Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Working charts for the stress analysis of elliptic rings

This report presents charts which reduce the stress analysis of circular and elliptic rings of uniform cross section subjected to balanced systems of concentrated loads from a statically indeterminate problem to a statically determinate one. To demonstrate the use of the charts in the stress analysis of elliptic rings, an illustrative problem is included.

Burke, Walter F↗

Performance and Flowfield Measurements on a 10-inch Ducted Rotor VTOL UAV

A ducted fan VTOL UAV with a 10-inch diameter rotor was tested in the US Army 7-by 10-Foot Wind Tunnel. The test conditions covered a range of angle of attack from 0 to 110 degrees to the freestream. The tunnel velocity was varied from 0 (simulating a hover condition) to 128 ft/sec in propeller mode. A six-component internal balance measured the aerodynamic loads for a range of model configurations. including the isolated rotor, the isolated duct, and the full configuration of the duct and rotor. For some conditions, hotwire velocity surveys were conducted along the inner and outer surface of the duct and across the downstream wake. In addition, fluorescent oil flow visualization allowed the flow separation patterns inside and outside of the duct to be mapped for a few test conditions. Two different duct shapes were tested to determine the performance effects of leading edge radius. For each duct, a range of rotor tip gap from 1%R to 4.5%R was tested to determine the performance penalty in hover and axial flight. Measured results are presented in terms of hover performance, hover performance in a crosswind, and high angle of attack performance in propeller mode. In each case, the effects of both tip gap and duct leading edge radius are illustrated using measurements. Some of the hover performance issues were also studied using a simple analytical method, and the results agreed with the measurements.

Martin, Preston↗

Blended-Wing-Body (BWB) Fuselage Structural Design for Weight Reduction

Structural analysis and design of efficient pressurized fuselage configurations for the advanced Blended-Wing-Body (BWB) flight vehicle is a challenging problem. Unlike a conventional cylindrical pressurized fuselage, stress level in a box type BWB fuselage is an order of magnitude higher, because internal pressure primarily results in bending stress instead of skin-membrane stress. In addition, resulting deformation of aerodynamic surface could significantly affect performance advantages provided by lifting body. The pressurized composite conformal multi-lobe tanks of X-33 type space vehicle also suffered from similar problem. In the earlier BWB design studies, Vaulted Ribbed Shell (VLRS), Flat Ribbed Shell (FRS); Vaulted shell Honeycomb Core (VLHC) and Flat sandwich shell Honeycomb Core (FLHC) concepts were studied. The flat and vaulted ribbed shell concepts were found most efficient. In a recent study, a set of composite sandwich panel and cross-ribbed panel were analyzed. Optimal values of rib and skin thickness, rib spacing, and panel depth were obtained for minimal weight under stress and buckling constraints. In addition, a set of efficient multi-bubble fuselage (MBF) configuration concept was developed. The special geometric configuration of this concept allows for balancing internal cabin pressure load efficiently, through membrane stress in inner-stiffened shell and inter-cabin walls, while the outer-ribbed shell prevents buckling due to external resultant compressive loads. The initial results from these approximate finite element analyses indicate progressively lower maximum stresses and deflections compared to the earlier study. However, a relative comparison of the FEM weight per unit floor area of the segment unit indicates that the unit weights are still relatively higher that the conventional B777 type cylindrical or A380 type elliptic fuselage design. Due to the manufacturing concern associated with multi-bubble fuselage, a Y braced box-type fuselage alternative with special resin-film injected (RFI) stitched carbon composite with foam-core was designed by Boeing under a NASA research contract for the 480 passenger version. It is shown that this configuration can be improved to a modified multi-bubble fuselage which has better stress distribution, for same material and dimension.

Mukhopadhyay, V.↗

Aeroservoelastic Testing of a Sidewall Mounted Free Flying Wind-Tunnel Model

A team comprised of the Air Force Research Laboratory (AFRL), Northrop Grumman, Lockheed Martin, and the NASA Langley Research Center conducted three j wind-tunnel tests in the Transonic Dynamics Tunnel to demonstrate active control technologies relevant to large, exible vehicles. In the rst of these three tests, a semispan, aeroelastically scaled, wind-tunnel model of a ying wing SensorCraft vehi- cle was mounted to a force balance to demonstrate gust load alleviation. In the second and third tests, the same wing was mated to a new, multi-degree-of-freedom, sidewall mount. This mount allowed the half-span model to translate vertically and pitch at the wing root, allowing better simulation of the full span vehicle's rigid-body modes. Gust Load Alleviation (GLA) and Body Freedom Flutter (BFF) suppression were successfully demonstrated. The rigid body degrees-of-freedom required that the model be own in the wind tunnel using an active control system. This risky mode of testing necessitated that a model arrestment system be integrated into the new mount. The safe and successful completion of these free-flying tests required the development and integration of custom hardware and software. This paper describes the many systems, software, and procedures that were developed as part of this effort.

Scott, Robert C.↗

Use of Residential Smart Appliances for Peak Load Shifting & Spinning Reserves: Cost Benefit Analysis

Abstract In this paper, we present the results of an analytical cost-benefit study of residential smart appliances in support of a joint stakeholder petition to the EPA and DOE to provide a 5% credit to meet ENERGY STAR eligibility criteria for products that meet the definition of a smart appliance. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the challenges associated with increased electricity demand, and increased penetration of renewable sources of power. Our analytical model utilizes current annual appliance electricity consumption data, and estimates what the wholesale grid operating cost savings would be if some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads serve power system balancing needs such as spinning reserves that would otherwise have to be provided by generators. Historical wholesale market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States are used to estimate savings. The savings are then compared with the five percent credit, to determine if the savings in grid operating costs (benefits) are at least as high as the credit (cost) if not higher.

Sastry, Chellury↗

Application analysis of ground source heat pumps in building space conditioning

The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning for Fairness-Aware Load Shedding: A Real-Time Solution via Identifying Binding Constraints: Preprint

Timely and effective load shedding in power systems is critical for maintaining supply-demand balance and preventing cascading blackouts. To eliminate load shedding bias against specific regions in the system, optimization-based methods are uniquely positioned to help balance between economic and fairness considerations. However, the resulting optimization problem involves complex constraints, which can be time-consuming to solve and thus cannot meet the real-time requirements of load shedding. To tackle this challenge, in this paper we present an efficient machine learning algorithm to enable millisecond-level computation for the optimization-based load shedding problem. Numerical studies on both a 3-bus toy example and a realistic RTS-GMLC system have demonstrated the validity and efficiency of the proposed algorithm for delivering fairness-aware and real-time load shedding decisions.

97 MATHEMATICS AND COMPUTING↗

An investigation of tip planform influence on the aerodynamic load characteristics of semispan, upswept wing and wing-tip

A semi-span wing, equipped with an interchangeable tip, which was varied in planform and size was examined. Total wing aerodynamic loading was obtained from the wind tunnel scale system. The wing tip was mounted on a separate six-component strain gauge balance, which provided the aerodynamic loads on the tip. The tests were accomplished in the NASA Ames 7X10-Foot Wind Tunnel at a Mach number of 0.178. The aerodynamic load characteristics of the wing and of the tip were presented with the tip at several incidence angles relative to the wing inboard section.

Vanaken, Johannes M.↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

Distributed Load Shedding over Directed Communication Networks with Time Delays

When generation is insufficient to support all loads under emergencies, effective and efficient load shedding needs to be deployed in order to maintain the supply-demand balance. This paper presents a distributed load shedding algorithm, which makes efficient decision based on the discovered global information. In the global information discovery process, each load only communicates with its neighboring load via directed communication links possibly with arbitrarily large but bounded time varying communication delays. We propose a novel distributed information discovery algorithm based on ratio consensus. Simulation results are used to validate the proposed method.

Yang, Tao↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single Vector Calibration System for Multi-Axis Load Cells and Method for Calibrating a Multi-Axis Load Cell

A single vector calibration system is provided which facilitates the calibration of multi-axis load cells, including wind tunnel force balances. The single vector system provides the capability to calibrate a multi-axis load cell using a single directional load, for example loading solely in the gravitational direction. The system manipulates the load cell in three-dimensional space, while keeping the uni-directional calibration load aligned. The use of a single vector calibration load reduces the set-up time for the multi-axis load combinations needed to generate a complete calibration mathematical model. The system also reduces load application inaccuracies caused by the conventional requirement to generate multiple force vectors. The simplicity of the system reduces calibration time and cost, while simultaneously increasing calibration accuracy.

Parker, Peter A.↗

Miniature Remote Deadweight Calibrator

Miniature, computer-controlled deadweight calibrator developed to calibrate remotely force transducer located in cryogenic chamber. Used with microcomputer, calibration system automatically applies deadweight loads to skin-friction balance, records and reduces data, and prints out results. Actuator controller and interlocking-weight system key elements in precise, automatic transducer calibrator. Designed for full-scale load of 1,000 mg. Concept extended to accommodate other full-scale load ranges.

Supplee, Frank H., Jr.↗

Dynamic Calibration of the NASA Ames Rotor Test Apparatus Steady/Dynamic Rotor Balance

The NASA Ames Rotor Test Apparatus was modified to include a Steady/Dynamic Rotor Balance. The dynamic calibration procedures and configurations are discussed. Random excitation was applied at the rotor hub, and vibratory force and moment responses were measured on the steady/dynamic rotor balance. Transfer functions were computed using the load cell data and the vibratory force and moment responses from the rotor balance. Calibration results showing the influence of frequency bandwidth, hub mass, rotor RPM, thrust preload, and dynamic loads through the stationary push rods are presented and discussed.

Peterson, Randall L.↗

Three-Component Force Measurements on a Scramjet in a Reflected-Shock Tunnel

A three-component stress-wave force-balance for a large scramjet has been designed, calibrated and tested in the HYPULSE reflected shock tunnel at GASL Inc., New York. The scramjet model is over 3-foot long and weighs in excess of 90 Ibm. The stress-wave force-balance is comprised of three stress bars which are attached to the model. Calibration results indicate that the force balance responds well within about 1 ms and that the sensitivity of the balance to the distribution of load is not large. Results with and without fuel injection were obtained in the tunnel operated for Mach 7 and Mach 10 flight simulation. These tests showed the force-balance can resolve axial force increments due to combustion of about 40 lb in the presence of model lift forces of 500-700 lb.

Tsai, C.-Y.↗

Effect of occupant behavior and air-conditioner controls on humidity in typical and high-efficiency homes

Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity, and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗