Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials

An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN{sub 2}) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C{sub 60} was used to test the sample cooling unit. It shows that the phase of the C{sub 60} film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

36 MATERIALS SCIENCE↗

Evaluation of risk from space radiation with high-energy heavy ion beams

The most challenging radiation in space consists of fully ionized atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in shield materials is poorly understood since there are few human data and a systematic study in relevant animal model systems has not been made. The accuracy of risk prediction is described as the major limiting factor in the management of space radiation risk. The expected impact of systematic studies is examined using the limited available biological data and models. Given the limitations of current predictions, models must be developed that are able to incorporate the required fundamental scientific data into accurate risk estimates. The important radiation components that can be provided for laboratory testing are identified. The use of ground-based accelerator beams to simulate space radiation is explained and quantitative scientific constraints on such facilities are derived. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjuction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required.

NASA Discipline Radiation Health↗

Isotope Effects in Low Energy Ion-Atom Collisions

Isotope effects for charge transfer processes have recently received increased attention. The ion-atom merged-beams apparatus at Oak Ridge National Laboratory is used to measure charge transfer for low energy collisions of multi-charged ions with H and D and is therefore well suited to investigate isotope effects. The apparatus has been relocated and upgraded to accept high velocity beams from the 250 kV High Voltage Platform at the Multi-Charged Ion Research Facility. The intense higher velocity multi-charged ion beams allow, for the first time, measurements with both H and D from keV/u down to meV/u collision energies in the center-of-mass frame. When charge transfer occurs at relatively large inter-nuclear distances (via radial couplings) the ion-induced dipole attraction can lead to trajectory effects, causing differences in the charge transfer cross sections for H and D. A strong isotope effect (nearly a factor of two) has been observed in the cross section for Si{sup 4+}+H(D) below 0.1 eV/u. However, little or no difference is observed for N{sup 2+}+H(D). Recently, strong effects have been predicted for the fundamental system He{sup 2+}+H(D,T) at collision energies below 200 eV/u where charge transfer occurs primarily through united-atom rotational coupling. We are currently exploring systems where rotational coupling is important and isotopic differences in the cross section can be observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Fluorination on Lithium Transport and Short-Range Order in Disordered-Rocksalt-Type Lithium-Ion Battery Cathodes

Fluorine substitution is a critical enabler for improving the cycle life and energy density of disordered rocksalt (DRX) Li-ion battery cathode materials which offer prospects for high energy density cathodes, without the reliance on limited mineral resources. Due to the strong Li–F interaction, fluorine also is expected to modify the short-range cation order in these materials which is critical for Li-ion transport. In this work, density functional theory and Monte Carlo simulations are combined to investigate the impact of Li–F short-range ordering on the formation of Li percolation and diffusion in DRX materials. Additionally, the modeling reveals that F substitution is always beneficial at sufficiently high concentrations and can, surprisingly, even facilitate percolation in compounds without Li excess, giving them the ability to incorporate more transition metal redox capacity and thereby higher energy density. It is found that for F levels below 15%, its effect can be beneficial or disadvantageous depending on the intrinsic short-range order in the unfluorinated oxide, while for high fluorination levels the effects are always beneficial. Using extensive simulations, a map is also presented showing the trade-off between transition-metal capacity, Li-transport, and synthetic accessibility, and two of the more extreme predictions are experimentally confirmed.

25 ENERGY STORAGE↗

Self-consistent modeling of radio-frequency plasma generation in stellarators

A self-consistent model of radio-frequency (RF) plasma generation in stellarators in the ion cyclotron frequency range is described. The model includes equations for the particle and energy balance and boundary conditions for Maxwell’s equations. The equation of charged particle balance takes into account the influx of particles due to ionization and their loss via diffusion and convection. The equation of electron energy balance takes into account the RF heating power source, as well as energy losses due to the excitation and electron-impact ionization of gas atoms, energy exchange via Coulomb collisions, and plasma heat conduction. The deposited RF power is calculated by solving the boundary problem for Maxwell’s equations. When describing the dissipation of the energy of the RF field, collisional absorption and Landau damping are taken into account. At each time step, Maxwell’s equations are solved for the current profiles of the plasma density and plasma temperature. The calculations are performed for a cylindrical plasma. The plasma is assumed to be axisymmetric and homogeneous along the plasma column. The system of balance equations is solved using the Crank-Nicholson scheme. Maxwell’s equations are solved in a one-dimensional approximation by using the Fourier transformation along the azimuthal and longitudinal coordinates. Results of simulations of RF plasma generation in the Uragan-2M stellarator by using a frame antenna operating at frequencies lower than the ion cyclotron frequency are presented. The calculations show that the slow wave generated by the antenna is efficiently absorbed at the periphery of the plasma column, due to which only a small fraction of the input power reaches the confinement region. As a result, the temperature on the axis of the plasma column remains low, whereas at the periphery it is substantially higher. This leads to strong absorption of the RF field at the periphery via the Landau mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring Curved Crystal Performance for a High Resolution, Imaging X-ray Spectrometer

This paper describes the design, crystal selection, and crystal testing for a vertical Johann spectrometer operating in the 13 keV range to measure ion Doppler broadening in inertial confinement plasmas. The spectrometer is designed to use thin, curved, mica crystals to achieve a resolving power of E/ΔE>2000. A number of natural mica crystals were screened for flatness and X-ray diffraction width to find samples of sufficient perfection for use in the instrument. Procedures to select and mount high quality mica samples are discussed. A diode-type X-ray source coupled to a dual goniometer arrangement was used to measure the crystal reflectivity curve. A procedure was developed for evaluating the goniometer performance using a set of diffraction grade Si crystals. This goniometer system was invaluable for identifying the best original crystals for further use and developing the techniques to select satisfactory curved crystals for the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of He Ion Irradiation in Simple Borosilicate Glasses for HLW Immobilisation - 20324

High-level radioactive waste (HLW) consists of fission products and minor actinides. Borosilicate glass is the host material of choice in most countries to safely immobilize HLW, followed by eventual geological disposal. HLW glasses will experience both self-heating and self-irradiation effects due to the decay of fission products and minor actinides present therein. During the first 500 years of geological disposal, beta-gamma decay will be the main source of radiation due to short half-lives of fission products, as compared to very long-lived actinides which will be responsible for irradiation over much longer timescales. High-energy alpha particles and alpha recoil nuclei can potentially have significant impact (stored energy, volume change, accumulated dose, chemical durability) on the performance of the wasteform over longer timescales. Thus, to ensure safe and economic disposal over geological periods (10{sup 4} - 10{sup 6} years), the assessment of performance and properties in terms of radiation effects becomes indispensable. This work aims to simulate the effects of alpha decay in radioactive waste glasses. Two international glasses, namely UK 'MW' lithium-sodium borosilicate and Indian sodium-barium borosilicate, which are being used as HLW immobilization matrices by the UK and India respectively, were prepared by a melt-quench method and annealed below their glass transition temperatures. Both glasses were irradiated with 650 KeV He{sup 2+} ions with doses ranging from 10{sup 15} to 10{sup 17} ions/cm{sup 2}. Structural analysis was carried out using electron paramagnetic resonance (EPR) and Raman spectroscopies. First derivative continuous wave EPR spectra were recorded for all pristine and irradiated glass monoliths at room temperature using an X-band (frequency 9.6 GHz) EPR Bruker spectrometer. Results from EPR analyses showed the formation of irradiation induced paramagnetic centers at g ∼ 2.00 in all irradiated glasses. Raman spectra of pristine and irradiated samples were acquired, and showed notable changes in glass structure post-irradiation, with the emergence of a broad Raman band at 1560 cm{sup -1} upon irradiation with high fluences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application.

07 ISOTOPE AND RADIATION SOURCES↗

HIGH ENERGY DENSITY PHYSICS EXPERIMENTS WITH INTENSE HEAVY ION BEAMS

The US heavy ion fusion science program has developed techniques for heating ion-beam-driven warm dense matter (WDM) targets. The WDM conditions are to be achieved by combined longitudinal and transverse space-charge neutralized drift compression of the ion beam to provide a hot spot on the target with a beam spot size of about 1 mm, and pulse length about 1-2 ns. As a technique for heating volumetric samples of matter to high energy density, intense beams of heavy ions are capable of delivering precise and uniform beam energy deposition dE/dx, in a relatively large sample size, and the ability to heat any solid-phase target material. Initial experiments use a 0.3 MeV K+ beam (below the Bragg peak) from the NDCX-I accelerator. Future plans include target experiments using the NDCX-II accelerator, which is designed to heat targets at the Bragg peak using a 3-6 MeV lithium ion beam. The range of the beams in solid matter targets is about 1 micron, which can be lengthened by using porous targets at reduced density. We have completed the fabrication of a new experimental target chamber facility for WDM experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. The target diagnostics include a fast multi-channel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. Initial WDM experiments will heat targets by compressed NDCX-I beams and will explore measurement of temperature and other target parameters. Experiments are planned in areas such as dense electronegative targets, porous target homogenization and two-phase equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimated radiactive and shock loading of fusion reactor armor

Inertial confinement fusion (ICF) is of interest as a source of neutrons for proliferation-resistant and high burn-up fission reactor designs. ICF is a transient process, each implosion leading to energy release over a short period, with a continuous series of ICF operations needed to drive the fission reactor. ICF yields energy in the form of MeV-range neutrons and ions, and thermal x-rays. These radiations, particularly the thermal x-rays, can deposit a pulse of energy in the wall of the ICF chamber, inducing loading by isochoric heating (i.e. at constant volume before the material can expand) or by ablation of material from the surface. The explosion of the hot ICF system, and the compression of any fill material in the chamber, may also result in direct mechanical loading by a blast wave (decaying shock) reaching the chamber wall. The chamber wall must be able to survive the repetitive loading events for long enough for the reactor to operate economically. It is thus necessary to understand the loading induced by ICF systems in possible chamber wall designs, and to predict the response and life time of the wall. Estimates are given for the loading induced in the wall armor of the fusion chamber caused by ablative thermal radiation from the fusion plasma and by the hydrodynamic shock. Taking a version of the LIFE design as an example, the ablation pressure was estimated to be {approx}0.6 GPa with an approximately exponential decay with time constant {approx}0.6 ns. Radiation hydrodynamics simulations suggested that ablation of the W armor should be negligible.

42 ENGINEERING↗

Dopant distribution in high fluence Fe implanted GaN

Undoped wurtzite GaN epilayers implanted at room temperature with 50-325 keV Fe{sup +} ions in the fluence range of 10{sup 15}-10{sup 17} ions/cm{sup 2} are studied by a combination of Rutherford backscattering/channeling spectrometry and time-of-flight elastic recoil detection analysis. The results show an enhanced Fe concentration close to the surface for high ion fluences (>1x10{sup 16} cm{sup -2}), which increases with the ion fluence. Annealing at 800 deg. C for 30 min has a negligible effect on the Fe distribution in the material bulk, but further increases the Fe concentration near the surface. Our findings can be understood by radiation enhanced diffusion during ion implantation and an increased Fe diffusivity in the near surface region with distorted stoichiometry, or formation of secondary phases and precipitates for the highest doses. The simulation shows that, if enhanced diffusion is the reason for Fe buildup at the surface, both radiation enhanced diffusion and the thermal diffusion of Fe atoms near the surface, need to be at least five times larger than ordinary bulk diffusion to explain the increased Fe surface concentration.

36 MATERIALS SCIENCE↗

Li iontronics in single-crystalline T-Nb2O5 thin films with vertical ionic transport channels

Abstract The niobium oxide polymorph T -Nb 2 O 5 has been extensively investigated in its bulk form especially for applications in fast-charging batteries and electrochemical (pseudo)capacitors. Its crystal structure, which has two-dimensional (2D) layers with very low steric hindrance, allows for fast Li-ion migration. However, since its discovery in 1941, the growth of single-crystalline thin films and its electronic applications have not yet been realized, probably due to its large orthorhombic unit cell along with the existence of many polymorphs. Here we demonstrate the epitaxial growth of single-crystalline T -Nb 2 O 5 thin films, critically with the ionic transport channels oriented perpendicular to the film’s surface. These vertical 2D channels enable fast Li-ion migration, which we show gives rise to a colossal insulator–metal transition, where the resistivity drops by 11 orders of magnitude due to the population of the initially empty Nb 4 d 0 states by electrons. Moreover, we reveal multiple unexplored phase transitions with distinct crystal and electronic structures over a wide range of Li-ion concentrations by comprehensive in situ experiments and theoretical calculations, which allow for the reversible and repeatable manipulation of these phases and their distinct electronic properties. This work paves the way for the exploration of novel thin films with ionic channels and their potential applications.

Chemistry↗

Radiation damage formation in InP, InSb, GaAs, GaP, Ge, and Si due to fast ions

The basic physical mechanisms of damage formation in semiconductors due to swift heavy ion (SHI) irradiation are not yet fully understood. In the present paper damage evolution and the formation of ion tracks during SHI irradiation in InP, InSb, GaAs, GaP, and Ge are investigated for irradiation with Xe or Au ions having specific energies ranging from about 0.8 to 3 MeV/u. Based on these experimental results and those obtained by other authors for cluster-ion irradiation of InP, GaAs, Ge, and Si, extensive calculations were performed in the framework of the thermal spike model. As we published previously, the model was extended to correctly treat processes being specific to semiconductors. Additionally, the computer code was modified to perform calculations for cluster ions too. The calculated track radii are compared with those measured for the various irradiation conditions. Thereby, one unknown parameter in the calculations was determined by fitting one data point. With this procedure a very good agreement between calculated and measured track radii is obtained for InP, Ge, and Si irradiated under various conditions. This implies that the extended thermal spike model is well capable to explain track formation in SHI irradiated semiconductors. Furthermore, special experiments were performed, the results of which also support the thermal spike model of ion track formation and contradict competing mechanisms such as Coulomb explosion, shock waves, or lattice relaxation. Thus, visible (amorphous/heavily damaged) ion tracks occur if the electronic energy deposition per ion and unit length clearly exceeds the threshold value necessary for melting. This is possible for elemental ion irradiation of InP and InSb. In Ge and Si (and probably also in GaAs and GaP) the energy deposition necessary for melting is that high that it cannot be reached by elemental ion irradiation. Moreover, at least in InP and GaAs ion tracks can be formed also in a subthreshold irradiation regime if the material is predamaged. This suggests that the existence of point defects and clusters of point defects in the crystal lattice noticeably increases the electron-phonon coupling efficiency, resulting in a more efficient energy transfer to the lattice. Within the thermal spike model, this means that for a given electronic energy deposition in the predamaged crystal a higher temperature is reached than in the perfect one.

36 MATERIALS SCIENCE↗

Nanocrystalline Ba{sub 0.97}Ca{sub 0.03}SO{sub 4}:Eu for ion beams dosimetry

Nanoparticles of Ba{sub 0.97}Ca{sub 0.03}SO{sub 4}:Eu have been irradiated by 48 MeV Li{sup 3+}, 75 MeV C{sup 6+}, and 90 MeV O{sup 7+} ion beams with a fluence range of 1x10{sup 9}-1x10{sup 13} ion/cm{sup 2}. The thermoluminescence (TL) glow curves along with the response curves of this nanophosphor have been investigated and compared with those of the corresponding microcrystalline samples. TL glow curve of the nanophosphor exposed to {gamma}-rays has also been included in the letter with the aim of reporting some of the comparative measurements. The glow curves of the ion-beam irradiated nanomaterials are similar in their shapes to those induced by gamma rays, with a shift in the peak positions to the higher temperature side by around 30 K. The TL intensity of the ion-beam irradiated nanomaterials is found to decrease, while going from low to high atomic number (Z) ions (i.e., Li{sup 3+}{yields}O{sup 7+}). Similar trend was also observed in the linearity of the TL response curves. The response curve of Li ion irradiated nanomaterials is sublinear in the whole range of studied fluences. C ion has also a more or less similar response, while the O ion has a sublinear response over a shorter range of 1x10{sup 9}-1x10{sup 12} ion/cm{sup 2}, and above this range the response saturates. These results for the nanomaterials are much better than that of the corresponding microcrystalline sample irradiated by Li{sup 3+} ions. The curve was sublinear up to the fluence 1x10{sup 10} ion/cm{sup 2} and then saturates at higher fluences. The wider sublinear TL response of the nanocrystalline Ba{sub 0.97}Ca{sub 0.03}SO{sub 4}:Eu makes it superior to its corresponding microform and thus makes it a suitable candidate as a dosimeter to be used for detecting the doses of ions, especially the Li and C ions for their application in cancer radiotherapy and radiation biology.

36 MATERIALS SCIENCE↗

Effects of Stopping Ions and LET Fluctuations on Soft Error Rate Prediction.

Variability in energy deposition from stopping ions and LET fluctuations is quantified for specific radiation environments. When compared to predictions using average LET via CREME96, LET fluctuations lead to an order-of-magnitude difference in effective flux and a nearly 4x decrease in predicted soft error rate (SER) in an example calculation performed on a commercial 65 nm SRAM. The large LET fluctuations reported here will be even greater for the smaller sensitive volumes that are characteristic of highly scaled technologies. End-of-range effects of stopping ions do not lead to significant inaccuracies in radiation environments with low solar activity unless the sensitivevolume thickness is 100 μm or greater. In contrast, end-of-range effects for stopping ions lead to significant inaccuracies for sensitive- volume thicknesses less than 10 μm in radiation environments with high solar activity.

42 ENGINEERING↗

Investigation of DOTA-Metal Chelation Effects on the Chemical Shift of 129 Xe

Recent work has shown that xenon chemical shifts in cryptophane-cage sensors are affected when tethered chelators bind to metals. Here in this paper, we explore the xenon shifts in response to a wide range of metal ions binding to diastereomeric forms of 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) linked to cryptophane-A. The shifts induced by the binding of Ca 2+ , Cu 2+ , Ce 3+ , Zn 2+ , Cd 2+ , Ni 2+ , Co 2+ , Cr 2+ , Fe 3+ , and Hg 2+ are distinct. In addition, the different responses of the diastereomers for the same metal ion indicate that shifts are affected by partial folding with a correlation between the expected coordination number of the metal in the DOTA complex and the chemical shift of 129 Xe. Lastly, these sensors may be used to detect and quantify many important metal ions, and a better understanding of the basis for the induced shifts could enhance future designs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural stability and mechanical behavior of FeNiMnCr high entropy alloy under ion irradiation

In recent years, high entropy alloys (HEAs) have attracted significant attention due to their excellent mechanical properties and good corrosion resistance, making them potential candidates for high temperature fission and fusion structural applications. However there is very little known about their radiation resistance, particularly at elevated temperatures relevant for energy applications. In the present study, a single phase (face centered cubic) concentrated solid solution alloy of composition 27%Fe-28%Ni-27%Mn-18%Cr was irradiated with 3 or 5.8 MeV Ni ions at temperatures ranging from room temperature to 700 °C and midrange doses from 0.03 to 10 displacements per atom (dpa). Transmission electron microscopy (TEM), scanning transmission electron microscopy with energy dispersive x-ray spectrometry (STEM/EDS) and X-ray diffraction (XRD) were used to characterize the radiation defects and microstructural changes. Irradiation at higher temperatures showed evidence of relatively sluggish solute diffusion with limited solute depletion or enrichment at grain boundaries. The main microstructural feature at all temperatures was high-density small dislocation loops. Voids were not observed at any irradiation condition. Nano-indentation tests on specimens irradiated at room temperature showed a rapid increase in hardness ~35% and ~80% higher than the unirradiated value at 0.03 and 0.3 dpa midrange doses, respectively. The irradiation-induced hardening was less pronounced for 500 °C irradiations (<20% increase after 3 dpa). Overall, the examined HEA material exhibits superior radiation resistance compared to conventional single phase Fe-Cr-Ni austenitic alloys such as stainless steels. Furthermore, the present study provides insight on the fundamental irradiation behavior of a single phase HEA material over a broad range of irradiation temperatures.

36 MATERIALS SCIENCE↗

Theoretical energy level spectra and transition data for 4p{sup 6}4d, 4p{sup 6}4f and 4p{sup 5}4d{sup 2} configurations of W{sup 37+} ion

The ab initio quasirelativistic Hartree-Fock method developed specifically for the calculation of spectral parameters of heavy atoms and highly charged ions was applied to determine atomic data for tungsten ions. The correlation effects were included by adopting the configuration interaction method. The Breit-Pauli approximation for quasirelativistic Hartree-Fock radial orbitals was employed to take into account relativistic effects. The energy level spectra, radiative lifetimes, Lande factors g were calculated for the 4p{sup 6}4d, 4p{sup 6}4f and 4p{sup 5}4d{sup 2} configurations of W{sup 37+} ion. The atomic data, namely, the transition wavelengths, spontaneous emission rates and oscillator strengths for the electric dipole, electric quadrupole and magnetic dipole transitions among and within the levels of these configurations are tabulated.

74 ATOMIC AND MOLECULAR PHYSICS↗