Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Time, geodesy, and astrometry: Results from radio interferometry

The results from a total of a dozen transcontinental and intercontinental VLBI experiments are discussed. Particular emphasis is placed on: (1) the inferred behavior of the frequency standards, usually hydrogen masers, on time scales from 10 to 100,000 seconds; (2) the estimated celestial positions of the observed radio sources; (3) the determinations of the vector baselines; and (4) the inferred values of polar motion and UT.1.

Clark, T. A.↗

Bonding of sapphire to sapphire by eutectic mixture of aluminum oxide and zirconium oxide

Bonding of an element comprising sapphire, ruby or blue sapphire to another element of such material with a eutectic mixture of aluminum oxide and zirconium oxide is discussed. The bonding mixture may be applied in the form of a distilled water slurry or by electron beam vapor deposition. In one embodiment the eutectic is formed in situ by applying a layer of zirconium oxide and then heating the assembly to a temperature above the eutectic temperature and below the melting point of the material from which the elements are formed. The formation of a sapphire rubidium maser cell utilizing eutectic bonding is shown.

Deluca, J. J.↗

A review of precision oscillators

Precision oscillators used in PTTI applications include quartz crystal, rubidium gas cell, cesium beam, and hydrogen maser oscillators. A general characterization and comparison of these devices is given including accuracy, stability, environmental sensitivity, size, weight, power consumption, availability and cost. Areas of special concern in practical applications are identified and a projection of future performance specifications is given. An attempt is made to predict physical and performance characteristics of new designs potentially available in the near future.

Hellwig, H.↗

Application of very long baseline interferometry to Astrometry and Geodesy: effects of frequency standard instability on accuracy

The accuracy of geodetic and astrometric information obtained from very long baseline interferometry (VLBI) observations is dependent upon the stability of the frequency standard, or clock, used at each site of VLBI array. The sensitivities of two hydrogen maser frequency standards of different design to pressure, temperature, and magnetic field variations were measured; and, for one of the standards, sensitivity was found to be severe enough to degrade the information content of VLBI measurements. However, the effect on the geometric and astrometric information of such clock instabilities, with time scales of hours or greater, can be sharply reduced through the use of differencing techniques.

Clark, T. A.↗

Infrared, X-ray, and XUV astrophysics

An observational program covering wavelengths from the near infrared to 1 millimeter is reviewed. The program of millimeter observations largely consisted of analyzing previous observations since the summer humidity was too high for new observations. Maps of millimeter emission from W3, Sgr B2, W49 and M42 were made. Five extragalactic sources were detected and are discussed. Energy distributions of several of the discrete sources at the Galactic Center were studied. A 5-year visual/infrared program on Markarian galaxies is discussed which showed the presence of both thermal and nonthermal infrared radiation sources and established correlations between the infrared sources and the emission line regions. The Nova Cygnus 1975, caught during its rise as well as subsequent dimming, is also discussed. Several other continuing programs are described, including studies of dark clouds and CO maser sources.

Source record↗

Atomic frequency standard relativistic Doppler shift experiment

An experiment has been performed to measure possible space anisotropy as it would effect the frequency of a cesium atomic beam standard clock in a laboratory on earth due to motion relative to external coordinate frames. The cesium frequency was measured as a function of orientation with respect to an atomic hydrogen maser standard. Over a period of 34 days 101 measurements were made. The results are consistent with a conclusion that no general orientation dependance attributable to spacial anisotropy was observed. It is shown that both the airplane clock results, and the null results for the atomic beam clock, are consistent with Einstein general or special relativity, or with the Lorentz transformations alone.

Peters, H. E.↗

Radio detection of interstellar sulfur dioxide

Interstellar sulfur dioxide (SO2) has been detected in emission from the direction of the Orion Nebula molecular cloud and from Sgr B2. SO2 is the heaviest interstellar molecule detected to date, and the only nonlinear triatomic molecule which does not contain hydrogen. The remarkable Orion emission profiles suggest that two components are supporting the SO2 emission: a dense circumstellar-type envelope, which may be in maser emission, and a warm galactic cloud component.

Snyder, L. E.↗

Observations of 1-millimeter continuum radiation from the DR 21 region

Continuum emission at 1 mm has been mapped with 1-min resolution over a 3-min by 8-min area including the compact H II region DR 21, the maser source W75(S)-OH, and the central portions of the surrounding molecular cloud. Peaks in the 1-mm intensity are observed at the positions of DR 21 and W75(S)-OH, and are roughly coincident with less marked peaks in the intensity of HCN and CO emission. An extended component of 1-mm emission is present as well. The principal source of 1-mm radiation is thought to be thermal emission from dust within the molecular gas. The characteristics of this radiation which make it a promising tool for the study of molecular clouds are briefly discussed.

Werner, M. W.↗

A 100-kHz frequency divider, distribution amplifier

A frequency divider, distribution amplifier module having low phase noise and low phase drift with temperature and high isolation between outputs was developed for use in the hydrogen maser frequency standard, where it divides 1 MHz from the previous frequency divider down to 100 kHz and provides four transistor-transistor logic (TTL) outputs.

Lutes, G.↗

DSN research and technology support

Continuing testing and refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine pulsar observations of 22 pulsars. Radar observations of geostationary satellite are discussed. Current status of the 400-kW X-band radar is reported along with routine automatic testing of the stability-reliability of the DSS 13 maser-receiver noise adding radiometer combination. A failure in the Faraday rotation receiving system is noted along with discussion in some detail of the activities of the high power transmitter maintenance facility. Continuation of receiver phase stability testing, specifically the effects of temperature on coaxial cables, is discussed and results reported. A demonstration at full power of the microwave power transmission facility is noted and routine support of the planetary radio astronomy experiment is discussed. Transmission of master clock synchronization signals to overseas DSN stations is also reported.

Jackson, E. B.↗

DSN research and technology support

The activities of the Venus Station (DSS 13) and the Microwave Test Facility (MTF) during the period April 19 through June 13, 1976, are discussed and progress noted. Continuing reliability testing and computer program refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine observations of 17 pulsars. Radar observations of a geostationary satellite are reported, along with the routine automatic testing of the stability of the DSS 13 maser-receiving system. Additional testing of thermal characteristics of semiflexible coaxial cables is reported, along with phase stabilization measurements thereon. Routine support of the planetary radio astronomy experiment, with 43.25 hours of observations of Jupiter and various radio calibration sources, is reported, along with 18.75 hours of differential VLBI observations in conjunction with Australia, DSS 43. Modifications of the clock synchronization winterization system are reported, along with a discussion of the activities of the DSN High-Power Transmitter Maintenance Facility.

Jackson, E. B.↗

Confirmation of interstellar N2H/+/

The proposed identification of the triplet of interstellar lines recently discovered at 93.174 GHz with the molecular ion N2H(+) is confirmed by resolving the predicted hyperfine structure of the inner nitrogen nucleus in the narrow-line molecular source OMC-2 in the Orion Nebula. The hyperfine constants of N2H(+) are derived from the observational data, and the rest center frequency of the J = 1-0 rotational transition is determined. It is noted that the full width at half-maximum of the weakest line (F sub 1 = 0-1) is only 230 kHz (0.74 km/sec in radial velocity), making it the narrowest molecular emission line (excluding maser point sources) thus far observed in the direction of a H II region or IR source.

Thaddeus, P.↗

Radio continuum measurements of compact H II regions and other sources

Results are reported for measurements of the flux densities of 33 sources at wavelengths of 13, 4, and 2 cm, which were conducted using the NASA/JPL Deep Space Network 64-m antenna at Goldstone, Calif. Besides compact H II regions, the sources included five Uhuru X-ray sources, several IR sources, an extragalactic radio source, and a H2O maser. The Lyman continuum flux is derived from the measured radio flux and the assumed distance and temperature for 10 possible H II regions; the spectra of previously known sources are extended to higher frequencies, and upper limits are placed on the flux densities for the five X-ray sources. New compact H II regions are found in the bright nebula M78, the nebula K5, and the Ophiuchus dark cloud/IR region.

Matsakis, D. N.↗

Interstellar molecules

Progress in the discovery and study of interstellar molecules is summarized. The 36 molecular species thus far identified in interstellar space are listed in several groups which include simple hydrides, oxides, and sulfides, various derivatives of ammonia, molecules involving linear carbon chains, cyanides, and molecules related in structure to formaldehyde, alcohols, or ethers. Several free radicals are described, the discovery of molecules in external galaxies is discussed, and possible mechanisms for molecular formation are noted. Methods for examining relative isotopic abundances by measuring molecules in interstellar clouds are outlined, mechanisms for the excitation of interstellar molecules are reviewed, and values are presented for the C-12/C-13 abundance ratio in a number of interstellar clouds. The detection of interstellar masers is discussed along with pumping mechanisms and masing transitions in H2CO, CH, OH, and SiO. The nature of dense interstellar clouds is examined in terms of several simple and complex cloud models, with emphasis on multiple condensation models.

Townes, C. H.↗

Infrared spectrophotometry of OH 231.8 + 4.2 identified with OH 0739-14

Infrared spectrophotometry from 2.1 to 4.1 microns and from 7.7 to 13.3 microns of the peculiar OH maser source OH 231.8 + 4.2 identified with OH 0739-14 is reported. Deep absorption features are found at 3.1 microns and from 8 to 13 microns, and are identified with absorption by cold ices and silicates in the line of sight to the infrared source. The infrared flux is also found to vary. These infrared observations present new difficulties in understanding the nature of the object. Several possibly useful observations of OH 231.8 + 4.2 are suggested.

Gillett, F. C.↗

Ultrastable-frequency distribution system

System automatically compensates for path perturbations between transmitter (master) and receiver (slave) sites, and thereby allows single source, such as a hydrogen maser, to serve as frequency reference for multiple users. Highly accurate reference can be transmitted at cost much lower than for sophisticated onsite frequency standard.

Macconnell, J. W.↗

Measuring cryogenic-refrigerator cooling capacity

Temperature-sensing bridge determines liquid reserve level in low-temperature heat exchanger. Device should be of interest to manufacturers of cryogenic refrigerators as well as to those who use them in conjunction with operation of electronic equipment like masers or Josephson junctions.

Wiebe, E. R.↗

Preliminary demonstration of precision DSN clock synchronization by radio interferometry

A wideband digital data acquisition system has been developed to measure the clock offsets to the 10-ns accuracy required to facilitate three-way spacecraft ranging, to monitor the hydrogen maser frequency standard rates to 1 part in 10 to the forteenth power and to potentially reduce operational costs by replacing the current DSN operational time sync system.

Hurd, W. J.↗