Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Onset phenomena in superfluid helium

Onset phenomena in superfluid helium have been studied by measuring the rotational decay constant of a levitated, superconducting niobium sphere coated with an unsaturated superfluid film. The novel features of onset that were observed are discussed. Previous observations of a two-layer-thick solid phase of helium underlying the film have been confirmed.

Wang, T. G.↗

Anomaly in the quiet-time helium spectrum at 1 MeV per nucleon

An unusual spectral feature and anomalously large abundance of helium between 0.6 and approximately 2 MeV per nucleon observed during the most quiet time periods in 1974 and 1975 indicate the presence of low energy helium of an unknown origin. Alphas below 0.6 MeV per nucleon and protons below 1.5 MeV have an E to the minus 1.8 power spectrum and the proton to alpha ratio is about 30. These less than or equal 1 MeV particles are found to be emitted continuously by the sun even during its most inactive periods.

Gloeckler, G.↗

Helium refrigerator

An improved helium refrigerator of the type which includes a plurality of counter-flow heat exchangers and has a maximum reserve cooling capacity when the final or low-temperature heat exchanger is substantially filled with liquid helium, and a minimum reserve cooling capacity when the low-temperature heat exchanger is substantially filled with gas. An electrical bridge circuit including a pair of temperature responsive resistors is mounted on the low-temperature heat exchanger for providing a continuous indication of the reserve cooling capacity of the refrigerator.

Ervin R Wiebe↗

The solar flare iron line to continuum ratio and the coronal abundances of iron and helium

Narrow band Ross filter measurements of the Fe 25 line flux around 0.185 nm and simultaneous broadband measurements during a solar flare were used to determine the relationship between the solar coronal abundances of iron and helium. The Fe 25 ion population was also determined as a function of time. The proportional counter and the Ross filter on OSO-7 were utilized. The data were analyzed under the separate assumptions that (1) the electron density was high enough that a single temperature could characterize the continuum spectrum and the ionization equilibrium, and that (2) the electron density was low so that the ion populations trailed the electron temperature in time. It was found that the density was at least 5x10 to the 9th power, and that the high density assumption was valid. It was also found that the iron abundance is 0.000011 for a helium abundance of 0.2, relative to hydrogen.

Mckenzie, D. L.↗

Determination of the light ion abundances in the strong-helium star HR 3089

Using line blanketed model stellar atmospheres and a spectrum synthesis approach, a differential abundance study of the ultraviolet spectrum of HR 3089 relative to the normal star lambda Sco was performed. Both stars were found to have the same abundances of carbon and silicon, but the helium and nitrogen are significantly enhanced in HR 3089. The atmospheric parameters and the distribution of abundances found for HR 3089 agree well with the results of Osmer and Peterson on sharp-lined helium-rich stars. The rotational velocity of 160 km/sec found for HR 3089 places a constraint on the role of diffusion in producing the abundance anomalies. Examination of the resonance lines of C II, N II, Si III and Si IV shows no evidence for mass loss in either star.

Lester, J. B.↗

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

A MHD channel, which was previously operated for over 500 hours of thermal operation, ten thermal cycles, and 200 cesium injection tests, was removed from the facility and redesigned. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. The redesigned channel has been operated for well over 300 hours, 10 thermal cycles, and 150 cesium injection tests with no problems. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. The best results to date have been obtained in the helium tests. Power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes were realized. Power densities of 0.6 MW/cu m and Hall fields of about 1,100 V/m were obtained in the tests with 17 electrodes.

Sovie, R. J.↗

Phase separation of metallic hydrogen-helium alloys

Calculations are presented for the thermodynamic functions and phase separation boundaries of solid metallic hydrogen helium alloys at temperatures between 0 K and 19,000 K and at pressures between 15 and 90 megabars. Expressions for the band structure energy of a randomly disordered alloy (including third order in the electron ion interaction) are derived and evaluated. Short and long range order are included by the quasi-chemical method, and lattice dynamics in the virtual crystal harmonic approximation. We conclude that at temperatures below 4,000 K there is complete phase separation of hydrogen helium alloys, and that a miscibility gap remains at the highest temperatures and pressures considered. The relevance of these results to models of the deep interior of Jupiter is briefly discussed.

Straus, D. M.↗

Investigation of hydrogen and helium pumping by sputter ion pumps for Jupiter and outer planets mass spectrometer

The phenomena of ion pumping is reviewed with emphasis on the pumping mechanism for hydrogen and helium. The experimental tests measure the performance of a small, flight proven ion pump which has a nominal four liter/second pumping speed for air. The speed of this pump for hydrogen and helium, and for hydrogen/helium mixes, is presented with particular detail regarding the time dependence. Pump test results are related to anticipated performance of the mass spectrometer by the pumping speeds for the gases to the partial pressure in the ion source. From this analysis, the pump specifications are quantified in terms of mission goals and in terms of observed pumping speeds for the various gases, load levels, and time periods.

Scott, B. W.↗

What quenches the helium shell flashes

An analysis is conducted of a typical stellar helium shell flash cycle. A sequence of 12 flashes for a population I star is considered. The changes taking place at a constant mass layer in the helium-burning shell are studied as the flash develops. A highly simplified mathematical description is presented, taking into account the three necessary conditions for the occurrence of the flash and the pressure-density and temperature-density relationships. Quantities which are helpful in explaining what triggers the flash are found to be useful in explaining what quenches the flash.

Sackmann, I.-J.↗

Extreme ultraviolet photometer for observations of helium in interplanetary space

A four-channel photometer sensitive to two solar EUV lines which are resonantly scattered by helium gas was developed for flight on the Apollo-Soyuz Test Project. Two channels observed the 58.4-nm line of He I and used helium gas resonant absorption cells to determine the intensities of the center and wings of that line. The other two channels observed the 30.4-nm line of He II. The instrument surveyed much of the celestial sphere during a series of slow rolling maneuvers by the Apollo spacecraft. The experiment operated properly, and usable data were obtained. Study of the distributions of flux seen, and of the ratio 58.4-nm fluxes seen with gas cells full and empty, will refine current understanding of several poorly known properties of the local interstellar medium. Study of the 30.4-nm flux distribution will refine present knowledge of the structure of the earth's plasmasphere.

Bowyer, S.↗

Phase separation of metallic hydrogen-helium alloys

Calculations are presented for the thermodynamic functions and phase-separation boundaries of solid metallic hydrogen-helium alloys at temperatures between zero and 19,000 K and at pressures between 15 and 90 Mbar. Expressions for the band-structure energy of a randomly disordered alloy (including third order in the electron-ion interaction) are derived and evaluated. Short- and long-range orders are included by the quasi-chemical method, and lattice dynamics in the virtual-crystal harmonic approximation. It is concluded that at temperatures below 4000 K, there is essentially complete phase separation of hydrogen-helium alloys and that a miscibility gap remains at the highest temperatures and pressures considered. The relevance of these results to models of the deep interior of Jupiter is briefly discussed.

Straus, D. M.↗

Correlated wave functions for three-particle systems with Coulomb interaction - The muonic helium atom

A computational procedure for calculating correlated wave functions is proposed for three-particle systems interacting through Coulomb forces. Calculations are carried out for the muonic helium atom. Variational wave functions which explicitly contain interparticle coordinates are presented for the ground and excited states. General Hylleraas-type trial functions are used as the basis for the correlated wave functions. Excited-state energies of the muonic helium atom computed from 1- and 35-term wave functions are listed for four states.

Huang, K.-N.↗

Liquid helium-cooled MOSFET preamplifier for use with astronomical bolometer

A liquid helium-cooled p-channel enhancement mode MOSFET, the 3N167, is found to have sufficiently low noise for use as a preamplifier with helium-cooled bolometers that are used in infrared astronomy. Its characteristics at 300, 77, and 4.2 K are presented. It is also shown to have useful application with certain photoconductive and photovoltaic infrared detectors.

Goebel, J. H.↗

Vacuum-ultraviolet laser uses superfluid helium

Vacuum ultra violet laser in wavelength around 0.800 microns is produced by using optical pumping to increase lifetimes of excited metastable molecules in super fluid helium. In method, super fluid helium is pumped electronically to produce excited HE2, and then pumped by circularly polarized 0.9096 - micron radiation to aline excited HE2 molecular spins. High power ultraviolet radiation has potential applications in molecular reaction studies, power transmission in space, and biomedical research.

Zmuidzinas, J. S.↗

A helium adsorption pump for temperatures between 0.71 and 1.2 K

The construction and method of working of a helium adsorption pump are described. The flux of helium-2 film can be suppressed by an appropriate construction, which permits it to reach temperatures down to 0.71 K. By total utilization of the pump's cross-section, temperatures from 1.2 K to 0.71 K remain constant for several hours with a precision of 0.001 K.

Frommann, G.↗

An experimental test for the charge state of the 'anomalous' helium component

Observations of phase lags between intensity variations for various particle species and energy ranges in the low-energy galactic cosmic radiation during the general intensity decrease observed in 1974-1975 show that, for particles whose charge state is known (i.e., 'normal' cosmic-ray components), particles with higher rigidities respond more quickly to changes in modulation conditions than do those with lower rigidities. When compared with particles of known energy and charge, the behavior of the 'anomalous' low-energy helium component is consistent with these observations only if the helium is singly rather than doubly charged.

Mckibben, R. B.↗

Use of the Jacchia /1977/ empirical model in a dynamical model of upper-atmospheric helium

This brief report describes an investigation of the effects of using the Jacchia (1977) model in place of the Jacchia (1971) model for specifying the background gas pressure in the theoretical model of thermospheric helium described by Straus, et al. (1977). Changes in the global transport of helium caused by a small increase in the latitudes at which the background gas pressure extrema occur lead to much better agreement of the model predictions with data taken by the mass spectrometers on board the Esro 4 and OGO 6 satellites.

Straus, J. M.↗

An interpretation of Mariner 10 helium /584 A/ and hydrogen /1216 A/ interplanetary emission observations

Measurements of the interplanetary emissions of both He(584 A) and H(1216 A) on January 28, 1974, a time of solar minimum, are reported and discussed. An analysis of the Mariner 10 ultraviolet spectrometer data shows that a simultaneous measurement of both emissions results in a self-consistent determination of the physical properties of the interstellar wind. With the aid of a model the number densities of helium and hydrogen outside the solar system were found to be 0.008 + or - 0.003/cu cm and 0.04 (+0.03, -0.02)/cu cm, respectively, which indicates a He/H ratio of 0.20 (+0.30, -0.13). Values characterizing the helium cone, interstellar wind temperature, effective lifetime of hydrogen atoms in the solar system, and downstream direction of the interstellar wind are presented.

Ajello, J. M.↗