Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOOP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The January 2015 Repressurization of ISS ATCS Loop B - Analysis Limitations and Concerns

In January 2013 a false ammonia leak alarm resulted in the shutdown and partial depressurization of one of the two International Space Station (ISS) External Active Thermal Control System (EATCS) loops. The depressurization resulted in a vapor bubble of 18 liters in warm parts of the stagnant loop. To repressurize the loop and regain system operation, liquid would have to be moved from the Ammonia Tank Assembly (ATA) into the loop. This resulted in the possibility of moving cold (as low as ‐30 C) ammonia into the water‐filled Internal Active Thermal Control System (IATCS) interface heat exchangers. Before moving forward, the freezing potential of the repressurization was evaluated through analysis - using both a Thermal Desktop SINDA/FLUINT model and hand calculations. The models yielded very different results, but both models indicated that heat exchanger freezing was not an issue. Therefore, the repressurization proceeded. The presentation describes the physical situation of the EATCS prior to repressurization and discusses the potential limits and pitfalls of the repressurization. The pre‐repressurization analytical models and their results are discussed. The successful repressurization is describled and the results of a post‐event model assessment is detailed.

Ungar, Eugene↗

A Methodology to Assess the Capability of Engine Designs to Meet Closed-loop Performance and Operability Requirements

Designing a closed-loop controller for an engine requires balancing trade-offs between performance and operability of the system. One such trade-off is the relationship between the 95% response time and minimum high-pressure compressor (HPC) surge margin (SM) attained during acceleration from idle to takeoff power. Assuming a controller has been designed to meet some specification on response time and minimum HPC SM for a mid-life (nominal) engine, there is no guarantee that these limits will not be violated as the engine ages, particularly as it reaches the end of its life. A characterization for the uncertainty in this closed-loop system due to aging is proposed that defines elliptical boundaries to estimate worst-case performance levels for a given control design point. The results of this characterization can be used to identify limiting design points that bound the possible con- troller designs yielding transient results that do not exceed specified limits in response time or minimum HPC SM. This characterization involves performing Monte Carlo simulation of the closed-loop system with controller constructed for a set of trial design points and developing curve fits to describe the size and orientation of each ellipse; a binary search procedure is then employed that uses these fits to identify the limiting design point. The method is demonstrated through application to a generic turbofan engine model in closed- loop with a simplified controller; it is found that the limit for which each controller was designed was exceeded by less than 4.76%. Extension of the characterization to another trade-off, that between the maximum high-pressure turbine (HPT) entrance temperature and minimum HPC SM, showed even better results: the maximum HPT temperature was estimated within 0.76%. Because of the accuracy in this estimation, this suggests another limit that may be taken into consideration during design and analysis. It also demonstrates the extension of the characterization to other attributes that contribute to the performance or operability of the engine. Metrics are proposed that, together, provide information on the shape of the trade-off between response time and minimum HPC SM, and how much each varies throughout the life cycle, at the limiting design points. These metrics also facilitate comparison of the expected transient behavior for multiple engine models.

engine control↗

A Methodology to Assess the Capability of Engine Designs to Meet Closed-Loop Performance and Operability Requirements

Designing a closed-loop controller for an engine requires balancing trade-offs between performance and operability of the system. One such trade-off is the relationship between the 95 percent response time and minimum high-pressure compressor (HPC) surge margin (SM) attained during acceleration from idle to takeoff power. Assuming a controller has been designed to meet some specification on response time and minimum HPC SM for a mid-life (nominal) engine, there is no guarantee that these limits will not be violated as the engine ages, particularly as it reaches the end of its life. A characterization for the uncertainty in this closed-loop system due to aging is proposed that defines elliptical boundaries to estimate worst-case performance levels for a given control design point. The results of this characterization can be used to identify limiting design points that bound the possible controller designs yielding transient results that do not exceed specified limits in response time or minimum HPC SM. This characterization involves performing Monte Carlo simulation of the closed-loop system with controller constructed for a set of trial design points and developing curve fits to describe the size and orientation of each ellipse; a binary search procedure is then employed that uses these fits to identify the limiting design point. The method is demonstrated through application to a generic turbofan engine model in closed-loop with a simplified controller; it is found that the limit for which each controller was designed was exceeded by less than 4.76 percent. Extension of the characterization to another trade-off, that between the maximum high-pressure turbine (HPT) entrance temperature and minimum HPC SM, showed even better results: the maximum HPT temperature was estimated within 0.76 percent. Because of the accuracy in this estimation, this suggests another limit that may be taken into consideration during design and analysis. It also demonstrates the extension of the characterization to other attributes that contribute to the performance or operability of the engine. Metrics are proposed that, together, provide information on the shape of the trade-off between response time and minimum HPC SM, and how much each varies throughout the life cycle, at the limiting design points. These metrics also facilitate comparison of the expected transient behavior for multiple engine models.

systems analysis↗

And the Human Saves the Day or Maybe They Ruin It, The Importance of Humans in the Loop

Flying a mission in space requires a massive commitment of resources, and without the talent and commitment of the people involved in this effort we would never leave the atmosphere of Earth as safely as we have. When we use the phrase "humans in the loop", it could apply to almost any endeavor since everything starts with humans developing a concept, completing the design process, building or implementing a product and using the product to achieve a goal or purpose. Narrowing the focus to spaceflight, there are a variety of individuals involved throughout the preparations for flight and the flight itself. All of the humans involved add value and support for program success. The paper discusses the concepts of human involvement in technological programs, how a Probabilistic Risk Assessment (PRA) accounts for the human in the loop for potential missions using a technique called Human Reliability Analysis (HRA) and the tradeoffs between having a human in the loop or not. Human actions can increase or decrease the overall risk via initiating events or mitigating them, thus removing the human from the loop doesn't always lowers the risk.

DeMott, Diana L.↗

Development Specification for the Portable Life Support System (PLSS) Thermal Loop Pump

The AEMU Thermal Loop Pump Development Specification establishes the requirements for design, performance, and testing of the Water Pump as part of the Thermal System of the Advanced Portable Life Support System (PLSS). It is envisioned that the Thermal Loop Pump is a positive displacement pump that provides a repeatable volume of flow against a given range of back-pressures provided by the various applications. The intention is to operate the pump at a fixed speed for the given application. The primary system is made up of two identical and redundant pumps of which only one is in operation at given time. The Auxiliary Loop Pump is an identical pump design to the primary pumps but is operated at half the flow rate. Inlet positive pressure to the pumps is provided by the upstream Flexible Supply Assembly (FSA-431 and FSA-531) which are physically located inside the suit volume and pressurized by suit pressure. An integrated relief valve, placed in parallel to the pump's inlet and outlet protects the pump and loop from over-pressurization. An integrated course filter is placed upstream of the pump's inlet to provide filtration and prevent potential debris from damaging the pump.

Anchondo, Ian↗

Investigating the Response of Loop Plasma to Nanoflare Heating Using RADYN Simulations

We present the results of 1D hydrodynamic simulations of coronal loops that are subject to nanoflares, caused by either in situ thermal heating or nonthermal electron (NTE) beams. The synthesized intensity and Doppler shifts can be directly compared with Interface Region Imaging Spectrograph (IRIS) and Atmospheric Imaging Assembly (AIA) observations of rapid variability in the transition region (TR) of coronal loops, associated with transient coronal heating. We find that NTEs with high enough low-energy cutoff (EC) deposit energy in the lower TR and chromosphere, causing blueshifts (up to approximately 20 kilometers per second) in the IRIS Si IV lines, which thermal conduction cannot reproduce. The EC threshold value for the blueshifts depends on the total energy of the events (approximately 5 kiloelectronvolts for 1024 ergs, up to 15 kiloelectronvolts for 1025 ergs). The observed footpoint emission intensity and flows, combined with the simulations, can provide constraints on both the energy of the heating event and EC. The response of the loop plasma to nanoflares depends crucially on the electron density: significant Si IV intensity enhancements and flows are observed only for initially low-density loops (less than 10 (sup 9) per cubic centimeter). This provides a possible explanation of the relative scarcity of observations of significant moss variability. While the TR response to single heating episodes can be clearly observed, the predicted coronal emission (AIA 94 Angstroms) for single strands is below current detectability and can only be observed when several strands are heated closely in time. Finally, we show that the analysis of the IRIS Mg II chromospheric lines can help further constrain the properties of the heating mechanisms.

Sun: Corona↗

Modeling and Mitigation of Multi-Loops Related Device Overvoltage in Three Level Active Neutral Point Clamped Converter

This paper establishes an analytical model for the device drain-source overvoltage related to the two loops in three level active neutral point clamped (3L-ANPC) converters. Taking into account the non-linear device output capacitance, two commonly used modulations are investigated in detail. The result shows that the line switching frequency device usually has higher overvoltage, and the switching speed of the high switching frequency device is not strongly influenced by the multiple loops. By keeping the non-active clamping switch off, the effect of the non-linear device output capacitance can be significantly mitigated, which helps reduce the overvoltage. Moreover, the loop inductance can be reduced with vertical loop layout and magnetic cancellation in PCB and busbar design. A 500 kVA 3L-ANPC converter using SiC MOSFETs is built and tested. The experimental results validate the overvoltage model of the two modulations as well as the busbar design. With the non-active clamping switch off, the overvoltage of both the high and line switching frequency devices is significantly reduced, which helps achieve higher switching speed.

Model↗

Interrogating Solar Flare Loop Models With IRIS Observations 1: Overview of the Models, and Mass Flows

Solar flares are transient yet dramatic events in the atmosphere of the Sun, during which a vast amount of magnetic energy is liberated. This energy is subsequently transported through the solar atmosphere or into the heliosphere, and together with coronal mass ejections flares comprise a fundamental component of space weather. Thus, understanding the physical processes at play in flares is vital. That understanding often requires the use of forward modelling in order to predict the hydrodynamic and radiative response of the solar atmosphere. Those predictions must then be critiqued by observations to show us where our models are missing ingredients. While flares are of course 3D phenomenon, simulating the flaring atmosphere including an accurate chromosphere with the required spatial scales in 3D is largely beyond current computational capabilities, and certainly performing parameter studies of energy transport mechanisms is not yet tractable in 3D. Therefore, field-aligned 1D loop models that can resolve the relevant scales have a crucial role to play in advancing our knowledge of flares. In recent years, driven in part by the spectacular observations from the Interface Region Imaging Spectrograph (IRIS), flare loop models have revealed many interesting features of flares. For this review I highlight some important results that illustrate the utility of attacking the problem of solar flares with a combination of high quality observations, and state-of-the-art flare loop models, demonstrating: 1) how models help to interpret flare observations from IRIS, 2) how those observations show us where we are missing physics from our models, and 3) how the ever increasing quality of solar observations drives model improvements. Here in Paper one of this two part review I provide an overview of modern flare loop models, and of electron-beam driven mass flows during solar flares.

solar flares↗

N >= 4 Supergravity Amplitudes from Gauge Theory at Two Loops

We present the full two-loop four-graviton amplitudes in N = 4, 5, 6 supergravity. These results were obtained using the double-copy structure of gravity, which follows from the recently conjectured color-kinematics duality in gauge theory. The two-loop four-gluon scattering amplitudes in N = 0, 1, 2 supersymmetric gauge theory are a second essential ingredient. The gravity amplitudes have the expected infrared behavior: the two-loop divergences are given in terms of the squares of the corresponding one-loop amplitudes. The finite remainders are presented in a compact form. The finite remainder for N = 8 supergravity is also presented, in a form that utilizes a pure function with a very simple symbol.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing the inner loop of the gravitational force interaction on modern processors

We have achieved superior performance on multiple generations of the fastest supercomputers in the world with our hashed oct-tree N-body code (HOT), spanning almost two decades and garnering multiple Gordon Bell Prizes for significant achievement in parallel processing. Execution time for our N-body code is largely influenced by the force calculation in the inner loop. Improvements to the inner loop using SSE3 instructions has enabled the calculation of over 200 million gravitational interactions per second per processor on a 2.6 GHz Opteron, for a computational rate of over 7 Gflops in single precision (700/0 of peak). We obtain optimal performance some processors (including the Cell) by decomposing the reciprocal square root function required for a gravitational interaction into a table lookup, Chebychev polynomial interpolation, and Newton-Raphson iteration, using the algorithm of Karp. By unrolling the loop by a factor of six, and using SPU intrinsics to compute on vectors, we obtain performance of over 16 Gflops on a single Cell SPE. Aggregated over the 8 SPEs on a Cell processor, the overall performance is roughly 130 Gflops. In comparison, the ordinary C version of our inner loop only obtains 1.6 Gflops per SPE with the spuxlc compiler.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Specimens Exposed in a Li Loop

A monometallic V-4Cr-4Ti thermal convection loop was run for 2,350 h with a peak temperature of 700 C and Li flow rate of 2-3 cm/s. Specimens of V-4Cr-4Ti exposed in the hot and cold leg were tensile tested in vacuum at 500 C showing an increase in the 0.2% yield and ultimate tensile strengths and a decrease in the serration amplitude with decreasing exposure temperature in the loop. However, only minor changes in ductility were measured. With the higher temperature exposures, there was a decrease in Vickers hardness measured but little change in the grain size. Characterization of the microstructure after exposure at 627 C in the loop showed an increase in the density of Ti- and N-rich grain boundary and matrix precipitates near the specimen surface after exposure corresponding to an increase in the hardness in the near-surface region. Two-layer V/Y2O3 coatings on V-4Cr-4Ti substrates also were exposed in the loop and initial room temperature characterization has been conducted.

Unocic, Kinga A↗

Nonlinear model predictive control for chemical looping process

A control system for optimizing a chemical looping ("CL") plant includes a reduced order mathematical model ("ROM") that is designed by eliminating mathematical terms that have minimal effect on the outcome. A non-linear optimizer provides various inputs to the ROM and monitors the outputs to determine the optimum inputs that are then provided to the CL plant. An estimator estimates the values of various internal state variables of the CL plant. The system has one structure adapted to control a CL plant that only provides pressure measurements in the CL loops A and B, a second structure adapted to a CL plant that provides pressure measurements and solid levels in both loops A, and B, and a third structure adapted to control a CL plant that provides full information on internal state variables. A final structure provides a neural network NMPC controller to control operation of loops A and B.

97 MATHEMATICS AND COMPUTING↗

Prediction of Performance of a Pilot-Scale Dual Fluidized Bed System for Chemical Looping with Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a variant of chemical looping combustion that involves spontaneous release of gaseous oxygen in the fuel reactor, which enables efficient combustion of solid fuel char. The University of Utah has constructed a 200 kW pilot-scale chemical looping process development unit (PDU) consisting of two fluidized beds. The CLOU oxygen carrier uses copper as the active metal, cycling between cupric (CuO) and cuprous (Cu2O) oxides. As an aid for design, troubleshooting and evaluation of the pilot system, a CFD model has been developed using CPFD Software’s Barracuda VR software. The 3D model includes both reactors, as well as loop seals and cyclone separators. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously reported experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used preexisting relationships in the literature. Three different simulations were performed, analyzing the influence of particle properties (a base carrier and an alternate carrier referred to as cariact) and coal feeding rate (100kW, 200kW). Increased coal feeding rate caused significant increase in cuprious oxide oxidation in the air reactor as well as higher temperature. The alternate carrier predicted CO2 capture below 90%, in contrast to the other cases.

Reinking, Zachary↗

Prediction of Performance of a Pilot Scale Dual Fluidized Bed System for Chemical Looping with Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a variant of chemical looping combustion that involves spontaneous release of gaseous oxygen in the fuel reactor, which enables efficient combustion of solid fuel char. The University of Utah has constructed a pilot-scale dual fluidized bed chemical looping process development unit (PDU) with a nominal thermal input of 200 kW. The CLOU oxygen carrier uses copper as the active metal, cycling between cupric (CuO) and cuprous (Cu2O) oxides. As an aid for design, troubleshooting and evaluation of the pilot system, a CFD model has been developed using CPFD Software’s Barracuda VR software. The 3D model includes both reactors, as well as loop seals and cyclone separators. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously done experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used preexisting relationships in the literature. Results predict temperature profiles, concentration profiles, product gas composition, and CO¬2 capture efficiency. This paper presents results of a parametric study in which key operational variables were adjusted to determine the influence on simulated performance of the PDU. The adjusted variables include fuel feed rate, fuel particle size, total oxygen carrier inventory, oxygen carrier copper oxide loading, and oxygen carrier particle physical properties.

Reinking, Zachary↗

Computational fluid dynamics modeling of chemical looping combustion process with calcium sulphate oxygen carrier - article no. A19

To concentrate CO{sub 2} in combustion processes by efficient and energy-saving ways is a first and very important step for its sequestration. Chemical looping combustion (CLC) could easily achieve this goal. A chemical-looping combustion system consists of a fuel reactor and an air reactor. Two reactors in the form of interconnected fluidized beds are used in the process: (1) a fuel reactor where the oxygen carrier is reduced by reaction with the fuel, and (2) an air reactor where the reduced oxygen carrier from the fuel reactor is oxidized with air. The outlet gas from the fuel reactor consists of CO{sub 2} and H{sub 2}O, while the outlet gas stream from the air reactor contains only N{sub 2} and some unused O{sub 2}. The water in combustion products can be easily removed by condensation and pure carbon dioxide is obtained without any loss of energy for separation. Until now, there is little literature about mathematical modeling of chemical-looping combustion using the computational fluid dynamics (CFD) approach. In this work, the reaction kinetic model of the fuel reactor (CaSO{sub 4}+ H{sub 2}) is developed by means of the commercial code FLUENT and the effects of partial pressure of H{sub 2} (concentration of H{sub 2}) on chemical looping combustion performance are also studied. The results show that the concentration of H{sub 2} could enhance the CLC performance.

01 COAL, LIGNITE, AND PEAT↗

TREAT neutronics analysis of water-loop concept accommodating LWR 9-rod bundle

The Transient Reactor Test (TREAT) facility that was commissioned in 1959 and that was put in stand-by in 1994, is now facing an upgrade to provide irradiation services to a variety of experimental programs. The neutronic studies presented in this paper show that the TREAT facility is capable of performing transient tests on fresh 9-rod PWR bundles in a water loop design constructed from Inconel piping using only fuel assemblies from the original core. High burnup rods in the same proposed design configuration approach, but do not meet, energy deposition targets for narrow-pulse reactivity insertion accident testing. The option to use a Zircaloy-based water loop was evaluated and found to increase the power coupling factor (PCF) adequately, but several engineering considerations show that the Inconel loop should be considered the baseline design option until detailed design work is performed. TREAT's capabilities for steam-based LOCA testing were also evaluated and found to allow for higher specimen energy deposition than RIA tests primarily because the reactor can release more energy over longer shaped transients. The same test configurations were evaluated in the presence of a partial TREAT-upgrade (TU) core with the notable observation that TU elements can enable high burnup rods to achieve RIA energy targets with the Inconel water loop. Further observations show that the partial TU core can help recover excess reactivity as needed and flatten pin-to-pin power profiles for more prototypic test conditions. These studies demonstrate that a simple U/C atom ratio gradient implementation results in more energy deposition into the test specimen and works to flatten the rod-to-rod power profile. It is expected that the actual, specially designed TREAT upgrade core will be much more effective than this study of a modified version demonstrates and deserves a comprehensive investigation to identify true capability. Overall, the complex interplay between fuel, geometry, neutron absorbers, and moderators emphasize that the facility's capabilities are flexible and further enabled by the ability to use TU elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of a Loop for Fission Gas Release and Monitoring at the PULSTAR Reactor

Modern nuclear fuel performance analysis tools aim at establishing a predictive approach for examining macroscopic fuel behavior due to fuel gaseous swelling and the associated pellet cladding mechanical interaction (PCMI). In general, the macroscopic behavior is highly sensitive to understanding microscopically driven phenomena, which in this case is the release of fission gas (i.e., Kr and Xe) from the fuel. Previous studies identified the uncertainties associated with the intra-granular fission gas diffusion coefficient as most limiting for the accuracy of fission gas release calculations. In particular, it was concluded that, in order to improve fission gas release as well as gaseous swelling predictions using fuel performance codes, a better characterization of the diffusion coefficient is needed. This work explores the implementation of an on-line fission gas release and measurement loop at the North Carolina State University (NCSU) PULSTAR reactor. A unique characteristic of this loop is the ability to control the temperature of the fuel samples during irradiation to establish a more accurate correlation between the irradiation conditions and an observable such as the intragranular gas diffusion coefficient. Analysis was performed of an 'in-pile' fission gas release experiment that is currently under implementation at the NCSU PULSTAR reactor. Using MCNP6 calculations and COMSOL simulations the fission rate density and temperature distributions in UO{sub 2} microspheres were estimated. To explore the feasibility of detecting fission gas isotopes, estimates of R/B for {sup 138}Xe were obtained using the equivalent sphere model and combined with MCNP6 predicted B estimates to obtain R. Assuming detection in a typical gamma-ray spectrometry HPGe system, it was conclude that reasonable count rates will be achieved to allow extraction of release information. At this stage, accurate assessment is underway of the performance of various loop components to set the final design criteria in support of loop fabrication. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Obvious and non-obvious aspects of digital Self-Excited-Loops for SRF cavity control

In 1978, Delayen showed how Self-Excited Loops (SEL) can be used to great advantage for controlling narrow-band SRF cavities. Its key capability is establishing closed-loop amplitude control early in the setup process, stabilizing Lorentz forces to allow cavity tuning and phase loop setup in a stable environment. As people around the world implement this basic idea with modern FPGA DSP technology, multiple variations and operational scenarios creep in that have both obvious and non-obvious ramifications for latency, feedback stability, and resiliency. This paper will review the key properties of a Delayen-style SEL when set up for open-loop, amplitude stabilized, and phase-stabilized modes. Then the original analog circuit will be compared and contrasted with the known variations of digital CORDIC-based implementations.

Doolittle, Larry [LBL, Berkeley]↗