Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Iron Oxide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Oxidation Behavior of Binary Niobium Alloys

This investigation concludes a study to determine the effects of up to 25 atomic percent of 55 alloying additions on the oxidation characteristics of niobium. The alloys were evaluated by oxidizing in an air atmosphere for 4 hours at 1000 C and 2 hours at 1200 C. Titanium and chromium improved oxidation resistance at both evaluation conditions. Vanadium and aluminum improved oxidation resistance at 1000 C, even though the V scale tended to liquefy and the Al specimens became brittle and the scale powdery. Copper, cobalt, iron, and iridium improved oxidation resistance at 1200 C. Other investigations report tungsten and molybdenum are protective up to about 1000 C, and tantalum at 1100 C. The most important factor influencing the rate of oxidation was the ion size of the alloy additions. Ions slightly smaller than the Nb(5+) ion are soluble in the oxide lattice and tend to lower the compressive stresses in the bulk scale that lead to cracking. The solubility of the alloying addition also depends on the valence to some extent. All of the elements mentioned that improve the oxidation resistance of Nb fit this size criterion with the possible exception of Al, whose extremely small size in large concentrations would probably lead to the formation of a powdery scale. Maintenance of a crack-free bulk scale for as long as possible may contribute to the formation of a dark subscale that ultimately is rate- controlling in the oxidation process. The platinum-group metals, especially Ir, appear to protect by entrapment of the finely dispersed alloying element by the incoming Nb2O5 metal-oxide interface. This inert metallic Ir when alloyed in a sufficient amount with Yb appears to give a ductile phase dispersed in the brittle oxide. This scale would then flow more easily to relieve the large compressive stresses to delay cracking. Complex oxide formation (which both Ti and Zr tend to initiate) and valence effects, which probably change the vacancy concentration in the scale, are masked by the overriding tendency for a porous scale.

Barrett, Charles A.↗

IIAB IRON METEORITES: FORMATION AND RELATION TO OTHER METEORITE GROUPS.

The IIAB iron meteorites are one of the largest iron meteorite groups that formed by fractional crystallization [1]. Iron meteorites formed over a range of oxygen fugacities (fO2)[2], most formed relatively reduced at~ IW–4to –2.5 (IABs), where IW= iron-wüstite buffer, to relatively oxidized at IW–1(IVBs) [2,3]. While the IIABs contain reduced mineral phases (daubré elite [1]),the fO2for IIABs is poorly constrained. The fO2of iron meteorites may have become more reducing during cooling, with oxidized phases (i.e., chromite) forming at higher temperatures and daubré elite forming at lower temperatures [4]. The O-and Cr-isotope compositions of silicates and chromite in meteorites, including iron meteorites, can determine potential genetic links to other meteorite sand con-strain if a meteorite is from the non-carbonaceous (NC) or carbonaceous (CC) group [e.g., 5–8]. Iron meteorite groups have been identified as being in the NCor CC group using Mo[9]and Ni [10] isotope compositions of their metallic component. Numerous iron meteorites contain minor amounts of silicates and oxides [e.g., 11], but most have not been analyzed for their Cr or Ti isotope compositions, with some exceptions (e.g., IIIABs [6,7],a IIG, and a IIAB[7]). We analyzed the compositions of silicates and chromite in six IIAB iron meteorites to investigate the relationship between IIABs and known meteorite groups, the fO2of IIABs, and the origin of chromite in the IIABs. *full abstract in document

Meteorite↗

Fine-grained Goethite as a Precursor for Martian Gray Hematite

Several isolated deposits of gray, crystalline hematite on Mars were discovered using data returned from the Thermal Emission Spectrometer (TES) instrument aboard the Mars Global Surveyor spacecraft. Christensen et al. provided five testable hypotheses regarding the formation of crystalline hematite on Mars: 1) low-temperature precipitation of Fe oxides/hydroxides from standing, oxygenated, Fe-rich water, followed by subsequent alteration to gray hematite, 2) low-temperature leaching of iron-bearing silicates and other materials leaving a Fe-rich residue laterite-style weathering) which is subsequently altered to gray hematite, 3) direct precipitation of gray hematite from Fe-rich circulating fluids of hydrothermal or other origin, 4) formation of gray hematitic surface coatings during weathering, and 5) thermal oxidation of magnetite-rich lavas. Since this initial work, several authors have examined the hematite deposits to determine their formation mechanism. Lane et al. cited the absence of a 390/ cm absorption in the martian hematite spectrum as evidence for platy hematite grains. Their model for the formation of the deposits includes deposition of any of a variety of iron oxides or oxyhydroxides by aqueous or hydrothermal fluids, burial and metamorphosis to gray platy hematite grains, and exhumation in recent times. Based on a detailed geomorphic examination of the Sinus Meridiani region, Hynek et al. conclude that the most likely method of hematite formation was either emplacement by a hydrothermal fluid or oxidation of a magnetite-rich pyroclastic deposit. Similarly, Arvidson et al., favor a model involving the alteration of pyroclastic deposits by aqueous or hydrothermal fluids. Finally, based on geochemical modeling and an examination of Aram Chaos, Catling and Moore favor emplacement by hydrothermal fluids with a minimum temperature of 100 C. Comparison of the average martian hematite spectrum measured by TES to hematite emissivity spectra for a variety of naturally occurring hematites shows small but potentially important differences. In particular, band shapes, positions and relative band emissivities of hematite spectra vary over the range of samples. These differences imply that the natural variability of thermal infrared hematite spectra has not been fully characterized, especially with respect to the reaction pathway and crystal structure.

T D Glotch↗

Pyrite (001) Interface Chemistry is Controlled by a Sulfoxy Termination

Pyrite (FeS 2 ) is the most common sulfide mineral on Earth, forming through inorganic reactions in the crust and oceanic hydrothermal systems and via microbially driven processes in anaerobic sediments. The pyrite–water interface is the site of a wide range of adsorption and reaction processes in Earth systems including oxidation that dramatically affects the geochemistry of surface waters and influences global carbon and oxygen cycles. Mechanistic geochemical models of pyrite interfacial reactivity, however, are limited by the lack of experimentally derived atomistic structures of the reduced and reacting surfaces. Here, in this work, we reveal the atomic-scale structure of the pyrite (001)-water interface that forms at very low oxygen partial pressures, relevant to suboxic environments in Earth. The interface structure and surface speciation were obtained using the crystal truncation rod method supported by ambient-pressure photoelectron spectroscopy and density functional theory calculations. The surface is dominantly composed of disulfide groups bound to a single oxygen atom, forming a sulfoxy group that has no known molecular or bulk mineral analog. This surface is interpreted as the first step in the oxidative dissolution of pyrite. The sulfoxy group is readily protonated through surface acid–base reactions that alter the structure of interfacial water and the free energy of interfacial reactions. Surface iron sites are not oxidized. Surprisingly, this interface can likely develop in equilibrium with bulk pyrite in some reducing and acidic solutions. This termination is therefore likely representative of pyrite surfaces under a vast range of experimental, industrial and Earth conditions.

oxidation↗

The reactions of cobalt, iron and nickel in SO-2 atmospheres: Similarities and differences

The reactions of cobalt, iron and nickel in SO2 atmospheres are reviewed and compared. A mixed oxide-sulfide product layer is observed in all cases. Cobalt and nickel exhibits similar behavior. The observed rates are near the sulfidation rates, and the reaction rate is strongly influenced by the outward diffusion of metal through an interconnected sulfide network. A continuous interconnected sulfide is not observed in the oxide-sulfide scales formed on iron, and the reaction rates are more difficult to summarize. The differences and similarities among the three metals are explained in terms of the absence of scale-gas equilibrium and the ratio of the metal diffusivity in the corresponding oxide and sulfide.

Jacobson, N. S.↗

The reactions of cobalt, iron and nickel in SO2 atmospheres Similarities and differences

The reactions of cobalt, iron and nickel in SO2 atmospheres are reviewed and compared. A mixed oxide-sulfide product layer is observed in all cases. Cobalt and nickel exhibit similar behavior. The observed rates are near the sulfidation rates, and the reaction rate is strongly influenced by the outward diffusion of metal through an interconnected sulfide network. A continuous interconnected sulfide is not observed in the oxide-sulfide scales formed on iron, and the reaction rates are more difficult to summarize. The differences and similarities among the three metals are explained in terms of the absence of scale-gas equilibrium and the ratio of the metal diffusivity in the corresponding oxide and sulfide.

Jacobson, N. S.↗

Explorations of the nonheme high-valent iron-oxo landscape: crystal structure of a synthetic complex with an [Fe IV 2 (μ-O) 2 ] diamond core relevant to the chemistry of sMMOH

Methanotrophic bacteria utilize methane monooxygenase (MMO) to carry out the first step in metabolizing methane. The soluble enzymes employ a hydroxylase component (sMMOH) with a nonheme diiron active site that activates O 2 and generates a powerful oxidant capable of converting methane to methanol. It is proposed that the diiron(II) center in the reduced enzyme reacts with O 2 to generate a diferric-peroxo intermediate called P that then undergoes O–O cleavage to convert into a diiron(IV) derivative called Q, which carries out methane hydroxylation. Most (but not all) of the spectroscopic data of Q accumulated by various groups to date favor the presence of an Fe IV 2 (μ-O) 2 unit with a diamond core. The Que lab has had a long-term interest in making synthetic analogs of iron enzyme intermediates. To this end, the first crystal structure of a complex with a Fe III Fe IV (μ-O) 2 diamond core was reported in 1999, which exhibited an Fe∙∙∙Fe distance of 2.683(1) Å. Now more than 20 years later, a complex with an Fe IV 2 (μ-O) 2 diamond core has been synthesized in sufficient purity to allow diffraction-quality crystals to be grown. Finally, its crystal structure has been solved, revealing an Fe∙∙∙Fe distance of 2.711(4) Å for comparison with structural data for related complexes with lower iron oxidation states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moessbauer Spectroscopy for Lunar Resource Assessment: Measurement of Mineralogy and Soil Maturity

First-order assessment of lunar soil as a resource includes measurement of its mineralogy and maturity. Soils in which the mineral ilmenite is present in high concentrations are desirable feedstock for the production of oxygen at a lunar base. The maturity of lunar soils is a measure of their relative residence time in the upper 1 mm of the lunar surface. Increasing maturity implies increasing load of solar wind species (e.g., N, H, and He-3), decreasing mean grain size, and increasing glass content. All these physicochemical properties that vary in a regular way with maturity are important parameters for assessing lunar soil as a resource. For example, He-3 can be extracted and potentially used for nuclear fusion. A commonly used index for lunar soil maturity is I(sub s)/FeO, which is the concentration of fine-grained metal determined by ferromagnetic resonance (I(sub s)) normalized to the total iron content (as FeO). I(sub s)/FeO has been measured for virtually every soil returned by the Apollo and Luna missions to the Moon. Because the technique is sensitive to both oxidation state and mineralogy, iron Moessbauer spectroscopy (FeMS) is a viable technique for in situ lunar resource assessment. Its utility for mineralogy is apparent from examination of published FeMS data for lunar samples. From the data published, it can be inferred that FeMS data can also be used to determine soil maturity. The use of FeMS to determine mineralogy and maturity and progress on development of a FeMS instrument for lunar surface use are discussed.

Morris, R. V.↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Reactive Fe anode for electrolytic reduction of solid metal oxide in molten LiCl-Li 2 O

Iron metal was investigated for use as a consumable anode for electrolytic reduction of solid metal oxides in molten LiCl-Li 2 O (2.0 - 2.4 wt%). Tests were performed where the potential of Fe anodes was increased incrementally from 0.1 to 1.0 V (vs Ni/NiO). Oxide formation on the anode started at a potential of 0.4 V and was identified as FeO via X-ray diffraction. In the absence of a pre-formed oxide layer, severe attack of the anode started at a potential of 0.7 V and was accompanied by an increase in Fe concentration in the salt. When an oxide layer was allowed to form on the anode, the Fe concentration did not increase in the salt. O 2 was detected in the headspace gas at an anode potential of 1.0 V only when an oxide layer was present on the anode. Finally, the results of this study support the idea that an inexpensive sacrificial anode could be an ideal replacement for expensive Pt that is currently widely used for this process.

36 MATERIALS SCIENCE↗

Ultraviolet Photooxidation of Smectite-Bound Fe(II) and Implications for the Origin of Martian Nontronites

Clay minerals detected with orbital and in situ instruments in ancient Martian terrains constrain Mars' climate and aqueous alteration history. Early in its history, Mars experienced an atmospheric redox change and iron-bearing clay minerals may preserve the effects of that transition. Ferrous smectites, the thermodynamically predicted product of chemical weathering of basalts under anoxic conditions, may have undergone oxidation by exposure to chemical oxidants in the atmosphere or regolith, or by direct photooxidation at the surface. To assess these potential oxidation pathways, ferrous trioctahedral smectites of varying initial iron content were synthesized and subjected to oxidation by ultraviolet (UV) irradiation. Experimental UV irradiation under an anoxic atmosphere equivalent to approximately 7 years of flux on the Martian surface caused partial oxidation of smectite-bound Fe (Fe 3+ /ΣFe = 16–18%) and octahedral sheet contraction. Metal-OH vibrational bands in visible/near infrared (VNIR) reflectance spectra of oxidized smectites changed in band depth and asymmetry with higher iron content. X-ray diffraction patterns of UV irradiated samples indicate the formation of a mixed di- and trioctahedral smectite or a secondary nontronite phase, possibly on the surfaces of higher iron content smectites. Furthermore, these experiments suggest that UV irradiation is able to oxidize structurally bound iron in smectites without the presence of other chemical oxidants. Photooxidation may have influenced the mineralogy, both syndepositionally and postdepositionally, of Martian alteration assemblages formed near the surface and this process needs not be limited to one part of their formation history.

58 GEOSCIENCES↗

Electrolytic Coagulant Generation for Treating Flowback and Produced Water for Reuse

This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water (FPW) from hydraulic fracturing and oil production operations. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe 3+ coagulating agent, and the base is used to neutralize the treated water. The costs for generating the ferric iron coagulant were determined as a function of current density and feed water salinity. The process was shown to be effective for removing colloidal bentonite particles from brine solutions. Here, the process has several advantages over conventional electrocoagulation using iron anodes, including: the ability to treat anoxic waters, elimination of electrode fouling, lower cost for the coagulant, and the ability to deliver Fe 3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen required to oxidize ferrous to ferric iron.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Tribocharged Electrostatic Beneficiation of Lunar Simulant in Lunar Gravity

The lunar regolith has high concentrations of aluminum, silicon, calcium, iron, sodium, and titanium oxides. Liberation of these metals would provide necessary materials for structural and building material fabrication, spare part, machine and tool production, and construction and site preparation in-situ on the moon or other extraterrestrial body (Rao et al 1979). Ilmenite (FeTi03) is a mineral of interest on the moon as a source of iron, titanium, and oxygen (Cameron 1992, Zhao and Shadman 1993) and therefore enrichment of this mineral in the feedstock before processing would be a considerable advantage in reducing energy requirements to process regolith. Not only for construction materials, but shipping oxygen and water from earth is weight prohibitive, and so investigations into the potential production of oxygen from the oxides of lunar regolith are a major research initiative by NASA (Sibille et al. 2009, Moscatello et al. 2009). In this paper, the results of electrostatic beneficiation of two sets of lunar simulants on two different reduced gravity flight series are presented.

Quinn, Jacqueline W.↗

Kinetic Studies of Iron Deposition Catalyzed by Recombinant Human Liver Heavy, and Light Ferritins and Azotobacter Vinelandii Bacterioferritin Using O2 and H2O2 as Oxidants

The discrepancy between predicted and measured H2O2 formation during iron deposition with recombinant heavy human liver ferritin (rHF) was attributed to reaction with the iron protein complex [Biochemistry 40 (2001) 10832-10838]. This proposal was examined by stopped-flow kinetic studies and analysis for H2O2 production using (1) rHF, and Azotobacter vinelandii bacterial ferritin (AvBF), each containing 24 identical subunits with ferroxidase centers; (2) site-altered rHF mutants with functional and dysfunctional ferroxidase centers; and (3) rccombinant human liver light ferritin (rLF), containing 110 ferroxidase center. For rHF, nearly identical pseudo-first-order rate constants of 0.18 per second at pH 7.5 were measured for Fe(2+) oxidation by both O2 and H2O2, but for rLF, the rate with O2 was 200-fold slower than that for H2O2 (k-0.22 per second). A Fe(2+)/O2 stoichiometry near 2.4 was measured for rHF and its site altered forms, suggesting formation of H2O2. Direct measurements revealed no H2O2 free in solution 0.5-10 min after all Fe(2+) was oxidized at pH 6.5 or 7.5. These results are consistent with initial H2O2 formation, which rapidly reacts in a secondary reaction with unidentified solution components. Using measured rate constants for rHF, simulations showed that steady-state H2O2 concentrations peaked at 14 pM at approx. 600 ms and decreased to zero at 10-30 s. rLF did not produce measurable H2O2 but apparently conducted the secondary reaction with H2O2. Fe(2+)/O2 values of 4.0 were measured for AvBF. Stopped-flow measurements with AvBF showed that both H2O2 and O2 react at the same rate (k=0.34 per second), that is faster than the reactions with rHF. Simulations suggest that AvBF reduces O2 directly to H2O without intermediate H2O2 formation.

Bunker, Jared↗

Comparison of the earliest NC and CC planetesimals: Evidence from ungrouped iron meteorites

Isotope anomalies in meteorites reveal a fundamental dichotomy between Non-Carbonaceous- (NC) and Carbonaceous-type (CC) planetary bodies. Until now, this dichotomy is established for the major meteorite groups, representing about 36 distinct parent bodies. Ungrouped meteorites represent an even larger number of additional parent bodies, but whether they conform to the overall NC-CC dichotomy is unknown. Here, the genetics and chronology of 26 ungrouped iron meteorites are considered through nucleosynthetic Mo and radiogenic W isotopic compositions. Secondary cosmic ray-induced modifications of these isotope compositions are corrected using Pt isotope measurements on the same samples. We find that all of the ungrouped irons have Mo isotope anomalies within the range of the major meteorite groups and confirm the NC-CC dichotomy for Mo, where NC and CC meteorites define two distinct, subparallel s-process mixing lines. All ungrouped NC irons fall on the NC-line, which is now precisely defined for 41 distinct parent bodies. The ungrouped CC irons show scatter around the CC-line indicative of small r-process Mo heterogeneities among these samples. These r-process Mo isotope variations correlate with O isotope anomalies, most likely reflecting mixing of CI chondrite-like matrix, chondrule precursors, and Ca-Al-rich inclusions. This implies that CC iron meteorite parent bodies accreted the same nebular components as the later-formed carbonaceous chondrites. The Hf-W model ages of core formation for the ungrouped irons overlap with those of the iron meteorite groups from each reservoir and reveal a narrow age peak at ∼3.3 Ma after Ca-Al-rich inclusions for the CC irons. By contrast, the NC irons display more variable ages, including younger ages indicative of impact-induced melting events, which seem absent among the CC irons. This is attributed to the more fragile and porous nature of the CC bodies, making impact-induced melting on their surfaces difficult. The chemical characteristics of all iron meteorites together reveal slightly more oxidizing conditions during core formation for CC compared to NC irons. More strikingly, strong depletions in moderately volatile elements, typical of many iron meteorite parent bodies, predominantly occur among CC irons, for reasons that remain unclear at present.

Chondrite components↗

Moessbauer spectrometer for mineralogical analysis of the Mars surface: Moessbauer source considerations

Development of space rocketry and cosmic instrument making has made it possible to create interplanetary stations to be sent to the solar system bodies. In the last decade of the century the planet Mars will be in the focus of planetary science problems. Russia, USA (the NASA) and Europe (the ESA) plan to do a new step in the study of the planetary system by spacecraft missions to Mars. One part of the programs of these missions is Martian surface measurements of iron, which is a dominant element in both the Martian soil and rocks (about 13 percent by weight). The chemistry of iron in space is strongly coupled to the chemistry of abundant elements (to begin with hydrogen, carbon, oxygen) and it is this coupling of chemical cycles of abundant elements that gives us the possibility of understanding some features of the chemical evolution of matter. In this connection of extremely great importance for the understanding of the evolution of the solar system are the oxidation state of the iron and its mineral composition of the Mars surface. Being highly successful, the Viking landers had no instrumentation to answer these questions. Such instrumentation has to be specifically sensitive to mineralogy. For this purpose the back scattering Moessbauer spectrometer (MS-96) was proposed to be installed on a rover to be launched on board the Russian spacecraft Mars-96 mission to Mars. Due to power and mass restrictions three systems of the device MS-96 (velocity transducer, detector and electronic components) have been extremely miniaturized in comparison to a standard system. In this paper we intend to place for consideration a radioactive source to find out what characteristics it should have to be suitable for purposes of the experiment.

Evlanov, E. N.↗