Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

Paradigmatic error calculations for adaptive finite element approximations of convection dominated flows

New error estimation techniques are described for two-dimensional convection-dominated flows. Examples of applications to linear convection problems are given. The methods are based on discontinuous finite-element techniques. Results show that conventional interpolation methods may lead to gross underestimates of actual error and be inadequate for use in adaptive methods.

Oden, J. T.↗

Using Solar Radiation Pressure to Control L2 Orbits

The main perturbations at the Sun-Earth Lagrange points L1 and L2 are from solar radiation pressure (SRP), the Moon and the planets. Traditional approaches to trajectory design for Lagrange-point orbits use maneuvers every few months to correct for these perturbations. The gravitational effects of the Moon and the planets are small and periodic. However, they cannot be neglected because small perturbations in the direction of the unstable eigenvector are enough to cause exponential growth within a few months. The main effect of a constant SRP is to shift the center of the orbit by a small distance. For spacecraft with large sun-shields like the Microwave Anisotropy Probe (MAP) and the Next Generation Space Telescope (NGST), the SRP effect is larger than all other perturbations and depends mostly on spacecraft attitude. Small variations in the spacecraft attitude are large enough to excite or control the exponential eigenvector. A closed-loop linear controller based on the SRP variations would eliminate one of the largest errors to the orbit and provide a continuous acceleration for use in controlling other disturbances. It is possible to design reference trajectories that account for the periodic lunar and planetary perturbations and still satisfy mission requirements. When such trajectories are used the acceleration required to control the unstable eigenvector is well within the capabilities of a continuous linear controller. Initial estimates show that by using attitude control it should be possible to minimize and even eliminate thruster maneuvers for station keeping.

Tene, Noam↗

Evaluation of Voronoi Meshes for Large Eddy Simulations of High Lift Aerodynamics

Numerical sensitivity to 3 different Voronoi seeding methods is investigated for Large Eddy Simulations (LES). A second order accurate, non-dissipative finite volume discretization is used to systematically investigate the effects of different polyhedral Voronoi mesh types using a sequence of three canonical problems with increasing complexity. First, inviscid isentropic vortex propagation is studied to demonstrate the substantial reduction of errors for rhombic dodecahedron and truncated octahedral cell types over Cartesian hexagonal cells of identical spacing. Furthermore, the reduction of errors induced at cell-size transitions (grid-coarsening interfaces) due to Lloyd smoothing iterations is quantified. It is shown that by utilizing an appropriate viscous flux discretization, a constant coefficient subgrid scale model is sufficient for non-linear stability at the 2:1 cell-size transitions on polyhedral grids, although some further error reduction does occur when smoothing is utilized. Next, forced homogeneous isotropic turbulence at an asymptotically large Reynolds number is studied to demonstrate the non-dissipative character of the inviscid flux discretization, and the non-linear robustness and accuracy offered by the viscous flux discretization using a subgrid scale model for all three Voronoi grid types. Finally,Wall-Modeled Large Eddy Simulations (WMLES) are performed to study the high-lift aerodynamics on the McDonnell Douglas 30P30N multi-element airfoil at two distinct grid levels and for two distinct Voronoi cell types. The formulation is shown to predict the aerodynamic loading with high accuracy at all angles of attack when sufficient resolution is reached, and the hexagonal prism grid topology, while computationally more expensive, has higher effective resolution compared to the Cartesian grid topology with the same spacing.

TTT↗

Evaluation of Voronoi Meshes for Large Eddy Simulations of High Lift Aerodynamics

Numerical sensitivity to 3 different Voronoi seeding methods is investigated for Large Eddy Simulations (LES). A second order accurate, non-dissipative finite volume discretization is used to systematically investigate the effects of different polyhedral Voronoi mesh types using a sequence of three canonical problems with increasing complexity. First, inviscid isentropic vortex propagation is studied to demonstrate the substantial reduction of errors for rhombic dodecahedron and truncated octahedral cell types over Cartesian hexagonal cells of identical spacing. Furthermore, the reduction of errors induced at cell-size transitions (grid-coarsening interfaces) due to Lloyd smoothing iterations is quantified. It is shown that by utilizing an appropriate viscous flux discretization, a constant coefficient subgrid scale model is sufficient for non-linear stability at the 2:1 cell-size transitions on polyhedral grids, although some further error reduction does occur when smoothing is utilized. Next, forced homogeneous isotropic turbulence at an asymptotically large Reynolds number is studied to demonstrate the non-dissipative character of the inviscid flux discretization, and the non-linear robustness and accuracy offered by the viscous flux discretization using a subgrid scale model for all three Voronoi grid types. Finally, Wall-Modeled Large Eddy Simulations (WMLES) are performed to study the high-lift aerodynamics on the McDonnell Douglas 30P30N multi-element airfoil at two distinct grid levels and for two distinct Voronoi cell types. The formulation is shown to predict the aerodynamic loading with high accuracy at all angles of attack when sufficient resolution is reached, and the hexagonal prism grid topology, while computationally more expensive, has higher effective resolution compared to the Cartesian grid topology with the same spacing.

TTT↗

Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed. To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23-62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI {>=}25 to <30); 26.7% (n = 8) were mildly obese (BMI {>=}30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI {>=} 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PolyFit: A C++ code for Polynomial Curve Fit with Calculation of Error Bars

In radiobiology, many dose-response results are modeled using the so-called linear-quadratic (LQ)model, which means that results are modeled as a function of dose Das 𝑅(𝐷)=𝛽0+𝛽1𝐷+𝛽2𝐷2. The coefficients 𝛽0, 𝛽1and 𝛽2are obtained from fitting a series of data points (𝑥𝑖, 𝑦𝑖), which is usually done using a least-square method. The LQ and more generally the polynomial fit capability is implemented in many software that analyzes data. However, there are some instances where the fitting needs to be done programmatically. Furthermore, depending on the software used, some features may not be implemented. In this mini-review, I discuss the basis of polynomial fitting, including the calculation of errors on the coefficients and results, use of weighting and fixing the intercept value (the coefficient 𝛽0). A simple C++ code to perform the polynomial curve fitting is also provided. This code should be useful not only in radiobiology but in other fields of science as well.

Ianik Plante↗

Fitting of satellite and in-situ ocean surface temperatures Results for polymode during the winter of 1977-1978

For the period considered, December 1977 through February 1978, bivariate Gaussian discriminant function cloud identification revealed that more than 93 percent of the 8-km resolution GOES infrared pixels were cloud contaminated. Cloud-free in-situ calibration points were distributed in nonrandom groups; this resulted in systematic errors when using least squares techniques. Surfaces and regression lines were least squares fitted between satellite and in-situ data; use was also made of differences and ratios. The best results were achieved with a regression in the form of the infrared radiative transfer equation; but this was no better than + or - 0.9 K. Because of extensive cloudiness, the linear regressions were seldom useful, and temperature ratios with + or - 1.3 K experimental errors best represent the applicability of GEOS data to sea surface temperatures.

Maul, G. A.↗

PolyFit: A C++ code for Polynomial Curve Fit with Calculation of Error Bars

In radiobiology, many dose-response results are modeled using the so-called linear-quadratic(LQ)model, which means that results are modeled as a function of dose Das 𝑅(𝐷)=𝛽0+𝛽1𝐷+𝛽2𝐷2. The coefficients 𝛽0, 𝛽1and 𝛽2are obtained from fitting a series of data points (𝑥𝑖,𝑦𝑖), which is usually done using a least-square method. The LQ and more generally the polynomial fit capability is implemented in many software that analyzes data. However, it is often convenient to do the fitting programmatically, especially when a large number of datasets should be analyzed. Furthermore, depending on the software used, some features may not be implemented. In this mini-review, I discuss the basis of polynomial fitting, including the calculation of errors on the coefficients and results, use of weighting and fixing the intercept value (the coefficient 𝛽0). A simple C++ code to perform the polynomial curve fitting is also provided. This code should be useful not only in radiobiology but in other fields of science as well.

Ianik Plante↗

Optimal Prediction of Clocks from Finite Data

This talk is about optimal linear prediction of processes with stationary dth increments, which serve as a class of models for random clock disturbances. The predictor is obtained by orthogonal projection on the affine space of estimators whose errors are invariant to additive polynomials of degree < d. The projection conditions give a system of linear equations thatcan be solved straightforwardly for the regression coefficients. If the data are equally spaced, then the predictor can be obtained by an extension of Levinson's algorithm.

stationary increments↗

Regression Analysis of Top of Descent Location for Idle-thrust Descents

In this paper, multiple regression analysis is used to model the top of descent (TOD) location of user-preferred descent trajectories computed by the flight management system (FMS) on over 1000 commercial flights into Melbourne, Australia. The independent variables cruise altitude, final altitude, cruise Mach, descent speed, wind, and engine type were also recorded or computed post-operations. Both first-order and second-order models are considered, where cross-validation, hypothesis testing, and additional analysis are used to compare models. This identifies the models that should give the smallest errors if used to predict TOD location for new data in the future. A model that is linear in TOD altitude, final altitude, descent speed, and wind gives an estimated standard deviation of 3.9 nmi for TOD location given the trajec- tory parameters, which means about 80% of predictions would have error less than 5 nmi in absolute value. This accuracy is better than demonstrated by other ground automation predictions using kinetic models. Furthermore, this approach would enable online learning of the model. Additional data or further knowl- edge of algorithms is necessary to conclude definitively that no second-order terms are appropriate. Possible applications of the linear model are described, including enabling arriving aircraft to fly optimized descents computed by the FMS even in congested airspace. In particular, a model for TOD location that is linear in the independent variables would enable decision support tool human-machine interfaces for which a kinetic approach would be computationally too slow.

trajectory prediction↗

A high order accurate finite element algorithm for high Reynolds number flow prediction

A Galerkin-weighted residuals formulation is employed to establish an implicit finite element solution algorithm for generally nonlinear initial-boundary value problems. Solution accuracy, and convergence rate with discretization refinement, are quantized in several error norms, by a systematic study of numerical solutions to several nonlinear parabolic and a hyperbolic partial differential equation characteristic of the equations governing fluid flows. Solutions are generated using selective linear, quadratic and cubic basis functions. Richardson extrapolation is employed to generate a higher-order accurate solution to facilitate isolation of truncation error in all norms. Extension of the mathematical theory underlying accuracy and convergence concepts for linear elliptic equations is predicted for equations characteristic of laminar and turbulent fluid flows at nonmodest Reynolds number. The nondiagonal initial-value matrix structure introduced by the finite element theory is determined intrinsic to improved solution accuracy and convergence. A factored Jacobian iteration algorithm is derived and evaluated to yield a consequential reduction in both computer storage and execution CPU requirements while retaining solution accuracy.

Baker, A. J.↗

Microgrid Optimal Scheduling With Chance-Constrained Islanding Capability

To facilitate the integration of variable renewable generation and improve the resilience of electricity sup-ply in a microgrid, this paper proposes an optimal scheduling strategy for microgrid operation considering constraints of islanding capability. A new concept, probability of successful islanding (PSI), indicating the probability that a microgrid maintains enough spinning reserve (both up and down) to meet local demand and accommodate local renewable generation after instantaneously islanding from the main grid, is developed. The PSI is formulated as mixed-integer linear program using multi-interval approximation taking into account the probability distributions of forecast errors of wind, PV and load. With the goal of minimizing the total operating cost while preserving user specified PSI, a chance-constrained optimization problem is formulated for the optimal scheduling of mirogrids and solved by mixed integer linear programming (MILP). Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, a micro-turbine, a diesel generator and a battery demonstrate the effectiveness of the proposed scheduling strategy. Lastly, we verify the relationship between PSI and various factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A function space approach to state and model error estimation for elliptic systems

An approach is advanced for the concurrent estimation of the state and of the model errors of a system described by elliptic equations. The estimates are obtained by a deterministic least-squares approach that seeks to minimize a quadratic functional of the model errors, or equivalently, to find the vector of smallest norm subject to linear constraints in a suitably defined function space. The minimum norm solution can be obtained by solving either a Fredholm integral equation of the second kind for the case with continuously distributed data or a related matrix equation for the problem with discretely located measurements. Solution of either one of these equations is obtained in a batch-processing mode in which all of the data is processed simultaneously or, in certain restricted geometries, in a spatially scanning mode in which the data is processed recursively. After the methods for computation of the optimal estimates are developed, an analysis of the second-order statistics of the estimates and of the corresponding estimation error is conducted. Based on this analysis, explicit expressions for the mean-square estimation error associated with both the state and model error estimates are then developed.

Rodriguez, G.↗

A function space approach to state and model error estimation for elliptic systems

An approach is advanced for the concurrent estimation of the state and of the model errors of a system described by elliptic equations. The estimates are obtained by a deterministic least-squares approach that seeks to minimize a quadratic functional of the model errors, or equivalently, to find the vector of smallest norm subject to linear constraints in a suitably defined function space. The minimum norm solution can be obtained by solving either a Fredholm integral equation of the second kind for the case with continuously distributed data or a related matrix equation for the problem with discretely located measurements. Solution of either one of these equations is obtained in a batch-processing mode in which all of the data is processed simultaneously or, in certain restricted geometries, in a spatially scanning mode in which the data is processed recursively. After the methods for computation of the optimal esimates are developed, an analysis of the second-order statistics of the estimates and of the corresponding estimation error is conducted. Based on this analysis, explicit expressions for the mean-square estimation error associated with both the state and model error estimates are then developed. While this paper focuses on theoretical developments, applications arising in the area of large structure static shape determination are contained in a closely related paper (Rodriguez and Scheid, 1982).

Rodriguez, G.↗

Using an external surrogate for predictor model training in real-time motion management of lung tumors

Purpose: Precise prediction of respiratory motion is a prerequisite for real-time motion compensation techniques such as beam, dynamic couch, or dynamic multileaf collimator tracking. Collection of tumor motion data to train the prediction model is required for most algorithms. To avoid exposure of patients to additional dose from imaging during this procedure, the feasibility of training a linear respiratory motion prediction model with an external surrogate signal is investigated and its performance benchmarked against training the model with tumor positions directly. Methods: The authors implement a lung tumor motion prediction algorithm based on linear ridge regression that is suitable to overcome system latencies up to about 300 ms. Its performance is investigated on a data set of 91 patient breathing trajectories recorded from fiducial marker tracking during radiotherapy delivery to the lung of ten patients. The expected 3D geometric error is quantified as a function of predictor lookahead time, signal sampling frequency and history vector length. Additionally, adaptive model retraining is evaluated, i.e., repeatedly updating the prediction model after initial training. Training length for this is gradually increased with incoming (internal) data availability. To assess practical feasibility model calculation times as well as various minimum data lengths for retraining are evaluated. Relative performance of model training with external surrogate motion data versus tumor motion data is evaluated. However, an internal–external motion correlation model is not utilized, i.e., prediction is solely driven by internal motion in both cases. Results: Similar prediction performance was achieved for training the model with external surrogate data versus internal (tumor motion) data. Adaptive model retraining can substantially boost performance in the case of external surrogate training while it has little impact for training with internal motion data. A minimum adaptive retraining data length of 8 s and history vector length of 3 s achieve maximal performance. Sampling frequency appears to have little impact on performance confirming previously published work. By using the linear predictor, a relative geometric 3D error reduction of about 50% was achieved (using adaptive retraining, a history vector length of 3 s and with results averaged over all investigated lookahead times and signal sampling frequencies). The absolute mean error could be reduced from (2.0 ± 1.6) mm when using no prediction at all to (0.9 ± 0.8) mm and (1.0 ± 0.9) mm when using the predictor trained with internal tumor motion training data and external surrogate motion training data, respectively (for a typical lookahead time of 250 ms and sampling frequency of 15 Hz). Conclusions: A linear prediction model can reduce latency induced tracking errors by an average of about 50% in real-time image guided radiotherapy systems with system latencies of up to 300 ms. Training a linear model for lung tumor motion prediction with an external surrogate signal alone is feasible and results in similar performance as training with (internal) tumor motion. Particularly for scenarios where motion data are extracted from fluoroscopic imaging with ionizing radiation, this may alleviate the need for additional imaging dose during the collection of model training data.

60 APPLIED LIFE SCIENCES↗

POWER OF OBSERVATIONAL HUBBLE PARAMETER DATA: A FIGURE OF MERIT EXPLORATION

We use simulated Hubble parameter data in the redshift range 0 {<=} z {<=} 2 to explore the role and power of observational H(z) data in constraining cosmological parameters of the {Lambda}CDM model. The error model of the simulated data is empirically constructed from available measurements and scales linearly as z increases. By comparing the median figures of merit calculated from simulated data sets with that of current Type Ia supernova (SNIa) data, we find that as many as 64 further independent measurements of H(z) are needed to match the parameter constraining power of SNIa. If the error of H(z) could be lowered to 3%, the same number of future measurements would be needed, but then the redshift coverage would only be required to reach z = 1. We also show that accurate measurements of the Hubble constant H{sub 0} can be used as priors to increase the H(z) data's figure of merit.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of exposure estimation errors on estimated exposure-response relations for PM2.5

Highlights: • Recent literature has identified associations between concentrations of fine particulate matter (PM2.5) in ambient air and adverse health effects at estimated exposure concentrations below current air ambient quality standards. • The models and analyses used do not usually quantify uncertainty about exposure estimates. • Realistic errors in exposure estimates can be estimated from available air quality monitoring stations by predicting concentrations at each station from concentrations at neighboring stations. • Exposure estimation errors are large enough to obscure low-dose nonlinearities or thresholds in the true concentration-response (C-R) function, artificially making them appear to be linear at low doses. • Better estimates of C-R functions will require modeling exposure distributions and estimation errors, rather than just estimating average exposure concentrations. Associations between fine particulate matter (PM2.5) exposure concentrations and a wide variety of undesirable outcomes, from autism and auto theft to elderly mortality, suicide, and violent crime, have been widely reported. Influential articles have argued that reducing National Ambient Air Quality Standards for PM2.5 is desirable to reduce these outcomes. Yet, other studies have found that reducing black smoke and other particulate matter by as much as 70% and dozens of micrograms per cubic meter has not detectably affected all-cause mortality rates even after decades, despite strong, statistically significant positive exposure concentration-response (C-R) associations between them. This paper examines whether this disconnect between association and causation might be explained in part by ignored estimation errors in estimated exposure concentrations. We use EPA air quality monitor data from the Los Angeles area of California to examine the shapes of estimated C-R functions for PM2.5 when the true C-R functions are assumed to be step functions with well-defined response thresholds. The estimated C-R functions mistakenly show risk as smoothly increasing with concentrations even well below the response thresholds, thus incorrectly predicting substantial risk reductions from reductions in concentrations that do not affect health risks. We conclude that ignored estimation errors obscure the shapes of true C-R functions, including possible thresholds, possibly leading to unrealistic predictions of the changes in risk caused by changing exposures. Instead of estimating improvements in public health per unit reduction (e.g., per 10 µg/m{sup 3} decrease) in average PM2.5 concentrations, it may be essential to consider how interventions change the distributions of exposure concentrations.

54 ENVIRONMENTAL SCIENCES↗