation involves novel types of microgreens that have the potential to be sources of calories, fat, carbohydrates, and protein. These sources of nutrition are not obtainable in significant quantities with current pick and eat crops. Many microgreen cultivars are also sources of nutrients of interest, such as Vitamins B1, C, and K, and elements such as potassium. Microgreens should be selected to address specific nutritional deficits, as identified by NASA’s Human Research Program, with an emphasis on having a diversity of crops to meet nutritional requirements and crew acceptability. To achieve this, the concept of Crop Readiness Level (CRL) has been developed to gauge readiness of crops for spaceflight applications. CRL includes assessing environmental compatibility, food safety considerations, relevant nutritional analysis, and sensory analysis. Recent testing at Kennedy Space Center has focused on advancing the CRL of a variety of novel microgreens. These varieties were grown under 150 µmol m -2 s -1 PPFD from LED lights, 3000 ppm CO 2 , and 23°C to simulate an ISS environment. Crops were harvested and yield was assessed. Then, baseline microbiological and nutritional analysis (Vitamins B1, C, K; mineral analysis; proximate analysis) and sensory evaluation were performed. These baseline data are essential to selecting candidate crops for future missions and assessing crop production hardware and changes in environmental conditions on future crop performance and nutritional quality.

nutrition↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems – Update 2023

A spacecraft water disinfection system, suitable for extended length space exploration, should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements, be chemically compatible with all materials in contact with the water, be safe for human consumption, and be suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum potable water biocide under investigation for future exploration missions. The competing technology for dosing silver ions in future water systems is based on actively dosing the ions via electrolytic production. Several challenges with this approach have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the continued development of a nanoparticle/polyurethane (NP/PU) composite foam for the controlled release of silver ions and is intended to build upon the 2022 International Conference on Environmental Systems (ICES) paper number 97. This paper provides the technical background and performance test results (ongoing long-term silver ion release testing and product variability testing) from the silver chloride (AgCl) NP/PU composite foams. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia D. Irwin↗

Overview of The Inaugural Space Health Impacts for the NASA Experience (SHINE) Training Program – Virtual Space Radiation Curriculum

The Space Radiation Element of the NASA Human Research Program initiated a virtual, annual space radiation curriculum. The Space Health Impacts for the NASA Experience (SHINE) space radiation didactic curriculum aims to educate participants not only in the scientific aspects of space radiation but also in the agency’s risk management strategies. SHINE combines weekly seminars by speakers from NASA, other government agencies, academia, and industry, with networking sessions designed to foster collaboration between participants and interactions with NASA scientists and HRP funded investigators. The inaugural course ran weekly from February 2023 to August 2023 and was comprised of lectures, less formal coffee hours and office hours. The SHINE topics ranged from space environments to health effects and countermeasure to granting opportunities. Participants developed beam time proposals for real, proposed, or potential experiments at the NASA Space Radiation Laboratory (NSRL) at the Brookhaven National Laboratory. For the 2023 course, a total of 59 applications were received from which 25 participants were selected. Selected participants were citizens from 8 countries and comprised 5 graduate students, 4 postdocs, 11 scientists and 5 professors/medical doctors. Participants had a wide range of expertise including molecular and cellular biology, microbiology, botany, physiology, engineering, physics, aerospace medicine, planetary science, biostatistics, and modeling. The second annual SHINE training program is scheduled from February to August 2024. In addition, a separate SHINE space radiation practicum session, to allow participants to gain hands-on radiation experience, will be held Fall 2024 at the NSRL.

Radiation↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗