Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Durable Multimetallic Electrocatalysts from Intermetallic Seeds

When combined with earth-abundant metals, Pt-based alloy nanoparticles (NPs) can be cost-effective electrocatalysts. However, these NPs can experience leaching of non-noble-metal components under harsh electrocatalytic conditions. In this work, the Skrabalak group has demonstrated a novel NP construct in which Pt-based random alloy surfaces are stabilized against non-noble-metal leaching by their deposition onto intermetallic seeds. These core@shell NPs are highly durable electrocatalysts, with the ability to tune catalytic performance by the core@shell architecture, surface alloy composition, and NP shape. This versatility was demonstrated in a model system in which random alloy (ra-) PtM surfaces were deposited onto ordered intermetallic (i-) PdCu seeds using seed-mediated co-reduction (SMCR). In the initial demonstration, ra-PtCu shells were deposited on i-PdCu seeds, with these core@shell NPs exhibiting higher specific and mass activities for the oxygen reduction reaction (ORR) when compared to similarly sized ra-PtCu NPs. These NPs also showed outstanding durability, maintaining ~85% in specific activity after 5000 cycles. Characterization of the NPs after use revealed minimal loss of Cu. The activity enhancement was attributed to the strained surface that arises from the lattice mismatch between the intermetallic core and random alloy surface. The outstanding durability was attributed to the ordered structure of the intermetallic core. The origin of this durability enhancement was investigated by classical molecular dynamics simulations, where Pt atoms were found to have a lower potential energy when deposited on an intermetallic core than when deposited on a random alloy core. Also, ordering of Cu atoms at the core@shell interface appears to enhance the overall binding between the core and the shell materials. Inspired by this initial demonstration, SMCR has been used to achieve shells of different random alloy compositions, PtM (M = Ni, Co, Cu, or Fe). This advance is significant because ligand effects vary as a function of PtM identity and Pt/M ratio. These features also influence the degree of surface strain imparted from the lattice mismatch between the core and shell materials. Like the initial demonstration, standout features of these core@shell NPs were high durability and resistance to non-noble metal leaching. Moving forward, efforts have been directed toward integrating shape-control to this core@shell NP construct. This integration is motivated by the shape-dependent catalytic performance of NPs derived from the selective expression of specific facets. Considering the initial i-PdCu@ra-PtCu system, NPs with a cubic shape have been achieved by judicious selection of capping ligands during SMCR. Evaluation of these NPs as catalysts for the electrooxidation of formic acid found that the nanocubic shape enhances catalytic performance compared to similar core@shell NPs with a spherical morphology. We envision that SMCR can be applied to other NP systems to achieve highly durable catalysts as the syntheses of monodisperse and shape-controlled intermetallic seeds are advanced. This Account highlights the role of intermetallic cores in providing more durable electrocatalysts. More broadly, the versatility of SMCR is highlighted as a route to integrate architecture, alloy surfaces, and shape within one NP system, and how this achievement is inspiring new high-performance and robust catalysts is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗

Evaluating Implementations of the Immersed Boundary Method in the Weather Research and Forecasting Model

The terrain-following coordinate system used by many atmospheric models can cause numerical instabilities due to discretization errors as resolved terrain slopes increase and the grid becomes highly skewed. The immersed boundary (IB) method, which does not require the grid to conform to the terrain, has been shown to alleviate these errors, and has been used successfully for high-resolution atmospheric simulations over steep terrain, including vertical building surfaces. Since many previous applications of IB methods to atmospheric models have used very fine grid resolution (5 m or less), the present study seeks to evaluate IB method performance over a range of grid resolutions and aspect ratios. Two classes of IB algorithms, velocity reconstruction and shear stress reconstruction, are tested within the common framework of the Weather Research and Forecasting (WRF) Model. Performance is evaluated in two test cases, one with flat terrain and the other with the topography of Askervein Hill, both under neutrally stratified conditions. WRF-IB results are compared to similarity theory, observations, and native WRF results. Despite sensitivity to the location at which the IB intersects the model grid, the velocity reconstruction IB method shows consistent performance when used with a hybrid RANS/LES surface scheme. The shear stress reconstruction IB method is not sensitive to the grid intersection, but is less consistent and near-surface velocity errors can occur at coarse resolutions. This study represents an initial investigation of IB method variability across grid resolutions in WRF. Future work will focus on improving IB method performance at intermediate to coarse resolutions.

54 ENVIRONMENTAL SCIENCES↗

Building 865 Hypersonic Wind Tunnel Power System Analysis

This report documents the characterization and analysis of a high current power supply for the building 865 Hypersonic Wind Tunnel at Sandia National Laboratories. The system described in this report became operational in 2013, replacing the original 1968 system which employed an induction voltage regulator. This analysis and testing was completed to help the parent organization understand why an updated and redesigned power system was not delivering adequate power to resistive heater elements in the HWT. This analysis led to an improved understanding of the design and operation of the revised 2013 power supply system and identifies several reasons the revised system failed to achieve the performance of the original power supply installation. Design modifications to improve the performance of this system are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building America Case Study: Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation (Fact Sheet)

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Framework for Machine-Learning-Enabled 13 C Fluxomics

13 C metabolic flux analysis (MFA) has emerged as a powerful tool for synthetic biology. This optimization-based approach suffers long computation time and unstable solutions depending on the initial guess. Here, we develop a machine-learning-based framework for 13 C fluxomics. Specifically, training and test data sets are generated by metabolic network decomposition and flux sampling, in which flux ratios at metabolic nodes and simulated labeling patterns of metabolites are used as training targets and features, respectively. To improve prediction accuracy and simplify the model, automated processes are developed for flux ratio selection based on solvability and feature screening based on importance. We found that predictive performance can be significantly improved using both amino acids and central carbon metabolites in comparison with amino acids alone. Together with measured external fluxes, the predicted flux ratios determine the mass balance system, yielding global flux distributions. This approach is validated by flux estimation using both simulated and experimental data in comparison with canonical 13 C MFA. The approach represents a reliable fluxomics method readily applicable to high-throughput metabolic phenotyping, which highlights the advances of intelligent learning algorithms in synthetic biology, specifically in the Test and Learn stage of the Design-Build-Test-Learn cycle.

13C metabolic flux analysis↗

On the Performance of Detecting Injection of Fabricated Messages into the CAN Bus

There have been several public demonstrations of attacks on connected vehicles showing the ability of an attacker to take control of a targeted vehicle by injecting messages into their Controller Area Network (CAN) bus. In this article, using injected speed reading and Revolutions Per Minute (RPM) reading messages in in-motion vehicle, we examine the ability of the Pearson correlation and the unsupervised learning methods k-means clustering and Hidden Markov Model (HMM) to differentiate ’no-attack’ and ’under-attack’ states of the given vehicle. We found that the Pearson correlation distinguishes the two states, the k-means clustering method has an acceptable accuracy but high false positive rate and HMM detects attacks with acceptable detection rate but has a high false positive in detecting attacks from speed readings when there is no attack. The accuracy of these unsupervised learning methods are comparable to the ones of the supervised learning methods used by CAN bus Intrusion Detection System (IDS) suppliers. In addition, the article shows that studying CAN anomaly detection techniques using off-vehicle test facilities may not properly evaluate the performance of the detection techniques. Finally, the results suggest using other features besides the data content of the CAN messages and integrate knowledge about how the Electronic Control Units (ECUs) collaborate in building effective techniques for the detection of injection of fabricated message attacks.

97 MATHEMATICS AND COMPUTING↗

A COMPUTATIONAL AND EXPERIMENTAL STUDY OF METAL AND COVALENT ORGANIC FRAMEWORKS USED IN ADSORPTION COOLING

Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years due to their potential applications in energy storage and gas separation. However, there have been few reports on MOFs for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems. Adsorption cooling is an excellent alternative in industrial environments where waste heat is available. Applications also include hybrid systems, refrigeration, power-plant dry cooling, cryogenics, vehicular systems and building HVAC. Adsorption based cooling and refrigeration systems have several advantages including few moving parts and negligible power consumption. Key disadvantages include large thermal mass, bulkiness, complex controls, and low COP (0.2-0.5). We explored the use of metal organic frameworks that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. An adsorption chiller based on MOFs suggests that a thermally-driven COP>1 may be possible with these materials, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. In addition, a cost model has been developed to project manufactured cost of entire systems. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Presented herein are computational and experimental results for hydrophyilic MOFs, fluorophilic MOFs and also flourophilic Covalent-organic frameworks (COFs).

adsorption↗

Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

Geoghegan, Patrick J↗

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Four-channel optically pumped atomic magnetometer for magnetoencephalography

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.

47 OTHER INSTRUMENTATION↗

Tuning Block Polymer Structure, Properties, and Processability for the Design of Efficient Nanostructured Materials Systems

Block polymers (BPs) are ideal building blocks for nanoporous membranes, microelectronics templates, energy storage devices, and other technologies. For these systems, precise control over morphology, properties, and processability are essential to optimize performance. The Epps group has used a multidisciplinary approach to control BP nanostructure ordering and orientations, order-disorder and glass transition temperatures, and mechanical and transport properties through the informed manipulation of BP effective segregation strengths and interfacial energetics. For example, alterations in macromolecular interactions between BP chains were achieved through the introduction of composition gradients between copolymer blocks or by adding dopants. In thin films, high-throughput approaches were designed to modify and characterize substrate-polymer interactions, and solvent annealing techniques were developed to facilitate nanoscale alignment and ordering. Finally, by manipulating BP interfacial energetics to gain exquisite tunability of nanostructures and materials' properties, the group is accelerating the development of next-generation BPs that will be harnessed to fabricate inexpensive, efficient, and high-performance devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Analysis of the US ITER ECH Transmission Line System

The electron cyclotron heating (ECH) and current drive system is one of the main plasma heating systems for ITER. It uses high-power microwave beams with the power deposition location steerable across the plasma cross section. Microwave power is conveyed via transmission lines (TLs) that run from the gyrotrons in the radio frequency building through the assembly hall and tokamak building to the ECH launchers within the tokamak vacuum vessel. The ECH system includes a vast array of interconnected TL waveguides, in-line components, and support structures.Finite element (FE) modeling provides an essential means of simulating the system, applying loads and determining deflections, rotations, forces, moments, and stresses in order to evaluate various structural and microwave transmission performance metrics. A representative FE model of the overall ECH TL system is developed in ANSYS®. This top-level model defines the centerline of the waveguide system. Waveguide segments are represented by line elements (beams and pipes) with equivalent section properties, and support structures are represented by boundary conditions. A systematic approach is used to model each ECH component with lumped masses and structurally equivalent stiffness matrices or ANSYS superelements.The top-level TL FE model is used to evaluate the various loads (thermal, vacuum, seismic, etc.) and operating scenarios. The top-level model directly calculates stresses in the straight aluminum waveguide segments. The model provides the forces and moments acting on the in-line components for detailed submodel assessments. Displacement results from the top-level analysis feed into a separate microwave performance model to help determine operational efficiency. All TL performance and thermal-structural requirements are met, as specified by the applicable codes and standards, and successfully documented in numerous technical reports and demonstrated at the final design review.

Shanmugasundaram, Aravind↗

A Rotational Control in Medium-Voltage Modular Solid-State Transformer-Based Converter System

This article presents a novel control strategy to significantly reduce the high-frequency transformer loss in a modular solid-state transformer (SST) based converter system. The modular SST design is based on an ac-dc power-electronic building block comprised of an H-bridge at the ac input and a bidirectional soft-switching isolated dc-dc converter with a medium-voltage insulated high-frequency transformer. The ac terminals of input H-bridges are connected in series and directly coupled to the medium-voltage ac line, while the output dc terminals are all connected in parallel at a low voltage. The key innovation described in this paper, without sacrificing the output performance, is the control scheme that reduces core and winding losses associated with the dc-dc resonant stage by turning off the selected dc-dc converters in synchronism with the line voltage. The prototype for the test described in this paper is based on a modular SST where each module is rated at 50 kVA, with a 200 kHz transformer using 1.7 kV silicon carbide discrete mosfets, but the described control concepts are more broadly applicable to similar topologies.

42 ENGINEERING↗

ThermoLift – A Natural Gas Fired Air Conditioner and Heat Pump

ThermoLift is developing TC-Cycle™, a natural-gas driven air conditioner and cold-climate heat pump that can provide space heating, water heating, and air conditioning in a single device. Unlike traditional heat-pump system, the TC-Cycle system uses helium as working fluid in place of high global warming potential HFC refrigerant. The system has broad application as a combined HVAC solution and technology development throughout this program has advanced the Technology Readiness Level (TRL) from TRL-1 to TRL-5 achieved in the Gen 3.0 prototype. In August of 2013, the US Department of Energy (DOE) provided Research and Development funding through the Building Technologies Innovations Program Funding Opportunity Announcement DE-FOA-0000823. The statement of work (SOW) outlined a deliverable of testing at ORNL and a final test report prepared to include various heating cooling temperature ranges and performance analysis. Furthermore, a milestone of this effort was to analyze all test data to establish further efficiency improvements and consider optimum manufacturing methodologies to facilitate the next level improvements. ThermoLift’s Gen 3.0 gas-fired heat pump was shipped and installed into ORNL’s test facility with most of the data reported herein obtained on August 6, 2018. Uninterrupted operation demonstrated cycle Coefficient of Performance (COP) well exceeding DOE targets for cold-climate heat pumps. Furthermore, there was no degradation in capacity as inlet (ambient) temperature decreased.

03 NATURAL GAS↗

VTK-m User's Guide (V.1.8)

Extreme scale systems require a new programming model and a fundamental change in how we design algorithms. To address these issues we created VTK-m: the visualization toolkit for multi-/many-core architectures. VTK-m supports a number of algorithms and the ability to design further algorithms through a top-down design with an emphasis on extreme parallelism. VTK-m also provides support for finding and building links across topologies, making it possible to perform operations that determine manifold surfaces, interpolate generated values, and find adjacencies. Although VTK-m provides a simplified high-level interface for programming, its template-based code removes the overhead of abstraction. VTK-m simplifies the development of parallel scientific visualization algorithms by providing a framework of supporting functionality that allows developers to focus on visualization operations. Additionally, VTK-m provides data abstractions not provided by other libraries that make code written in VTK-m more versatile.

97 MATHEMATICS AND COMPUTING↗

1972713

Energy-frontier particle accelerators are among the most exciting, complex, challenging, and expensive research instruments performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Currently the highest energy machines (under design or commissioned), from multi-GeV to several TeV, (ILC, FCC, CLIC) capable of searching for the most basic building blocks of matter are either driven by circular or linear accelerators [1-6]. Here (see also [7,8]) we suggest a novel design of circular-linear accelerator based on the merging of the weakly emitting, low-energy storage rings and energy recovery linear accelerators. To enable the operation of such a system and in particular the energy recovery from spent, high-intensity beams the use of the dual-axis asymmetric cavities is suggested. Merging circular and linear systems, and applications of dual axes cavities, aims to resolve both scientific and societal challenges. The merge of the systems will allow: 1) maintain high beam quality, high luminosity, and high energy efficiency; 2) offer a ?flexible? energy management via ?separation? of the collider and storage rings operations; 3) attract private partners via use of the storage rings to drive the next generation of the photon factories. The concept presented can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. We note that the numbers which will be presented are for illustration purpose and can be improved further.

Konoplev, I.↗