Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

First results and planned experiments with the INFN-LNS ray-tracing magnetic spectrometer MAGNEX

The MAGNEX large-acceptance ray-tracing magnetic spectrometer has recently been used with beams from the INFN-LNS Tandem accelerator. After an accurate commissioning, the instrument has started an ambitious experimental program. In the first experiment the {sup 19}F({sup 7}Li,{sup 7}Be){sup 19}O charge-exchange reaction was studied at 52 MeV incident energy. The {sup 19}O excitation energy spectrum was reconstructed and the angular distributions measured. The second experiment was aimed at the study of the {sup 15}C via the {sup 13}C({sup 18}O,{sup 16}O){sup 15}C reaction at 84 MeV incident energy. The ejectiles where detected at forward angles and mass identified by means of an innovative technique. The {sup 15}C excitation energy spectra up to about 20 MeV were obtained with a 250 keV FWHM energy resolution. In addition to several known states, the spectra show two unknown resonant-like structures at 11.4 and 14.0 MeV. The strong population of these structures, together with the measured widths, could indicate the collective nature of these states associated to a correlated neutron pair transfer. Besides the first results of physical interest from these two experiments, future experiments with MAGNEX are briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electromagnetic Effects in SDF Explosions

The notion of high ion and electron concentrations in the detonation of aluminized explosive mixtures has aroused some interest in electro-magnetic effects that the SDF charges might generate when detonated. Motivated by this interest we have started to investigate whether significant electro-magnetic effects show up in our small-scale experiments. However, the design of instrumentation for this purpose is far from straightforward, since there are a number of open questions. Thus the main aim of the feasibility tests is to find - if possible - a simple and reliable method that can be used as a diagnostic tool for electro-magnetic effects. SDF charges with a 0.5-g PETN booster and a filling of 1 g aluminum flakes have been investigated in three barometric bomb calorimeters with volumes ranging from 6.3 l to of 6.6 l. Though similar in volume, the barometric bombs differed in the length-to-diameter ratio. The tests were carried out with the bombs filled with either air or nitrogen at ambient pressure. The comparison of the test in air to those in nitrogen shows that the combustion of TNT detonation products or aluminum generates a substantial increase of the quasi-steady overpressure in the bombs. Repeated tests in the same configuration resulted in some scatter of the experimental results. The most likely reason is that the aluminum combustion in most or all cases is incomplete and that the amount of aluminum actually burned varies from test to test. The mass fraction burned apparently decreases with increasing aspect ratio L/D. Thus an L/D-ratio of about 1 is optimal for the performance of shock-dispersed-fuel combustion. However, at an L/D-ratio of about 5 the combustion still yields appreciable overpressure in excess of the detonation. For a multi-burst scenario in a tunnel environment with a number of SDF charges distributed along a tunnel section a spacing of 5 tunnel diameter and a fuel-specific volume of around 7 l/g might provide an acceptable compromise between optimizing the combustion performance and keeping the number of elementary charges low. Further tests in a barometric bomb calorimeter of 21.2 l volume were performed with four types of aluminum. The mass fraction burned in this case appeared to depend on the morphology of the aluminum particles. Flake aluminum exhibited a better performance than granulated aluminum with particle sizes ranging from below 25 {micro}m to 125 {micro}m for the coarsest material. In addition, a feasibility study on electro-magnetic effects from SDF charges detonated in a tunnel has been performed. A method was developed to measure the local, unsteady electro-conductivity in the detonation/combustion products cloud. This method proved to yield reproducible results. A variety of methods were tested with regard to probing electro-magnetic pulses from the detonation of SDF charges. The results showed little reproducibility and were small compared to the effect from pulsed high voltage discharges of comparatively small energy (around 32 J). Thus either no significant electromagnetic pulse is generated in our small-scale tests or the tested techniques have to be discarded as too insensitive or too limited in bandwidth to detect possibly very high frequency electro-magnetic disturbances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically detected magnetic resonance of nitrogen vacancies in a diamond anvil cell using designer diamond anvils

Optically detected magnetic resonance of nitrogen vacancy centers in diamond offers a route to both DC and AC magnetometry in diamond anvil cells under high pressures (>3 GPa). However, a serious challenge to realizing experiments has been the insertion of microwave radiation into the sample space without screening by the gasket material. We utilize designer anvils with lithographically deposited metallic microchannels on the diamond culet as a microwave antenna. We detected the spin resonance of an ensemble of microdiamonds under pressure and measured the pressure dependence of the zero field splitting parameters. Furthermore, these experiments enable the possibility for all-optical magnetic resonance experiments on nanoliter sample volumes at high pressures.

36 MATERIALS SCIENCE↗

Design of a Large 5 T Superconducting Magnet for Polarized Target for JLAB Hall B 12 GeV Upgrade Clas12 Detector

Hall B at Jefferson Laboratory (JLAB) will need a 5 T, 78 cm bore polarized target magnet with a field uniformity of {Delta}B/B{sub 0} <; 10{sup -4} in a useful cylinder of the dimensions 0.04 m long x 0.02 m in diameter. The large magnet is designed with a superconducting coil that provides the solenoid with nearly perfect self shielding in order to reduce the fringe field at nearby photo multiplier tubes (PMTs) to less than 3.5 mT. Because the solenoid is also very close to the Clas12 Torus, the nearly perfect shielding provided by the self shielded solenoid greatly reduces force, field, and torque interactions with the six-coil Torus magnet. The solenoid coil consists of 18 coil modules which are made of coils mounted in aluminum plate discs. Each coil module consists of dual double pancake coils with main coils and shield coil partitioned into separate winding cavities in the aluminum plate discs to distribute and reduce radial hoop load and radial coil forces. Each coil module is effectively an enclosed aluminum box and this serves to partition the axial load and thus reduces coil axial forces. Since overall coil forces within each coil module are reduced, this will greatly reduce the number coil training quenches. This is a very important consideration for this solenoid coil because the coil cooling is adiabatic, using in-direct conduction cooling by 4.5 K supercritical helium, which will provide only a relatively small temperature stability margin. Super critical helium is used as per JLAB specification. Detail design of the coil structure, coil assembly, cold mass, and cryogenic control will be presented. The magnet protection system shall be capable of the following features: (1) quench and fault detection, (2) fast discharge of the magnet, (3) limit fault voltages to safe values, (4) monitor interlock signals to prevent unsafe operation, and (5) provide control logic necessary for safe operation of the solenoid. The instrument systems shall be capable of the following features: (1) monitors and display temperatures within the solenoid magnet, (2) measure loads or stress on the magnet suspension, (3) monitor voltages within the solenoid magnet and charging bus, (4) monitor pressures and (5) use data logging system to save all sensor data. These systems will be described and a quench analysis presented.

43 PARTICLE ACCELERATORS↗

Triggering for Magnetic Field Measurements of the LCLS Undulators

A triggering system for magnetic field measurements of the LCLS undulators has been built with a National Instruments PXI-1002 and a Xylinx FPGA board. The system generates single triggers at specified positions, regardless of encoder sensor jitter about a linear scale.

43 PARTICLE ACCELERATORS↗

The Mainz high-precision proton form factor measurement

An extensive measurement of the elastic H(e, e')p reaction in the Q{sup 2}-region from 0.003 to 1 (GeV/c){sup 2} has been performed with the 3-spectrometer-setup of the A1 collaboration at the Mainz Microtron. The dataset consists of about 3000 overlapping cross section measurements with a high level of internal redundancy. The large number of precisely measured cross sections allow for a determination of the electric and magnetic form factors with strict control over statistical and systematic errors, in particular also of the charge and magnetization radii of the proton. Besides the classical Rosenbluth separation, the form factors are separated by direct, global fits of different sufficiently flexible models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezomagnetic switching and complex phase equilibria in uranium dioxide

Abstract Actinide materials exhibit strong spin–lattice coupling and electronic correlations, and are predicted to host new emerging ground states. One example is piezomagnetism and magneto-elastic memory effect in the antiferromagnetic Mott-Hubbard insulator uranium dioxide, though its microscopic nature is under debate. Here, we report X-ray diffraction studies of oriented uranium dioxide crystals under strong pulsed magnetic fields. In the antiferromagnetic state a [888] Bragg diffraction peak follows the bulk magnetostriction that expands under magnetic fields. Upon reversal of the field the expansion turns to contraction, before the [888] peak follows the switching effect and piezomagnetic ‘butterfly’ behaviour, characteristic of two structures connected by time reversal symmetry. An unexpected splitting of the [888] peak is observed, indicating the simultaneous presence of time-reversed domains of the 3-k structure and a complex magnetic-field-induced evolution of the microstructure. These findings open the door for a microscopic understanding of the piezomagnetism and magnetic coupling across strong magneto-elastic interactions.

36 MATERIALS SCIENCE↗

Analysis of synthetic electron cyclotron emission from the high field side of HL-2M tokamak plasmas

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

47 OTHER INSTRUMENTATION↗

RECONSTRUCTING THE SUBSURFACE THREE-DIMENSIONAL MAGNETIC STRUCTURE OF A SOLAR ACTIVE REGION USING SDO/HMI OBSERVATIONS

A solar active region (AR) is a three-dimensional (3D) magnetic structure formed in the convection zone, whose property is fundamentally important for determining the coronal structure and solar activity when emerged. However, our knowledge of the detailed 3D structure prior to its emergence is rather poor, largely limited by the low cadence and sensitivity of previous instruments. Here, using the 45 s high-cadence observations from the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory, we are able for the first time to reconstruct a 3D data cube and infer the detailed subsurface magnetic structure of NOAA AR 11158, and to characterize its magnetic connectivity and topology. This task is accomplished with the aid of the image-stacking method and advanced 3D visualization. We find that the AR consists of two major bipoles or four major polarities. Each polarity in 3D shows interesting tree-like structure, i.e., while the root of the polarity appears as a single tree-trunk-like tube, the top of the polarity has multiple branches consisting of smaller and thinner flux tubes which connect to the branches of the opposite polarity that is similarly fragmented. The roots of the four polarities align well along a straight line, while the top branches are slightly non-coplanar. Our observations suggest that an active region, even appearing highly complicated on the surface, may originate from a simple straight flux tube that undergoes both horizontal and vertical bifurcation processes during its rise through the convection zone.

79 ASTRONOMY AND ASTROPHYSICS↗

The Wide Angle Neutron Diffractometer squared (WAND2) - Possibilities and future

The Wide Angle Neutron Diffractometer (WAND) at the High Flux Isotope Reactor (HFIR), Oak Ridge National Laboratory (ORNL) has been built and continues to be, a joint project between ORNL and the Japan Atomic Energy Agency (JAEA). Equipped with a 1-dimensional position sensitive detector (PSD), the instrument is a multi-purpose instrument for both powder and single crystal diffraction. WAND is currently in the process of a 2-phase upgrade to become a world-class, general purpose instrument. In phase 1, finished in the beginning of 2016, the whole instrument was essentially re-built from scratch, keeping only the front-end and the 1-D PSD. Phase 2 will replace the 1-D PSD with the state-of-the-art BNL120 2-D PSD which comes from the Los Alamos Neutron Science Center. Currently, the detector is integrated off-line into the data acquisition architecture at HFIR and SNS. The new instrument, WAND2, will have event mode capability, improved efficiency, and higher resolution and will be available for general users in the proposal call 2018A. This contribution presents results highlighting the improvements on WAND after phase 1. The upgraded instrument now accommodates the whole suite of available sample environment (50 mK–1500 K, magnetic fields (5 T), high pressures (4 GPa)). Also, the background could be reduced significantly by a factor of 2 through improved shielding, allowing the detection of weak signals. The phase 2 upgrade will require new electronics, data acquisition, and visualization and will result in an altogether new instrument: WAND2.

Frontzek, Matthias D.↗

Robust long-range magnetic correlation across antiphase domain boundaries in Sr 2 CrReO 6

Here, we report a resonant elastic x-ray scattering study of a thin-film sample of Sr 2 CrReO 6 , which has one of the highest ferrimagnetic transition temperatures among ordered double perovskites.We found resonantly enhanced magnetic Bragg peaks at Q = (odd, odd, odd) at both the rhenium L 2 and L 3 edges, which coincide with the structural Bragg peaks of Sr 2 CrReO 6 . By analyzing the widths of these Bragg peaks, we extracted very different structural and magnetic correlation lengths. The former is about 15 nm, while the latter is constrained by the instrumental resolution to be at least 90 nm. We argue that a finite structural correlation length is consistent with the existence of antiphase nanodomains in our sample. On the other hand, a much larger magnetic correlation length indicates that the magnetic correlation extends far beyond the boundaries of individual domains and is consistent with strong antiferromagnetic coupling between different antiphase domains. Last, from the azimuthal dependence of the magnetic intensity, we show that the magnetic moments lie perpendicular to the c axis, which explains the earlier bulk magnetization data.

36 MATERIALS SCIENCE↗

Storm time impulsive enhancements of energetic oxygen due to adiabatic acceleration of preexisting warm oxygen in the inner magnetosphere: Storm Time Impulsive Oxygen Enhancements

We examine enhancements of energetic (>50 keV) oxygen ions observed by the Radiation Belt Storm Probes Ion Composition Experiment (RBSPICE) instrument on board the Van Allen Probes spacecraft in the inner magnetosphere (L ~ 6) at 22–23 h magnetic local time (MLT) during an injection event of the 6 June 2013 storm. Simultaneous observations by two Van Allen Probes spacecraft located close together (~0.5 RE) indicate that particle injections occurred in the premidnight sector (< ~24 h MLT). We also examine the evolution of the proton and oxygen energy spectra at L ~ 6 during the injection event. The spectral slope did not significantly change during the storm. The oxygen phase space density (PSD) was shifted toward higher PSD in a wide range of the first adiabatic invariant. The spectral evolution manifests the characteristics of adiabatic acceleration and density increase of oxygen ions. Warm (0.1–10 keV) oxygen measured by the Helium, Oxygen, Proton, and Electron (HOPE) instrument was enhanced prior to the storm mostly in magnetic field-aligned directions. Finally, the most reasonable scenario of this event is that warm oxygen ions that preexisted in the inner magnetosphere were picked up and adiabatically transported and accelerated by spatially localized, temporarily impulsive electric fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft X-ray measurements of transport and MHD activity in the core and edge NSTX plasma (Final Technical Report)

A comprehensive suite of innovative diagnostic instrumentation and techniques has been developed by the Johns Hopkins collaboration for measurements of transport and MHD activity in the core and edge of the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory (PPPL). These include ultrafast multi-energy poloidal soft X-ray arrays, high spatial resolution multi-energy tangential soft X-ray arrays, high spectral resolution transmission grating imaging VUV spectrometers and ultrafast bolometric arrays, which measure over a broad range of spatial, spectral, and temporal scales the emission from ohmic, RF, and beam driven NSTX plasmas. The instrumentation was designed to fulfill the specific measurement needs of the Spherical Torus (ST) magnetic fusion concept and is accompanied by a comprehensive set of numerical tools for data analysis and modeling, aimed at determining as many as possible plasma parameters and at extracting as much as possible physics information from NSTX experiments. The Johns Hopkins diagnostics have been and continue to be instrumental for essentially all the NSTX experiments. In addition, our own research and experiments using these diagnostics has led over the years to fundamental conclusions for the ST fusion physics, such as the establishment of near neoclassical impurity transport in the NSTX core and edge plasma, and the critical role of the Global Alfven Eigenmode (GAE) MHD activity for the ST core electron thermal transport. The Johns Hopkins Diagnostics continue to be operational on the upgraded NSTX-U and will provide key plasma information in its upcoming high field, current and power experimental campaigns. The present report summarizes the main technical characteristics and measurement capabilities of the diagnostic instrumentation and methods developed within our research and describes a key physics result achieved during this research. Success in our research was made possible also by the excellent support and cooperation of the NSTX research team and of PPPL researchers, who are warmly acknowledged here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise mitigation methods for ion detectors operating with a direct view of high temperature plasmas

In this work, we have developed an ion current measurement instrument with a direct view of a plasma that reduces the particle and radiation-induced noise current it detects by over three orders of magnitude, from tens of microamps to tens of nanoamps. This is accomplished using electric fields, magnetic fields, and physical shielding that limit the flux of particles and radiation into the instrument and suppress the secondary electrons produced within it by particle and radiation impact. Operation of this detector in various configurations, without an ion beam, has allowed identification of the sources of noise current. In our experimental setup, the largest noise contributors were found to be plasma ions and photoelectric emission due to UV radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Simulation and Characterization of the MINER{nu}A Dipole Magnets

The MINER{nu}A (Main INjector ExpeRiment for {nu} A) experiment (http://minerva.fnal.gov/) is a neutrino scattering experiment which uses the NuMI beamline at Fermilab. It seeks to measure low energy neutrino interactions both to support neutrino oscillation experiments and to study the strong dynamics of the nucleon and nucleus that affect these interactions. For energy calibration of the main detector, a tertiary test beam line was designed and commissioned. This test beam consisted of target, collimator, two TOF stations and four wire chamber stations. Two dipole trim magnets were used to form a spectrometer. Here we present the simulation and characterization of these dipole magnets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the charge-state separation at ITEP experimental facility for material science based on a Bernas ion source

The experiment automation system is supposed to be developed for experimental facility for material science at ITEP, based on a Bernas ion source. The program CAMFT is assumed to be involved into the program of the experiment automation. CAMFT is developed to simulate the intense charged particle bunch motion in the external magnetic fields with arbitrary geometry by means of the accurate solution of the particle motion equation. Program allows the consideration of the bunch intensity up to 10{sup 10} ppb. Preliminary calculations are performed at ITEP supercomputer. The results of the simulation of the beam pre-acceleration and following turn in magnetic field are presented for different initial conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗