Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guidance for Grid Resilience Decisions in Rural Minnesota

This report assesses the hazard landscape of the state of Minnesota, identifies weather hazards that are most impactful to the distribution system, includes a statewide assessment of household access to services dependent on reliable power, reviews resilience planning activities of electric utilities in Minnesota, and presents analysis of distribution grid performance in the face of extreme weather events with data from seven electric cooperatives dispersed throughout outstate Minnesota. This information is synthesized to provide considerations for resilience investment prioritization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tutorial of Wind Turbine Control for Supporting Grid Frequency through Active Power Control: Preprint

As wind energy becomes a larger portion of the world's energy portfolio and wind turbines become larger and more expensive, wind turbine control systems play an ever more prominent role in the design and deployment of wind turbines. The goals of traditional wind turbine control systems are maximizing energy production while protecting the wind turbine components. As more wind generation isinstalled there is an increasing interest in wind turbines actively controlling their power output in order to meet power setpoints and to participate in frequency regulation for the utility grid. This capability will be beneficial for grid operators, as it seems possible that wind turbines can be more effective at providing some of these services than traditional power plants. Furthermore,establishing an ancillary market for such regulation can be beneficial for wind plant owner/operators and manufacturers that provide such services. In this tutorial paper we provide an overview of basic wind turbine control systems and highlight recent industry trends and research in wind turbine control systems for grid integration and frequency stability.

17 WIND ENERGY↗

Supercomputing Centers and Electricity Service Providers: A Geographically Distributed Perspective on Demand Management in Europe and the United States, In: ISC High Performance 2016: High Performance Computing

Supercomputing Centers (SCs) have high and variable power demands, which increase the challenges of the Electricity Service Providers (ESPs) with regards to efficient electricity distribution and reliable grid operation. High penetration of renewable energy generation further exacerbates this problem. In order to develop a symbiotic relationship between the SCs and their ESPs and to support effective power management at all levels, it is critical to understand and analyze how the existing relationships were formed and how these are expected to evolve.

Computer Science↗

Progress on the FabrIc for Frontier Experiments project at Fermilab

The FabrIc for Frontier Experiments (FIFE) project is an ambitious, major-impact initiative within the Fermilab Scientific Computing Division designed to lead the computing model for Fermilab experiments. FIFE is a collaborative effort between experimenters and computing professionals to design and develop integrated computing models for experiments of varying needs and infrastructure. The major focus of the FIFE project is the development, deployment, and integration of Open Science Grid solutions for high throughput computing, data management, database access and collaboration within experiment. To accomplish this goal, FIFE has developed workflows that utilize Open Science Grid sites along with dedicated and commercial cloud resources. The FIFE project has made significant progress integrating into experiment computing operations several services including new job submission services, software and reference data distribution through CVMFS repositories, flexible data transfer client, and access to opportunistic resources on the Open Science Grid. Hence, the progress with current experiments and plans for expansion with additional projects will be discussed. FIFE has taken a leading role in the definition of the computing model for Fermilab experiments, aided in the design of computing for experiments beyond Fermilab, and will continue to define the future direction of high throughput computing for future physics experiments worldwide

97 MATHEMATICS AND COMPUTING↗

HexWeather: Hexagonal Spatial Data Aggregation for Weather-Driven Grid Resilience Analysis

Extreme weather accounts for over 8 0 % of major U.S. power outages since 2000, highlighting the need for spatial tools that align weather data with the irregular boundaries of electric infrastructure. This paper introduces HexWeather, a modular, resolution-aware framework for aggregating historical and forecasted weather data using Uber's H3 hexagonal spatial indexing system. Unlike traditional methods that rely on state or county-level grids, HexWeather enables weather analysis across custom geographies such as utility service areas where public datasets are often unavailable or misaligned. Using Open-Meteo data, we evaluate how H3 resolution affects anomaly detection, spatial variability, and forecast uncertainty across three scales: state, county, and utility. Results show that while coarse resolutions suffice for broad trend tracking, finer resolutions are essential for identifying localized variability and operational risks. By applying metrics like Z-score standard deviation and interquartile range, HexWeather quantifies the spatial spread of both historical anomalies and forecasted conditions, allowing users to assess resolution adequacy for each analysis. This framework supports rapid weather data reuse, reproducible anomaly detection, and predictive modeling for infrastructure resilience. By bridging spatial misalignment in traditional datasets and enabling retrospective and forward-looking analysis within the same pipeline, HexWeather lays the groundwork for better post event analysis, outage prediction, and resilience planning.

Morris, Jacob [ORNL]↗

Optimal Microgrid Networking for Maximal Load Delivery in Phase Unbalanced Distribution Grids: A Declarative Modeling Approach

Over the last several years, microgrids have increasingly become a part of the discussion about technologies that can improve the resilience of modern electrical grids. During extreme situations, microgrids have the capability to provide electrical service to customers within their boundaries when they would otherwise experience disruptions, and, when networked together, provide services to additional customers outside the microgrid boundaries. As a result, these technologies have motivated the community to develop new approaches for leveraging networked microgrid capabilities that utilize increasing levels of modeling sophistication. This has yielded a new challenge, where it has becoming increasingly difficult to fully quantify and evaluate the contribution of such detail. Here, the primary innovation presented in this paper is a method to standardize the approach to quantifying and evaluating these contributions via a declarative modeling approach that supports seamless mix-and-match of representations to ease comparison of modeling approaches and develop comprehensive understandings of how new contributions improve solutions to this problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Energy Storage Alternatives in the Puget Sound Energy System

As part of an ongoing study co-funded by the Bonneville Power Administration, under its Technology Innovation Grant Program, and the U.S. Department of Energy, the Pacific Northwest National Laboratory (PNNL) has developed an approach and modeling tool for assessing the net benefits of using energy storage located close to the customer in the distribution grid to manage demand. PNNL in collaboration with PSE and Primus Power has evaluated the net benefits of placing a zinc bromide battery system at two locations in the PSE system (Baker River / Rockport and Bainbridge Island). Energy storage can provide a number of benefits to the utility through the increased flexibility it provides to the grid system. Applications evaluated in the assessment include capacity value, balancing services, arbitrage, distribution deferral and outage mitigation. This report outlines the methodology developed for this study and Phase I results.

25 ENERGY STORAGE↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Export Feeder Through Transactive Markets

This project is aimed at creating a transactive energy market to address the challenges faced by utility providers when increasing distributed energy resource (DER) adoption in their service area. One major challenge is mitigating export back to the grid during times of excess production. The transactive energy market operates at the distribution level and balances the supply and demand on the feeder, thus maintaining a zero-energy export at the primary feeder head. The market participants in this case are the residential customers on the feeder, who bid into the market. Building controls are then optimized based on the settled price. Market performance was demonstrated in this study by simulating different levels of DER penetration on a selected Pepco feeder. The feeder successfully achieved a zero export while providing cost-effective electricity to the participants, demonstrating that this market design can enable high DER penetration on existing feeders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS) Global Snow-Cover Maps

Following the 1999 launch of the Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS), the capability exists to produce global snow-cover maps on a daily basis at 500-m resolution. Eight-day composite snow-cover maps will also be available. MODIS snow-cover products are produced at Goddard Space Flight Center and archived and distributed by the National Snow and Ice Data Center (NSIDC) in Boulder, Colorado. The products are available in both orbital and gridded formats. An online search and order tool and user-services staff will be available at NSIDC to assist users with the snow products. The snow maps are available at a spatial resolution of 500 m, and 1/4 degree x 1/4 degree spatial resolution, and provide information on sub-pixel (fractional) snow cover. Pre-launch validation work has shown that the MODIS snow-mapping algorithms perform best under conditions of continuous snow cover in low vegetation areas, but can also map snow cover in dense forests. Post-launch validation activities will be performed using field and aircraft measurements from a February 2000 validation mission, as well as from existing satellite-derived snow-cover maps from NOAA and Landsat-7 Enhanced Thematic Mapper Plus (ETM+).

Hall, Dorothy K.↗

Lightning Detection Efficiency Analysis Process: Modeling Based on Empirical Data

A ground based lightning detection system employs a grid of sensors, which record and evaluate the electromagnetic signal produced by a lightning strike. Several detectors gather information on that signal s strength, time of arrival, and behavior over time. By coordinating the information from several detectors, an event solution can be generated. That solution includes the signal s point of origin, strength and polarity. Determination of the location of the lightning strike uses algorithms based on long used techniques of triangulation. Determination of the event s original signal strength relies on the behavior of the generated magnetic field over distance and time. In general the signal from the event undergoes geometric dispersion and environmental attenuation as it progresses. Our knowledge of that radial behavior together with the strength of the signal received by detecting sites permits an extrapolation and evaluation of the original strength of the lightning strike. It also limits the detection efficiency (DE) of the network. For expansive grids and with a sparse density of detectors, the DE varies widely over the area served. This limits the utility of the network in gathering information on regional lightning strike density and applying it to meteorological studies. A network of this type is a grid of four detectors in the Rondonian region of Brazil. The service area extends over a million square kilometers. Much of that area is covered by rain forests. Thus knowledge of lightning strike characteristics over the expanse is of particular value. I have been developing a process that determines the DE over the region [3]. In turn, this provides a way to produce lightning strike density maps, corrected for DE, over the entire region of interest. This report offers a survey of that development to date and a record of present activity.

Rompala, John T.↗

Comprehensive analysis of technical efficiency of business establishments in Santa Barbara County: Evaluation of spatial and aspatial stochastic frontier models

One of the main objectives of land-use and transport models is to accurately describe the organization and composition of the regional economy. However, these models currently lack the integration of competitiveness and performance of the regional economy, which in-turn is dependent on performance and efficiency of business establishments in the region. In this study, we present a framework that integrates the aspects of economic efficiency of business establishments within the context of land-use and transport models. For this purpose, we comprehensively assess the impacts of both internal and external attributes of business establishment on its efficiency. In this process, we specifically focus on aspects of incorporating locational characteristics using two frameworks - (a) measuring locational attributes using link-based multiple centrality indicators (L-MCI) and (b) measuring neighborhood effects of business establishments through spatial proximity that account for co-location and competition. We make use of the stochastic frontier modeling framework to investigate the factors impacting business establishment-level output measured as sales per unit area. Specifically, the aspatial stochastic frontier (ASF) model incorporates L-MCI measures as covariates and the spatial stochastic frontier (SSF) model incorporates neighborhood effects of business establishments through network distance measured using the roadway network for Santa Barbara County.Overall, the empirical results suggest that there exist significant inefficiencies across all business establishment types that are mainly impacted by internal attributes of the business. For example, larger and older business establishments are more efficient than business establishments that are smaller in size and younger in age. Furthermore, the results also suggest that locational impacts are better captured using the ASF specification when compared with SSF specification. For instance, the spatial correlation estimate (from SSF) although statistically significant, is very weak. Thereby, indicating a lack of spatial structure in technical efficiency of businesses manifested in the form of co-location and competition. In contrast, the ASF model captures spatial structure of technical efficiency thoroughly with inclusion of the L-MCI measures. This indicates that L-MCI measures have varying levels of impact on efficiency (positive or negative) depending on its relative location in the region. For instance, retail trade businesses have higher levels of revenue (or sales per unit area) when located along links in a grid-network like structure e.g. downtown areas. Additionally, businesses in professional services have no impact on their efficiency based on the configuration and structure of the regional transportation network. However, results from both specifications indicate that there exist major benefits on efficiency of business establishments from local competition for retail trade and healthcare services.

Ravulaparthy, Srinath↗

Productive Use of Energy in African Micro-Grids: Technical and Business Considerations

Demand for electricity from small industry and businesses, which is defined as the productive use of energy (PUE), is a key success factor for micro-grids. Because of the typically low energy usage of residential customers, without linkage to and support for these energy users, micro-grids are likely to struggle to reach the critical revenue needed for financial viability. This report is a resource entrepreneurs and developers can use to understand the technical and business model challenges related to PUE in smaller micro-grids. It focuses on small agricultural processing, and small industrial and commercial loads. This report examines best practices for promoting PUE and the business models used by developers. It starts with background information and a literature review followed by a discussion of key enterprise considerations for productive use (PU) including: value chain and business case analysis, enterprise development and training, appliance financing, and developers running PU businesses. Unlike many other reports on PUE, this report is based on application specific data. The report is also unique in that it provides actual customer demographics and load profiles. This report considers PUE from both business and technical perspectives, and it considers the interests of both the micro-grid operators and the microenterprises and entrepreneurs they serve. It looks at the service levels required by different PUs and the technical characteristics and challenges of different types of PU equipment. The report also includes examples of business cases for some of the most important PU opportunities, including milling, ice making, carpentry, egg incubation, and water treatment. This report is a resource that entrepreneurs, governments, and non-governmental organizations can use to help design programs to meet their individual goals of PUE in micro-grids and economic development in rural Africa. It can also be used by developers, engineers, and other organizations designing micro-grids to inform their technical and business decisions and to improve system design, reduce risk, and increase success with adding PU loads to both new and existing micro-grids.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

It's Not Just About the Megawatts - ARC Industry Forum, The Future of Power Generation

As the world transitions to less carbon intensive energy portfolios, much of the attention understandably centers on generating capacity – replacing megawatts of fossil fuel with megawatts of solar, wind, nuclear, hydroelectric, hydrogen, and more. The actual operation of a reliable grid needs more than just megawatts though: adequate quantities of a portfolio of essential reliability services; flexible and capable power delivery systems; governance to operate in 5-10 minute intervals, forecast hourly, and plan and build on a generational time horizon; and dependable and secure communications. We can choose our fuel mix for climate reasons, but the grid itself and the society that relies upon it impose constraints on those choices that we ignore at our peril.

13 HYDRO ENERGY↗

Survey and Analysis of Weather Data for Building Energy Simulations

In recent years, calibrated energy modeling of residential and commercial buildings has gained importance in a retrofit-dominated market. Accurate weather data plays an important role in this calibration process and projected energy savings. It would be ideal to measure weather data at the building location to capture relevant microclimate variation but this is generally considered cost-prohibitive. There are data sources publicly available with high temporal sampling rates but at relatively poor geospatial sampling locations. To overcome this limitation, there are a growing number of service providers that claim to provide real time and historical weather data for 20-35 km2 grid across the globe. Unfortunately, there is limited documentation from 3rd-party sources attesting to the accuracy of this data. This paper compares provided weather characteristics with data collected from a weather station inaccessible to the service providers. Monthly average dry bulb temperature; relative humidity; direct, diffuse and horizontal solar radiation; and wind speed are statistically compared. Moreover, we ascertain the relative contributions of each weather variable and its impact on building loads. Annual simulations are calculated for three different building types, including a closely monitored and automated energy efficient research building. The comparison shows that the difference for an individual variable can be as high as 90%. In addition, annual building energy consumption can vary by 7% while monthly building loads can vary by 40% as a function of the provided location s weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗