Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Identification of {gamma} rays from {sup 172}Au and {alpha} decays of {sup 172}Au, {sup 168}Ir, and {sup 164}Re

The very neutron deficient odd-odd nucleus {sup 172}Au was studied in reactions of 342 and 348 MeV {sup 78}Kr beams with an isotopically enriched {sup 96}Ru target. The {alpha} decays previously reported for {sup 172}Au were confirmed and the decay chain extended down to {sup 152}Tm through the discovery of a new {alpha}-decaying state in {sup 164}Re[E{sub {alpha}}=5623(10) keV; t{sub 1/2}=864{sub -110}{sup +150} ms; b{sub {alpha}}=3(1)%]. Fine structure in these {alpha} decays of {sup 172}Au and {sup 168}Ir were identified. A new {alpha}-decaying state was also observed and assigned as the ground state in {sup 172}Au[E{sub {alpha}}=6762(10) keV; t{sub 1/2}=22{sub -5}{sup +6} ms]. This decay chain was also correlated down to {sup 152}Tm through previously reported {alpha} decays. Prompt {gamma} rays from excited states in {sup 172}Au have been identified using the recoil-decay tagging technique. The partial level scheme constructed for {sup 172}Au indicates that it has an irregular structure. Possible configurations of the {alpha}-decaying states in {sup 172}Au are discussed in terms of the systematics of nuclei in this region and total Routhian surface calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New high-spin isomer and quasiparticle-vibration coupling in {sup 187}Ir

The high-spin structure of the Z=77 nucleus {sup 187}Ir has been studied using the fusion-evaporation reaction {sup 186}W({sup 7}Li6n) at a beam energy of 59 MeV. The excitation scheme of this nucleus has been extended by more than 110 new states, including extensions of all previously established rotational bands. The band crossing region of the h{sub 9/2} negative-parity yrast band has been revised and new intrinsic high-K states have been identified. In particular, a 29/2{sup -} isomeric state [T{sub 1/2}=1.8(5)mus] at an excitation energy of 2487 keV has been observed for the first time, and on top of it, a rich level scheme reaching up to spin (59/2{sup -}) and excitation energies around 7 MeV has been established.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Minimal uncertainty in momentum: The effects of IR gravity on quantum mechanics

The effects of the IR aspects of gravity on quantum mechanics is investigated. At large distances where, due to gravity, the space-time is curved, there appears nonzero minimal uncertainty {delta}p{sub 0} in the momentum of a quantum mechanical particle. We apply the minimal uncertainty momentum to some quantum mechanical interferometry examples and show that the phase shift depends on the area surrounded by the path of the test particle. We also put some limits on the related parameters. This prediction may be tested through future experiments. The assumption of minimal uncertainty in momentum can also explain the anomalous excess of the mass of the Cooper pair in a thin, rotating, superconductor ring.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU(2) lattice gluon propagator: Continuum limit, finite-volume effects, and infrared mass scale m{sub IR}

We study the scaling behavior and finite (physical) volume effects as well as the Gribov copy dependence of the SU(2) Landau gauge gluon propagator on the lattice. Our physical lattice sizes range from (3.0 fm){sup 4} to (7.3 fm){sup 4}. Considering lattices with decreasing lattice spacing but fixed physical volume we confirm (nonperturbative) multiplicative renormalizability and the approach to the continuum limit for the renormalized gluon propagator D{sub ren}(p) at momenta |p| > or approx. 0.6 GeV. The finite-volume effects and Gribov copy influence turn out small in this region. On the contrary, in the deeper infrared we found the Gribov copy influence strong and finite-volume effects, which still require special attention. The gluon propagator does not seem to be consistent with a simple polelike behavior {approx}(p{sup 2}+m{sub g}{sup 2}){sup -1} for momenta |p| < or approx. 0.6 GeV. Instead, a Gaussian-type fit works very well in this region. From its width - for a physical volume (5.0 fm){sup 4} - we estimate a corresponding infrared (mass) scale to be m{sub IR{approx}}0.7 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First law of thermodynamics in IR modified Horava-Lifshitz gravity

We study the first law of thermodynamics in IR modified Horava-Lifshitz spacetime. Based on the Bekenstein-Hawking entropy, we obtain the integral formula and the differential formula of the first law of thermodynamics for the Kehagias-Sfetsos black hole by treating {omega} as a new state parameter and redefining a mass that is just equal to M{sub ADM} obtained by Myung [32] if we take {alpha}=3{pi}/8.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Weyl Semimetallic Phase in Thin Films of Eu 2 Ir 2 O 7

The interplay between electronic interactions and strong spin-orbit coupling is expected to create a plethora of fascinating correlated topological states of quantum matter. Of particular interest are magnetic Weyl semimetals originally proposed in the pyrochlore iridates, which are only expected to reveal their topological nature in thin film form. To date, however, direct experimental demonstrations of these exotic phases remain elusive, due to the lack of usable single crystals and the insufficient quality of available films. Here, in this study, we report on the discovery of signatures for the long-sought magnetic Weyl semimetallic phase in (111)-oriented Eu 2 Ir 2 O 7 high-quality epitaxial thin films. We observed an intrinsic anomalous Hall effect with colossal coercivity but vanishing net magnetization, which emerges right below the onset of a peculiar magnetic phase with all-in-all-out (AIAO) antiferromagnetic ordering. The anomalous Hall conductivity obtained experimentally is consistent with the theoretical prediction, likely arising from the nonzero Berry curvature emanated by Weyl node pairs near the Fermi level that act as sources and sinks of Berry flux, activated by broken cubic crystal symmetry at the top and bottom terminations of the thin film.

36 MATERIALS SCIENCE↗

Steplike metamagnetic transitions in a honeycomb lattice antiferromagnet Tb 2 Ir 3 Ga 9

Single crystals of a honeycomb lattice antiferromagnet, Tb 2 Ir 3 Ga 9 , were synthesized, and the physical properties have been studied. From magnetometry, a long-range antiferromagnetic ordering at ≈12.5 K with highly anisotropic magnetic behavior was found. Neutron powder diffraction confirms that the Tb spins lie along the a-axis, parallel to the shortest Tb-Tb contact. Two field-induced spin-flip transitions are observed when the field is applied parallel to this axis, separated by a plateau corresponding roughly to M ≈ M s /2. Transport measurements show the resistivity to be metallic with a discontinuity at the onset of Néel order. Heat capacity shows a λ-like transition confirming the bulk nature of the magnetism.We propose a phenomenological spin Hamiltonian that describes the magnetization plateau as a result of strong Ising character arising from a quasidoublet ground state of the Tb 3+ ion in a site of C s symmetry and expressing a significant bond-dependent anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In Situ Diffuse Reflectance IR Spectroscopy and X-ray Absorption Spectroscopy for Fast Catalytic Processes

A new instrument for synchronous in situ investigations of catalytic materials by IR and X-ray absorption spectroscopies was designed and built at the X18A beamline of the National Synchrotron Light Source of Brookhaven National Laboratory. It provides analytical tools for solving structural, electronic and kinetic problems in catalysis science by two complementary methods. Among the features attractive for catalysis research are the broad range of catalytically active elements that can be investigated (starting with Ni and beyond), the wide range of reaction conditions (temperatures up to 873 K, various reactive gases) and time scales (starting from tens of seconds). The results of several representative experiments that illustrate the attractive capabilities of the new set-up are discussed.

43 PARTICLE ACCELERATORS↗

3D Mechanical Analysis of a Compact Nb 3 Sn IR Quadrupole for EIC

Abstract-The Electron Ion Collider (EIC) will require large aperture quadrupole magnets for the Hadron beam in the insertion region. Key requirements include high field, compact size, and tight control of the fringe fields. A 120 mm aperture, 308.4 mm outer diameter actively shielded Nb 3 Sn quadrupole model is under development to support these goals. This work is being carried out by a collaboration of BNL, JLAB and LBNL. A compact shell-based structure preloaded with a bladder and key system was developed for this project. In this paper, the effect of the compact structure on the mechanical behavior was investigated. In particular, the impact of the assembly tolerances and coil size variations on the actual coil stresses and bladder pressures was computed and compared with results from larger bladder and key structures developed for the LHC IR. The longitudinal preload is provided by stainless steel rods. Differently from other bladder and key magnets, the rods are first preloaded axially before coil axial load is applied. This new design aims to increase the overall stiffness of the system and reduce the longitudinal coil displacement during powering. Based on the results of a 3D mechanical analysis, the preliminary preload targets for the EIC quadrupole assembly will be reviewed and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An optical to IR sky brightness model for the LSST

To optimize the observing strategy of a large survey such as the LSST, one needs an accurate model of the night sky emission spectrum across a range of atmospheric conditions and from the near-UV to the near-IR. We have used the ESO SkyCalc Sky Model Calculator to construct a library of template spectra for the Chilean night sky. The ESO model includes emission from the upper and lower atmosphere, scattered starlight, scattered moonlight, and zodiacal light. We have then extended the ESO templates with an empirical fit to the twilight sky emission as measured by a Canon all-sky camera installed at the LSST site. With the ESO templates and our twilight model we can quickly interpolate to any arbitrary sky position and date and return the full sky spectrum or surface brightness magnitudes in the LSST filter system. Comparing our model to all-sky observations, we find typical residual RMS values of ±0.2-0.3 magnitudes per square arcsecond.

79 ASTRONOMY AND ASTROPHYSICS↗

Co-timing UV and IR laser pulses on the OMEGA EP laser system

Independently managing the timing of individual beams so they all arrive at the target within 10 ps of the time specified by the principal investigator is crucial to the success of experiments on the OMEGA EP Laser System. A streak camera is used to observe the x rays emitted when the laser beams strike a gold target, while an optical streak camera is used to measure the UV pulses. Furthermore correlating the signal on the two instruments gives a timing accuracy of 10 ps for the short pulse IR beams and 20 ps for the long-pulse UV beams.

42 ENGINEERING↗

Near-field probing of strong light-matter coupling in single IR antennae

Quantum well intersubband polaritons are traditionally studied in large scale ensembles, over many wavelengths in size.In this presentation, we demonstrate that it is possible to detect and investigate intersubband polaritons in a single sub-wavelength nanoantenna in the IR frequency range. We observe polariton formation using a scattering-type near-fieldmicroscope and nano-FTIR spectroscopy. In this work, we will discuss near-field spectroscopic signatures of plasmonic antennae withand without coupling to the intersubband transition in quantum wells located underneath the antenna. Evanescent fieldamplitude spectra recorded on the antenna surface show a mode anti-crossing behavior in the strong coupling case. Wealso observe a corresponding strong-coupling signature in the phase of the detected field. We anticipate that this near-fieldapproach will enable explorations of strong and ultrastrong light-matter coupling in the single nanoantenna regime,including investigations of the elusive effect of ISB polariton condensation.

36 MATERIALS SCIENCE↗

Air kerma standard for calibration of well-type chambers in Brazil using {sup 192}Ir HDR sources and its traceability

In Brazil there are over 100 high dose rate (HDR) brachytherapy facilities using well-type chambers for the determination of the air kerma rate of {sup 192}Ir sources. This paper presents the methodology developed and extensively tested by the Laboratorio de Ciencias Radiologicas (LCR) and presently in use to calibrate those types of chambers. The system was initially used to calibrate six well-type chambers of brachytherapy services, and the maximum deviation of only 1.0% was observed between the calibration coefficients obtained and the ones in the calibration certificate provided by the UWADCL. In addition to its traceability to the Brazilian National Standards, the whole system was taken to University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) for a direct comparison and the same formalism to calculate the air kerma was used. The comparison results between the two laboratories show an agreement of 0.9% for the calibration coefficients. Three Brazilian well-type chambers were calibrated at the UWADCL, and by LCR, in Brazil, using the developed system and a clinical HDR machine. The results of the calibration of three well chambers have shown an agreement better than 1.0%. Uncertainty analyses involving the measurements made both at the UWADCL and LCR laboratories are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a fiber-coupled Al{sub 2}O{sub 3}:C luminescence dosimetry system for online in vivo dose verification during {sup 192}Ir brachytherapy

A prototype of a new dose-verification system has been developed to facilitate prevention and identification of dose delivery errors in remotely afterloaded brachytherapy. The system allows for automatic online in vivo dosimetry directly in the tumor region using small passive detector probes that fit into applicators such as standard needles or catheters. The system measures the absorbed dose rate (0.1 s time resolution) and total absorbed dose on the basis of radioluminescence (RL) and optically stimulated luminescence (OSL) from aluminum oxide crystals attached to optical fiber cables (1 mm outer diameter). The system was tested in the range from 0 to 4 Gy using a solid-water phantom, a Varian GammaMed Plus {sup 192}Ir PDR afterloader, and dosimetry probes inserted into stainless-steel brachytherapy needles. The calibrated system was found to be linear in the tested dose range. The reproducibility (one standard deviation) for RL and OSL measurements was 1.3%. The measured depth-dose profiles agreed well with the theoretical expectations computed with the EGSNRC Monte Carlo code, suggesting that the energy dependence for the dosimeter probes (relative to water) is less than 6% for source-to-probe distances in the range of 2-50 mm. Under certain conditions, the RL signal could be greatly disturbed by the so-called stem signal (i.e., unwanted light generated in the fiber cable upon irradiation). The OSL signal is not subject to this source of error. The tested system appears to be adequate for in vivo brachytherapy dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR {sup 192}Ir breast brachytherapy D-shaped applicators

Conformal dose coverage for accelerated partial breast irradiation or radiotherapy boost can be obtained with AccuBoost registered D-shaped brachytherapy applicators using a flattened surface positioned near the patient. Three D-shaped applicators (D45/D53/D60) were dosimetrically characterized using Monte Carlo methods (MCNP5), air ionization chambers (Farmer and Markus), and radiochromic film (GafChromic EBT) in polystyrene and ICRU 44 breast tissue. HDR {sup 192}Ir source dwell times were either constant or optimized to improve skin dose uniformity. Scatter dose decreased as depth decreased. 10 mm beyond the applicator aperture, dose reductions of 90% and 51% were observed at depths of 0 and 30 mm, respectively. Similarly, planar dose uniformity improved as depth decreased and was also due to scatter and applicator geometry. Dose uniformity inside the applicator aperture was approximately 11% and 15% for all three applicators at the skin and 30 mm deep, respectively. Depth dose measurements in polystyrene using ion chamber and radiochromic film agreed with Monte Carlo results within 2%. Discrepancies between film and Monte Carlo dose profiles at 30 mm depth were within 1%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of transit dose profile for a {sup 192}Ir HDR source

Purpose: Several studies have reported methodologies to calculate and correct the transit dose component of the moving radiation source for high dose rate (HDR) brachytherapy planning systems. However, most of these works employ the average source speed, which varies significantly with the measurement technique used, and does not represent a realistic speed profile, therefore, providing an inaccurate dose determination. In this work, the authors quantified the transit dose component of a HDR unit based on the measurement of the instantaneous source speed to produce more accurate dose values. Methods: The Nucletron microSelectron-HDR Ir-192 source was characterized considering the Task Group 43 (TG-43U1) specifications. The transit dose component was considered through the calculation of the dose distribution using a Monte Carlo particle transport code, MCNP5, for each source position and correcting it by the source speed. The instantaneous source speed measurements were performed in a previous work using two optical fibers connected to a photomultiplier and an oscilloscope. Calculated doses were validated by comparing relative dose profiles with those obtained experimentally using radiochromic films. Results: TG-43U1 source parameters were calculated to validate the Monte Carlo simulations. These agreed with the literature, with differences below 1% for the majority of the points. Calculated dose profiles without transit dose were also validated by comparison with ONCENTRA{sup Registered-Sign} Brachy v. 3.3 dose values, yielding differences within 1.5%. Dose profiles obtained with MCNP5 corrected using the instantaneous source speed profile showed differences near dwell positions of up to 800% in comparison to values corrected using the average source speed, but they are in good agreement with the experimental data, showing a maximum discrepancy of approximately 3% of the maximum dose. Near a dwell position the transit dose is about 22% of the dwell dose delivered by the source dwelling 1 s and reached 104.0 cGy per irradiation in a hypothetical clinical case studied in this work. Conclusions: The present work demonstrated that the transit dose correction based on average source speed fails to accurately correct the dose, indicating that the correct speed profile should be considered. The impact on total dose due to the transit dose correction near the dwell positions is significant and should be considered more carefully in treatments with high dose rate, several catheters, multiple dwell positions, small dwell times, and several fractions.

60 APPLIED LIFE SCIENCES↗

On the use of a single-fiber multipoint plastic scintillation detector for {sup 192}Ir high-dose-rate brachytherapy

Purpose: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during {sup 192}Ir high-dose-rate brachytherapy treatments.Methods: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested.Results: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 {+-} 2.1%, 3.0 {+-} 0.7%, and 4.5 {+-} 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 {+-} 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction.Conclusions: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-263: Point Dose Variation Using a Single Ir-192 HDR Brachytherapy Plan for Two Treatments with a Single Tandem-Ovoid Insertion for Cervical Cancer

Purpose: To evaluate the point dose variations between Ir-192 HDR treatments on two consecutive days using a single tandem-ovoid insertion without replanning in cervical cancer patients. Methods: This study includes eleven cervical cancer patients undergoing HDR brachytherapy with a prescribed dose of 28 Gy in 4 fractions. Each patient had two tandemovoid insertions one week apart. Each insertion was treated on consecutive days with rescanning and replanning prior to each treatment. To study the effect of no replanning for day 2 treatments, the day 1 plan dwell position and dwell time with decay were applied to the day 2 CT dataset. The point dose variations on the prescription point H (defined according to American Brachytherapy Society), and normal tissue doses at point B, bladder, rectum and vaginal mucosa (based on ICRU Report 38) were obtained. Results: Without replanning, the mean point H dose variation was 4.6 ± 10.7% on the left; 2.3 ± 2.9% on the right. The mean B point variation was 3.8 ± 4.9% on the left; 3.6 ± 4.7% on the right. The variation in the left vaginal mucosal point was 12.2 ± 10.7%; 9.5 ± 12.5% on the right; the bladder point 5.5 ± 7.4%; and the rectal point 7.9 ± 9.1%. Conclusion: Without replanning, there are variations both in the prescription point and the normal tissue point doses. The latter can vary as much as 10% or more. This is likely due to the steep dose gradient from brachytherapy compounded by shifts in the positions of the applicator in relationship to the patients anatomy. Imaging prior to each treatment and replanning ensure effective and safe brachytherapy are recommended.

60 APPLIED LIFE SCIENCES↗